Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
Add more filters










Publication year range
1.
Opt Express ; 29(20): 31714-31725, 2021 Sep 27.
Article in English | MEDLINE | ID: mdl-34615259

ABSTRACT

We have experimentally demonstrated the post-compression of a long-wave infrared (9.2 µm) 150 GW peak power pulse from 2 ps to less than 500 fs using a sequence of two bulk materials with negative group velocity dispersion (GVD). The compression resulted in up to 1.6-fold increase of the peak power and up to 2.8-fold increase of the intensity in the center of a quasi-Gaussian beam. The partial decoupling of the self-phase modulation and chirp compensation stages by using two materials with significantly different ratios of nonlinear refractive index to GVD provides accurate optimization of the compression mechanism and promises a viable path to scaling peak powers to supra-terawatt levels. During the preparatory study, we measured, for the first time to our knowledge, the nonlinear refractive indices of NaCl, KCl, and BaF2 for picosecond pulses in the long-wave infrared region.

2.
Opt Lett ; 46(9): 2067-2070, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33929420

ABSTRACT

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a well-defined, high-quality beam from a comparatively non-uniform quasi-flat-top beam, which is typical for high-peak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, to the best of our knowledge, yielding n2=3.0×10-23m2/W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

3.
Opt Lett ; 43(1): 21, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-29328223

ABSTRACT

This erratum reports a correction to the labeling of Figs. 2(b) and 3(b) in the original manuscript, Opt. Lett.42, 4756 (2017)OPLEDP0146-959210.1364/OL.42.004756.

4.
Opt Lett ; 42(22): 4756-4759, 2017 11 15.
Article in English | MEDLINE | ID: mdl-29140361

ABSTRACT

We report an octave-wide mid-IR spectrum (2.3-4.8 µm) obtained from a subharmonic optical parametric oscillator (OPO) based on a newly developed nonlinear crystal, orientation-patterned gallium phosphide (OP-GaP), which was synchronously pumped by a femtosecond 1560 nm fiber laser. We proved that the octave-wide output is in the form of a single frequency comb. The observed f-to-2f frequency beats, originating directly from the OPO, can be used for self-referencing and phase locking of the pump laser comb with no need for supercontinuum generation. With an average output power of ∼30 mW, this setup might be beneficial for a variety of spectroscopic applications in the mid-IR.

5.
Opt Express ; 25(19): 22404-22410, 2017 Sep 18.
Article in English | MEDLINE | ID: mdl-29041551

ABSTRACT

We demonstrated two liquid crystal diffractive waveplates: one optimized for near-infrared (1.06 µm), and another for mid-wave infrared (MWIR, 3~5 µm). By employing a low loss liquid crystal mixture UCF-M3, whose absorption loss is below 2% in the 4~5 µm spectral region, the grating achieves over 98% diffraction efficiency in a broad MWIR range. To switch the grating, both active and passive driving methods can be considered. In our experiment, we used a polymer-stabilized twisted nematic cell as the polarization rotator for passive driving. The obtained rise time is 0.2 ms and decay time is 10 ms.

6.
Appl Opt ; 55(23): 6321-30, 2016 Aug 10.
Article in English | MEDLINE | ID: mdl-27534474

ABSTRACT

Dual-comb spectroscopy (DCS) has shown unparalleled advantages but at the cost of highly mutual coherence between comb lasers. Here, we investigate spectral degradation induced by laser frequency instabilities and improvement benefited from active laser stabilization. Mathematical models of DCS in the cases of direct radio-frequency (RF) locking and optical phase stabilization were separately established first. Numerical simulations are utilized to study the impact of laser intrinsic stability and the improvement by different locking strategies on spectral performance in the following. Finally, both simulations are proven by corresponding experiments. It shows that an optically phase-stabilized system owns a better immunity of laser frequency fluctuations than a direct RF-stabilized one. Furthermore, the performance improvement by the feedback servos is also more effective in the optically phase-stabilized system. In addition, the simulations could instruct optimal design and system improvement.

7.
Opt Lett ; 39(7): 2056-9, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-24686673

ABSTRACT

We observe the coherence of the supercontinuum generated in a nanospike chalcogenide-silica hybrid waveguide pumped at 2 µm. The supercontinuum is shown to be coherent with the pump by interfering it with a doubly resonant optical parametric oscillator (OPO) that is itself coherent with the shared pump laser. This enables coherent locking of the OPO to the optically referenced pump frequency comb, resulting in a composite frequency comb with wavelengths from 1 to 6 µm.

8.
Opt Lett ; 39(4): 900-3, 2014 Feb 15.
Article in English | MEDLINE | ID: mdl-24562236

ABSTRACT

We demonstrate a mid-IR frequency comb centered at 3120 nm with 650-nm (20-THz) bandwidth at a comb-teeth spacing of 500 MHz. The generated comb is based on a compact ring-type synchronously pumped optical parametric oscillator (SPOPO) operating at degeneracy and pumped by a mode-locked Er-doped 1560 nm fiber laser at a repetition rate of 100 MHz. We achieve high-repetition rate by using a fractional-length cavity with a roundtrip length of 60 cm, which is one-fifth of the length dictated by conventional synchronous pumping.

9.
Opt Lett ; 38(15): 2865-8, 2013 Aug 01.
Article in English | MEDLINE | ID: mdl-23903165

ABSTRACT

We report a supercontinuum spanning well over an octave of measurable bandwidth from about 1 to 3.7 µm in a 2.1 mm long As2S3 fiber taper using the in situ tapering method. A sub-100-fs mode-locked thulium-doped fiber laser system with ~300 pJ of pulse energy was used as the pump source. Third-harmonic generation was observed and currently limits the pump pulse energy and achievable spectral bandwidth.

10.
J Vis Exp ; (75): e50518, 2013 May 27.
Article in English | MEDLINE | ID: mdl-23748947

ABSTRACT

Supercontinuum generation (SCG) in a tapered chalcogenide fiber is desirable for broadening mid-infrared (or mid-IR, roughly the 2-20 µm wavelength range) frequency combs(1, 2) for applications such as molecular fingerprinting, (3) trace gas detection, (4) laser-driven particle acceleration, (5) and x-ray production via high harmonic generation. (6) Achieving efficient SCG in a tapered optical fiber requires precise control of the group velocity dispersion (GVD) and the temporal properties of the optical pulses at the beginning of the fiber, (7) which depend strongly on the geometry of the taper. (8) Due to variations in the tapering setup and procedure for successive SCG experiments-such as fiber length, tapering environment temperature, or power coupled into the fiber, in-situ spectral monitoring of the SCG is necessary to optimize the output spectrum for a single experiment. In-situ fiber tapering for SCG consists of coupling the pump source through the fiber to be tapered to a spectral measurement device. The fiber is then tapered while the spectral measurement signal is observed in real-time. When the signal reaches its peak, the tapering is stopped. The in-situ tapering procedure allows for generation of a stable, octave-spanning, mid-IR frequency comb from the sub harmonic of a commercially available near-IR frequency comb. (9) This method lowers cost due to the reduction in time and materials required to fabricate an optimal taper with a waist length of only 2 mm. The in-situ tapering technique can be extended to optimizing microstructured optical fiber (MOF) for SCG(10) or tuning of the passband of MOFs, (11) optimizing tapered fiber pairs for fused fiber couplers(12) and wavelength division multiplexers (WDMs), (13) or modifying dispersion compensation for compression or stretching of optical pulses.(14-16.)


Subject(s)
Arsenicals/chemistry , Chalcogens/chemistry , Fiber Optic Technology/instrumentation , Optical Fibers , Sulfides/chemistry , Fiber Optic Technology/methods , Infrared Rays
11.
Opt Lett ; 38(8): 1191-3, 2013 Apr 15.
Article in English | MEDLINE | ID: mdl-23595427

ABSTRACT

We measure the carrier envelope offset (CEO) frequency of the mid-infrared frequency comb (wavelength tunable between 3 and 6 µm) from a doubly resonant nondegenerate synchronously pumped optical parametric oscillator (SPOPO) as a function of the CEO frequency of the Tm-fiber pump laser. We show that the CEO frequency of the SPOPO signal wave is a linear function of the CEO frequency of the pump laser, with a slope determined by the signal to pump center-frequency ratio.

12.
Opt Express ; 20(25): 27589-95, 2012 Dec 03.
Article in English | MEDLINE | ID: mdl-23262708

ABSTRACT

We report generation of 48 fs pulses at a center wavelength of 2070 nm using a degenerate optical parametric oscillator (OPO) synchronously-pumped with a commercially available 36-MHz, femtosecond, mode-locked, Yb-doped fiber laser. The spectral bandwidth of the output is ~137 nm, corresponding to a theoretical, transform-limited pulse width of 33 fs. The threshold of the OPO is less than 10 mW of average pump power. By tuning the cavity length, the output spectrum covers a spectral width of more than 400 nm, limited only by the bandwidth of the cavity mirrors.


Subject(s)
Lasers, Solid-State , Oscillometry/instrumentation , Oscillometry/methods , Equipment Design , Nonlinear Dynamics , Refractometry/instrumentation , Refractometry/methods , Transducers , Ytterbium/chemistry
13.
Opt Express ; 20(22): 24218-25, 2012 Oct 22.
Article in English | MEDLINE | ID: mdl-23187184

ABSTRACT

We demonstrate mid-infrared (mid-IR) supercontinuum generation (SCG) with instantaneous bandwidth from 2.2 to 5 µm at 40 dB below the peak, covering the wavelength range desirable for molecular spectroscopy and numerous other applications. The SCG occurs in a tapered As(2)S(3) fiber prepared by in-situ tapering and is pumped by femtosecond pulses from the subharmonic of a mode-locked Er-doped fiber laser. Interference with a narrow linewidth c.w. laser verifies that the coherence properties of the near-IR frequency comb have been preserved through these cascaded nonlinear processes. With this approach stable broad mid-IR frequency combs can be derived from commercially available near-IR frequency combs without an extra stabilization mechanism.

14.
Opt Express ; 20(17): 19322-30, 2012 Aug 13.
Article in English | MEDLINE | ID: mdl-23038574

ABSTRACT

We demonstrate a novel all-optical quantum random number generator (RNG) based on above-threshold binary phase state selection in a degenerate optical parametric oscillator (OPO). Photodetection is not a part of the random process, and no post processing is required for the generated bit sequence. We show that the outcome is statistically random with 99% confidence, and verify that the randomness is due to the phase of initiating photons generated through spontaneous parametric down conversion of the pump, with negligible contribution of classical noise sources. With the use of micro- and nanoscale OPO resonators, this technique offers a promise for simple, robust, and high-speed on-chip all-optical quantum RNGs.


Subject(s)
Amplifiers, Electronic , Lasers , Oscillometry/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Random Allocation
15.
Opt Express ; 20(7): 7046-53, 2012 Mar 26.
Article in English | MEDLINE | ID: mdl-22453385

ABSTRACT

We report the extension of broadband degenerate OPO operation further into mid-infrared. A femtosecond thulium fiber laser with output centered at 2050 nm synchronously pumps a 500-µm-long crystal of orientation patterned GaAs providing broadband gain centered at 4.1 µm. We observe a pump threshold of 17 mW and output bandwidth extending from 2.6 to 6.1 µm at the -30 dB level. Average output power was 37 mW. Appropriate resonator group dispersion is a key factor for achieving degenerate operation with instantaneously broad bandwidth. The output spectrum is very sensitive to absorption and dispersion introduced by molecular species inside the OPO cavity.


Subject(s)
Fiber Optic Technology/instrumentation , Lasers, Solid-State , Equipment Design , Equipment Failure Analysis
16.
Opt Express ; 20(7): 7255-62, 2012 Mar 26.
Article in English | MEDLINE | ID: mdl-22453407

ABSTRACT

We study coherence properties of a χ(²) optical parametric oscillator (OPO), which produces 2/3-octave-wide spectrum centered at the subharmonic (3120 nm) of the femtosecond pump laser. Our method consists of interfering the outputs of two identical, but independent OPOs pumped by the same laser. We demonstrate that the two OPOs show stable spatial and temporal interference and are mutually locked in frequency and in phase. By observing a collective heterodyne beat signal between the two OPOs we show that one can deterministically choose, by cavity length adjustment, between the two frequency states corresponding to the two sets of modes shifted with respect to each other by half of the laser pulse repetition rate. Moreover, we observe that the existence of two opposite phase states, a known common feature of a parametrically driven n = 2 subharmonic oscillator, reveals itself in our experiment as a common phase, 0 or π, being established through the whole set of some 300 thousand longitudinal modes.


Subject(s)
Amplifiers, Electronic , Lasers, Solid-State , Oscillometry/instrumentation , Equipment Design , Equipment Failure Analysis , Infrared Rays
17.
Opt Express ; 19(7): 6296-302, 2011 Mar 28.
Article in English | MEDLINE | ID: mdl-21451655

ABSTRACT

We present a new technique suitable for generating broadband phase- and frequency-locked frequency combs in the mid-infrared. Our source is based on a degenerate optical parametric oscillator (OPO) which rigorously both down-converts and augments the spectrum of a pump frequency comb provided by a commercial mode-locked near-IR laser. Low intracavity dispersion, combined with extensive cross-mixing of comb components, results in extremely broad instantaneous mid-IR bandwidths. We achieve an output power of 60 mW and 20 dB bandwidth extending from 2500 to 3800 nm. Among other applications, such a source is well-suited for coherent Fourier-transform spectroscopy in the absorption-rich mid-IR 'molecular fingerprint' region.


Subject(s)
Filtration/instrumentation , Lasers , Oscillometry/instrumentation , Spectroscopy, Fourier Transform Infrared/instrumentation , Equipment Design , Equipment Failure Analysis , Infrared Rays
18.
Appl Opt ; 49(24): 4489-93, 2010 Aug 20.
Article in English | MEDLINE | ID: mdl-20733617

ABSTRACT

The intracavity signal and idler pulses of a low-loss synchronously pumped doubly resonant optical parametric oscillator were characterized experimentally and simulated numerically versus cavity-length detuning. At operation several hundreds of times above threshold, the detunings that maximize the intracavity average power do not necessarily maximize the temporal overlap of the signal and idler pulses, as is desirable for devices making use of intracavity mixing. Independent control of the signal and idler cavity lengths allowed control of the widths and temporal positioning of the pulses. Numerical studies were performed exploring the intracavity power and temporal overlap of the signal and idler pulses under various group-velocity-mismatch conditions. There was good agreement between the experimental and numerical simulation results.

19.
Opt Express ; 17(16): 13502-15, 2009 Aug 03.
Article in English | MEDLINE | ID: mdl-19654758

ABSTRACT

A metallic slot waveguide, with a dielectric strip embedded within, is investigated for the purpose of enhancing the optics-to-THz conversion efficiency using the difference-frequency generation (DFG) process. To describe the frequency conversion process in such lossy waveguides, a fully-vectorial coupled-mode theory is developed. Using the coupled-mode theory, we outline the basic theoretical requirements for efficient frequency conversion, which include the needs to achieve large coupling coefficients, phase matching, and low propagation loss for both the optical and THz waves. Following these requirements, a metallic waveguide is designed by considering the trade-off between modal confinement and propagation loss. Our numerical calculation shows that the conversion efficiency in these waveguide structures can be more than one order of magnitude larger than what has been achieved using dielectric waveguides. Based on the distinct impact of the slot width on the optical and THz modal dispersion, we propose a two-step method to realize the phase matching for general pump wavelengths.


Subject(s)
Metals/chemistry , Optical Devices , Refractometry/instrumentation , Surface Plasmon Resonance/instrumentation , Terahertz Imaging/instrumentation , Transducers , Computer Simulation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis , Light , Models, Theoretical , Scattering, Radiation , Terahertz Radiation
20.
Opt Lett ; 33(16): 1896-8, 2008 Aug 15.
Article in English | MEDLINE | ID: mdl-18709125

ABSTRACT

We demonstrated a stable degenerate synchronously pumped femtosecond optical parametric oscillator (SPOPO) as a divide-by-2 subharmonic generator. The SPOPO exhibited passive all-optical self-phase-locking between the pump and signal/idler and thus required no external electronic feedback to produce the phase-locked subharmonic. We employed a type I phase-matched, 1-mm-long, periodically poled MgO:LiNbO3 crystal as the nonlinear gain element and an 80 MHz mode-locked Ti:sapphire laser with 180 fs pulses tuned at 775 nm as the pump. The SPOPO generated transform-limited 70 fs phase-locked output pulses centered at 1550 nm. The self-phase-locking operation was confirmed by separate beat-note measurement techniques with respect to the pump laser and with respect to an external cw laser.

SELECTION OF CITATIONS
SEARCH DETAIL
...