Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anesthesiology ; 120(4): 906-14, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24694847

ABSTRACT

BACKGROUND: The role of lung ultrasound has never been evaluated in parturients with severe preeclampsia. The authors' first aim was to assess the ability of lung ultrasound to detect pulmonary edema in severe preeclampsia. The second aim was to highlight the relation between B-lines and increased left ventricular end-diastolic pressures. METHODS: This prospective cohort study was conducted in a level-3 maternity during a 12-month period. Twenty parturients with severe preeclampsia were consecutively enrolled. Both lung and cardiac ultrasound examinations were performed before (n = 20) and after delivery (n = 20). Each parturient with severe preeclampsia was compared with a control healthy parturient. Pulmonary edema was determined using two scores: the B-pattern and the Echo Comet Score. Left ventricular end-diastolic pressures were assessed by transthoracic echocardiography. RESULTS: Lung ultrasound detected interstitial edema in five parturients (25%) with severe preeclampsia. A B-pattern was associated to increased mitral valve early diastolic peak E (116 vs. 90 cm/s; P = 0.05) and to increased E/E' ratio (9.9 vs. 6.6; P < 0.001). An Echo Comet Score of greater than 25 predicted an increase in filling pressures (E/E' ratio >9.5) with a sensitivity and specificity of 1.00 (95% CI, 0.69 to 1.00) and 0.82 (95% CI, 0.66 to 0.92), respectively. CONCLUSIONS: In parturients with severe preeclampsia, lung ultrasound detects both pulmonary edema and increased left ventricular end-diastolic pressures. The finding of a B-pattern should restrict the use of fluid. However, these preliminary results are associations from a single sample. They need to be replicated in a larger, definitive study.


Subject(s)
Hemodynamics , Lung/diagnostic imaging , Pre-Eclampsia/diagnostic imaging , Pre-Eclampsia/epidemiology , Pulmonary Edema/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Cohort Studies , Comorbidity , Diastole , Echocardiography/methods , Female , Follow-Up Studies , Humans , Lung/physiopathology , Observer Variation , Pre-Eclampsia/physiopathology , Predictive Value of Tests , Pregnancy , Prospective Studies , Pulmonary Edema/epidemiology , Pulmonary Edema/physiopathology , Sensitivity and Specificity , Severity of Illness Index , Syndrome , Ventricular Dysfunction, Left/epidemiology , Ventricular Dysfunction, Left/physiopathology
2.
Intensive Care Med ; 39(4): 593-600, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23223774

ABSTRACT

PURPOSE: Because severe preeclampsia (SP) may be associated with acute pulmonary oedema, fluid responsiveness needs to be accurately predicted. Passive leg raising (PLR) predicts fluid responsiveness. PLR has never been reported during pregnancy. Our first aim was to determine the percentage of SP patients with oliguria increasing their stroke volume after fluid challenge. Our second aim was to assess the accuracy of PLR to predict fluid responsiveness in those patients. METHODS: Patients with SP were prospectively included in the study. In the subgroup developing oliguria, transthoracic echocardiography was performed at baseline, during PLR and after a 500 ml fluid infusion over 15 min. Fluid responders were defined by a 15 % increase of stroke volume index. Five consecutive measurements were averaged for all parameters. RESULTS: Twenty-three (56 %) out of 41 patients with SP developed oliguria, 12 (52 %) out of these 23 responded to fluid challenge. During PLR, an increase of the velocity time integral of subaortic blood flow (ΔVTI) above 12 % predicted the response with a sensitivity and specificity of 75 [95 % confident interval (CI): 0.42-0.95] and 100 % (95 % CI: 0.72-1.00), respectively. An algorithm combining ΔVTI and the baseline value of VTI predicted fluid responsiveness with a sensitivity and specificity of 100 % (95 % CI: 0.74-1.00) and (95 % CI: 0.75-1.00). Urine output and respiratory variations of inferior vena cava diameter did not predict fluid responsiveness. CONCLUSIONS: Only 52 % of oliguric patients were responders. PLR accurately predicts fluid responsiveness in the specific setting of SP. This noninvasive test should be tested in future algorithms for the management of SP.


Subject(s)
Fluid Therapy/adverse effects , Oliguria/complications , Pre-Eclampsia/therapy , Pulmonary Edema/etiology , Stroke Volume/physiology , Adult , Cardiac Output/physiology , Echocardiography , Female , Fluid Therapy/methods , Fluid Therapy/standards , France , Hemodynamics/physiology , Humans , Leg/blood supply , Pre-Eclampsia/physiopathology , Pregnancy , Prognosis , Prospective Studies , Risk Factors , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...