Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 95
Filter
1.
J Am Heart Assoc ; 13(10): e033605, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742523

ABSTRACT

BACKGROUND: Minimally invasive mitral valve repair has a favorable risk-benefit profile in patients with significant de novo mitral regurgitation. Its role in patients with prior mitral valve repair is uncertain. We aimed to appraise the outcome of patients undergoing transcatheter edge-to-edge repair (TEER) with prior transcatheter or surgical mitral valve repair (SMVR). METHODS AND RESULTS: We queried the Italian multicenter registry on TEER with MitraClip, distinguishing naïve patients from those with prior TEER or (SMVR). Inhospital and long-term clinical/echocardiographic outcomes were appraised. The primary outcome was the occurrence of death or rehospitalization for heart failure. A total of 2238 patients were included, with 2169 (96.9%) who were naïve to any mitral intervention, 29 (1.3%) with prior TEER, and 40 (1.8%) with prior SMVR. Several significant differences were found in baseline clinical and imaging features. Respectively, device success was obtained in 2120 (97.7%), 28 (96.6%), and 38 (95.0%, P=0.261) patients; procedural success in 2080 (95.9%), 25 (86.2%), and 38 (95.0%; P=0.047); and inhospital death in 61 (2.8%), 1 (3.5%), and no (P=0.558) patients. Clinical follow-up after a mean of 14 months showed similar rates of death, cardiac death, rehospitalization, rehospitalization for heart failure, and their composite (all P>0.05). Propensity score-adjusted analysis confirmed unadjusted analysis, with lower procedural success for the prior TEER group (odds ratio, 0.28 [95% CI, 0.09-0.81]; P=0.019) but similar odds ratios and hazard ratios for all other outcomes in the naïve, TEER, and SMVR groups (all P>0.05). CONCLUSIONS: In carefully selected patients, TEER can be performed using the MitraClip device even after prior TEER or SMVR.


Subject(s)
Cardiac Catheterization , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Mitral Valve , Registries , Humans , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Male , Female , Aged , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Mitral Valve/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Italy/epidemiology , Aged, 80 and over , Patient Readmission/statistics & numerical data , Treatment Failure , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Annuloplasty/adverse effects , Treatment Outcome , Time Factors , Risk Factors , Heart Failure/mortality , Heart Failure/physiopathology , Heart Failure/surgery
2.
Article in English | MEDLINE | ID: mdl-38749449

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: To identify the incidence, predictors, and clinical outcomes of PVR following TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with severe Sievers type 1 BAV stenosis undergoing TAVR with current generation transcatheter heart valves (THVs) in 24 international centres were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAE), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%): mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were larger virtual raphe ring (VRR) perimeter (ORadj 1.07, 95% CI 1.02-1.13), severe annular or left ventricular outflow tract (LVOT) calcification (ORadj 5.21, 95% CI 1.45-18.77), self-expanding valve (ORadj 9.01, 95% CI 2.09-38.86), and intentional supra-annular THV positioning (ORadj 3.31, 95% CI 1.04-10.54). At a median follow-up of 1.3 [IQR 0.5-2.4] years, moderate or severe PVR was associated with an increased risk of MAE (HRadj 2.52, 95% CI 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAE during follow-up.

3.
Article in English | MEDLINE | ID: mdl-38775458

ABSTRACT

OBJECTIVES: Ascending aorta (AA) dilatation in patients with bicuspid aortic valve (AV) is related both to genetic and haemodynamic factors. The aim of this study is to compare late progression of AA dilatation in bicuspid AV patients undergoing surgical aortic valve replacement (SAVR) versus transcatheter aortic valve implantation (TAVI). METHODS: Data of 189 consecutive patients who underwent AV replacement for severe bicuspid AV stenosis were prospectively collected. Patients who underwent SAVR were compared to patients who underwent TAVI. Indication to the procedure was validated by the institutional Heart Team. Aortic diameters were evaluated by transthoracic echocardiogram. Differences between preoperative and long-term follow-up AA diameters were compared in the 2 groups. RESULTS: Between January 2015 and December 2021, 143 (76%) patients underwent SAVR and 46 (24%) patients underwent TAVI. At 4.6 (standard deviation 1.7) years follow-up, patients in the TAVI group showed significantly lower survival (P = 0.00013) and event-free survival (P < 0.0001). AA diameter progression was lower in surgical compared to transcatheter patients, 0.95 (0.60, 1.30) vs 1.65 (0.67, 2.63) mm, P = 0.02. AA diameter progression indexed for body surface area and height was lower in the surgical group: 0.72 (0.38, 1.05) vs 1.05 (0.39, 1.71) mm/m2, P = 0.02, and 0.59 (0.36, 0.81) vs 1.11 (0.44, 1.78) mm/m, P = 0.001, respectively. At multivariable linear regression analysis transcatheter procedure, baseline aortic diameter and paravalvular leak were significantly associated with increased postoperative AA dilatation. CONCLUSIONS: Bicuspid AV patients who underwent SAVR, showed significantly less long-term AA diameter progression than patients who underwent transcatheter procedure.

4.
J Invasive Cardiol ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38598251

ABSTRACT

OBJECTIVES: Transcatheter edge-to-edge repair (TEER) has become an established minimally invasive treatment for significant mitral regurgitation. Ongoing refinements and the availability of different clipping devices have expanded the indications for and effectiveness of TEER, but comprehensive comparative data on this issue are lacking. In this study, we compared NT, NTr, and XTr MitraClip devices (Abbot) for TEER. METHODS: Details on patient, imaging, and procedural details, as well as short- and long-term outcomes, were sought from a national prospective clinical registry on TEER with MitraClip. The primary outcome of interest was discharge after procedural success without major clinical complications. RESULTS: A total of 2236 patients were included, 1228 (54.9%) in whom NT implantation only was attempted, 233 (10.4%) in whom NTr but not XTr implantation was attempted, and 775 (34.7%) in whom XTr implantation was attempted. Clinical and imaging features differed substantially across the groups, reflecting expanding indications with NTr and XTr devices. In-hospital outcomes were largely similar among the 3 groups, including death. Long-term unadjusted estimates of effect showed significant differences in several outcomes, including death, rehospitalization, and their composite, which demonstrated that NT was associated with more unfavorable outcomes compared with the other devices (all P less than .05). However, most differences depended on baseline features, as adjusted analysis showed no significant differences for early as well as long-term outcomes, including long-term death, rehospitalization, and their composite (all P greater than .05). CONCLUSIONS: New-generation MitraClip devices are associated with favorable procedural and clinical outcomes, despite being used in patients with more adverse features, when compared with patients treated with previous devices.

6.
Am J Cardiol ; 211: 219-227, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-37944779

ABSTRACT

Atrial functional mitral regurgitation (aFMR) has a peculiar pathophysiology that may have distinctive outcomes. We investigated the impact of transcatheter edge-to-edge repair in aFMR compared with other FMR etiologies. The GIOTTO (GIse registry Of Transcatheter treatment of MR) is a multicenter, prospective study enrolling patients with symptomatic MR treated with MitraClip up to 2020. We categorized patients with FMR as aFMR, ischemic FMR (iFMR), and nonischemic ventricular FMR (niFMR). The clinical end points were defined according to the Mitral Valve Academic Research Consortium. Of 1,153 patients, 6% had aFMR, 47% iFMR, and 47% niFMR. Patients with aFMR were older, mostly women, and had a higher atrial fibrillation rate. They had better left ventricular ejection fraction and smaller left ventricular volumes, with no difference in mitral effective regurgitant orifice area. The acute device and procedural success rates were similar among the groups. At the longest available follow-up (median 478 days, interquartile range 91 to 741 days), the rate of MR ≥2+ was similar among the groups. Patients with aFMR had a lower rate of cardiovascular death and heart failure than patients with iFMR (hazard ratio [HR] 0.43, p = 0.02) and niFMR (HR 0.45, p = 0.03). The aFMR etiology remained independently associated with the composite outcome, together with postprocedural MR ≤1+ (HR 0.63, p <0.01) and peripheral arteriopathy (HR 1.82, p = 0.003). The results of this GIOTTO subanalysis suggested that aFMR is less prevalent and associated with better outcomes compared with other causes of FMR treated by transcatheter edge-to-edge repair. Postprocedural MR >1+, peripheral vasculopathy, non-aFMR were independent predictors of worse outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Female , Male , Mitral Valve/surgery , Stroke Volume , Prospective Studies , Ventricular Function, Left , Registries , Treatment Outcome , Heart Valve Prosthesis Implantation/methods
7.
Cardiovasc Revasc Med ; 62: 40-47, 2024 May.
Article in English | MEDLINE | ID: mdl-38135568

ABSTRACT

BACKGROUND: Vascular complications (VCs) still represent one of the principal concerns of trans-femoral trans-catheter aortic valve replacement (TF-TAVR). New-generation devices can minimize such complications but the arterial access management is left to the operator's choice. This study aims to describe the rate of VCs in a contemporary cohort of patients undergoing TAVR with new-generation devices and to determine whether an ultrasound-guided (USG) vs. a fluoroscopy-guided (FG) femoral access management has an impact on their prevention. METHODS: This is a prospective, observational, multicenter study. Consecutive patients undergoing TAVR with new-generation devices were analyzed from January 2022 to October 2022 in five tertiary care centers. Femoral accesses were managed according to the operator's preferences. All the patients underwent a pre-discharge peripheral ultrasound control. VCs and bleedings were the main endpoints of interest. RESULTS: A total of 458 consecutive patients were enrolled (274 in the USG group and 184 in the FG group). VCs occurred in 6.5 % of the patients (5.2 % minor and 1.3 % major). There was no difference between the USG and the FG groups in terms of any VCs (7.3 % vs. 5.4 %; p = 0.4), or any VARC-3 bleedings (6.9 % vs 6 %, p = 0.9). At logistic regression analysis, the two guidance strategies did not result as predictors of VCs (odds Ratio 0.8, 95 % Confidence Interval 0.46-1.4; P = 0.4). CONCLUSIONS: In a contemporary cohort of patients undergoing TAVR with new-generation devices, the occurrence of VCs is low and mostly represented by minor VCs. USG and FG modalities did not affect the rate of VCs.


Subject(s)
Aortic Valve , Catheterization, Peripheral , Femoral Artery , Punctures , Radiography, Interventional , Registries , Transcatheter Aortic Valve Replacement , Ultrasonography, Interventional , Humans , Femoral Artery/diagnostic imaging , Male , Female , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aged , Fluoroscopy , Treatment Outcome , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Risk Factors , Radiography, Interventional/adverse effects , Heart Valve Prosthesis , Time Factors , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Prosthesis Design
8.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Article in English | MEDLINE | ID: mdl-37946539

ABSTRACT

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Kaplan-Meier Estimate , Multivariate Analysis , Patients , Treatment Outcome , Cardiac Catheterization
9.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37331223

ABSTRACT

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Prognosis , Treatment Outcome , Proportional Hazards Models , Heart Failure/complications , Death , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects
10.
Panminerva Med ; 65(4): 443-453, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37259492

ABSTRACT

BACKGROUND: The clinical impact of coronary artery disease (CAD) on the prognosis of patients undergoing MitraClip implantation is still unclear. METHODS: One thousand nine hundred fifty-three patients undergoing MitraClip implantation included in the multicenter GIOTTO Registry were stratified according to CAD. Endpoints were all-cause death, cardiac death, and re-hospitalization for heart failure at follow-up (median 15.8 months). RESULTS: Although younger, CAD patients were more symptomatic, had worse cardiovascular risk profile, higher burden of comorbidities, more frequently affected by functional MR, with higher left ventricle (LV) diameters and lower ejection fraction (EF). At follow-up, CAD patients showed higher rates of all-cause death (25.4% vs. 19.6%; P=0.002), cardiovascular death (14.0% vs. 10.1%; P=0.007) and re-hospitalization for heart failure (13.9% vs. 10.2%; P=0.011). Dividing the population according to mitral regurgitation (MR) etiology (functional vs. non-functional MR), no differences were observed between CAD and no-CAD patients. At multivariate logistic regression, NYHA III/IV class, prior heart failure hospitalization, severe chronic kidney disease, atrial fibrillation, LV end-diastolic diameter and LVEF<30% but not CAD resulted independent predictors of all-cause death. The same finding was confirmed even after propensity score adjustment. CONCLUSIONS: CAD did not show a relevant impact on mid-term prognosis per se, but seemed to identify a more complex and diseased cohort of patients with worse clinical and functional status.


Subject(s)
Coronary Artery Disease , Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Coronary Artery Disease/complications , Coronary Artery Disease/surgery , Heart Failure/complications , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Mitral Valve/surgery , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Treatment Outcome
11.
Artif Organs ; 47(8): 1386-1394, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37039965

ABSTRACT

BACKGROUND: Post-acute myocardial infarction papillary muscle rupture (post-AMI PMR) may present variable clinical scenarios and degree of emergency due to result of cardiogenic shock. Veno-arterial extracorporeal life support (V-A ECLS) has been proposed to improve extremely poor pre- or postoperative conditions. Information in this respect is scarce. METHODS: From the CAUTION (meChanical complicAtion of acUte myocardial infarcTion: an InternatiOnal multiceNter cohort study) database (16 different Centers, data from 2001 to 2018), we extracted adult patients who were surgically treated for post-AMI PMR and underwent pre- or/and postoperative V-A ECLS support. The end-points of this study were in-hospital survival and ECLS complications. RESULTS: From a total of 214 post-AMI PMR patients submitted to surgery, V-A ECLS was instituted in 23 (11%) patients. The median age was 61.7 years (range 46-81 years). Preoperatively, ECLS was commenced in 10 patients (43.5%), whereas intra/postoperative in the remaining 13. The most common V-A ECLS indication was post-cardiotomy shock, followed by preoperative cardiogenic shock and cardiac arrest. The median duration of V-A ECLS was 4 days. V-A ECLS complications occurred in more than half of the patients. Overall, in-hospital mortality was 39.2% (9/23), compared to 22% (42/219) for the non-ECLS group. CONCLUSIONS: In post-AMI PMR patients, V-A ECLS was used in almost 10% of the patients either to promote bridge to surgery or as postoperative support. Further investigations are required to better evaluate a potential for increased use and its effects of V-A ECLS in such a context based on the still high perioperative mortality.


Subject(s)
Cardiomyopathies , Extracorporeal Membrane Oxygenation , Heart Valve Diseases , Myocardial Infarction , Adult , Humans , Middle Aged , Aged , Aged, 80 and over , Extracorporeal Membrane Oxygenation/methods , Shock, Cardiogenic/etiology , Shock, Cardiogenic/surgery , Cohort Studies , Papillary Muscles/surgery , Myocardial Infarction/complications , Cardiomyopathies/complications , Heart Valve Diseases/complications
12.
J Cardiovasc Surg (Torino) ; 64(3): 338-347, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37078984

ABSTRACT

BACKGROUND: The increasing use of biological substitutes for surgical aortic valve replacement (AVR), has led to the development of new bioprostheses with improved hemodynamics and expected durability. METHODS: In this observational retrospective two-center cohort study, two innovative bioprostheses, INSPIRIS Resilia and AVALUS were analyzed. We analyzed early and 2.4-year follow-up results in terms of safety, clinical outcome and hemodynamic performance. RESULTS: From November 2017 to February 2021, 148 patients underwent AVR with INSPIRIS Resilia (N.=74) or AVALUS (N.=74) bioprosthesis. The 30-day and mid-term mortality was comparable (1% vs. 3%, P=0.1 and 7% vs. 4%, P=0.4, respectively). Valve-related mortality was observed in one AVALUS patient. Three (4%) patients of the AVALUS group developed prosthetic endocarditis and two of them died after reoperation. No other cases of prosthetic endocarditis were observed. No cases of structural valve degeneration or significant paravalvular leak were detected at follow-up. Median follow-up peak pressure gradient was 21 vs. 23 mmHg (P=0.4) and the mean pressure gradient was 12 vs. 13 mmHg (P=0.9) for Inspiris and AVALUS, respectively. The effective orifice area (EOA) and indexed EOA were 1.5 cm2 vs. 1.4 cm2 (P=0.4) and 0.8 vs. 0.7 cm2/m2 (P=0.5), respectively. Indexed left ventricular mass regression was -33 vs. -52 g/m2 for the Inspiris and AVALUS groups, respectively, (R2-adjusted =0.14; P<0.01). CONCLUSIONS: INSPIRIS Resilia and AVALUS bioprostheses were reliable with comparable results in safety, clinical outcome and hemodynamic performance. After statistical adjustment, AVALUS was associated with better left ventricular mass reduction. Long-term follow-up would provide definitive comparative results.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Retrospective Studies , Cohort Studies , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemodynamics , Prosthesis Design , Treatment Outcome
14.
EuroIntervention ; 18(17): 1408-1417, 2023 Apr 24.
Article in English | MEDLINE | ID: mdl-36809256

ABSTRACT

BACKGROUND: A risk score was recently derived from the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) Trial. However, external validation of this score is still lacking. AIMS: We aimed to validate the COAPT risk score in a large multicentre population undergoing mitral transcatheter edge-to-edge repair (M-TEER) for secondary mitral regurgitation (SMR). METHODS: The Italian Society of Interventional Cardiology (GIse) Registry of Transcatheter Treatment of Mitral Valve RegurgitaTiOn (GIOTTO) population was stratified according to COAPT score quartiles. The performance of the COAPT score for 2-year all-cause death or heart failure (HF) hospitalisation was evaluated in the overall population and in patients with or without a COAPT-like profile. RESULTS: Among the 1,659 patients included in the GIOTTO registry, 934 had SMR and complete data for a COAPT risk score calculation. The incidence of 2-year all-cause death or HF hospitalisation progressively increased through the COAPT score quartiles in the overall population (26.4% vs 44.5% vs 49.4% vs 59.7%; log-rank p<0.001) and COAPT-like patients (24.7% vs 32.4% vs 52.3% vs. 53.4%; log-rank p=0.004), but not in those with a non-COAPT-like profile. The COAPT risk score had poor discrimination and good calibration in the overall population, moderate discrimination and good calibration in COAPT-like patients and very poor discrimination and poor calibration in non-COAPT-like patients. CONCLUSIONS: The COAPT risk score has a poor performance in the prognostic stratification of real-world patients undergoing M-TEER. However, after application to patients with a COAPT-like profile, moderate discrimination and good calibration were observed.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Risk Factors , Hospitalization , Treatment Outcome
15.
Thorac Cardiovasc Surg ; 71(7): 557-565, 2023 10.
Article in English | MEDLINE | ID: mdl-36257545

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the need for postoperative permanent pacemaker implantation (PPI) following sutureless and rapid-deployment aortic valve replacement (SuRD-AVR) in the context of a progress report from a large multicenter international registry (SURD-IR). METHODS: We retrospectively analyzed 4,166 patients who underwent SuRD-AVR between 2008 and 2019. The primary outcome was the need for PPI before discharge. The study population was analyzed separately according to the implanted prostheses (Su cohort and RD cohort). Each cohort was divided into two groups based on the operation date: an early group ("EG" = 2008-2016) and a late group ("LG" = 2017-2019). RESULTS: The rate of PPI decreased significantly in the Su cohort over time (EG = 10.8% vs LG = 6.3%, p < 0.001). In the Su cohort, a decrease in age, risk profile, and incidence of bicuspid aortic valve, increased use of anterior right thoracotomy, reduction of cardiopulmonary bypass time and of associated procedures, and more frequent use of smaller prostheses were observed over time. In the RD cohort, the rate of PPI was stable over time (EG = 8.8% vs LG = 9.3%, p = 0.8). In this cohort, a younger age, lower risk profile, and higher incidence of concomitant septal myectomy were observed over time. CONCLUSION: Our analysis showed a significant decrease in the PPI rate in patients who underwent Su-AVR over time. Patient selection as well as surgical improvements and a more accurate sizing could be correlated with this phenomenon. The RD cohort revealed no significant differences either in patient's characteristics or in PPI rate between the two time periods.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pacemaker, Artificial , Sutureless Surgical Procedures , Humans , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Retrospective Studies , Research Report , Treatment Outcome , Prosthesis Design , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Sutureless Surgical Procedures/adverse effects
16.
Am J Cardiol ; 186: 100-108, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36356428

ABSTRACT

Up to half of real-world patients with secondary mitral regurgitation who underwent transcatheter edge-to-edge repair (TEER) do not meet the highly selective COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation) criteria. No randomized trials or standardized and validated tools exist to evaluate the risk: benefit ratio of TEER in this specific population. We sought to derive and externally validate a clinical risk score to predict the risk of death or heart failure (HF) hospitalization for COAPT-ineligible patients who underwent TEER (CITE score). The study population consisted of patients with secondary mitral regurgitation having at least 1 exclusion criterion of the COAPT trial. The derivation cohort included 489 patients from the GIOTTO (GIse registry of Transcatheter treatment of Mitral Valve regurgitaTiOn) registry. Cox proportional hazards regression was used to identify predictors of 2-year death/HF hospitalization and develop a numerical risk score. The predictive performance was assessed in the derivation cohort and validated in 268 patients from the MiZüBr (Milan-Zürich-Brescia) registry. The CITE score (hemodynamic instability, left ventricular impairment, New York Heart Association class III/IV, peripheral artery disease, atrial fibrillation, brain natriuretic peptide, and hemoglobin) showed a c-index for 2-year death or HF hospitalization of 0.70 (95% confidence interval [CI] 0.67 to 0.73) in the derivation cohort, and 0.68 (95% CI 0.64 to 0.73) in the validation cohort. A cutoff of <12 points was selected to identify patients at lower risk of adverse outcomes, hazard ratio of 0.35 (95% CI 0.26 to 0.46). In conclusion, the CITE score is a simple 7-item tool for the prediction of death or HF hospitalization at 2 years after TEER in COAPT-ineligible patients. The score may support clinical decision-making by identifying those patients who, even if excluded from clinical trials, can still benefit from TEER.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Natriuretic Peptide, Brain , Risk Factors , Treatment Outcome
17.
J Clin Med ; 13(1)2023 Dec 27.
Article in English | MEDLINE | ID: mdl-38202159

ABSTRACT

BACKGROUND: Infective endocarditis (IE) is a serious disease, and in many cases, surgery is necessary. Whether the type of prosthesis implanted for aortic valve replacement (AVR) for IE impacts patient survival is a matter of debate. The aim of the present study is to quantify differences in long-term survival and recurrence of endocarditis AVR for IE according to prosthesis type among patients aged 40 to 65 years. METHODS: This was an analysis of the INFECT-REGISTRY. Trends in proportion to the use of mechanical prostheses versus biological ones over time were tested by applying the sieve bootstrapped t-test. Confounders were adjusted using the optimal full-matching propensity score. The difference in overall survival was compared using the Cox model, whereas the differences in recurrence of endocarditis were evaluated using the Gray test. RESULTS: Overall, 4365 patients were diagnosed and operated on for IE from 2000 to 2021. Of these, 549, aged between 40 and 65 years, underwent AVR. A total of 268 (48.8%) received mechanical prostheses, and 281 (51.2%) received biological ones. A significant trend in the reduction of implantation of mechanical vs. biological prostheses was observed during the study period (p < 0.0001). Long-term survival was significantly higher among patients receiving a mechanical prosthesis than those receiving a biological prosthesis (hazard ratio [HR] 0.546, 95% CI: 0.322-0.926, p = 0.025). Mechanical prostheses were associated with significantly less recurrent endocarditis after AVR than biological prostheses (HR 0.268, 95%CI: 0.077-0.933, p = 0.039). CONCLUSIONS: The present analysis of the INFECT-REGISTRY shows increased survival and reduced recurrence of endocarditis after a mechanical aortic valve prosthesis implant for IE in middle-aged patients.

18.
Am J Cardiol ; 182: 46-54, 2022 11 01.
Article in English | MEDLINE | ID: mdl-36075753

ABSTRACT

Despite being highly effective in reducing residual mitral regurgitation and improving outcomes, mitral valve transcatheter edge-to-edge repair (MV-TEER) may be associated with high postprocedural residual mitral gradient (rMG). Conflicting results have been reported regarding the relation between rMG and adverse events. This study aimed to evaluate the predictors and the impact of elevated rMG after MV-TEER on clinical events in patients with functional mitral regurgitation (FMR) at 2 years follow-up. We selected a cohort of 864 patients with FMR who were treated with MV-TEER enrolled in the multicentre Italian Society of Interventional Cardiology (GISE) registry of transcatheter treatment of mitral valve regurgitation (GIOTTO). Patients were stratified into tertiles according to rMG. The primary clinical end point was a composite of all-cause death and hospitalization because of heart failure at 2-year follow-up. Overall, 269 patients (31.5%) with an rMG <3 mm Hg, 259 (30.3%) with an rMG ≥3/<4 mm Hg, and 326 (38.2%) with an rMG ≥4 mm Hg were considered. At multivariate logistic regression, ischemic FMR etiology, baseline MG, and the number of implanted clips were independent predictors of an rMG ≥4 mm Hg. Clinical follow-up was available in 570 patients (63.2%). Patients with an rMG ≥4 mm Hg experienced higher rates of the composite end point than patients of the other tertiles (51.1%, vs 42.3% vs 40.8% log-rank test: p = 0.033). In multivariate Cox's regression, both rMG ≥4 mm Hg (hazard ratio 1.54, 95% confidence interval 1.14 to 2.08) and residual mitral regurgitation ≥2+ (hazard ratio 1.36, 95% confidence interval 1.01 to 1.83) were independent predictors of adverse events at 2-year follow-up. In conclusion, we demonstrated that real-world patients who underwent MV-TEER who show an rMG ≥4 mm Hg are at higher risk of death or hospitalization because of heart failure during a 2-year follow-up. Further studies will be needed to confirm our results.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Cardiac Catheterization/methods , Disease Progression , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/surgery , Treatment Outcome
19.
J Cardiovasc Med (Hagerstown) ; 23(6): 406-413, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35645032

ABSTRACT

AIMS: To compare early and late mortality of acute isolated tricuspid valve infective endocarditis (TVIE) treated with valve repair or replacement. METHODS: Patients who were surgically treated for TVIE from 1983 to 2018 were retrieved from the Italian Registry for Surgical Treatment of Valve and Prosthesis Infective Endocarditis. All the patients were followed up by means of phone interview or calling patient referral physicians or cardiologists. Kaplan-Meier method was used to assess late survival and survival free from TVIE recurrence with log-rank test for univariate comparison. The primary end points were early mortality (30 days after surgery) and long-term survival free from TVIE recurrence. RESULTS: A total of 4084 patients were included in the registry. Among them, 149 patients were included in the study. Overall, 77 (51.7%) underwent TV repair and 72 (48.3%) TV replacement. Early mortality was 9% (13 patients). Expected early mortality according to EndoSCORE was 12%. The TV repair showed lower mortality and major complication rate (7% and 16%), compared with TV replacement (11% and 25%), but statistical significance was not reached. Median follow-up was 19.1 years (14.3-23.8). Late deaths were 30 and IE recurrences were 5. No difference in cardiac survival free from IE was found between the two groups after 20 years (80 ±â€Š6% Repair Group vs 59 ±â€Š13% Replacement Group, P = 0.3). CONCLUSIONS: Overall results indicate that once surgically addressed, TVIE has a low recurrence rate and excellent survival, apparently regardless of the type of surgery used to treat it.


Subject(s)
Cardiac Surgical Procedures , Endocarditis, Bacterial , Endocarditis , Cardiac Surgical Procedures/adverse effects , Endocarditis/surgery , Endocarditis, Bacterial/surgery , Humans , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery
20.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Article in English | MEDLINE | ID: mdl-35595675

ABSTRACT

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Hemodynamics , Humans , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...