1.
J Appl Clin Med Phys ; 25(6): e14353, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38693646

ABSTRACT

BACKGROUND: A physical scatter grid is not often used in pelvic bedside examinations. However, multiple studies regarding scatter correction software (SC SW) are available for mobile chest radiography but the results are unclear for pelvic radiography. PURPOSE: We evaluated SC SW of Fujifilm (Virtual Grid) on gridless pelvic radiographs obtained from a human Thiel-embalmed body to investigate the potential of Virtual Grid in pelvic bedside examinations. METHODS: Gridless, Virtual Grid, and physical grid pelvic radiographs of a female Thiel-embalmed body were collected with a broad range of tube loads. Different software (SW) grid ratios-6:1, 10:1, 13:1, 17:1, and 20:1-were applied on the gridless radiographs to investigate the image quality (IQ) improvement of 13 IQ criteria in a visual grading analysis (VGA) setup. RESULTS: Gridless radiograph scores are significantly lower (p < 0.001) than Virtual Grid and physical grid scores obtained with the same tube load. Virtual Grid radiographs score better than gridless radiographs obtained with a higher tube load which makes a dose reduction possible. The averaged ratings of the IQ criteria processed with different SW ratios increase with increasing SW grid ratios. However, no statistically significant differences were found between the SW grid ratios. The scores of the physical grid radiographs are higher than those of the Virtual Grid radiographs when they are obtained with the same tube load. CONCLUSION: We conclude that Virtual Grid with an SW ratio of 6:1 improves the IQ of gridless pelvic radiographs in such a manner that a dose reduction is possible. However, physical grid radiograph ratings are higher compared to those of Virtual Grid radiographs.


Subject(s)
Pelvis , Humans , Female , Pelvis/diagnostic imaging , Image Processing, Computer-Assisted/methods , Software , Scattering, Radiation , Radiographic Image Interpretation, Computer-Assisted/methods , Radiation Dosage , Phantoms, Imaging
2.
Eur Radiol ; 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38459347

ABSTRACT

Sacroiliitis is commonly seen in patients with axial spondyloarthritis, in whom timely diagnosis and treatment are crucial to prevent irreversible structural damage. Imaging has a prominent place in the diagnostic process and several new imaging techniques have been examined for this purpose. We present a summary of updated evidence-based practice recommendations for imaging of sacroiliitis. MRI remains the imaging modality of choice for patients with suspected sacroiliitis, using at least four sequences: coronal oblique T1-weighted and fluid-sensitive sequences, a perpendicular axial oblique sequence, and a sequence for optimal evaluation of the bone-cartilage interface. Both active inflammatory and structural lesions should be described in the report, indicating location and extent. Radiography and CT, especially low-dose CT, are reasonable alternatives when MRI is unavailable, as patients are often young. This is particularly true to evaluate structural lesions, at which CT excels. Dual-energy CT with virtual non-calcium images can be used to depict bone marrow edema. Knowledge of normal imaging features in children (e.g., flaring, blurring, or irregular appearance of the articular surface) is essential for interpreting sacroiliac joint MRI in children because these normal processes can simulate disease. CLINICAL RELEVANCE STATEMENT: Sacroiliitis is a potentially debilitating disease if not diagnosed and treated promptly, before structural damage to the sacroiliac joints occurs. Imaging has a prominent place in the diagnostic process. We present a summary of practice recommendations for imaging of sacroiliitis, including several new imaging techniques. KEY POINTS: • MRI is the modality of choice for suspected inflammatory sacroiliitis, including a joint-line-specific sequence for optimal evaluation of the bone-cartilage interface to improve detection of erosions. • Radiography and CT (especially low-dose CT) are reasonable alternatives when MRI is unavailable. • Knowledge of normal imaging features in children is mandatory for interpretation of MRI of pediatric sacroiliac joints.

3.
Insights Imaging ; 15(1): 53, 2024 Feb 18.
Article in English | MEDLINE | ID: mdl-38369564

ABSTRACT

OBJECTIVES: The purpose of this study is to assess the equivalency of MRI-based synthetic CT (sCT) to conventional CT for sacroiliac joint bony morphology assessment in children. METHODS: A prospective study was performed. Children who had (PET-)CT-scan underwent additional MRI. sCT-CT image quality was analyzed by two readers subjectively overall, semi-quantitatively in terms of cortical delineation, joint facet defects, growth plate fusion, ossified nuclei, lumbosacral transitional anomaly, and bony bridges, and quantitatively for disc space height, spinal canal width, and sacral vertebrae width and height. Cohen's kappa and equivalence analyses with Bland-Altman plots were calculated for categorical and continuous measures respectively. RESULTS: Ten patients were included (6 boys; aged 9-16 years; mean age 14 years). Overall sCT image quality was rated good. Semi-quantitative assessment of cortical delineation of sacroiliac joints, bony bridges, and joint facet defects on the right iliac and sacral sides showed perfect agreement. Correlation was good to excellent (kappa 0.615-1) for the presence of lumbosacral transitional anomaly, fusion of sacral growth plates, joint facet defect, and presence of ossified nuclei. sCT-CT measurements were statistically equivalent and within the equivalence margins (-1-1 mm) for intervertebral disc space height and spinal canal width. Intra- and inter-reader reliability was excellent for quantitative assessment (0.806 < ICC < 0.998). For categorical scoring, kappa ranged from substantial to excellent (0.615-1). CONCLUSION: sCT appears to be visually equivalent to CT for the assessment of pediatric sacroiliac joints. sCT may aid in visualizing sacroiliac joints compared to conventional MRI, with the benefit that no ionizing radiation is used, especially important in children. CRITICAL RELEVANCE STATEMENT: MRI-based synthetic CT, a new technique that generates CT-like images without ionizing radiation, appears to be visually equivalent to CT for assessment of normal pediatric sacroiliac joints and can potentially assess structural damage as it clearly depicts bony cortex. KEY POINTS: • MRI-based sCT is a new image technique that can generate CT-like images. • We found that sCT performs similarly to CT in displaying bony structures of pediatric sacroiliac joints. • sCT has already been clinically validated in the sacroiliac joints in adults. • sCT can potentially assess structural damage from erosions or ankylosis as it clearly depicts bony cortex.

4.
Skeletal Radiol ; 53(3): 507-514, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37682337

ABSTRACT

OBJECTIVE: To determine the prevalence of sacroiliac joint variants in patients with axial spondyloarthritis (axSpA) using MRI-based synthetic CT images and to evaluate their relationships with the presence of bone marrow edema, as this may potentially complicate diagnosing active sacroiliitis on MRI in patients with suspected axSpA. METHODS: 172 patients were retrospectively included. All patients underwent MRI because of clinical suspicion of sacroiliitis. The diagnosis of axSpA was made by a tertiary hospital rheumatologist. Two readers independently determined the presence of bone marrow edema and the presence of one or more of the nine known sacroiliac joint (SIJ) variants. RESULTS: SIJ variants were common in axSpA patients (82.9%) and the non-SpA group (85.4%); there were no significant differences in prevalence. Bone marrow edema was frequently found in axSpA (86.8%) and non-SpA patients (34%). AxSpA patients with SIJ variants (except for accessory joint) demonstrated 4 to 10 times higher odds for bone marrow edema, however not statistically significant. The more variants were present in this group, the higher the chance of bone marrow edema. However, some multicollinearity cannot be excluded, since bone marrow edema is very frequent in the axSpA group by definition. CONCLUSION: SIJ variants are common in axSpA and non-SpA patients. SIJ variants were associated with higher prevalence of bone marrow edema in axSpA patients, potentially due to altered biomechanics, except for accessory joint which may act as a stabilizer.


Subject(s)
Axial Spondyloarthritis , Bone Marrow Diseases , Sacroiliitis , Spondylarthritis , Humans , Sacroiliac Joint/diagnostic imaging , Sacroiliitis/diagnostic imaging , Bone Marrow/diagnostic imaging , Retrospective Studies , Bone Marrow Diseases/diagnostic imaging , Bone Marrow Diseases/complications , Magnetic Resonance Imaging/methods , Edema/diagnostic imaging , Edema/complications , Spondylarthritis/diagnostic imaging
5.
Am J Med Genet A ; 194(4): e63486, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38041217

ABSTRACT

Aicardi-Goutières syndrome (AGS) is an autosomal recessive inflammatory syndrome that manifests as an early-onset encephalopathy with both neurologic and extraneurologic clinical findings. AGS has been associated with pathogenic variants in nine genes: TREX1, RNASEH2B, RNASEH2C, RNASEH2A, SAMHD1, ADAR, IFIH1, LSM11, and RNU7-1. Diagnosis is established by clinical findings (encephalopathy and acquired microcephaly, intellectual and physical impairments, dystonia, hepatosplenomegaly, sterile pyrexia, and/or chilblains), characteristic abnormalities on cranial CT (calcification of the basal ganglia and white matter) and MRI (leukodystrophic changes), or the identification of pathogenic/likely pathogenic variants in the known genes. One of the genes associated with AGS, SAMHD1, has also been associated with a spectrum of cerebrovascular diseases, including moyamoya disease (MMD). In this report, we describe a 31-year-old male referred to genetics for MMD since childhood who lacked the hallmark features of AGS patients but was found to have compound heterozygous SAMHD1 variants. He later developed mitral valve insufficiency due to recurrent chordal rupture and ultimately underwent a heart transplant at 37 years of age. Thus, these data suggest that SAMHD1 pathogenic variants can cause MMD without typical AGS symptoms and support that SAMHD1 should be assessed in MMD patients even in the absence of AGS features.


Subject(s)
Autoimmune Diseases of the Nervous System , Brain Diseases , Moyamoya Disease , Nervous System Malformations , Male , Humans , Child , Adult , SAM Domain and HD Domain-Containing Protein 1/genetics , Moyamoya Disease/complications , Mitral Valve/pathology , Mutation , Nervous System Malformations/diagnostic imaging , Nervous System Malformations/genetics , Autoimmune Diseases of the Nervous System/diagnosis , Autoimmune Diseases of the Nervous System/genetics , Autoimmune Diseases of the Nervous System/pathology , Brain Diseases/complications
7.
Pediatr Radiol ; 53(8): 1576-1586, 2023 07.
Article in English | MEDLINE | ID: mdl-36856758

ABSTRACT

MRI is used for early detection of inflammation of sacroiliac joints as it shows active lesions of sacroiliitis long before radiographs show damage to the sacroiliac joints. Early diagnosis of arthritis allows early treatment of inflammation and can help delay disease progression and prevent irreversible damage. Also, early identification of axial involvement in juvenile spondyloarthropathy is crucial, as treatment options are different than for peripheral juvenile spondyloarthropathy. In general, standard sequences used in adults are also applied to children. However, interpreting MR images of pediatric sacroiliac joints is more challenging than in adults, because of normal physiological changes during skeletal maturation, which can simulate disease on MR images. Furthermore, classical definitions of sacroiliitis used in adults, for both active inflammatory and structural lesions, can be difficult to extrapolate to children. The development of reliable pediatric-specific definitions for sacroiliitis is still in active study. Understanding both normal and pathological signal changes in children is important to distinguish physiologic findings from disease and to make a correct diagnosis. In this review, the main imaging characteristics of sacroiliitis on MRI in children and its frequent pitfalls will be illustrated, while also citing some discussion points regarding the scan protocol.


Subject(s)
Arthritis, Juvenile , Sacroiliitis , Spondylarthropathies , Adult , Humans , Child , Sacroiliitis/diagnostic imaging , Magnetic Resonance Imaging/methods , Inflammation , Radiologists
8.
Insights Imaging ; 14(1): 30, 2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36750489

ABSTRACT

BACKGROUND: Synthetic computed tomography (sCT) images are magnetic resonance imaging (MRI)-based images, generated using artificial intelligence. This study aimed to determine the prevalence of anatomical variants of sacroiliac joints (SIJ) on sCT images and the correlation with age, sex and body weight. METHODS: MRI of the SIJ including sCT images of 215 patients clinically suspected for sacroiliitis were retrospectively analyzed. The presence of anatomical variants of the SIJ was assessed. Age, sex and body mass index at the time of the MRI were recorded. RESULTS: SIJ variants were found in 82.8% (356/430) of the evaluated joints. The most frequent variants were iliosacral complex (27.7%), bipartite iliac bony plate (27.2%) and crescent iliac bony plate (27%). One new variant was identified, consisting of an accessory facet of the SIJ on the superior side. Overall, SIJ variants were slightly more frequent in women (85.8% vs. 77.8%), but iliosacral complex was significantly more frequent in men. Isolated synostosis was more prevalent with advancing age, in contrast to semicircular defect and unfused ossification center. The occurrence of iliosacral complex was associated with higher BMI, while crescent iliac bony plate occurred more in patients with lower BMI. CONCLUSION: Over 80% of patients in this study, who were all suspected of sacroiliitis, had at least one SIJ variant. These variants may actually represent subtypes of the normal SIJ. sCT enables detection of very small or subtle findings including SIJ variants.

9.
Eur J Radiol ; 158: 110651, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36535080

ABSTRACT

PURPOSE: To determine the prevalence of incidental findings on sacroiliac joint MRI and to determine the added value of MRI-based synthetic CT in the detection and evaluation of these incidental findings. METHOD: In this retrospective study 210 patients clinically suspected of spondyloarthritis who underwent MRI of the sacroiliac joint with synthetic CT sequence were included. The images were reviewed by two radiologists in consensus for the prevalence of sacroiliitis, incidental findings, and the ability of synthetic CT and the conventional MRI to detect and diagnose these findings. RESULTS: In 44.7% of patients sacroiliitis was present. In 89.0% of patients MRI showed at least one incidental finding other than sacroiliitis. Degeneration of the sacroiliac joint was the most prevalent finding (140 patients, 66.6%). The most frequent incidental findings outside the sacroiliac joint were facet joint degeneration (29.0%), disc degeneration (25.2%), enostosis (19.5%) and lumbosacral transitional vertebrae (14.3%). A total of 788 lesions was recorded and synthetic CT was found to be problem solving or necessary for diagnosis in 543 (68.9%) of these lesions. 42.1% of lesions were not visible on conventional MRI (T1 TSE and STIR), most often degenerative osteophytes in the sacroiliac joint or lower lumbar spine. CONCLUSION: Incidental findings are seen more frequently on sacroiliac joint MRI than sacroiliitis, which is relevant as some will have clinical significance or require treatment. Nearly half of these incidental lesions were only visible on synthetic CT, which additionally has been shown to be problem solving for diagnosis in many other cases.


Subject(s)
Intervertebral Disc Degeneration , Sacroiliitis , Humans , Sacroiliac Joint/diagnostic imaging , Sacroiliac Joint/pathology , Sacroiliitis/diagnostic imaging , Sacroiliitis/epidemiology , Incidental Findings , Retrospective Studies , Magnetic Resonance Imaging/methods , Lumbar Vertebrae/pathology , Intervertebral Disc Degeneration/pathology , Tomography, X-Ray Computed/methods
10.
J Belg Soc Radiol ; 106(1): 123, 2022.
Article in English | MEDLINE | ID: mdl-36475022

ABSTRACT

This review presents an overview of the spectrum of the current and cutting-edge MRI techniques for pelvic bone imaging in clinical practice. The current MRI sequences and their advantages, disadvantages and usefullness in the imaging of this complex anatomical region are addressed. Finally, cutting-edge techniques are discussed, including susceptibility weighted MRI, ultrashort echo time MRI, zero echo time MRI and a deep learning-based multiparametric MRI technique named 'synthetic CT,' creating CT-like images without ionizing radiaton. Main Points: GRE, SWI, UTE, ZTE MRI and synthetic CT sequences depict the cortical outline of the bones better in comparison to conventional MR images.MRI-based synthetic CT can create HU maps and allows for automated segmentation of pelvic bones.The current and cutting-edge MR techniques for bone imaging are complementary in the characterization of a variety of musculoskeletal disorders.

11.
J Belg Soc Radiol ; 106(1): 99, 2022.
Article in English | MEDLINE | ID: mdl-36382019

ABSTRACT

Teaching Point: Intraspinal azygos vein is an extremely rare anatomical variant; knowledge is important for correct imaging interpretation.

12.
Semin Musculoskelet Radiol ; 26(4): 469-477, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36103888

ABSTRACT

The sacrum and sacroiliac joints pose a long-standing challenge for adequate imaging because of their complex anatomical form, oblique orientation, and posterior location in the pelvis, making them subject to superimposition. The sacrum and sacroiliac joints are composed of multiple diverse tissues, further complicating their imaging. Varying imaging techniques are suited to evaluate the sacrum, each with its specific clinical indications, benefits, and drawbacks. New techniques continue to be developed and validated, such as dual-energy computed tomography (CT) and new magnetic resonance imaging (MRI) sequences, for example susceptibility-weighted imaging. Ongoing development of artificial intelligence, such as algorithms allowing reconstruction of MRI-based synthetic CT images, promises even more clinical imaging options.


Subject(s)
Artificial Intelligence , Magnetic Resonance Imaging , Sacrum , Humans , Magnetic Resonance Imaging/methods , Pelvis , Sacroiliac Joint/diagnostic imaging , Sacrum/abnormalities , Sacrum/diagnostic imaging
13.
Invest Radiol ; 57(7): 444-452, 2022 07 01.
Article in English | MEDLINE | ID: mdl-35085123

ABSTRACT

OBJECTIVES: Bedside radiographs are usually obtained gridless, without a physical scatter correction grid because of several limitations. Therefore, multiple manufacturers of mobile radiography systems provide the possibility to apply scatter correction software (SC SW) on those images. The purpose of this study was to characterize different series of radiographs-gridless, SC SW, and physical grid-with an image quality assessment algorithm (IQAA). Furthermore, we investigated the potential dose reduction and the correlation between the output of the IQAA and the human observers. MATERIALS AND METHODS: We obtained different series of radiographs with an anthropomorphic phantom (multipurpose chest phantom N1 "Lungman," Kyoto Kagaku, Kyoto, Japan). All radiographs were obtained with flat-panel detectors of 5 different manufacturers in a wall bucky system. An IQAA to analyze the radiographs was implemented in our department but was originally developed by the research group of the Duke University Medical Center. Seven physical quantities were calculated by the IQAA: rib-lung contrast (RLcontrast), subdiaphragm-lung contrast (SLcontrast), lung detail (Ldetail), mediastinum detail (Mdetail), lung noise (Lnoise), mediastinum noise (Mnoise), and rib-lung sharpness (RLsharpness). In a proof of concept, the results of the IQAA were validated by 3 experienced radiologists. RESULTS: Regression coefficients (b) of the linear regression model indicate that the human observer results correlate well with the IQAA (b ≥ 0.89, R2 ≥ 0.83). All manufacturers have SC SW that increases the 7 physical quantities of the gridless images. However, several manufacturers have SC SW that increases the physical metrics to the same level as the physical grid images. The SC SW radiographs obtained with a reduced tube load have an increased level of contrast, detail, sharpness, and noise compared with the gridless images obtained with the higher tube load. CONCLUSIONS: We have proven in a proof of concept that the originally developed IQAA can be used to characterize different series of images of different manufacturers. Based on the physical quantities, SC SW increases the contrast, detail, sharpness, and noise. The experimental results in this study assume a patient dose reduction could be possible when SC SW is applied.


Subject(s)
Radiography, Thoracic , Software , Humans , Phantoms, Imaging , Radiographic Image Enhancement/methods , Radiography , Radiography, Thoracic/methods , Scattering, Radiation
14.
Clin Neurol Neurosurg ; 203: 106594, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33735661

ABSTRACT

BACKGROUND: Cerebral microbleeds are increasingly reported in critical ill patients with respiratory failure in need of mechanical ventilation and/or extracorporeal membrane oxygenation (ECMO). Typically, these critical illness-associated microbleeds involve the juxtacortical white matter and corpus callosum. Recently, this pattern was reported in patients with respiratory failure, suffering from COVID-19. MATERIALS AND METHODS: In this retrospective single-center study, we listed patients from March 11, 2020 to September 2, 2020, with laboratory-confirmed COVID-19, critical illness and cerebral microbleeds. Literature research was conducted through a methodical search on Pubmed databases on critical illness-associated microbleeds and cerebral microbleeds described in patients with COVID-19. RESULTS AND DISCUSSION: On 279 COVID-19 admissions, two cases of cerebral microbleeds were detected in critical ill patients with respiratory failure due to COVID-19. Based on review of existing literature critical illness-associated microbleeds tend to predominate in subcortical white matter and corpus callosum. Cerebral microbleeds in patients with COVID-19 tend to follow similar patterns as reported in critical illness-associated microbleeds. Hence, one patient with typical critical illness-associated microbleeds and COVID-19 is reported. However, a new pattern of widespread cortico-juxtacortical microbleeds, predominantly in the anterior vascular territory with relative sparing of deep gray matter, corpus callosum and infratentorial structures is documented in a second case. The possible etiologies of these microbleeds include hypoxia, hemorrhagic diathesis, brain endothelial erythrophagocytosis and/or cytokinopathies. An association with COVID-19 remains to be determined. CONCLUSION: Further systematic investigation of microbleed patterns in patients with neurological impairment and COVID-19 is necessary.


Subject(s)
COVID-19/complications , Cerebral Hemorrhage/diagnosis , Cerebral Hemorrhage/etiology , Aged , COVID-19/diagnosis , COVID-19/therapy , Cerebral Hemorrhage/therapy , Critical Illness , Humans , Male , Middle Aged
15.
J Belg Soc Radiol ; 104(1): 10, 2020 Jan 31.
Article in English | MEDLINE | ID: mdl-32025626

ABSTRACT

Teaching Point: Color Doppler ultrasound (US) is useful for screening for renal arteriovenous (AV) shunts, especially following renal biopsy, because of its convenience and minimally invasive nature.

16.
Acta Clin Belg ; 75(4): 267-274, 2020 Aug.
Article in English | MEDLINE | ID: mdl-31081471

ABSTRACT

INTRODUCTION: Stroke is a development of an acute focal neurological deficit with an ischemic or hemorrhagic origin. Thrombolysis within 4.5 h of ischemic stroke onset improves outcome. Guidelines recommend administration of intravenous recombinant tissue plasminogen activator within 60 min upon arrival at the hospital, meaning the door-to-needle time (DNT) should be less than 60 min. In this study, a stroke protocol was introduced at the emergency department of the Ghent University Hospital with a primary goal to shorten the DNT. METHODOLOGY: This study was an uncontrolled before-after cohort study. A 'Code Stroke' protocol (CSP) was implemented and the results from the pre-code stroke protocol period (Pre-CSP period, from 15 August 2016 until 5 March 2017) were compared with the results from the post-code stroke protocol period (Post-CSP period, from 6 March 2017 until 16 July 2017). RESULTS: The median DNT decreased significantly from 57 min in the Pre-CSP period to 33 min in the Post-CSP period (p < 0.001). The door-to-triage time (DTT), triage-to-emergency physician time (TET), emergency physician-to-CT time (ECT) and CT-to needle time (CNT) decreased significantly Post-CSP compared to Pre-CSP. When adjusting the results for other variables that might have an influence on these time intervals, the TET, ECT and CNT also decreased significantly. There was a statistically significant effect of the implementation of the CSP on the number of patients treated with a DNT within 20, 30, 45 and 60 min (p = 0.008). CONCLUSION: A significant decrease in DNT can be achieved with the implementation of this stroke protocol.


Subject(s)
Fibrinolytic Agents/therapeutic use , Ischemic Stroke/drug therapy , Thrombolytic Therapy/statistics & numerical data , Time-to-Treatment/statistics & numerical data , Tissue Plasminogen Activator/therapeutic use , Administration, Intravenous , Aged , Aged, 80 and over , Computed Tomography Angiography , Emergency Medicine , Emergency Nursing , Emergency Service, Hospital/organization & administration , Feasibility Studies , Female , Humans , Ischemic Stroke/diagnostic imaging , Male , Middle Aged , Neurologists , Patient Care Team/organization & administration , Perfusion Imaging , Radiologists , Tomography, X-Ray Computed , Triage/organization & administration
18.
Neuroradiology ; 57(8): 841-9, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25929982

ABSTRACT

INTRODUCTION: Metal artifacts may negatively affect radiologic assessment in the oral cavity. The aim of this study was to evaluate different metal artifact reduction techniques for metal artifacts induced by dental hardware in CT scans of the oral cavity. METHODS: Clinical image quality was assessed using a Thiel-embalmed cadaver. A Catphan phantom and a polymethylmethacrylate (PMMA) phantom were used to evaluate physical-technical image quality parameters such as artifact area, artifact index (AI), and contrast detail (IQFinv). Metal cylinders were inserted in each phantom to create metal artifacts. CT images of both phantoms and the Thiel-embalmed cadaver were acquired on a multislice CT scanner using 80, 100, 120, and 140 kVp; model-based iterative reconstruction (Veo); and synthesized monochromatic keV images with and without metal artifact reduction software (MARs). Four radiologists assessed the clinical image quality, using an image criteria score (ICS). RESULTS: Significant influence of increasing kVp and the use of Veo was found on clinical image quality (p = 0.007 and p = 0.014, respectively). Application of MARs resulted in a smaller artifact area (p < 0.05). However, MARs reconstructed images resulted in lower ICS. CONCLUSION: Of all investigated techniques, Veo shows to be most promising, with a significant improvement of both the clinical and physical-technical image quality without adversely affecting contrast detail. MARs reconstruction in CT images of the oral cavity to reduce dental hardware metallic artifacts is not sufficient and may even adversely influence the image quality.


Subject(s)
Artifacts , Dental Implants , Metals , Mouth/diagnostic imaging , Radiography, Dental/methods , Radiography, Dual-Energy Scanned Projection/methods , Cadaver , Humans , Phantoms, Imaging , Radiation Dosage , Radiography, Dental/instrumentation , Radiography, Dual-Energy Scanned Projection/instrumentation , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods
19.
J Belg Soc Radiol ; 99(2): 16-19, 2015 Dec 30.
Article in English | MEDLINE | ID: mdl-30039099

ABSTRACT

Calcium hydroxyapatite deposition disease is a common pathology, most frequently located in the rotator cuff tendons of the shoulder, for which different therapeutic approaches are used. Ultrasound guided needle lavage and injection of anesthetic/corticosteroid is a well-known and extensively described treatment for calcific tendinits of the rotator cuff. We present a case of bilateral calcific tendinitis of the gluteus medius tendon, both sides successfully treated using ultrasound guided needle lavage of the deposits and injection of an anesthetic and corticosteroid. We propose to not only use this approach for rotator cuff tendons, but also for calcific tendinitis at other locations.