Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
1.
JACC Case Rep ; 29(6): 102237, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38549851

ABSTRACT

We report a case of a 16-year-old man in cardiogenic shock secondary to On-X mitral prosthesis dysfunction due to leaflet embolization through aortic mechanical prosthesis. He underwent an emergency redo mitral valve replacement and, a few days later, leaflet removal by open aortic surgery with full recovery.

2.
Front Endocrinol (Lausanne) ; 14: 1252966, 2023.
Article in English | MEDLINE | ID: mdl-37766687

ABSTRACT

Introduction: Significant bone loss occurs after heart transplantation, predominantly in the first year, with increased risk of incident fractures. The goal of this study was to evaluate the prevalence of fragility fractures in a population of heart transplantation patients and to identify the independent risk factors for fractures. Methods: This was a prospective monocentric study that included patients with heart transplantation occurring < 10 years who were undergoing heart transplantation monitoring. All patients underwent bone mineral density evaluation by dual-energy X-ray absorptiometry and radiographies to establish the presence of vertebral fractures. Results: We included 79 patients (61 men); the mean age was 56.8 ± 10.8 years. The mean time between transplantation and inclusion was 32.3 ± 35.0 months. Incident fractures were diagnosed in 21 (27%) patients after heart transplantation. Vertebral fractures were the most frequent (30 vertebral fractures for 15 patients). Osteoporosis was confirmed in 22 (28%) patients. Mean bone mineral density at the femoral neck and total hip was lower with than without fracture (femoral neck: 0.777 ± 0.125 vs 0.892 ± 0.174 g/cm2, p<0.01; total hip: 0.892 ± 0.165 vs 0.748 ± 0.07 g/cm2, p<0.001), with a significant result on multivariate analysis. The mean time from transplantation to the first fracture was 8.0 ± 7.6 months. Discussion: Our study confirmed a high vertebral fracture risk in heart transplant patients, especially during the first year after transplantation.


Subject(s)
Fractures, Bone , Heart Transplantation , Osteoporosis , Spinal Fractures , Male , Humans , Middle Aged , Aged , Prospective Studies , Osteoporosis/epidemiology , Osteoporosis/etiology , Bone Density , Spinal Fractures/epidemiology , Spinal Fractures/etiology , Heart Transplantation/adverse effects
3.
J Heart Lung Transplant ; 42(5): 558-561, 2023 05.
Article in English | MEDLINE | ID: mdl-36822931

ABSTRACT

SARS-CoV-2 Omicron variant was first detected in France mid-November 2021 in wastewater treatment plants while cases started to increase at the beginning of December. The maximum incidence occurred in mid-January 2022. The Omicron wave spread rapidly throughout France in general population with lower case-fatality rate compared with previous waves. Little is known about infection with Omicron variant in heart transplant (HT) recipients. In this study, we examined incidence and mortality rate of COVID-19 in the general population and among 1,263 HT recipients during the period from June, 2021 to February, 2022, described characteristics of HT recipients infected with SARS-CoV-2 during Omicron (December 1st, 2021-February 7, 2022) and Delta (June 1st- November 30, 2021) periods, and compared hospital course of HT recipients with Omicron and Delta variant infection. Our findings contrast with the reported lower severity for Omicron variant infection compared with Delta variant infection in immunocompetent individuals.


Subject(s)
COVID-19 , Heart Transplantation , Humans , SARS-CoV-2 , France/epidemiology
4.
Front Psychol ; 13: 946271, 2022.
Article in English | MEDLINE | ID: mdl-35959024

ABSTRACT

Body awareness refers to the individual ability to process signals originating from within the body, which provide a mapping of the body's internal landscape (interoception) and its relation with space and movement (proprioception). The present study aims to evaluate psychometric properties and validate in French two self-report measures of body awareness: the Postural Awareness Scale (PAS), and the last version of the Multidimensional Assessment of Interoceptive Awareness questionnaire (version 2, MAIA-2). We collected data in a non-clinical, adult sample (N = 308; 61% women, mean age 35 ± 12 years) using online survey, and a subset of the original sample (n = 122; 62% women, mean age 44 ± 11 years) also completed the retest control. Factor analyses and reliability analyses were conducted. Construct validity of the PAS and the MAIA-2 were examined by testing their association with each other, and with self-report measures of personality (Big Five Inventory), alexithymia (Toronto Alexithymia Scale) and dispositional trait mindfulness (Freiburg Mindfulness Inventory). Factor analyses of the PAS supported the same two-factor structure as previously published versions (in other languages). For the MAIA-2, factor analyses suggested that a six-factor structure, excluding Not-Worrying and Not-Distracting factors, could successfully account for a common general factor of self-reported interoception. We found satisfactory internal consistency, construct validity, and reliability over time for both the PAS and the MAIA-2. Altogether, our findings suggest that the French version of the PAS and the MAIA-2 are reliable self-report tools to assess both components of body awareness (proprioception and interoception dimension, respectively).

5.
Pulm Circ ; 12(3): e12125, 2022 Jul.
Article in English | MEDLINE | ID: mdl-36016669

ABSTRACT

Doppler echocardiography plays a central role in the assessment of pulmonary hypertension (PAH). We aim to improve quality assessment of systolic pulmonary arterial pressure (SPAP) by applying a cubic polynomial interpolation to digitized tricuspid regurgitation (TR) waveforms. Patients with PAH and advanced lung disease were divided into three cohorts: a derivation cohort (n = 44), a validation cohort (n = 71), an outlier cohort (n = 26), and a non-PAH cohort (n = 44). We digitized TR waveforms and analyzed normalized duration, skewness, kurtosis, and first and second derivatives of pressure. Cubic polynomial interpolation was applied to three physiology-driven phases: the isovolumic phase, ejection phase, and "shoulder" point phase. Coefficients of determination and a Bland-Altman analysis was used to assess bias between methods. The cubic polynomial interpolation of the TR waveform correlated strongly with expert read right ventricular systolic pressure (RVSP) with R 2 > 0.910 in the validation cohort. The biases when compared to invasive SPAP measured within 24 h were 6.03 [4.33; 7.73], -2.94 [1.47; 4.41], and -3.11 [-4.52; -1.71] mmHg, for isovolumic, ejection, and shoulder point interpolations, respectively. In the outlier cohort with more than 30% difference between echocardiographic estimates and invasive SPAP, cubic polynomial interpolation significantly reduced underestimation of RVSP. Cubic polynomial interpolation of the TR waveform based on isovolumic or early ejection phase may improve RVSP estimates.

6.
Crit Care Med ; 50(5): e426-e433, 2022 05 01.
Article in English | MEDLINE | ID: mdl-34974497

ABSTRACT

OBJECTIVES: Temporary circulatory support (TCS) as a bridge-to-left ventricular assist device (BTL) in cardiogenic shock patients has been increasing, but limited data exists on this BTL strategy. We aimed at analyzing the outcome of BTL patients in a population of cardiogenic shock patients compared with those without TCS at the time of the left ventricular assist device (LVAD) surgery and identify predictors of postoperative mortality in this specific population. DESIGN: A multicenter retrospective observational study conducted in 19 centers from 2006 to 2016. SETTING: Nineteen French centers. PATIENTS: A total of 329 cardiogenic shock patients at the time of LVAD implantation were analyzed. Patients were divided in three groups: those under TCS at the time of LVAD implantation (n = 173), those with TCS removal before LVAD surgery (n = 24), and those who did not undergo a bridging strategy (n = 152). Primary endpoint was 30-day mortality. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Among the BTL group, 68 (39.3%), 18 (10.4%), and 15 (8.7%) patients were under venoarterial extracorporeal membrane oxygenation, Impella, and IABP support alone, and 72 patients (20.6%) were under multiple TCS support. BTL patients presented similar 30 days survival compared with the TCS removal and non-BTL groups. However, BTL group had a significantly longer ICU duration stay, with two-fold duration of mechanical ventilation time, but the three groups experienced similar postoperative complications. Multivariate analysis identified three independent predictors of mortality in the BTL group: combined surgery with LVAD, body mass index (BMI), and heart failure (HF) duration. BTL strategy was not an independent predictor of mortality in cardiogenic shock patients who underwent LVAD. CONCLUSIONS: BTL strategy is not associated with a lower survival among cardiogenic shock patients with LVAD implantation. Predictors of mortality are combined surgery with LVAD, higher BMI, and HF duration.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Heart-Assist Devices , Extracorporeal Membrane Oxygenation/adverse effects , Heart Failure/complications , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Retrospective Studies , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Treatment Outcome
7.
ESC Heart Fail ; 8(6): 5159-5167, 2021 12.
Article in English | MEDLINE | ID: mdl-34494391

ABSTRACT

AIMS: Despite regularly updated guidelines, there is still a delay in referral of advanced heart failure patients to mechanical circulatory support and transplant centres. We aimed to analyse characteristics and outcome of non-inotrope-dependent patients implanted with a left ventricular assist device (LVAD). METHODS AND RESULTS: The ASSIST-ICD registry collected LVAD data in 19 centres in France between February 2006 and December 2016. We used data of patients in Interagency Registry for Mechanically Assisted Circulatory Support Classes 4-7. The primary endpoint was survival analysis. Predictors of mortality were searched with multivariable analyses. A total of 303 patients (mean age 61.0 ± 9.9 years, male sex 86.8%) were included in the present analysis. Ischaemic cardiomyopathy was the leading heart failure aetiology (64%), and bridge to transplantation was the main implantation strategy (56.1%). The overall likelihood of being alive while on LVAD support or having a transplant at 1, 2, 3, and 5 years was 66%, 61.7%, 58.7%, and 55.1%, respectively. Age [hazard ratio (HR) 1.03, 95% confidence interval (CI) 1.00-1.05; P = 0.02], a concomitant procedure (HR 2.32, 95% CI 1.52-3.53; P < 0.0001), and temporary mechanical right ventricular support during LVAD implantation (HR 2.94, 95% CI 1.49-5.77; P = 0.002) were the only independent variables associated with mortality. Heart failure medications before or after LVAD implantation were not associated with survival. CONCLUSION: Ambulatory heart failure patients displayed unsatisfactory survival rates after LVAD implantation. A better selection of patients who can benefit from LVAD may help improving outcomes.


Subject(s)
Heart Failure , Heart-Assist Devices , Aged , Heart Failure/complications , Heart Failure/therapy , Humans , Male , Middle Aged , Registries , Survival Rate , Treatment Outcome
8.
Transpl Int ; 34(4): 721-731, 2021 04.
Article in English | MEDLINE | ID: mdl-33539616

ABSTRACT

Available data on clinical presentation and mortality of coronavirus disease-2019 (COVID-19) in heart transplant (HT) recipients remain limited. We report a case series of laboratory-confirmed COVID-19 in 39 HT recipients from 3 French heart transplant centres (mean age 54.4 ± 14.8 years; 66.7% males). Hospital admission was required for 35 (89.7%) cases including 14/39 (35.9%) cases being admitted in intensive care unit. Immunosuppressive medications were reduced or discontinued in 74.4% of the patients. After a median follow-up of 54 (19-80) days, death and death or need for mechanical ventilation occurred in 25.6% and 33.3% of patients, respectively. Elevated C-reactive protein and lung involvement ≥50% on chest computed tomography (CT) at admission were associated with an increased risk of death or need for mechanical ventilation. Mortality rate from March to June in the entire 3-centre HT recipient cohort was 56% higher in 2020 compared to the time-matched 2019 cohort (2% vs. 1.28%, P = 0.15). In a meta-analysis including 4 studies, pre-existing diabetes mellitus (OR 3.60, 95% CI 1.43-9.06, I2  = 0%, P = 0.006) and chronic kidney disease stage III or higher (OR 3.79, 95% CI 1.39-10.31, I2  = 0%, P = 0.009) were associated with increased mortality. These findings highlight the aggressive clinical course of COVID-19 in HT recipients.


Subject(s)
COVID-19/diagnosis , Heart Transplantation , Postoperative Complications/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , COVID-19/etiology , COVID-19/mortality , COVID-19/therapy , COVID-19 Testing , Female , Follow-Up Studies , France , Humans , Male , Middle Aged , Postoperative Complications/etiology , Postoperative Complications/mortality , Postoperative Complications/therapy , Prognosis , Prospective Studies , Respiration, Artificial/statistics & numerical data , Risk Factors , Severity of Illness Index , Young Adult
9.
Am J Cardiol ; 146: 82-88, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33549526

ABSTRACT

LVAD implantation in patients with a recently diagnosed cardiomyopathy has been poorly investigated. This work aims at describing the characteristics and outcomes of patients receiving a LVAD within 30 days following the diagnosis of cardiomyopathy. Patients from the ASSIST-ICD study was divided into recently and remotely diagnosed cardiomyopathy based on the time from initial diagnosis of cardiomyopathy to LVAD implantation using the cut point of 30 days. The primary end point of the study was all-cause mortality at 30-day and during follow-up. A total of 652 patients were included and followed during a median time of 9.1 (2.5 to 22.1) months. In this population, 117 (17.9%) had a recently diagnosed cardiomyopathy and had LVAD implantation after a median time of 15.0 (9.0 to 24.0) days following the diagnosis. This group of patients was significantly younger, with more ischemic cardiomyopathy, more sudden cardiac arrest (SCA) events at the time of the diagnosis and were more likely to receive temporary mechanical support before LVAD compared with the remotely diagnosed group. Postoperative in-hospital survival was similar in groups, but recently diagnosed patients had a better long-term survival after hospital discharge. SCA before LVAD and any cardiac surgery combined with LVAD implantation were identified as 2 independent predictors of postoperative mortality in recently diagnosed patients. In conclusion, rescue LVAD implantation for recently diagnosed severe cardiomyopathy is common in clinical practice. Such patients experience a relatively low postoperative mortality and have a better long-term survival compared with remotely diagnosed patients.


Subject(s)
Cardiomyopathies/therapy , Heart-Assist Devices , Aged , Cardiomyopathies/diagnosis , Cardiomyopathies/mortality , Female , France/epidemiology , Humans , Male , Middle Aged , Prognosis , Prosthesis Design , Retrospective Studies , Survival Rate/trends
11.
Arch Cardiovasc Dis ; 113(11): 701-709, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32952086

ABSTRACT

BACKGROUND: Left ventricular assist device (LVAD) implantation may be an attractive alternative therapeutic option for elderly patients with heart failure who are ineligible for heart transplantation. AIM: We aimed to describe the characteristics and outcomes of elderly patients (i.e. aged≥70 years) receiving an LVAD. METHODS: This observational study was conducted in 19 centres between 2006 and 2016. Patients were divided into two groups-younger (aged<70 years) and elderly (aged≥70 years), based on age at time of LVAD implantation. RESULTS: A total of 652 patients were included in the final analysis, and 74 patients (11.3%) were aged≥70 years at the time of LVAD implantation (maximal age 77.6 years). The proportion of elderly patients receiving an LVAD each year was constant, with a median of 10.6% (interquartile range 8.0-15.4%) per year, and all were implanted as destination therapy. Elderly and younger patients had similar durations of hospitalization in intensive care units and total lengths of hospital stays. Both age groups experienced similar rates of LVAD-related complications (i.e. stroke, bleeding, driveline infection and LVAD exchange), and the occurrence of LVAD complications did not impact survival in the elderly group compared with the younger group. Lastly, when compared with younger patients implanted as destination therapy, the elderly group also exhibited similar mid-term survival. CONCLUSION: This work strongly suggests that selected elderly adults can be scheduled for LVAD implantation.


Subject(s)
Heart Failure/therapy , Prosthesis Implantation/instrumentation , Ventricular Function, Left , Age Factors , Aged , Female , France , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/physiopathology , Heart-Assist Devices , Humans , Male , Middle Aged , Prosthesis Implantation/adverse effects , Prosthesis Implantation/mortality , Recovery of Function , Risk Factors , Time Factors , Treatment Outcome
12.
Am J Cardiol ; 133: 81-88, 2020 10 15.
Article in English | MEDLINE | ID: mdl-32861423

ABSTRACT

We aimed at characterizing the impact of low and high body mass index (BMI) on outcomes after left-ventricular assist device (LVAD) surgery and define the predictors of mortality in patients with abnormal BMI (low/high). This study was conducted in 19 centers from 2006 to 2016. Patients were divided based on their baseline BMI into 3 groups of BMI: low (BMI ≤18.5 kg/m²); normal (BMI = 18.5 to 24.99 kg/m²) and high (BMI ≥25 kg/m²) (including overweight (BMI = 25 to 29.99 kg/m²), and obesity (BMI ≥30 Kg/m²)). Among 652 patients, 29 (4.4%), 279 (42.8%) and 344 (52.8%) had a low-, normal-, and high BMI, respectively. Patients with high BMI were significantly more likely men, with more co-morbidities and more history of ventricular/supra-ventricular arrhythmias before LVAD implantation. Patients with abnormal BMI had significantly lower survival than those with normal BMI. Notably, those with low BMI experienced the worst survival whereas overweight or obese patients had similar survival. Four predictors of mortality for LVAD candidates with abnormal BMI were defined: total bilirubin ≥16 µmol/L before LVAD, hypertension, destination therapy, and cardiac surgery with LVAD. Depending on the number of predictor per patients, those with abnormal BMI may be divided in 3 groups of 1-year mortality risk, i.e., low (0 to 1 predictor: 29% and 31%), intermediate (2 to 3 predictors, 51% and 52%, respectively), and high (4 predictors: 83%). In conclusion, LVAD recipients with abnormal BMI experience lower survival, especially underweight patients. Four predictors of mortality have been identified for LVAD population with abnormal BMI, differentiating those a low-, intermediate-, and high risks of death.


Subject(s)
Body Mass Index , Heart Failure/therapy , Heart-Assist Devices , Obesity/complications , Thinness/complications , Aged , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/mortality , Humans , Male , Middle Aged , Obesity/mortality , Retrospective Studies , Risk Factors , Survival Rate , Thinness/mortality , Treatment Outcome
13.
Eur J Cardiothorac Surg ; 58(1): 112-120, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32298439

ABSTRACT

OBJECTIVES: Our goal was to provide a picture of left ventricular assist device (LVAD) activity in France between 2007 and 2016 based on the multicentric ASSIST-ICD registry. METHODS: We retrospectively collected 136 variables including in-hospital data, follow-up survival rates and adverse events from 671 LVAD recipients at 20 out of 24 LVAD implant centres in France. The average follow-up time was 1.2 years (standard deviation: 1.4); the total follow-up time was 807.5 patient-years. RESULTS: The included devices were the HeartMate II®, HeartWare LVAS® or Jarvik 2000®. The overall likelihood of being alive while on LVAD support or having a transplant (primary end point) at 1, 2, 3 and 5 years postimplantation was 65.2%, 59.7%, 55.9% and 47.7%, respectively, given a cumulative incidence of 29.2% of receiving a transplant at year 5. At implantation, 21.5% of patients were on extracorporeal life support. The overall rate of cardiogenic shock at implantation was 53%. The major complications were driveline infection (26.1%), pump pocket or cannula infection (12.6%), LVAD thrombosis (12.2%), ischaemic (12.8%) or haemorrhagic stroke (5.4%; all strokes 18.2%), non-cerebral haemorrhage (9.1%) and LVAD exchange (5.2%). The primary end point (survival) was stratified by age at surgery and by the type of device used, with inference from baseline profiles. The primary end point combined with an absence of complications (secondary end point) was also stratified by device type. CONCLUSIONS: The ASSIST-ICD registry provides a real-life picture of LVAD use in 20 of the 24 implant centres in France. Despite older average age and a higher proportion of patients chosen for destination therapy, survival rates improved compared to those in previous national registry results. This LVAD registry contrasts with other international registries because patients with implants have more severe disease, and the national policy for graft attribution is distinct. We recommend referring patients for LVAD earlier and suggest a discussion of the optimal timing of a transplant for bridged patients (more dismal results after the second year of support?).


Subject(s)
Heart Failure , Heart-Assist Devices , France/epidemiology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Humans , Registries , Retrospective Studies , Treatment Outcome
15.
Am J Cardiol ; 125(9): 1421-1428, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32145895

ABSTRACT

The impact of uncommon etiology cardiomyopathies on Left-ventricular assist device (LVAD)-recipient outcomes is not very well known. This study aimed to characterize patients with uncommon cardiomyopathy etiologies and examine the outcomes between uncommon and ischemic/idiopathic dilated cardiomyopathy. This observational study was conducted in 19 centers between 2006 and 2016. Baseline characteristics and outcomes of patients with uncommon etiology were compared to patients with idiopathic dilated/ischemic cardiomyopathies. Among 652 LVAD-recipients included, a total of 590 (90.5%) patients were classified as ischemic/idiopathic and 62 (9.5%) patients were classified in the "uncommon etiologies" group. Main uncommon etiologies were: hypertrophic (n = 12(19%)); cancer therapeutics-related cardiac dysfunction (CTRCD) (n = 12(19%)); myocarditis (n = 11(18%)); valvulopathy (n = 9(15%)) and others (n = 18(29%)). Patients with uncommon etiologies were significantly younger with more female and presented less co-morbidities. Additionally, patients with uncommon cardiomyopathies were less implanted as destination therapy compared with ischemic/idiopathic group (29% vs 38.8%). During a follow-up period of 9.1 months, both groups experienced similar survival. However, subgroup of hypertrophic/valvular cardiomyopathies and CTRCD had significantly higher mortality compared to the ischemic/idiopathic or myocarditis/others cardiomyopathies. Conversely, patients with myocarditis/others etiologies experienced a better survival. Indeed, the 12-months survival in the myocarditis/others; ischemic/idiopathic and hypertrophic/CTRCD/valvulopathy group were 77%; 65%, and 46% respectively. In conclusion, LVAD-recipients with hypertrophic cardiomyopathy, valvular heart disease and CTRCD experienced the higher mortality rate.


Subject(s)
Cardiomyopathy, Dilated/surgery , Cardiomyopathy, Hypertrophic/surgery , Heart-Assist Devices , Myocardial Ischemia/surgery , Adult , Aged , Cardiomyopathy, Dilated/etiology , Cardiomyopathy, Hypertrophic/etiology , Female , Humans , Male , Middle Aged , Myocardial Ischemia/etiology , Retrospective Studies , Treatment Outcome
16.
Clin Infect Dis ; 70(11): 2405-2412, 2020 05 23.
Article in English | MEDLINE | ID: mdl-31309973

ABSTRACT

BACKGROUND: Etiological diagnosis is a key to therapeutic adaptation and improved prognosis, particularly for infections such as endocarditis. In blood culture-negative endocarditis (BCNE), 22% of cases remain undiagnosed despite an updated comprehensive syndromic approach. This prompted us to develop a new diagnostic approach. METHODS: Eleven valves from 10 BCNE patients were analyzed using a method that combines human RNA bait-depletion with phi29 DNA polymerase-based multiple displacement amplification and shotgun DNA sequencing. An additional case in which a microbe was serendipitously visualized by immunofluorescence was analyzed using the same method, but after laser capture microdissection. RESULTS: Background DNA prevented any diagnosis in cases analyzed without microdissection because the majority of sequences were contaminants. Moraxella sequences were dramatically enriched in the stained microdissected region of the additional case. A consensus genome sequence of 2.4 Mbp covering more than 94% of the Moraxella osloensis KSH reference genome was reconstructed with 234X average coverage. Several antibiotic-resistance genes were observed. Etiological diagnosis was confirmed using Western blot and specific polymerase chain reaction with sequencing on a different valve sample. CONCLUSIONS: Microdissection could be a key to the metagenomic diagnosis of infectious diseases when a microbe is visualized but remains unidentified despite an updated optimal approach. Moraxella osloensis should be tested in blood culture-negative endocarditis.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Blood Culture , Endocarditis/diagnosis , Endocarditis, Bacterial/diagnosis , Humans , Metagenomics , Moraxella
17.
JACC Clin Electrophysiol ; 5(8): 944-954, 2019 08.
Article in English | MEDLINE | ID: mdl-31439296

ABSTRACT

OBJECTIVES: This study aimed to evaluate incidence, clinical significance, and predictors of early ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients. BACKGROUND: LVAD implantation is increasingly used in patients with end-stage heart failure. Early VAs may occur during the 30-day post-operative period, but many questions remain unanswered regarding their incidence and clinical impact. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Early VAs were defined as sustained ventricular tachycardia and/or ventricular fibrillation occurring <30 days post-LVAD implantation and requiring appropriate implantable cardioverter-defibrillator therapy, external electrical shock, or medical therapy. RESULTS: A total of 652 patients (median age: 59.8 years; left ventricular ejection fraction: 20.7 ± 7.4%; HeartMate 2: 72.8%; HeartWare: 19.5%; Jarvik 2000: 7.7%) were included in the analysis. Early VAs occurred in 162 patients (24.8%), most frequently during the first week after LVAD implantation. Multivariable analysis identified history of VAs prior to LVAD and any combined surgery with LVAD as 2 predictors of early VAs. The occurrence of early VAs with electrical storm was the strongest predictor of 30-day post-operative mortality, associated with a 7-fold increase of 30-day mortality. However, in patients discharged alive from hospital, occurrence of early VAs did not influence long-term survival. CONCLUSIONS: Early VAs are common after LVAD implantation and increase 30-day post-operative mortality, without affecting long-term survival. Further studies will be needed to analyze whether pre- or pre-operative ablation of VAs may improve post-operative outcomes. (Determination of Risk Factors of Ventricular Arrhythmias After Implantation of Continuous Flow Left Ventricular Assist Device With Continuous Flow Left Ventricular Assist Device [ASSIST-ICD]; NCT02873169).


Subject(s)
Arrhythmias, Cardiac , Heart Ventricles/physiopathology , Heart-Assist Devices , Postoperative Complications , Aged , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/mortality , Female , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Postoperative Complications/mortality , Retrospective Studies
18.
Am Heart J ; 214: 69-76, 2019 08.
Article in English | MEDLINE | ID: mdl-31174053

ABSTRACT

BACKGROUND: Left ventricular assist device (LVAD)-associated infections may be life-threatening and impact patients' outcome. We aimed to identify the characteristics, risk factors, and prognosis of LVAD-associated infections. METHODS: Patients included in the ASSIST-ICD study (19 centers) were enrolled. The main outcome was the occurrence of LVAD-associated infection (driveline infection, pocket infection, or pump/cannula infection) during follow-up. RESULTS: Of the 652 patients enrolled, 201 (30.1%) presented a total of 248 LVAD infections diagnosed 6.5 months after implantation, including 171 (26.2%), 51 (7.8%), and 26 (4.0%) percutaneous driveline infection, pocket infection, or pump/cannula infection, respectively. Patients with infections were aged 58.7 years, and most received HeartMate II (82.1%) or HeartWare (13.4%). Most patients (62%) had implantable cardioverter-defibrillators (ICDs) before LVAD, and 104 (16.0%) had ICD implantation, extraction, or replacement after the LVAD surgery. Main pathogens found among the 248 infections were Staphylococcus aureus (n = 113' 45.4%), Enterobacteriaceae (n = 61; 24.6%), Pseudomonas aeruginosa (n = 34; 13.7%), coagulase-negative staphylococci (n = 13; 5.2%), and Candida species (n = 13; 5.2%). In multivariable analysis, HeartMate II (subhazard ratio, 1.56; 95% CI, 1.03 to 2.36; P = .031) and ICD-related procedures post-LVAD (subhazard ratio, 1.43; 95% CI, 1.03-1.98; P = .031) were significantly associated with LVAD infections. Infections had no detrimental impact on survival. CONCLUSIONS: Left ventricular assist device-associated infections affect one-third of LVAD recipients, mostly related to skin pathogens and gram-negative bacilli, with increased risk with HeartMate II as compared with HeartWare, and in patients who required ICD-related procedures post-LVAD. This is a plea to better select patients needing ICD implantation/replacement after LVAD implantation.


Subject(s)
Catheter-Related Infections/etiology , Heart-Assist Devices/adverse effects , Prosthesis-Related Infections/etiology , Catheter-Related Infections/epidemiology , Catheter-Related Infections/microbiology , Catheter-Related Infections/mortality , Defibrillators, Implantable/statistics & numerical data , Device Removal/statistics & numerical data , Female , France/epidemiology , Heart Ventricles , Heart-Assist Devices/statistics & numerical data , Humans , Male , Middle Aged , Multivariate Analysis , Prognosis , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Retrospective Studies , Risk Factors
19.
JACC Clin Electrophysiol ; 4(9): 1166-1175, 2018 09.
Article in English | MEDLINE | ID: mdl-30236390

ABSTRACT

OBJECTIVES: This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. BACKGROUND: The arrhythmic risk and need for ICD in patients implanted with an LVAD are not very well known. METHODS: This observational study was conducted in 19 centers between 2006 and 2016. Late VAs were defined as sustained ventricular tachycardia or fibrillation occurring >30 days post-LVAD implantation, without acute reversible cause and requiring appropriate ICD therapy, external electrical shock, or medical therapy. RESULTS: Among 659 LVAD recipients, 494 (median 58.9 years of age; mean left ventricular ejection fraction 20.7 ± 7.4%; 73.1% HeartMate II, 18.6% HeartWare, 8.3% Jarvik 2000) were discharged alive from hospital and included in the final analysis. Late VAs occurred in 133 (26.9%) patients. Multivariable analysis identified 6 independent predictors of late VAs: VAs before LVAD implantation, atrial fibrillation before LVAD implantation, idiopathic etiology of the cardiomyopathy, heart failure duration >12 months, early VAs (<30 days post-LVAD), and no angiotensin-converting enzyme inhibitors during follow-up. The "VT-LVAD score" was created, identifying 4 risk groups: low (score 0 to 1), intermediate (score 2 to 4), high (score 5 to 6), and very high (score 7 to 10). The rates of VAs at 1 year were 0.0%, 8.0%, 31.0% and 55.0%, respectively. CONCLUSIONS: Late VAs are common after LVAD implantation. The VT-LVAD score may help to identify patients at risk of late VAs and guide ICD indications in previously nonimplanted patients. (Determination of Risk Factors of Ventricular Arrhythmias [VAs] after implantation of continuous flow left ventricular assist device with continuous flow left ventricular assist device [CF-LVAD] [ASSIST-ICD]; NCT02873169).


Subject(s)
Arrhythmias, Cardiac , Defibrillators, Implantable , Heart-Assist Devices/adverse effects , Aged , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/mortality , Arrhythmias, Cardiac/surgery , Female , Humans , Male , Middle Aged , Retrospective Studies , Risk Factors
20.
Arch Cardiovasc Dis ; 111(8-9): 528-533, 2018.
Article in English | MEDLINE | ID: mdl-30030045

ABSTRACT

BACKGROUND: With the emergence of transcatheter mitral valve replacement, it appears crucial to provide contemporary references with which this new technology can be compared. At our institution, transoesophageal echocardiography is systematically performed before discharge after surgical mitral valve replacement. AIM: To evaluate the rate and determinants of paravalvular regurgitation after surgical mitral valve replacement. METHODS: We collected medical history, indication, type of surgery and in-hospital outcome in all consecutive patients who underwent a mitral valve replacement in the past 2 years at our institution. Paravalvular regurgitation was assessed semiquantitatively using transoesophageal echocardiography before discharge. RESULTS: We enrolled 399 patients (mean age 61±16 years; 58% women; 27% with a history of cardiac surgery). Mitral valve replacement was performed mainly for rheumatic disease (44%). Most patients were severely symptomatic (70% in New York Heart Association class III/IV). A mechanical prosthesis was implanted in 60% and a bioprosthesis in 40%. In-hospital mortality was 10%. Transoesophageal echocardiography was performed in 310 patients (77%); the main reasons for not performing transoesophageal echocardiography were frailty (n=40, 10%), early death (n=19, 5%) and contraindication for transoesophageal echocardiography (n=10, 3%). The overall rate of paravalvular regurgitation was 8% (n=25); a grade ≥2 was observed in five patients (2%), and two patients had to be reoperated on. Mitral annular calcification was the main factor associated with paravalvular regurgitation (P=0.01). CONCLUSIONS: Surgical mitral valve replacement was associated with significant in-hospital mortality and morbidity. Using systematic transoesophageal echocardiography assessment, paravalvular regurgitation was not uncommon (8%), and was significantly linked to mitral annulus calcification. However, clinically significant leakage (≥grade 2) was rare (2%).


Subject(s)
Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve/surgery , Rheumatic Heart Disease/surgery , Aged , Calcinosis/diagnostic imaging , Calcinosis/mortality , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/mortality , Hospital Mortality , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Paris/epidemiology , Predictive Value of Tests , Prevalence , Retrospective Studies , Rheumatic Heart Disease/diagnostic imaging , Rheumatic Heart Disease/mortality , Rheumatic Heart Disease/physiopathology , Risk Factors , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...