Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
bioRxiv ; 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38645178

ABSTRACT

Diffuse gliomas are epigenetically dysregulated, immunologically cold, and fatal tumors characterized by mutations in isocitrate dehydrogenase (IDH). Although IDH mutations yield a uniquely immunosuppressive tumor microenvironment, the regulatory mechanisms that drive the immune landscape of IDH mutant (IDHm) gliomas remain unknown. Here, we reveal that transcriptional repression of retinoic acid (RA) pathway signaling impairs both innate and adaptive immune surveillance in IDHm glioma through epigenetic silencing of retinol binding protein 1 (RBP1) and induces a profound anti-inflammatory landscape marked by loss of inflammatory cell states and infiltration of suppressive myeloid phenotypes. Restorative retinoic acid therapy in murine glioma models promotes clonal CD4 + T cell expansion and induces tumor regression in IDHm, but not IDH wildtype (IDHwt), gliomas. Our findings provide a mechanistic rationale for RA immunotherapy in IDHm glioma and is the basis for an ongoing investigator-initiated, single-center clinical trial investigating all-trans retinoic acid (ATRA) in recurrent IDHm human subjects.

2.
Sensors (Basel) ; 23(12)2023 Jun 07.
Article in English | MEDLINE | ID: mdl-37420576

ABSTRACT

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.


Subject(s)
Computer Communication Networks , Physics , Reproducibility of Results , Computer Simulation , Ultrasonic Waves
3.
Sensors (Basel) ; 23(13)2023 Jun 30.
Article in English | MEDLINE | ID: mdl-37447912

ABSTRACT

This paper presents a novel probabilistic machine learning (PML) framework to estimate the Brillouin frequency shift (BFS) from both Brillouin gain and phase spectra of a vector Brillouin optical time-domain analysis (VBOTDA). The PML framework is used to predict the Brillouin frequency shift (BFS) along the fiber and to assess its predictive uncertainty. We compare the predictions obtained from the proposed PML model with a conventional curve fitting method and evaluate the BFS uncertainty and data processing time for both methods. The proposed method is demonstrated using two BOTDA systems: (i) a BOTDA system with a 10 km sensing fiber and (ii) a vector BOTDA with a 25 km sensing fiber. The PML framework provides a pathway to enhance the VBOTDA system performance.


Subject(s)
Machine Learning , Optical Devices , Models, Statistical , Signal Processing, Computer-Assisted , Uncertainty
4.
Sensors (Basel) ; 21(6)2021 Mar 16.
Article in English | MEDLINE | ID: mdl-33809575

ABSTRACT

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18" diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.