Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 31
Filter
2.
Handchir Mikrochir Plast Chir ; 56(2): 156-165, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38452796

ABSTRACT

BACKGROUND: The European Society of Plastic, Reconstructive and Aesthetic Surgery (ESPRAS) comprises 40 national societies across Europe. In addition to ESPRAS, there are 8 different European Plastic Surgery societies representing Plastic Surgeons in Europe. The 4th European Leadership Forum (ELF) of ESPRAS, held under the motto "Stronger together in Europe" in Munich in 2023, aimed to collect and disseminate information regarding the national member societies of ESPRAS and European societies for Plastic Surgeons. The purpose was to identify synergies and redundancies and promote improved cooperation and exchange to enhance coordinated decision-making at the European level. MATERIAL AND METHODS: An online survey was conducted regarding the organisational structures, objectives and challenges of national and European societies for Plastic Surgeons in Europe. This survey was distributed to official representatives (Presidents, Vice Presidents and General Secretaries) and delegates of national and European societies at the ELF meeting. Missing information was completed using data obtained from the official websites of the respective European societies. Preliminary results were discussed during the 4th ELF meeting in Munich in March 2023. RESULTS: The ESPRAS survey included 22 national and 9 European Plastic Surgery societies representing more than 7000 Plastic Surgeons in Europe. Most national societies consist of less than 500 full members (median 182 members (interquartile range (IQR) 54-400); n=22). European societies, which covered the full spectrum or subspecialities, differed in membership types and congress cycles, with some requiring applications by individuals and others including national societies. The main purposes of the societies include research, representation against other disciplines, specialisation and education as well as more individual goals like patient care and policy regulation. CONCLUSION: This ESPRAS survey offers key insights into the structures, requirements and challenges of national and European societies for Plastic Surgeons, highlighting the relevance of ongoing close exchange between the societies to foster professional advancement and reduce redundancies. Future efforts of the ELF will continue to further explore strategies for enhancing collaboration and harmonisation within the European Plastic Surgery landscape.


Subject(s)
Societies, Medical , Surgery, Plastic , Surgery, Plastic/organization & administration , Europe , Humans , Surveys and Questionnaires , Plastic Surgery Procedures , Leadership , Organizational Objectives
3.
J Hand Surg Eur Vol ; : 17531934241227386, 2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38296229

ABSTRACT

The aim of this Delphi study was to provide a diagnostic and treatment algorithm for patients with persistent or recurrent symptoms after trapeziometacarpal joint resection arthroplasty. Three Delphi rounds were conducted in which surveys were sent to 182 experienced hand surgeons worldwide. Responses were received from 140 participants. A consensus threshold was set at 67% agreement. Diagnostic tools and treatment approaches for six common revision scenarios achieved consensus. Radiographs are appropriate as primary (97%) and CT scans as secondary (76%) diagnostic tools. For scaphometacarpal impingement, 67% of respondents agreed that revision interposition is appropriate, with 93% recommending autologous tendon for the interposition. Additional suspension was considered appropriate by 68% of the participants. The diagnostic and treatment algorithm can help the surgeon to identify the reason for persistent symptoms after trapeziometacarpal joint resection arthroplasty and to choose an appropriate treatment strategy.Level of evidence: V.

4.
J Hand Surg Eur Vol ; 48(5): 383-395, 2023 05.
Article in English | MEDLINE | ID: mdl-36748271

ABSTRACT

The use of three-dimensional (3-D) technology in upper extremity surgery has the potential to revolutionize the way that hand and upper limb procedures are planned and performed. 3-D technology can assist in the diagnosis and treatment of conditions, allowing virtual preoperative planning and surgical templating. 3-D printing can allow the production of patient-specific jigs, instruments and implants, allowing surgeons to plan and perform complex procedures with greater precision and accuracy. Previously, cost has been a barrier to the use of 3-D technology, which is now falling rapidly. This review article will discuss the current status of 3-D technology and printing, including its applications, ethics and challenges in hand and upper limb surgery. We have provided case examples to outline how clinicians can incorporate 3-D technology in their clinical practice for congenital deformities, management of acute fracture and malunion and arthroplasty.


Subject(s)
Fractures, Bone , Surgery, Computer-Assisted , Humans , Fractures, Bone/surgery , Printing, Three-Dimensional , Prostheses and Implants , Arthroplasty , Upper Extremity/surgery
5.
Acta Orthop Belg ; 88(2): 410-417, 2022 Jun.
Article in English | MEDLINE | ID: mdl-36001851

ABSTRACT

The aim of this study is to report the early results of the MatOrtho arthroplasty, a newer generation resurfacing implant of the proximal interphalangeal joint. We performed a prospective cohort review of all MatOrtho arthroplasties implanted between 12/2013 and 05/2018 by a single surgeon at a single institution because of primary osteoarthritis, with a minimum follow-up of two years. Patient demographics, diagnosis, implant revision and other surgical interventions were recorded. Subjective and objective outcomes were evaluated, including range of motion, Patient Reported Outcome Measures and radiographic assessment. A total of 34 implants were inserted in 25 patients. Two implants were lost to follow-up. Pain scores improved significantly (mean VAS pre- op 7, mean VAS post-op 1, p < 0.05). Active range of motion improved in 83% (25/30) of joints, with a mean improvement of the total arc of motion of 25 degrees. On radiographic assessment, no signs of circumferential lucency or subsidence were observed. Additional surgery was necessary for three out of 32 implants, including implant removal in two cases. 93.75% (30/32) implants survived after a mean follow-up of 33 months. Our results confirm that at least at short term follow up, the MatOrtho PIP arthroplasty can be a successful procedure with high patient satisfaction and functional improvement.


Subject(s)
Arthroplasty, Replacement, Finger , Joint Prosthesis , Osteoarthritis , Arthroplasty , Arthroplasty, Replacement, Finger/methods , Finger Joint/diagnostic imaging , Finger Joint/surgery , Follow-Up Studies , Humans , Osteoarthritis/diagnostic imaging , Osteoarthritis/surgery , Prospective Studies , Radiography , Range of Motion, Articular , Retrospective Studies , Treatment Outcome
6.
Handchir Mikrochir Plast Chir ; 54(3): 244-252, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35649427

ABSTRACT

Osteoarthritis of the carpometacarpal joint of the thumb ( CMC-1) is a common problem and many patients will seek medical attention and may eventually need surgical treatment. As no treatment option has shown consistent superiority, a variety of surgical procedures have been proposed. In this review paper we present our algorithm for the approach of symptomatic CMC-1 osteoarthritis, supported by scientific evidence and our personal experience. It is primarily based on patient demands, status of CMC-1 disease and associated problems around the thumb. The selection of a successful surgical treatment plan with restoration of a pain free and fully functional thumb is the goal. We'll outline the pro's and con's of the surgical procedures and although trapeziectomy has long been the gold standard, the advent of reliable total joint arthroplasties with good short and long-term outcome reports has changed our treatment protocol completely.


Subject(s)
Carpometacarpal Joints , Osteoarthritis , Trapezium Bone , Arthroplasty , Carpometacarpal Joints/surgery , Humans , Osteoarthritis/surgery , Thumb/surgery , Trapezium Bone/surgery
7.
EFORT Open Rev ; 7(6): 349-355, 2022 May 31.
Article in English | MEDLINE | ID: mdl-35638603

ABSTRACT

Total joint replacement has certain advantages over other surgical treatment methods for osteoarthritis of the thumb carpometacarpal joint, including restoration of thumb length and alignment, good cosmetical result, fast recovery of hand function and prevention of iatrogenic complications at neighbouring joints. Disadvantages include the technical difficulty to perform this surgery and a possible higher complication rate. A meticulous surgical technique is mandatory. Combined with a cementless and modular ball-in-socket implant with a metal-on-polyethylene friction couple, a 10-year survival rate higher than 90% can be expected. Revision surgery is possible with implant exchange or conversion to trapeziectomy.

8.
J Hand Surg Eur Vol ; 47(6): 562-567, 2022 06.
Article in English | MEDLINE | ID: mdl-35414270

ABSTRACT

COVID-19 has affected us all. The following collection of short essays highlights various aspects of the pandemic and how it has impacted hand surgery and lessons learned, from the perspective of the Federation of European Societies for Surgery of the Hand (FESSH) Executive Committee members. A range of topics were individually chosen by each of the five committee members and presented.


Subject(s)
COVID-19 , Hand Injuries , Orthopedic Procedures , COVID-19/epidemiology , Hand/surgery , Hand Injuries/surgery , Humans , Pandemics
9.
Oper Orthop Traumatol ; 33(3): 228-244, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34003322

ABSTRACT

OBJECTIVE: Osteoarthritis of the carpometacarpal (CMC)-1 joint is a common condition that can cause significant pain and functional problems. When nonoperative management fails, surgery may be indicated. Resection of the trapezium, often combined with soft tissue stabilization, is still considered the gold standard. But recovery time is often prolonged and a significant number of patients remain unsatisfied in the long term. Knowing that total endoprosthetic joint replacement is one of the most successful achievements of orthopedic surgery, many attempts have been made to produce a replacement for the CMC­1 joint that provides a better outcome than trapeziectomy. INDICATIONS: Eaton-Glickel stage 2-3 CMC­1 osteoarthritis. CONTRAINDICATIONS: Symptomatic pan-trapezial osteoarthritis (Eaton-Glickel stage 4), infection, young manual worker, poor bone quality or insufficient trapezium size. SURGICAL TECHNIQUE: A dorsoradial approach to the CMC­1 joint is used. Minimal resection of the trapezial and metacarpal articular surfaces, including osteophytes and loose bodies. Reaming of the trapezium and broaching of the metacarpal stem with dedicated instruments. Implantation of the endoprosthetic components. Selection of the correct neck length to ensure a stable joint. Closure of the capsule and skin. POSTOPERATIVE MANAGEMENT: Immobilization of thumb for 2 weeks in a splint. Followed by a removable thumb CMC brace for 4 weeks, starting with gentle mobilization exercises. No forceful gripping or pinching the first 6 weeks. RESULTS: A specific design-the uncemented, ball in socket, metal on polyethylene total joint replacement-has stood the test of time and successful long-term clinical and radiographic outcome results have been published. Recent comparative trials have shown better pinch strength, better pain relief and faster functional recovery, when compared to trapeziectomy with ligament reconstruction and tendon interposition. The incidence of complications such as dislocation, polyethylene wear and cup loosening is acceptable.


Subject(s)
Carpometacarpal Joints , Trapezium Bone , Carpometacarpal Joints/diagnostic imaging , Carpometacarpal Joints/surgery , Humans , Range of Motion, Articular , Thumb , Trapezium Bone/diagnostic imaging , Trapezium Bone/surgery , Treatment Outcome
11.
J Med Genet ; 58(11): 778-782, 2021 11.
Article in English | MEDLINE | ID: mdl-32900841

ABSTRACT

BACKGROUND: Although carpal tunnel syndrome (CTS) is the most common form of peripheral entrapment neuropathy, its pathogenesis remains largely unknown. An estimated heritability index of 0.46 and an increased familial occurrence indicate that genetic factors must play a role in the pathogenesis. METHODS AND RESULTS: We report on a family in which CTS occurred in subsequent generations at an unusually young age. Additional clinical features included brachydactyly and short Achilles tendons resulting in toe walking in childhood. Using exome sequencing, we identified a heterozygous variant (c.5009T>G; p.Phe1670Cys) in the fibrillin-2 (FBN2) gene that co-segregated with the phenotype in the family. Functional assays showed that the missense variant impaired integrin-mediated cell adhesion and migration. Moreover, we observed an increased transforming growth factor-ß signalling and fibrosis in the carpal tissues of affected individuals. A variant burden test in a large cohort of patients with CTS revealed a significantly increased frequency of rare (6.7% vs 2.5%-3.4%, p<0.001) and high-impact (6.9% vs 2.7%, p<0.001) FBN2 variants in patient alleles compared with controls. CONCLUSION: The identification of a novel FBN2 variant (p.Phe1670Cys) in a unique family with early onset CTS, together with the observed increased frequency of rare and high-impact FBN2 variants in patients with sporadic CTS, strongly suggest a role of FBN2 in the pathogenesis of CTS.


Subject(s)
Carpal Tunnel Syndrome/genetics , Fibrillin-2/genetics , Achilles Tendon/abnormalities , Body Height/genetics , Carpal Tunnel Syndrome/diagnostic imaging , Carpal Tunnel Syndrome/etiology , Humans , Male , Mutation, Missense , Pedigree
13.
EFORT Open Rev ; 4(6): 302-312, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31210970

ABSTRACT

In malunion cases, restoration of anatomy is a key factor in obtaining a good functional outcome, but this can be technically very challenging.Three-dimensional printed bone models can further improve understanding of the malunion pattern.The use of three-dimensional (3D) computer planning, and the assembly of patient-specific instruments and implants, especially in complex deformities of the upper limb, allow accurate correction while reducing operation time, blood loss volume and radiation exposure during surgery.One of the major disadvantages of the 3D technique is the additional cost because it requires specific computer software, a dedicated clinical engineer, and a 3D printer.Further technical developments and clinical investigations are necessary to better define the added value and cost/benefit relationship of 3D in the treatment of complex fractures, non-unions, and malunions. Cite this article: EFORT Open Rev 2019;4 DOI: 10.1302/2058-5241.4.180074.

14.
Eur J Orthop Surg Traumatol ; 28(8): 1531-1535, 2018 Dec.
Article in English | MEDLINE | ID: mdl-29926244

ABSTRACT

Malunion is a common complication of distal radius fractures, especially those treated conservatively. In clinical studies, a significant correlation between anatomic reduction and wrist function has been shown. Corrective osteotomy is the preferred treatment for symptomatic cases, notwithstanding the technical challenges. The use of computer simulation improves pre-operative understanding of the three-dimensional deformity. Patient-specific surgical guides, based on precise pre-operative planning, lead to superior perioperative accuracy and reproducibility. The pre-operative planning and surgical technique of distal radius corrective surgery using three-dimensional computer technology are described in detail. The preliminary results demonstrate the excellent clinical and radiographic outcome of this technique.


Subject(s)
Fractures, Malunited/surgery , Osteotomy/methods , Radius Fractures/surgery , Adolescent , Adult , Aged , Computer Simulation , Female , Fracture Fixation/methods , Fractures, Malunited/physiopathology , Hand Strength/physiology , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Patient Care Planning , Preoperative Care/methods , Prospective Studies , Radius Fractures/physiopathology , Range of Motion, Articular/physiology , Treatment Outcome , Young Adult
16.
J Hand Surg Am ; 42(10): 836.e1-836.e12, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28709790

ABSTRACT

PURPOSE: Three-dimensional planning based on computed tomography images of the malunited and the mirrored contralateral forearm allows preoperative simulations of corrective osteotomies, the fabrication of patient-specific osteotomy guides, and custom-made 3-dimensional printed titanium plates. This study aims to assess the precision and clinical outcome of this technique. METHODS: This was a prospective pilot study with 5 consecutive patients. The mean age at initial injury was 11 years (range, 4-16 years), and the mean interval from the time of injury to the time of corrective surgery was 32 months (range, 7-107 months). Patient-specific osteotomy guides and custom-made plates were used for multiplanar corrective osteotomies of both forearm bones at the distal level in 1 patient and at the middle-third level in 4 patients. Patients were assessed before and after surgery after a mean follow-up of 42 months (range, 29-51 months). RESULTS: The mean planned angular corrections of the ulna and radius before surgery were 9.9° and 10.0°, respectively. The mean postoperative corrections obtained were 10.1° and 10.8° with corresponding mean errors in correction of 1.8° (range, 0.3°-5.2°) for the ulna and 1.4° (range, 0.2°-3.3°) for the radius. Forearm supination improved significantly from 47° (range, 25°-75°) before surgery to 89° (range, 85°-90°) at final review. Forearm pronation improved from 68° (range, 45°-84°) to 87° (range, 82°-90°). In addition, there was a statistically significant improvement in pain and grip strength. CONCLUSIONS: This study demonstrates that 3-dimensional planned patient-specific guides and implants allow the surgeon to perform precise corrective osteotomies of complex multiplanar forearm deformities with satisfactory preliminary results. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic V.


Subject(s)
Fracture Fixation, Internal/instrumentation , Fractures, Malunited/surgery , Internal Fixators , Osteotomy , Radius Fractures/surgery , Ulna Fractures/surgery , Adolescent , Child , Child, Preschool , Diaphyses/injuries , Female , Fractures, Malunited/diagnostic imaging , Humans , Imaging, Three-Dimensional , Male , Pilot Projects , Prospective Studies , Radius Fractures/diagnostic imaging , Surgery, Computer-Assisted , Tomography, X-Ray Computed , Ulna Fractures/diagnostic imaging
17.
J Wrist Surg ; 6(3): 183-187, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28725498

ABSTRACT

Purpose We evaluated clinical and radiographic outcome of percutaneous transtrapezial fixation of the scaphoid delayed union or nonunion using a headless bone screw without bone grafting. Methods Sixteen patients with delayed union or nonunion of the scaphoid were included in this retrospective study between 2006 and 2011. All patients had a delayed presentation of scaphoid fracture, and none of them was treated conservatively elsewhere. Patients with bone graft, sclerotic bone debridement, or displacement of the fragment at the nonunion site were excluded. A percutaneous transtrapezial fixation technique was used in all cases. Patients were reviewed until clinical and radiographic union was observed. At the final follow-up, DASH (Disabilities of the Arm, Shoulder and Hand) and PRWHE (Patient-Rated Wrist and Hand Evaluation) outcome scores were completed. Results Radiographic union was obtained in 15 out of 16 patients (94%) at an average follow-up of 36 months (range: 12-98 months). No complications from the percutaneous technique were noted. The average DASH score was 6 (range: 0-39) and the average PRWHE score was 10 (range: 0-56). No statistical significant difference in range of motion and grip strength was found between the operated side and the contralateral side. Conclusion Percutaneous transtrapezial screw fixation for delayed or nonunion of selected scaphoid fractures without bone grafting is promising. At a mean of 4 months, 94% union was obtained with good functional results when there was no sclerosis, minimal osteolysis, and no displacement at the scaphoid nonunion site. Type of Study Therapeutic study. Level of Evidence IV.

18.
J Wrist Surg ; 6(1): 46-53, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28119795

ABSTRACT

Background The primary objective of this study was to test interobserver reliability when classifying fractures by consensus by AO types and groups among a large international group of surgeons. Secondarily, we assessed the difference in inter- and intraobserver agreement of the AO classification in relation to geographical location, level of training, and subspecialty. Methods A randomized set of radiographic and computed tomographic images from a consecutive series of 96 distal radius fractures (DRFs), treated between October 2010 and April 2013, was classified using an electronic web-based portal by an invited group of participants on two occasions. Results Interobserver reliability was substantial when classifying AO type A fractures but fair and moderate for type B and C fractures, respectively. No difference was observed by location, except for an apparent difference between participants from India and Australia classifying type B fractures. No statistically significant associations were observed comparing interobserver agreement by level of training and no differences were shown comparing subspecialties. Intra-rater reproducibility was "substantial" for fracture types and "fair" for fracture groups with no difference accounting for location, training level, or specialty. Conclusion Improved definition of reliability and reproducibility of this classification may be achieved using large international groups of raters, empowering decision making on which system to utilize. Level of Evidence Level III.

19.
J Hand Surg Am ; 41(9): e279-84, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27497802

ABSTRACT

PURPOSE: In reconstructive surgery of scaphoid nonunions with humpback deformity, some surgeons recommend restoration of the normal scaphoid length whereas others overexpand the normal length to ensure carpal realignment and prevent late collapse. To be able to define overexpansion and investigate which levels of overexpansion yield optimal clinical results, a precise method for estimating the original scaphoid length is required. The purpose of this anatomic study was to investigate the precision of estimating normal scaphoid lengths based on intact adjacent bone dimensions, compared with using the contralateral scaphoid length. METHODS: From bilateral computed tomographic scans of 28 healthy wrist pairs, 3-dimensional virtual bone models were created. The left and right scaphoid lengths were determined at the central axis. The capitate length at the central axis and the distal radius width served to derive an ipsilateral scaphoid length estimate. Estimation precision for individual cases was based on the 95% range (±1.96 × SD) of the observed differences between the actual and estimated lengths. RESULTS: On average, the capitate length was 10% smaller than the scaphoid length; the radius width was 9% larger. Consequently, we averaged the capitate length and radius width for ipsilateral estimations. The average difference between the scaphoid length and the latter ipsilateral estimate was 0.1 mm. The average contralateral scaphoid length difference was also 0.1 mm. Estimation precisions, however, were ±2.2 and ±1.4 mm, respectively. CONCLUSIONS: Scaphoid length estimation based on the contralateral scaphoid is more precise than the estimating scaphoid length using the ipsilateral radius and capitate. CLINICAL RELEVANCE: Scaphoid overexpansion can be ensured if the restored length is at least 1.4 mm longer than the contralateral length. This may be valuable information when establishing a target length for reconstruction and investigating the consequences of scaphoid overexpansion on clinical function, such as range of motion, which are currently unknown.


Subject(s)
Capitate Bone/diagnostic imaging , Radius/diagnostic imaging , Scaphoid Bone/diagnostic imaging , Adult , Body Weights and Measures , Computer Simulation , Female , Healthy Volunteers , Humans , Imaging, Three-Dimensional , Male , Scaphoid Bone/anatomy & histology , Tomography, X-Ray Computed , Wrist/diagnostic imaging , Young Adult
20.
J Bone Joint Surg Am ; 97(10): 850-8, 2015 May 20.
Article in English | MEDLINE | ID: mdl-25995497

ABSTRACT

The ideal position for a screw used for scaphoid fixation is central. The purpose of this study was to compare the current volar percutaneous approaches used for scaphoid fracture fixation, explore different options to improve central screw placement, and describe our experience with the transtrapezial approach.


Subject(s)
Bone Screws , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Scaphoid Bone/injuries , Adult , Aged , Biomechanical Phenomena , Female , Follow-Up Studies , Fracture Fixation, Internal/instrumentation , Fractures, Bone/physiopathology , Humans , Male , Middle Aged , Prosthesis Design , Range of Motion, Articular/physiology , Scaphoid Bone/surgery
SELECTION OF CITATIONS