1.
Neth Heart J ; 28(5): 280-292, 2020 May.
Article in English | MEDLINE | ID: mdl-32189208

ABSTRACT

Guidelines suggest using frailty characteristics in the work-up for a transcatheter aortic valve implantation (TAVI). There are many frailty-screening tools with different components. The prognostic value of the individual parameters in frailty is as yet unclear. The objective of this systematic review and meta-analysis was to find and pool predictors for 1­year mortality after TAVI. We followed a two-step approach. First, we searched for randomised controlled trials on TAVI to identify frailty parameters used in these studies. Second, we searched for publications on these frailty parameters. Articles were included for pooled analysis if the studied frailty parameters were dichotomised with clear cut-off values based on common standards or clinical practice and reported adjusted hazard ratios (HR) of 1­year mortality after TAVI. We calculated pooled effect estimates of 49 studies based on dichotomised frailty scores (HR: 2.16, 95% CI: 1.57-3.00), chronic lung disease (HR: 1.57, 95% CI: 1.45-1.70), estimated glomerular filtration rate <30 ml/min (HR: 1.95, 95% CI: 1.68-2.29), body mass index <20 kg/m2 (HR: 1.49, 95% CI: 1.09-2.03), hypoalbuminaemia (HR: 1.77, 95% CI: 1.38-2.25), anaemia (HR: 2.08, 95% CI: 0.93-4.66), low gait speed (HR: 13.33, 95% CI: 1.75-101.49) and Katz activities of daily living (ADL) score of 1 or more deficits (HR: 5.16, 95% CI: 0.77-34.47). Chronic lung disease, chronic kidney disease, underweight, hypoalbuminaemia, a low frailty score, anaemia, low gait speed and an ADL deficiency were associated with worse 1­year outcomes after TAVI.

2.
Neth Heart J ; 27(4): 167-168, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30788776
3.
Int J Cardiovasc Imaging ; 35(4): 645-651, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30499057

ABSTRACT

The aim of the current study was to investigate whether stress echocardiography improves selection of patients who might have clinical benefit from percutaneous mitral valve repair with the MitraClip. In total, 39 patients selected for MitraClip implantation underwent preprocedural low-dose stress (dobutamine or handgrip) echocardiography from which stroke volume, ejection fraction and MR grade were measured. Outcome after MitraClip implantation was determined by New York Heart Association classification and Quality of Life questionnaires. Clinical benefit from MitraClip treatment was defined as survival and NYHA class I-II at 6 months follow-up. In total, 36 patients with a technically successful procedure were included in the analysis (mean age 79 ± 8 years, 47% male, 50% functional MR). Clinical benefit was achieved in 18 patients. All seven patients with MR decreasing during stress remained in NYHA III-IV or died within 6 months, while 62% (18 out of 29) of the patients with stable or increased MR during stress had clinical benefit (p = 0.008). Significant increase in Quality of Life on 4/8 subscales of the RAND Short Form-36 questionnaire was observed: Physical Functioning (p < 0.001), Social Functioning (p < 0.001), Mental Health (p = 0.022) and Vitality (p = 0.026) was seen in patients with an increase in stroke volume during stress echocardiography. Patients with a decreased MR during preprocedural stress echocardiography remained more symptomatic than patients with a stable or increased MR during stress. Stress echocardiography may support patient selection for percutaneous mitral valve repair.


Subject(s)
Cardiac Catheterization , Echocardiography, Stress , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Adrenergic beta-1 Receptor Agonists/administration & dosage , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/mortality , Clinical Decision-Making , Dobutamine/administration & dosage , Exercise , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Mitral Valve/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Patient Selection , Predictive Value of Tests , Prospective Studies , Quality of Life , Recovery of Function , Risk Factors , Treatment Outcome
4.
Neth Heart J ; 25(6): 394-400, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28444570

ABSTRACT

PURPOSE: Data on MitraClip procedural safety and efficacy in the Netherlands are scarce. We aim to provide an overview of the Dutch MitraClip experience. METHODS: We pooled anonymised demographic and procedural data of 1151 consecutive MitraClip patients, from 13 Dutch hospitals. Data was collected by product specialists in collaboration with local operators. Effect on mitral regurgitation was intra-procedurally assessed by transoesophageal echocardiography. Technical success and device success were defined according to modified definitions of the Mitral Valve Academic Research Consortium (MVARC). RESULTS: Median age was 76 (interquartile range 69-82) years and 59% were males. Patients presented with ≥moderate mitral regurgitation and a predominance of functional mitral regurgitation (72%). Overall, 611 (53%) patients were treated with one Clip, 486 (42%) with ≥2 Clips and 54 (5%) received no Clip. The number of patients with ≥2 Clips increased from 22% in 2009 to 52% in 2016. Device success and technical success were 91 and 95%, respectively, and were consistent over the years. Significant reduction of mitral regurgitation by MitraClip was achieved in 94% of patients and was observed more often in patients with functional mitral regurgitation (95% vs. 91%, p = 0.025). Device time declined from 145 min in 2009 to 55 min in 2016. CONCLUSION: MitraClip experience in the Netherlands is growing with excellent technical success and device success. Over the years, device time decreased and more patients were treated with ≥2 Clips.