1.
Healthcare (Basel) ; 11(24)2023 Dec 08.
Article in English | MEDLINE | ID: mdl-38132013

ABSTRACT

PURPOSE: Treatment of scaphoid fracture sequelae is still an unsolved problem in hand surgery. Custom-made 3D-printed titanium partial and total scaphoid prosthesis and scaphoid interosseous ligament reconstruction (SLIL) are performed in cases of non-union and isolated aseptic necrosis of the proximal scaphoid pole and when it is impossible to save the scaphoid bone, respectively. This study aims to evaluate the clinical, functional and radiographic results after these two prosthesis implantations. METHODS: Between January 2019 and July 2020, nine partial and ten total scaphoid prostheses were implanted using custom-made 3D-printed titanium implants. Evaluation criteria included carpal height ratio (CHR), radioscaphoid angle, wrist extension and flexion, radial deviation and ulnar deviation of the wrist, grip strength and pinch strength, Visual Analogue Scale (VAS), the Disabilities of Arm, Shoulder, and Hand (DASH) score, and the Patient-Rated Wrist Evaluation (PRWE). RESULTS: Clinical, functional, and radiographic improvements were found in all outcomes analyzed for both patient groups. The VAS pain scale obtained the most remarkable improvement at the one-year follow-up. The results of the DASH scores and the PRWE were good, with a great rate of patient satisfaction at the end of the follow-up. SLIL reconstruction also provided excellent stability and prevented a mid-carpal bone collapse in the short- and medium-term follow-up. CONCLUSIONS: A custom-made 3D-printed titanium partial or total scaphoid prosthesis is a viable solution for patients with scaphoid non-union and necrosis or complete scaphoid destruction in whom previous conservative or surgical treatment has failed.

2.
Polymers (Basel) ; 15(16)2023 Aug 14.
Article in English | MEDLINE | ID: mdl-37631456

ABSTRACT

The utilization of a planar poly(1,4-butylene succinate) (PBS) scaffold has been demonstrated as an effective approach for preserving nerve continuity and facilitating nerve regeneration. In this study, we assessed the characteristics of a microfibrous tubular scaffold specifically designed and fabricated through electrospinning, utilizing PBS as a biocompatible and biodegradable material. These scaffolds were evaluated as nerve guide conduits in a rat model of sciatic nerve neurotmesis, demonstrating both their biodegradability and efficacy in enhancing the reconstruction process over a long-term period (1-year follow-up). Histological assay and electrophysiological evaluation were performed to compare the long-term outcomes following sutureless repair with the microfibrillar wrap to outcomes obtained using traditional suture repair.

3.
J Clin Med ; 11(9)2022 May 07.
Article in English | MEDLINE | ID: mdl-35566755

ABSTRACT

A peri-implant fracture near the volar plate of the distal radius represents a rarity and can be associated with a mechanical failure of the devices. A literature review was conducted including all fractures that occurred around a volar wrist plate, which could be associated with an ulna fracture. All articles published until December 2021 were considered according to the guidelines presented in the PRISMA Statement. The search was conducted with the PubMed electronic database, Cochrane Database of Systematic Reviews, Medline, Embase, and Google Scholar. Only nine cases of these fractures were reported in the literature. The causes could be due to delayed union/non-union of the old fracture after low energy traumas, high energy trauma in patients with poor bone quality, or hardware mechanical failure. Furthermore, the literature review of peri-implant radius fracture shows different level of radius fracture and types of implant failure. In accordance with these different cases, a new classification of peri-implant fracture of the distal radius is proposed.

4.
J Funct Biomater ; 14(1)2022 Dec 30.
Article in English | MEDLINE | ID: mdl-36662069

ABSTRACT

The treatment of extensive bone loss represents a great challenge for orthopaedic and reconstructive surgery. Most of the time, those treatments consist of multiple-stage surgeries over a prolonged period, pose significant infectious risks and carry the possibility of rejection. In this study, we investigated if the use of a polybutylene succinate (PBS) micro-fibrillar scaffold may improve bone regeneration in these procedures. In an in vivo rabbit model, the healing of two calvarial bone defects was studied. One defect was left to heal spontaneously while the other was treated with a PBS scaffold. Computed tomography (CT) scans, histological and immunohistochemical analyses were performed at 4, 12 and 24 weeks. CT examination showed a significantly larger area of mineralised tissue in the treated defect. Histological examination confirmed a greater presence of active osteoblasts and mineralised tissue in the scaffold-treated defect, with no evidence of inflammatory infiltrates around it. Immunohistochemical analysis was positive for CD56 at the transition point between healthy bone and the fracture zone. This study demonstrates that the use of a PBS microfibrillar scaffold in critical bone defects on a rabbit model is a potentially effective technique to improve bone regeneration.

5.
Geriatr Orthop Surg Rehabil ; 12: 2151459321991503, 2021.
Article in English | MEDLINE | ID: mdl-33623723

ABSTRACT

In patients over 65y.o. who were surgically treated for a hip fracture, electrolytes have not been specifically studied as predictors of mortality. The main purpose of this study was to assess whether electrolytes and chronic kidney disease (CKD) stages, evaluated at admission, could represent a pre-operative prognostic factor in this population. Moreover, the role of epidemiological and clinical parameters was analyzed with and without a surgical timing stratification. This retrospective study included 746 patients. For each patient, their age, gender, fracture classification, Hb value, comorbidities, ASA class, chronic kidney disease, creatinine levels, electrolytes and surgical timing were collected. CKD-epi, MDRD, modified MDRD and BIS1 were used to obtain eGFR and CKD stages. All parameters were analyzed individually and in relation to the different surgical timing. Descriptive statistics, Chi-square test and survivability analysis with Kaplan Meier curve were used. In patients with a hip fracture non-significant association with increased mortality was shown for the following variables: Hb value, sodium values, calcium values, CKD stages and creatinine values. Otherwise altered kalemia was associated with a statistically significant increase in mortality as well as male gender, two or more comorbid medical conditions, advanced age (>75 years), higher ASA class. Surgery performed within 72h resulted in a statistically significant reduction in mortality at 6 months and, when performed in 24h-48h, a further reduction at 4 years. Age and ASA class statistically significant increased mortality regardless the surgical timing. Male patients operated after 48h from hospitalization were associated with a statistically significant increase in mortality rate. Two or more comorbidities were related to a statistically significant increased number of deaths when patients were treated after 96h. Altered kalemia values at hospitalization are associated with a statistically significant increase in mortality in patients operated after 72h from admission.

6.
Trauma Case Rep ; 31: 100387, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33344743

ABSTRACT

A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the frequency of these kind of fracture will probably increase.