Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Microsc Microanal ; 29(3): 983-993, 2023 Jun 09.
Article in English | MEDLINE | ID: mdl-37749669

ABSTRACT

Understanding the structural parameters of crystals during crystal growth is essential for the pharmaceutical and chemical industries. This study proposes a new method for 3D images of crystals obtained with micro X-ray computed tomography. This method aims to improve the crystal segmentation compared to the watershed methods. It is based on plane recognition at the surface of the crystals. The obtained segmentation is evaluated on a synthetic image and by considering the recognized particle number and convexity. The algorithm applied to three samples (potassium alum, chromium alum, and copper sulfate) reduced oversegmentation by 87% compared to watershed based on ultimate erosion while keeping the convexity of the recognized particle.

2.
Materials (Basel) ; 15(22)2022 Nov 14.
Article in English | MEDLINE | ID: mdl-36431532

ABSTRACT

Although multiple structural, mechanical, and molecular factors are definitely involved in osteoporosis, the assessment of subregional bone mineral density remains the most commonly used diagnostic index. In this study, we characterized bone quality in the femoral neck of one osteoporotic patients as compared to an age-matched control subject, and so used a multiscale and multimodal approach including X-ray computed microtomography at different spatial resolutions (pixel size: 51.0, 4.95 and 0.9 µm), microindentation and Fourier transform infrared spectroscopy. Our results showed abnormalities in the osteocytes lacunae volume (358.08 ± 165.00 for the osteoporotic sample vs. 287.10 ± 160.00 for the control), whereas a statistical difference was found neither for shape nor for density. The osteoporotic femoral head and great trochanter reported reduced elastic modulus (Es) and hardness (H) compared to the control reference (−48% (p < 0.0001) and −34% (p < 0.0001), respectively for Es and H in the femoral head and −29% (p < 0.01) and −22% (p < 0.05), respectively for Es and H in the great trochanter), whereas the corresponding values in the femoral neck were in the same range. The spectral analysis could distinguish neither subregional differences in the osteoporotic sample nor between the osteoporotic and healthy samples. Although, infrared spectroscopic measurements were comparable among subregions, and so regardless of the bone osteoporotic status, the trabecular mechanical properties were comparable only in the femoral neck. These results illustrate that bone remodeling in osteoporosis is a non-uniform process with different rates in different bone anatomical regions, hence showing the interest of a clear analysis of the bone microarchitecture in the case of patients' osteoporotic evaluation.

3.
Diagnostics (Basel) ; 12(2)2022 Feb 08.
Article in English | MEDLINE | ID: mdl-35204529

ABSTRACT

MRI could be applied for bone microarchitecture assessment; however, this technique is still suffering from low resolution compared to the trabecular dimension. A clear comparative analysis between MRI and X-ray microcomputed tomography (µCT) regarding microarchitecture metrics is still lacking. In this study, we performed a comparative analysis between µCT and 7T MRI with the aim of assessing the image resolution effect on the accuracy of microarchitecture metrics. We also addressed the issue of air bubble artifacts in cadaveric bones. Three fresh cadaveric femur heads were scanned using 7T MRI and µCT at high resolution (0.051 mm). Samples were submitted to a vacuum procedure combined with vibration to reduce the volume of air bubbles. Trabecular interconnectivity, a new metric, and conventional histomorphometric parameters were quantified using MR images and compared to those derived from µCT at full resolution and downsized resolutions (0.102 and 0.153 mm). Correlations between bone morphology and mineral density (BMD) were evaluated. Air bubbles were reduced by 99.8% in 30 min, leaving partial volume effects as the only source of bias. Morphological parameters quantified with 7T MRI were not statistically different (p > 0.01) to those computed from µCT images, with error up to 8% for both bone volume fraction and trabecular spacing. No linear correlation was found between BMD and all morphological parameters except trabecular interconnectivity (R2 = 0.69 for 7T MRI-BMD). These results strongly suggest that 7T MRI could be of interest for in vivo bone microarchitecture assessment, providing additional information about bone health and quality.

4.
Diagnostics (Basel) ; 11(9)2021 Sep 02.
Article in English | MEDLINE | ID: mdl-34573945

ABSTRACT

Trabecular bone could be assessed non-invasively using MRI. However, MRI does not yet provide resolutions lower than trabecular thickness and a comparative analysis between different MRI sequences at different field strengths and X-ray microtomography (µCT) is still missing. In this study, we compared bone microstructure parameters and bone mineral density (BMD) computed using various MRI approaches, i.e., turbo spin echo (TSE) and gradient recalled echo (GRE) images used at different magnetic fields, i.e., 7T and 3T. The corresponding parameters computed from µCT images and BMD derived from dual-energy X-ray absorptiometry (DXA) were used as the ground truth. The correlation between morphological parameters, BMD and fracture load assessed by mechanical compression tests was evaluated. Histomorphometric parameters showed a good agreement between 7T TSE and µCT, with 8% error for trabecular thickness with no significative statistical difference and a good intraclass correlation coefficient (ICC > 0.5) for all the extrapolated parameters. No correlation was found between DXA-BMD and all morphological parameters, except for trabecular interconnectivity (R2 > 0.69). Good correlation (p-value < 0.05) was found between failure load and trabecular interconnectivity (R2 > 0.79). These results suggest that MRI could be of interest for bone microstructure assessment. Moreover, the combination of morphological parameters and BMD could provide a more comprehensive view of bone quality.

5.
Int J Mol Sci ; 22(5)2021 Mar 02.
Article in English | MEDLINE | ID: mdl-33801539

ABSTRACT

Bone microarchitecture has been shown to provide useful information regarding the evaluation of skeleton quality with an added value to areal bone mineral density, which can be used for the diagnosis of several bone diseases. Bone mineral density estimated from dual-energy X-ray absorptiometry (DXA) has shown to be a limited tool to identify patients' risk stratification and therapy delivery. Magnetic resonance imaging (MRI) has been proposed as another technique to assess bone quality and fracture risk by evaluating the bone structure and microarchitecture. To date, MRI is the only completely non-invasive and non-ionizing imaging modality that can assess both cortical and trabecular bone in vivo. In this review article, we reported a survey regarding the clinically relevant information MRI could provide for the assessment of the inner trabecular morphology of different bone segments. The last section will be devoted to the upcoming MRI applications (MR spectroscopy and chemical shift encoding MRI, solid state MRI and quantitative susceptibility mapping), which could provide additional biomarkers for the assessment of bone microarchitecture.


Subject(s)
Bone and Bones/anatomy & histology , Fractures, Bone/pathology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Animals , Bone Density , Humans
6.
Phys Chem Chem Phys ; 21(23): 12360-12371, 2019 Jun 21.
Article in English | MEDLINE | ID: mdl-31140495

ABSTRACT

The electrochemical study of fast catalytic reactions is limited by mass transport when using the conventional electrochemical cell with a rotating disk electrode (RDE). To overcome this issue, it is important to find a new device with improved transport properties that respects electrochemical constraints. We used numerical simulations of computational fluid dynamics to design a new electrochemical cell based on the so-called "jet flow" design for the kinetic studies of catalytic chemical reactions at the surface of an electrode. The new cell is characterized by a high, reliable and uniform mass transport over the electroactive part of its surface. We investigated the effects of the nozzle and the electrode diameters, the nozzle-electrode distance and the Reynolds number on the performance of the jet-electrode in the flow system. Through the optimization of the geometry of this jet electrode cell, we achieved a factor of 3 enhancement in transport compared to the rotating disk electrode. We succeeded in constructing the designed electrode, characterized it with electrochemical techniques, and found an excellent agreement between the transport properties deduced from the numerical simulations and those from the measurements.

7.
Environ Pollut ; 220(Pt B): 1160-1170, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27876222

ABSTRACT

Nanomaterials are increasingly being used to improve the properties and functions of common building materials. A new type of self-cleaning cement incorporating TiO2 nanomaterials (TiO2-NMs) with photocatalytic properties is now marketed. This promising cement might provide air pollution-reducing properties but its environmental impact must be validated. During cement use and aging, an altered surface layer is formed that exhibits increased porosity. The surface layer thickness alteration and porosity increase with the cement degradation rate. The hardened cement paste leaching behavior has been fully documented, but the fate of incorporated TiO2-NMs and their state during/after potential release is currently unknown. In this study, photocatalytic cement pastes with increasing initial porosity were leached at a lab-scale to produce a range of degradation rates concerning the altered layer porosity and thickness. No dissolved Ti was released during leaching, only particulate TiO2-NM release was detected. The extent of release from this batch test simulating accelerated worst-case scenario was limited and ranged from 18.7 ± 2.1 to 33.5 ± 5.1 mg of Ti/m2 of cement after 168 h of leaching. TiO2-NMs released into neutral aquatic media (simulate pH of surface water) were not associated or coated by cement minerals. The TiO2-NM release mechanism is suspected to start from freeing of TiO2-NMs in the altered layer pore network due to partial cement paste dissolution followed by diffusion into the bulk pore solution to the surface. The extent of TiO2-NM release was not solely related to the cement degradation rate.


Subject(s)
Construction Materials/analysis , Environmental Exposure/analysis , Environmental Pollutants/analysis , Environmental Pollutants/chemistry , Nanostructures/analysis , Nanostructures/chemistry , Titanium/analysis , Titanium/chemistry , Industrial Waste/analysis , Porosity , Rivers/chemistry , Water Pollutants, Chemical/analysis , Water Pollutants, Chemical/chemistry
8.
Microsc Microanal ; 21(5): 1361-71, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26289618

ABSTRACT

This work presents a series of three-dimensional computational methods with the objective of analyzing and quantifying some important structural characteristics in a collection of low-density polyolefin-based foams. First, the solid phase tortuosity, local thickness, and surface curvature, have been determined over the solid phase of the foam. These parameters were used to quantify the presence of wrinkles located at the cell walls of the foams under study. In addition, a novel segmentation technique has been applied to the continuous solid phase. This novel method allows performing a separate analysis of the constituting elements of this phase, that is, cell struts and cell walls. The methodology is based on a solid classification algorithm and evaluates the local topological dissimilarities existing between these elements. Thanks to this method it was possible to perform a separate analysis of curvature, local thickness, and corrugation ratio in the solid constituents that reveals additional differences that were not detected in the first analysis of the continuous structure. The methods developed in this work are applicable to other types of porous materials in fields such as geoscience or biomedicine.

9.
Ann Otol Rhinol Laryngol ; 121(12): 821-6, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23342556

ABSTRACT

OBJECTIVES: In previous work, we showed that a rigid larynx-like geometry can generate a sound by itself. However, very little is known about the exact mechanisms and control of the larynx during the first cry of life. The goal of this work was to understand how the very first cry is generated. METHODS: Simultaneous high-speed imaging and sound recording on 2 excised 38-week term human fetus larynges were performed. The behaviors of the vocal folds and the false vocal folds were studied separately. The behavior of the vocal folds after resection of the supraglottic structures was also analyzed. A comparative acoustic analysis of the first cry and of the sound generated by the excised organs was performed. RESULTS: Our data showed that the vocal folds in a larynx with the pressure conditions of the first cry do not generate sound themselves, but induce aerodynamic conditions leading to vibrations of other parts of the larynx. CONCLUSIONS: The similarities between the sound generated by an excised larynx and the first cry suggest a lack of neurologic control of the larynx during production of the first cry. A model-algorithm is proposed.


Subject(s)
Crying/physiology , Infant, Newborn/physiology , Larynx/physiology , Fourier Analysis , Humans , Models, Biological , Parturition/physiology , Sound , Vibration , Vocal Cords/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...