Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Radiat Isot ; 134: 117-121, 2018 Apr.
Article in English | MEDLINE | ID: mdl-28648473

ABSTRACT

In order to automate sample preparation processes, a precision pattern dispenser was designed to reproducibly dispense radioactive solutions at pre-defined positions. It is composed of an automatic liquid sample handling unit coupled to an XYZ table. Qualification tests were conducted to evaluate the performance of the instrument and to assess the compliance with the requirements, in particular trueness (< 2%) and repeatability (< 1%). The instrument allows preparing sources in different source holders and on air filters, in a fast and accurate way.

2.
Appl Radiat Isot ; 114: 167-72, 2016 08.
Article in English | MEDLINE | ID: mdl-27236833

ABSTRACT

Two series of activity standards of (60)Co in cast steel matrix, developed for the calibration of gamma-ray spectrometry systems in the metallurgical sector, were characterised using a European interlaboratory comparison among twelve National Metrology Institutes and one international organisation. The first standard, consisting of 14 disc shaped samples, was cast from steel contaminated during production ("originally"), and the second, consisting of 15 similar discs, from artificially-contaminated ("spiked") steel. The reference activity concentrations of (60)Co in the cast steel standards were (1.077±0.019) Bqg(-1) on 1 January 2013 12h00 UT and (1.483±0.022) Bqg(-1) on 1 June 2013 12h00 UT, respectively.

3.
Appl Radiat Isot ; 109: 2-5, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26810874
4.
J Radioanal Nucl Chem ; 306(1): 325-331, 2015.
Article in English | MEDLINE | ID: mdl-26366031

ABSTRACT

An interlaboratory comparison was organised by JRC-IRMM among environmental radioactivity monitoring laboratories for the determination of gross alpha/beta activity concentration in drinking water. Independent standard methods were used for the reference value determination. The performance of participating laboratories was evaluated with respect to the reference values using relative deviations. Sample preparation and measurement methods used by the participating laboratories are detailed, in particular in the view of method-dependency of the results. Many of the participants' results deviate by more than two orders of magnitude from the reference values regardless of the techniques used. This suggests that gross methods need revision.

7.
Appl Radiat Isot ; 67(5): 918-21, 2009 May.
Article in English | MEDLINE | ID: mdl-19246206

ABSTRACT

The radioactivity of (180m)Ta has never been detected. The present attempt to detect it was carried out using a newly developed HPGe sandwich spectrometer installed 500m water equivalent underground in the HADES laboratory. The sample consisted of 6 discs of tantalum of natural isotopic composition with a total mass of 1500 g and a total mass for (180)Ta of 180 mg. The sample was measured for 68 days and the resulting lower bound for the half-life of (180m)Ta was 2.0 x 10(16)y, which is a factor of 2.8 higher than the previous highest value.


Subject(s)
Radioactivity , Spectrometry, Gamma/methods , Tantalum/analysis , Half-Life
SELECTION OF CITATIONS
SEARCH DETAIL
...