Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 51
Filter
1.
J Dent ; 149: 105314, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39168231

ABSTRACT

OBJECTIVES: The fluorescence-aided identification technique (FIT) is based on the fluorescence properties of dental materials, specifically the intensity of their fluorescence compared to the autofluorescence of hard dental substances; this creates a perceived contrast between dental material and tooth. However, no studies to date have determined the extent to which the fluorescence intensity of tooth-colored dental materials must differ from that of natural autofluorescence to ensure reliable visual detection. The aim of this study was therefore to determine, for the first time, how pronounced the difference between fluorescence intensity and autofluorescence must be to reliably identify tooth-colored material. METHODS: Ten dentists assessed six different resin-based composite (RBC) samples of varying fluorescence intensity placed in the cavities of ten extracted teeth under standardized fluorescence-exciting illumination. The outcome variable was fluorescence perceptibility. Their assessments of the outcome variable were compared with measurements of the fluorescence intensities of the RBCs and the surrounding dental hard tissues, which were expressed as a fluorescence intensity ratio. Demographic data of the participants, including age, gender, and professional experience, were also recorded. RESULTS: No significant differences were found for visual fluorescence perceptibility in relation to the explanatory variables of gender (p = 0.14), age (p = 0.13), and professional experience (p = 0.34). In contrast, the fluorescence intensity ratio was significantly different (p < 0.0001). SIGNIFICANCE: For both clinicians and manufacturers, fluorescence intensity levels are important when selecting or developing FIT-compatible materials. Our results suggest that the fluorescence intensity levels of dental materials should be no more than 75% and no less than 200% of tooth natural autofluorescence to ensure reliable detection of tooth-colored materials.


Subject(s)
Composite Resins , Humans , Fluorescence , Male , Female , Composite Resins/chemistry , Adult , Dental Materials/chemistry , Middle Aged , Tooth/diagnostic imaging , Tooth/chemistry , Color
2.
J Clin Med ; 13(14)2024 Jul 11.
Article in English | MEDLINE | ID: mdl-39064106

ABSTRACT

Objectives: To investigate whether phakia affects the outcome of XEN-45 gel stent implantation in the treatment of pseudoexfoliative glaucoma (PXG). Methods: A retrospective, comparative cohort study of 30 phakic and 55 pseudophakic PXG patients who received the XEN-45 gel stent at a tertiary centre. The primary outcome measure was two-year success defined as a ≥20% lowering of intraocular pressure (IOP) and a target IOP of 6-21 mmHg. Success was complete without and qualified irrespective of antiglaucoma medication use. Further glaucoma surgery other than needling was regarded as a failure. The secondary outcome measures included changes in IOP, revision and complication rates. Results: The complete two-year success rates were 70% and 59% in the phakic and pseudophakic groups, respectively (p = 0.75, log-rank test), and the qualified rates were 80% and 72%, respectively (p = 0.89). The median IOP reduction from baseline was 54% in phakic, and 46% in pseudophakic eyes. While needling rates were similar, the incidence of early incisional bleb revisions was significantly higher in the phakic eyes (13% vs. 0% within 3 months; p = 0.0098, chi-square). Increasing after a year, significantly more pseudophakic eyes failed due to secondary glaucoma surgery (16% vs. 0%; p = 0.0191). Conclusions: The XEN-45 gel stent offers equally effective IOP control for both phakic and pseudophakic patients. However, the onset of bleb revisions and the necessity for secondary glaucoma surgery differed significantly between the groups.

3.
BMC Ophthalmol ; 24(1): 264, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38902667

ABSTRACT

BACKGROUND: Minimally invasive bleb surgery using the XEN-45 gel stent has not been established for the treatment of normal-tension glaucoma (NTG). The main objective of this study was to evaluate the long-term treatment efficacy and safety of XEN-45 in eyes with uncontrolled NTG. METHODS: A retrospective analysis of patients with NTG who underwent XEN-45 gel stent implantation at university hospital Tuebingen between 2016 and 2021. The primary outcome measure was surgical success after three years defined as lowering of intraocular pressure (IOP) of ≥ 20%, with target IOP between 6 and 15 mmHg. Success was complete without and qualified irrespective of topical antiglaucoma medication use. The need for further glaucoma surgery, except for needling, was regarded as a failure. The secondary outcome measures included changes in mean IOP, number of antiglaucoma medications, and needling and complication rates. RESULTS: Twenty-eight eyes from 23 patients were included in the final analysis. Complete and qualified success rates were 56.5% and 75% after three years, respectively. Mean postoperative IOP ± standard deviation decreased significantly after three years from 19.3 ± 2.0 mmHg at baseline to 13.7 ± 4.2 mmHg (n = 22; p < 0.0001). The median number of antiglaucoma medications decreased from 2 (range 0-4) to 0 after three years (range 0-3; p < 0.0001). Sixteen eyes (57%) required a median of 1 (range 1-3) needling procedures. One eye required further glaucoma surgery. No sight-threatening complications were observed. CONCLUSION: The XEN-45 stent is effective and safe for the long-term treatment of NTG. However, needling was frequently required to improve outcomes.


Subject(s)
Glaucoma Drainage Implants , Intraocular Pressure , Low Tension Glaucoma , Stents , Humans , Male , Female , Retrospective Studies , Intraocular Pressure/physiology , Low Tension Glaucoma/surgery , Low Tension Glaucoma/physiopathology , Aged , Middle Aged , Treatment Outcome , Follow-Up Studies , Visual Acuity/physiology , Prosthesis Design , Prosthesis Implantation/methods , Aged, 80 and over
4.
Eur J Ophthalmol ; : 11206721241261093, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38850039

ABSTRACT

PURPOSE: To investigate safety and efficacy of the XEN gel stent in patients with pigmentary glaucoma (PG). METHODS: A retrospective analysis of 26 eyes of 19 patients with PG undergoing XEN gel stent implantation was performed. Best-corrected visual acuity, intraocular pressure (IOP), and number of antiglaucoma medications were analyzed preoperatively, and at 2 weeks and 3, 6, 12, and 24 months after surgery. Success, needling, and complications were analyzed. Complete success was defined as an IOP reduction of >20% and achieving a target IOP of ≤18, ≤15, or ≤12 mmHg without antiglaucoma medication. Qualified success was indicated if the IOP target was reached with or without medication. RESULTS: Mean IOP decreased significantly from 27.6 ± 14.3 (standard deviation, SD) mmHg to 14.3 ± 4.6 mmHg after one year (p < 0.001) and 15.1 ± 2.7 mmHg (p < 0.001) after two years. The median number of hypotensive drugs declined significantly from 4 (range: 3-5) to 0 (0-2) and 0 (0-3) after one and two years, respectively. After two years, complete success with an IOP of ≤18 mmHg and ≤15 mmHg was achieved in 73.1% and 61.5%, respectively. Half of the eyes required needling after a median time of 8 months (0.5-34 months). No sight-threatening complications were observed. CONCLUSION: The XEN gel stent is a safe and effective surgical treatment option for PG. Needling is an important part of the procedure and should be communicated preoperatively to the patients.

5.
Article in English | MEDLINE | ID: mdl-38771337

ABSTRACT

INTRODUCTION: Preserflo MicroShunt is a novel microinvasive bleb forming device for the treatment of primary open-angle glaucoma. The intermediate- and long-term success and the impact of this procedure on corneal endothelial cell density remain to be investigated. METHODS: In this prospective observational study, 62 eyes of 55 glaucoma patients (mean age ± SD: 67.0 ± 15.0 years) receiving a Preserflo MicroShunt were included. Corneal endothelial cell density, intraocular pressure and best corrected visual acuity were assessed preoperatively and at 3, 6, 9, 12, 18 and 24 months postoperatively. Success rates, bleb revision rates and complications were analysed. Complete success was defined as an intraocular pressure reduction of ≥ 20% and achieving a target pressure of ≤ 18, ≤ 15 or ≤ 12 mmHg without antiglaucoma medication. Qualified success indicated that the criteria were reached with or without medication. RESULTS: Corneal endothelial cells showed no significant decline over 24 months (p > 0.05). Intraocular pressure showed a substantial reduction postoperatively (p < 0.001), decreasing from 29.6 ± 8,3 mmHg to 13.0 ± 4.3 mmHg after 24 months (p < 0.001). Complete and qualified success with a target pressure ≤ 15 mmHg was achieved in 52.9% and 54.6% of cases after 24 months, respectively. Best corrected visual acuity did not change after 24 months. CONCLUSION: Preserflo MicroShunt had no negative side effects on corneal endothelial cells and showed favourable success rates after 2 years in patients with open-angle glaucoma.

6.
Graefes Arch Clin Exp Ophthalmol ; 262(9): 2977-2984, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38625448

ABSTRACT

PURPOSE: The success of XEN Gel Stent (XEN) and Preserflo MicroShunt (Preserflo) implantation depends mainly on the development of bleb fibrosis. This study aimed to describe the histological findings of bleb fibrosis after XEN and Preserflo surgery. METHODS: This retrospective study included patients with different types of glaucoma who underwent revision surgery after XEN or Preserflo implantation. The available clinical information and histological samples of removed fibrotic tissue were analyzed. RESULTS: Thirty-six patients were included. Revision surgery was performed at a median of 195 (range = 31-1264) days after primary surgery. The mean intraocular pressure changed from 29.1 (± 10.3) mmHg at baseline to 18.3 (± 8.7) mmHg (- 37%; p < 0.0001) and 16.2 (± 4.2) mmHg (- 45%; p < 0.0001) after 6 and 12 months, respectively. Histological analysis revealed an increase in activated fibroblasts and macrophages in all specimens and a parallel orientation of fibroblasts in a minor part of the probe in 60% of the specimens. No pronounced inflammatory reaction in the form of lymphocytic or granulocytic infiltration was observed. The comparison of specimens from uveitic glaucoma and primary open-angle glaucoma patients revealed no significant differences. CONCLUSIONS: The histological analysis of fibrotic blebs from the XEN and Preserflo implants did not show any pronounced immune or foreign-body reaction and revealed a similar histological pattern of failed blebs after trabeculectomy.


Subject(s)
Glaucoma Drainage Implants , Intraocular Pressure , Stents , Humans , Retrospective Studies , Male , Female , Aged , Middle Aged , Glaucoma Drainage Implants/adverse effects , Stents/adverse effects , Intraocular Pressure/physiology , Reoperation , Glaucoma/surgery , Glaucoma/diagnosis , Glaucoma/physiopathology , Fibrosis , Aged, 80 and over , Conjunctiva/pathology , Conjunctiva/surgery , Adult , Follow-Up Studies , Postoperative Complications/diagnosis , Filtering Surgery/adverse effects , Filtering Surgery/methods , Prosthesis Design , Blister/diagnosis , Blister/surgery , Blister/etiology
7.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 179-190, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37615697

ABSTRACT

PURPOSE   : To compare the efficacy and safety of the fixed-dose combination (FDC) of netarsudil 0.02%/latanoprost 0.005% ophthalmic solution (NET/LAT; Roclanda®) with bimatoprost 0.03%/timolol maleate 0.5% (BIM/TIM; Ganfort®) ophthalmic solution in the treatment of open-angle glaucoma (OAG) and ocular hypertension (OHT). METHODS: MERCURY-3 was a 6-month prospective, double-masked, randomized, multicenter, active-controlled, parallel-group, non-inferiority study. Patients (≥ 18 years) with a diagnosis of OAG or OHT in both eyes that was insufficiently controlled with topical medication (IOP ≥ 17 mmHg in ≥ 1 eye and < 28 mmHg in both eyes) were included. Following washout, patients were randomized to once-daily NET/LAT or BIM/TIM for up to 6 months; efficacy was assessed at Week 2, Week 4, and Month 3; safety was evaluated for 6 months. Comparison of NET/LAT relative to BIM/TIM for mean IOP at 08:00, 10:00, and 16:00 h was assessed at Week 2, Week 6, and Month 3. Non-inferiority of NET/LAT to BIM/TIM was defined as a difference of ≤ 1.5 mmHg at all nine time points through Month 3 and ≤ 1.0 mmHg at five or more of nine time points through Month 3. RESULTS: Overall, 430 patients were randomized (NET/LAT, n = 218; BIM/TIM, n = 212), and all received at least one dose of study medication. Efficacy analyses were performed at Month 3 on 388 patients (NET/LAT, n = 184; BIM/TIM, n = 204). NET/LAT demonstrated non-inferiority to BIM/TIM, with a between-treatment difference in IOP of ≤ 1.5 mmHg achieved at all time points and ≤ 1.0 mmHg at the majority of time points (six of nine) through Month 3. Mean diurnal IOP during the study ranged from 15.4 to 15.6 mmHg and 15.2 to 15.6 mmHg in the NET/LAT and BIM/TIM groups respectively, with no between-group statistically significant difference. No significant differences were observed in key secondary endpoints. No serious, treatment-related adverse events (AEs) were observed, and AEs were typically mild/moderate in severity. The most common treatment-related AEs were conjunctival hyperemia (NET/LAT, 30.7%; BIM/TIM, 9.0%) and cornea verticillata (NET/LAT, 11.0%; BIM/TIM, 0%). CONCLUSIONS: Once-daily NET/LAT was non-inferior to BIM/TIM in IOP reduction in OAG and OHT, with AEs consistent with previous findings. NET/LAT offers a compelling alternative FDC treatment option for OAG and OHT.


Subject(s)
Benzoates , Glaucoma, Open-Angle , Ocular Hypertension , beta-Alanine/analogs & derivatives , Humans , Glaucoma, Open-Angle/diagnosis , Glaucoma, Open-Angle/drug therapy , Timolol/adverse effects , Bimatoprost/therapeutic use , Latanoprost/adverse effects , Prospective Studies , Intraocular Pressure , Antihypertensive Agents/adverse effects , Tonometry, Ocular , Ocular Hypertension/diagnosis , Ocular Hypertension/drug therapy , Ophthalmic Solutions , Treatment Outcome , Double-Blind Method
8.
Graefes Arch Clin Exp Ophthalmol ; 262(1): 93-102, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37378878

ABSTRACT

PURPOSE: Mechanosensitive channels (MSCs) and primary cilium possess a possible relevance for the sensation of intraocular pressure (IOP). However, there is only limited data on their expression and localization in the ciliary body epithelium (CBE). The purpose of this study was to characterize the expression and localization of TRPP2 in a human non-pigmented ciliary epithelial cell (HNPCE) line. METHODS: The expression of the TRPP2 was studied by quantitative (q)RT-PCR and in situ hybridization in rat and human tissue. Protein expression and distribution were studied by western blot analysis, immunohistochemistry, and immunoelectron microscopy. Cellular location of TRPP2 was determined in rat and human CBE by immunofluorescence and immunoblot analysis. Electron microscopy studies were conducted to evaluate where and with substructure TRPP2 is localized in the HNPCE cell line. RESULTS: The expression of TRPP2 in rat and human non-pigmented ciliary epithelium was detected. TRPP2 was mainly located in nuclei, but also showed a punctate distribution pattern in the cytoplasm of HNPCE of the tissue and the cell line. In HNPCE cell culture, primary cilia did exhibit different length following serum starvation and hydrostatic pressure. TRPP2 was found to be colocalized with these cilia in HNPCE cells. CONCLUSION: The expression of TRPP2 and the primary cilium in the CB may indicate a possible role, such as the sensing of hydrostatic pressure, for the regulation of IOP. Functional studies via patch clamp or pharmacological intervention have yet to clarify the relevance for the physiological situation or aqueous humor regulation.


Subject(s)
Cilia , TRPP Cation Channels , Humans , Rats , Animals , Cilia/metabolism , TRPP Cation Channels/metabolism , Epithelial Cells/metabolism , Epithelium , Intraocular Pressure , Ciliary Body
9.
Clin Ophthalmol ; 17: 2243-2249, 2023.
Article in English | MEDLINE | ID: mdl-37564158

ABSTRACT

Purpose: The XEN gel stent was developed to reduce the risks of filtration surgery by standardizing the outflow of aqueous humor into the subconjunctival space. Recently, a modified version of the XEN63 gel stent was introduced. The goal of this study was to assess its efficacy and safety. Methods: This is a prospective, nonrandomized, observational, consecutive case series study at a single tertiary centre. Patients with open-angle glaucoma with above target intraocular pressure (IOP) despite maximal tolerated medication were included. The primary outcome was a change of median IOP. Secondary outcomes included a change in the number of medications, complete success, needling and complication rates. Success was defined as a lowering of IOP > 20% from baseline and IOP ≤ 14 mmHg. Complete success indicated that the target IOP was reached without medications. Results: Six patients were included. The median IOP decreased from 35.5 mmHg (25.0-40.0 mmHg) at baseline to 11.5 mmHg (4.0-15.0 mmHg, p = 0.03), and median IOP-lowering medication was reduced from 4.0 (3.0-4.0) at baseline to 0 (0-1.0, p = 0.03) after two years. Five patients (83.0%) had a complete success after two years. Two patients (33.0%) required a needling procedure. Three patients (50.0%) required an intervention due to symptomatic hypotony within the first three weeks postoperatively. Hypotony resolved completely or was asymptomatic after three months. Conclusion: Our study demonstrated a statistically significant reduction in both IOP and number of IOP-lowering medications. Complications were well manageable and had no long-term sequelae.

SELECTION OF CITATIONS
SEARCH DETAIL