Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Eur Radiol ; 33(11): 7380-7387, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37284864

ABSTRACT

OBJECTIVE: For transjugular intrahepatic portosystemic shunt (TIPS) creation, ultrasound guidance for portal vein puncture is strongly recommended. However, outside regular hours of service, a skilled sonographer might be lacking. Hybrid intervention suites combine CT imaging with conventional angiography allowing to project 3D information into the conventional 2D imaging and further CT-fluoroscopic puncture of the portal vein. The purpose of this study was to assess whether TIPS using angio-CT facilitates the procedure for a single interventional radiologist. METHODS: All TIPS procedures from 2021 and 2022 which took place outside regular working hours were included (n = 20). Ten TIPS procedures were performed with just fluoroscopy guidance and ten procedures using angio-CT. For the angio-CT TIPS, a contrast-enhanced CT was performed on the angiography table. From the CT, a 3D volume was created using virtual rendering technique (VRT). The VRT was blended with the conventional angiography image onto the live monitor and used as guidance for the TIPS needle. Fluoroscopy time, area dose product, and interventional time were assessed. RESULTS: Hybrid intervention with angio-CT did lead to a significantly shorter fluoroscopy time and interventional time (p = 0.034 for both). Mean radiation exposure was significantly reduced, too (p = 0.04). Furthermore, the mortality rate was lower in patients who underwent the hybrid TIPS (0% vs 33%). CONCLUSION: TIPS procedure in angio-CT performed by only one interventional radiologist is quicker and reduces radiation exposure for the interventionalist compared to mere fluoroscopy guidance. The results further indicate increased safety using angio-CT. CLINICAL RELEVANCE STATEMENT: This study aimed to evaluate the feasibility of using angio-CT in TIPS procedures during non-standard working hours. Results indicated that the use of angio-CT significantly reduced fluoroscopy time, interventional time, and radiation exposure, while also leading to improved patient outcomes. KEY POINTS: • Image guiding such as ultrasound is recommended for transjugular intrahepatic portosystemic shunt creation but might be not available for emergency cases outside of regular working hours. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion is feasible for only one physician under emergency settings and results in lower radiation exposure and faster procedures. • Transjugular intrahepatic portosystemic shunt creation using an angio-CT with image fusion seems to be safer than using mere fluoroscopy guidance.


Subject(s)
Portasystemic Shunt, Transjugular Intrahepatic , Humans , Portasystemic Shunt, Transjugular Intrahepatic/methods , Portal Vein/diagnostic imaging , Portal Vein/surgery , Angiography , Ultrasonography , Tomography, X-Ray Computed , Treatment Outcome , Retrospective Studies
2.
CVIR Endovasc ; 6(1): 6, 2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36795179

ABSTRACT

BACKGROUND: Besides other factors, complication rate of transarterial interventions depends on the size of the vascular access. Therefore, the vascular access is mostly chosen as small as possible while still allowing all planned parts of the intervention. This retrospective analysis is to evaluate the safety and feasibility of sheathless arterial interventions for a broad spectrum of interventions in daily practice. METHODS: All sheathless interventions using a 4 F main catheter between May 2018 and September 2021 were included in the evaluation. Additionally, intervention parameters such as type of catheter, use of microcatheter and required change of main catheters were assessed. Information about the use about sheathless approach and catheters were obtained from the material registration system. All catheters were braided. RESULTS: 503 sheathless interventions with 4 F catheters from the groin were documented. The spectrum comprised bleeding embolization, diagnostic angiographies, arterial DOTA-TATE-therapy, uterine fibroid embolization, transarterial chemotherapy, transarterial radioembolization and others. In 31 cases (6 %) a change of the main catheter was required. In 381 cases (76 %) a microcatheter was utilized. No clinically relevant adverse events were observed (grade 2 or higher [CIRSE AE-classification]). None of the cases later required conversion to a sheath-based intervention. CONCLUSIONS: Sheathless interventions with a 4 F braided catheter from the groin are safe and feasible. It allows for a broad spectrum of interventions in daily practice.

3.
Acta Radiol ; 64(1): 119-124, 2023 Jan.
Article in English | MEDLINE | ID: mdl-34866428

ABSTRACT

BACKGROUND: Catheter-directed thrombolysis (CDT) is an effective and safe endovascular method used in critical limb ischemia and many other thromboembolic events. Ultrasound-assisted catheter-directed thrombolysis (US-CDT) is an emerging technique considered to accelerate thrombolysis and therefore is supposed to improve outcome. PURPOSE: To evaluate the efficacy of US-CDT in comparison to standard CDT in vitro. MATERIAL AND METHODS: A total of 69 sets of human venous blood were evaluated, each comprising a tube just treated with CDT, a tube treated with US-CDT, and a control tube. All tubes were kept under physiological conditions. Except for the controls, in all tubes 5 mg of tissue-type plasminogen activator was administered over the predetermined treatment interval. Thrombus mass was weighted at the end of the lysis intervals at 6 h or 24 h, respectively. RESULTS: CDT led to a mean thrombus reduction of 32% and ultrasound-assisted lysis led to a mean thrombus reduction of 41% (P < 0.001 for both). Thrombus reduction was significantly higher after US-CDT compared to CDT (P = 0.001). The better efficacy of US-CDT was mostly already apparent at early phases during thrombolysis and did further mildly increase over time (r = 0.24; P = 0.047). CONCLUSION: In vitro US-CDT is significantly superior to standard CDT; this effect is apparent at an early timepoint of lysis and slightly further increases over time.


Subject(s)
Fibrinolytic Agents , Thrombolytic Therapy , Humans , Fibrinolytic Agents/therapeutic use , Thrombolytic Therapy/methods , Treatment Outcome , Ultrasonography , Catheters , Retrospective Studies
4.
PLoS One ; 16(10): e0259127, 2021.
Article in English | MEDLINE | ID: mdl-34699565

ABSTRACT

INTRODUCTION: Port implantations at the forearm are associated with an increased risk of relevant vein thrombosis. Therefore, with this study we sought to identify the responsible risk factors to improve technical quality of the method. METHODS: This is a retrospective analysis of 313 patients with port implantation at the forearm in 2019. Then, exploratory statistics were conducted comprising Cox-Regression and Kaplan-Meier-Analyses. RESULTS: Mean age was 60 ± 14 years. 232 (74%) of the patients were female. No early infection was observed. 29 late infections and 57 cases of thrombosis occurred. In only 9% of the patients with thrombosis hospital admission was necessary for treatment. Median interval to the diagnosis of thrombosis was 23 days; inter-quartile-range: 16-75. Mean interval to elective port explantation was 227 ± 128 days. There was no effect of occurrence of thrombosis of the interventionalist, the assistance nor of several technical aspects. However, there was a significantly lower risk of thrombosis for primary implanted port system compared to replacement ports, Hazard-ratio: 0.34 [Confidence interval: 0.172, 0.674], p = 0.002. Age was a significant risk factor for late infections, Hazard-ratio: 3.35 [Confidence interval:1.84, 6.07], p < 0.0001. CONCLUSION: The main risk factor for adverse outcome after radiographically guided port implantation at the forearm is the type of the implanted port system. The reason for that might not be the material itself but the experience of a team with a certain port system. Age is a risk factor for late complications.


Subject(s)
Catheterization, Central Venous/adverse effects , Catheters, Indwelling/adverse effects , Forearm/blood supply , Venous Thrombosis/etiology , Aged , Catheterization, Central Venous/instrumentation , Female , Humans , Male , Middle Aged , Risk Assessment , Risk Factors
5.
Radiologe ; 61(1): 80-86, 2021 Jan.
Article in German | MEDLINE | ID: mdl-32816049

ABSTRACT

BACKGROUND: Transcatheter arterial chemoembolization (TACE) and biliary interventions are common procedures. OBJECTIVES: In this retrospective study, the radiation exposure of patients undergoing hepatic intervention will be analyzed and compared depending on the type and objective of the intervention. MATERIALS AND METHODS: This is an analysis of 7003 data sets of performed TACEs and biliary interventions from the DeGIR registry for the years 2016, 2017, and 2018. The dose area product (DAP), fluoroscopy time (FT), type of intervention, and anatomically defined target were recorded. RESULTS: Data with documented radiation doses were available for 4985 TACEs and for 2018 biliary interventions. For biliary interventions the median DAP was 2594 (interquartile range [IQR] = 1174-5858) cGycm2. For TACE, the median DAP was 11,632 [IQR = 5530-22,800] cGycm2 and significantly higher compared to biliary interventions (p < 0.0001). Biliary interventions with the highest DAP take place at the common hepatic duct; procedures with the longest FT were registered at the hepatic duct bifurcation. CONCLUSIONS: The individual radiation exposure during liver interventions is less dependent of the complexity of the procedure or the fluoroscopy time, but rather on the type of intervention and the anatomic target. The presented data can help to approximately estimate the radiation exposure in advance when planning an intervention.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Radiation Exposure , Fluoroscopy , Humans , Radiation Dosage , Registries , Retrospective Studies
6.
Radiol Med ; 124(9): 926-933, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31175536

ABSTRACT

PURPOSE: To evaluate the rate and types of complications after minimally invasive radiological central vein port implantation without ultrasound guidance. MATERIALS AND METHODS: We retrospectively evaluated 8654 patients who underwent port implantations in the subclavian vein without ultrasound guidance in our institution from 1998 to 2014 with regard to types and rates of peri-, early and late post-interventional complications according to the common classification for complications published by the Society of Interventional Radiology (SIR). Additionally, the impact of the training level of the operators on the rate of complications was analyzed. RESULTS: Successful port implantations were performed in 99.8% (8636/8654 procedures). From 1998 to 2014, a total of 565 (6.52%) complications were recorded. The overall percentage of the peri-, early and late post-interventional complications according to the SIR criteria was 1.69, 0.15 and 4.68, respectively. Significant differences due to the training level of the performing physician could be seen for the rates of pneumothorax, arterial puncture and hematoma. CONCLUSION: Minimally invasive radiological interventional port implantation is a safe treatment option with a low rate of complications even without ultrasound guidance.


Subject(s)
Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Catheters, Indwelling , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Radiology, Interventional , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures , Retrospective Studies , Subclavian Vein , Ultrasonography, Interventional , Young Adult
7.
Clin Hemorheol Microcirc ; 64(4): 887-898, 2016.
Article in English | MEDLINE | ID: mdl-27802211

ABSTRACT

OBJECTIVE: To evaluate various embolization particles on their physical properties with special regard on morphological variability and elasticity. METHODS: 8 embolization particles (EmboCept®, Contour SE® Microspheres, Embosphere® Micorspheres 400 µm, 500 µm, 1300 µm, Embozene® Microspheres, DC Beads®, Embozene Tandem®) were evaluated and graduated from 1-6 microscopically due to morphologic changes in vitro before, during and after their catheter passage by 4 blinded reviewers. To facilitate comparison, microscopic images were provided with a scale. RESULTS: All tested particles showed a homogenous shape and morphology before passage through the simulation catheter. During the passage all particles were elastically deformable, where necessary. After the catheter passage no loss of basic shape was seen. Changes in size were found in 5/8 particles. Grading of morphologic changes varied between mean value of 1.0 and 3.0. No complete destruction or loss of function was seen. CONCLUSION: All tested embolization particles are, regarding their morphological properties in sense of homogenous shape and deformation after catheter passage, a safe treatment option. Tested in vitro no less of functionality regarding physical properties should be expected.


Subject(s)
Catheterization/instrumentation , Embolization, Therapeutic/methods , Catheterization/methods , Humans , Particle Size
8.
Diagn Interv Radiol ; 21(5): 403-9, 2015.
Article in English | MEDLINE | ID: mdl-26268301

ABSTRACT

PURPOSE: Clinical cases of stent-fractures show that corrosion behavior might play a role in these fractures. Implanted in vivo, especially in combination with other implanted foreign materials, these metallic products are exposed to special conditions, which can cause a process of corrosion. Here, we aimed to test the corrosion potential of stents made of different materials in an in vitro setting. METHODS: A total of 28 peripheral stents of different materials (nitinol, cobalt-chromium-nickel, tantalum, V4A) and surface treatments (electropolish, mechanical polish, no polish) were tested in vitro. Corrosion was accelerated by applying a constant voltage of 3.5 V and amperage of 1.16 mA in 0.9% NaCl. RESULTS: Nitinol stents showed the lowest susceptibility to corrosion and the longest period without damage. The Memotherm II® (BARD Angiomed®) was the only stent that showed neither macroscopic nor microscopic damages. The worst performing material was cobalt-chromium-nickel, which showed corrosion damages about ten times earlier compared to nitinol. Considering the reasons for termination of the test, nitinol stents primarily showed length deficits, while V4A and tantalum stents showed fractures. Cobalt-chromium-nickel stents had multiple fractures or a complete lysis in equal proportions. When placed in direct contact, nitinol stents showed best corrosion resistance, regardless of what material they were combined with. In terms of polishing treatments, electropolished stents performed the best, mechanical-polished stents and those without polishing treatment followed. CONCLUSION: The analysis of corrosion behavior may be useful to select the right stent fulfilling the individual needs of the patient within a large number of different stents.


Subject(s)
Blood Vessel Prosthesis , Materials Testing/methods , Self Expandable Metallic Stents , Alloys/chemistry , Corrosion , In Vitro Techniques , Models, Biological , Surface Properties , Tantalum/chemistry
9.
Cardiovasc Intervent Radiol ; 34(3): 550-6, 2011 Jun.
Article in English | MEDLINE | ID: mdl-20512333

ABSTRACT

The purpose of this study was to determine whether rotational C-arm computed tomography (CT) allows visualization of liver metastases and adds relevant information for radioembolization (RE) treatment planning. Technetium angiography, together with C-arm CT, was performed in 47 patients to determine the feasibility for RE. C-arm CT images were compared with positron emission tomography (PET)/CT images for the detection of liver tumors. The images were also rated according one of the following three categories: (1) images that provide no additional information compared with DSA alone; (2) images that do provide additional information compared with DSA; and (2) images that had an impact on eligibility determination for and planning of the RE procedure. In all patients, 283 FDG-positive liver lesions were detected by PET. In venous contrast-phase CT, 221 (78.1%) and 15 (5.3%) of these lesions were either hypodense or hyperdense, respectively. In C-arm CT, 103 (36.4%) liver lesions were not detectable because they were outside of either the field of view or the contrast-enhanced liver segment. Another 25 (8.8%) and 98 (34.6%) of the liver lesions were either hyperdense or presented primarily as hypodense lesions with a rim enhancement, respectively. With PET/CT as the standard of reference, venous CT and C-arm CT failed to detect 47 (16.6%) and 57 (20.1%) of all liver lesions, respectively. For RE planning, C-arm CT provided no further information, provide some additional information, or had an impact on the procedure in 20 (42.5%), 15 (31.9%) and 12 (25.6%) of patients, respectively. We conclude that C-arm CT may add decisive information in patients scheduled for RE.


Subject(s)
Liver Neoplasms/diagnostic imaging , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Angiography, Digital Subtraction , Contrast Media , Embolization, Therapeutic , Feasibility Studies , Female , Humans , Iohexol/analogs & derivatives , Iopamidol/analogs & derivatives , Liver Neoplasms/secondary , Male , Microspheres , Middle Aged , Neoplasm Seeding , Radiography, Interventional , Radiopharmaceuticals , Technetium Tc 99m Aggregated Albumin , Yttrium Radioisotopes
10.
Vascular ; 17(3): 172-5, 2009.
Article in English | MEDLINE | ID: mdl-19476752

ABSTRACT

Acute hemoptysis might be caused by aneurysms of the subclavian artery. We report a 75-year-old female patient presenting with recurrent hemoptysis, dyspnea, fever, and episodes of unclear pneumonia. Further examination revealed a large intrathoracic aneurysm of the right subclavian artery. After an initial transfemoral interventional attempt to occlude the entry of the aneurysm, the patient developed persistent thoracic pain. The patient was then treated by a combined extrathoracic hybrid procedure with a left to right carotid-carotid-axillary artery bypass and an endovascular aneurysm exclusion by insertion of two iliac artery occluder stent grafts in the proximal brachiocephalic trunk and the distal right subclavian artery. After this combined intervention, hemoptysis disappeared, and the patient recovered remarkably during a follow-up of 24 months.


Subject(s)
Aneurysm/complications , Hemoptysis/etiology , Subclavian Artery , Aged , Aneurysm/diagnostic imaging , Aneurysm/surgery , Brachiocephalic Trunk/diagnostic imaging , Brachiocephalic Trunk/surgery , Carotid Arteries/diagnostic imaging , Carotid Arteries/surgery , Female , Hemoptysis/diagnostic imaging , Hemoptysis/surgery , Humans , Stents , Subclavian Artery/diagnostic imaging , Subclavian Artery/surgery , Tomography, X-Ray Computed , Treatment Outcome
11.
J Med Case Rep ; 2: 326, 2008 Oct 12.
Article in English | MEDLINE | ID: mdl-18847509

ABSTRACT

INTRODUCTION: Although diagnostic ureterorenoscopy is a minimally invasive and effective diagnostic procedure, it has the potential for significant postoperative complications. We report the first case in the literature of intrarenal arteriovenous fistulas causing hemodynamic effective anemia 4 days after ureterorenoscopic biopsy. CASE PRESENTATION: A 63-year-old Caucasian woman presented with hemodynamic effective macrohematuria (hemoglobin 70 g/liter) 4 days after ureterorenoscopy and biopsy of the upper pole collecting system due to recurrent microhematuria. Duplex-sonography and computed tomography angiography revealed multiple arteriovenous fistulas and erosions into the calyceal system. Intra-arterial digital subtraction angiography confirmed this condition. After superselective embolization of the arteriovenous fistulas, the patient had no further episodes of bleeding or microhematuria. CONCLUSION: If malignancies, urolithiasis or urinary tract infections are ruled out by common diagnostic procedures as the cause of recurrent minor or gross hematuria, the possibility of arteriovenous fistulas should be included in the differential diagnosis and Duplex-Sonography or the more invasive selective renal arteriography should be performed as this is the most definitive method for diagnosing arteriovenous fistula.

12.
Digestion ; 78(1): 34-8, 2008.
Article in English | MEDLINE | ID: mdl-18797167

ABSTRACT

BACKGROUND/AIMS: Pravastatin, a 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitor, has been shown to inhibit growth and to induce apoptosis in human hepatocellular carcinoma (HCC) cells. However, the potential benefit of pravastatin in HCC patients has still not been characterized, which prompted us to test the efficacy of pravastatin in patients with advanced HCC. METHODS: We investigated prospectively a cohort of 183 HCC patients who had been selected for palliative treatment by transarterial chemoembolization (TACE). Fifty-two patients received TACE combined with pravastatin (20-40 mg/day) and 131 patients received chemoembolization alone. Six independent predictors of survival according to the Vienna survival model for HCC were equally distributed in both groups. RESULTS: During the observation period of up to 5 years, 31 (23.7%) out of 131 patients treated by TACE alone and 19 (36.5%) out of 52 patients treated by TACE and pravastatin survived. Median survival was significantly longer in HCC patients treated by TACE and pravastatin (20.9 months, 95% CI 15.5-26.3, p = 0.003) than in HCC patients treated by TACE alone (12.0 months, 95% CI 10.3-13.7). CONCLUSION: Combined treatment of chemoembolization and pravastatin improves survival of patients with advanced HCC in comparison to patients receiving chemoembolization alone.


Subject(s)
Carcinoma, Hepatocellular/therapy , Chemoembolization, Therapeutic , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Liver Neoplasms/therapy , Pravastatin/therapeutic use , Aged , Antibiotics, Antineoplastic/administration & dosage , Carcinoma, Hepatocellular/mortality , Combined Modality Therapy , Epirubicin/administration & dosage , Female , Germany/epidemiology , Humans , Kaplan-Meier Estimate , Liver Neoplasms/mortality , Male , Middle Aged , Prospective Studies
13.
Digestion ; 75(2-3): 104-12, 2007.
Article in English | MEDLINE | ID: mdl-17598962

ABSTRACT

BACKGROUND/AIMS: To evaluate the long-term outcome of surgical and non-surgical local treatments of patients with hepatocellular carcinoma (HCC). METHODS: We stratified a cohort of 278 HCC patients using six independent predictors of survival according to the Vienna survival model for HCC (VISUM-HCC). RESULTS: Prior to therapy, 224 HCC patients presented with VISUM stage 1 (median survival 18 months) while 29 patients were classified as VISUM stage 2 (median survival 4 months) and 25 patients as VISUM stage 3 (median survival 3 months). A highly significant (p < 0.001) improved survival time was observed in VISUM stage 1 patients treated with liver resection (n = 52; median survival 37 months) or chemoembolization (TACE) and subsequent radiofrequency ablation (RFA) (n = 44; median survival 45 months) as compared to patients receiving chemoembolization alone (n = 107; median survival 13 months) or patients treated by tamoxifen only (n = 21; median survival 6 months). Chemoembolization alone significantly (p < or = 0.004) improved survival time in VISUM stage 1-2 patients but not (p = 0.341) in VISUM stage 3 patients in comparison to those treated by tamoxifen. CONCLUSION: Both liver resection or combined chemoembolization and RFA improve markedly the survival of patients with HCC.


Subject(s)
Carcinoma, Hepatocellular/therapy , Catheter Ablation , Chemoembolization, Therapeutic , Liver Neoplasms/therapy , Aged , Chi-Square Distribution , Combined Modality Therapy , Female , Hepatectomy , Humans , Liver Function Tests , Male , Middle Aged , Neoplasm Staging , Radiography, Interventional , Retrospective Studies , Statistics, Nonparametric , Survival Rate , Tomography, X-Ray Computed , Treatment Outcome
14.
Ann Vasc Surg ; 20(4): 525-8, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16732443

ABSTRACT

An aortocaval fistula is a severe complication of an aortoiliac aneurysm, usually associated with high perioperative morbidity and mortality during open operative repair. We describe the successful endovascular treatment of a symptomatic infrarenal aortic aneurysm ruptured into the inferior vena cava with secondary interventional coiling of a persistent type II endoleak because of retrograde perfusion of the inferior mesenteric artery. Endovascular exclusion of ruptured abdominal aneurysms seems to be a valuable treatment option for selected patients even with complicated vascular conditions like an aortocaval fistula.


Subject(s)
Angioplasty, Balloon , Aortic Aneurysm, Abdominal/therapy , Aortic Diseases/therapy , Aortic Rupture/therapy , Arteriovenous Fistula/therapy , Blood Vessel Prosthesis Implantation , Iliac Aneurysm/therapy , Stents , Vena Cava, Inferior , Acute Disease , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Diseases/diagnostic imaging , Aortic Rupture/diagnostic imaging , Aortography , Arteriovenous Fistula/diagnostic imaging , Combined Modality Therapy , Embolization, Therapeutic , Humans , Male , Mesenteric Artery, Inferior/diagnostic imaging , Middle Aged , Recurrence , Retreatment , Tomography, X-Ray Computed , Vena Cava, Inferior/diagnostic imaging
15.
Radiology ; 235(2): 687-98, 2005 May.
Article in English | MEDLINE | ID: mdl-15770035

ABSTRACT

PURPOSE: To retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography, performed with an integrated parallel acquisition technique for high isotropic spatial resolution, with selective digital subtraction angiography (DSA) and intravascular ultrasonography (US) for accuracy of diameter and area measurements in renal artery stenosis. MATERIALS AND METHODS: The study was approved by the institutional review board, and consent was obtained from all patients. Forty-five patients (17 women, 28 men; mean age, 62.2 years) were evaluated for suspected renal artery stenosis. Three-dimensional gadolinium-enhanced MR angiograms were acquired with isotropic spatial resolution of 0.8 x 0.8 x 0.9 mm in 23-second breath-hold with an integrated parallel acquisition technique. In-plane diameter of stenosis was measured along vessel axis, and perpendicular diameter and area of stenosis were assessed in cross sections orthogonal to vessel axis, on multiplanar reformations. Interobserver agreement between two radiologists in measurements of in-plane and perpendicular diameters of stenosis and perpendicular area of stenosis was assessed with mean percentage of difference. In a subset of patients, degree of stenosis at MR angiography was compared with that at DSA (n = 20) and intravascular US (n = 11) by using Bland-Altman plots and correlation analyses. RESULTS: Mean percentage of difference in stenosis measurement was reduced from 39.3% +/- 78.4 (standard deviation) with use of in-plane views to 12.6% +/- 9.5 with use of cross-sectional views (P < .05). Interobserver agreement for stenosis grading based on perpendicular area of stenosis was significantly better than that for stenosis grading based on in-plane diameter of stenosis (mean percentage of difference, 15.2% +/- 24.2 vs 54.9% +/- 186.9; P < .001). Measurements of perpendicular area of stenosis on MR angiograms correlated well with those on intravascular US images (r(2) = 0.90). CONCLUSION: Evaluation of cross-sectional images reconstructed from high-spatial-resolution three-dimensional gadolinium-enhanced MR renal angiographic data increases the accuracy of the technique and decreases interobserver variability.


Subject(s)
Angiography, Digital Subtraction , Endosonography , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Renal Artery Obstruction/diagnosis , Adult , Aged , Aged, 80 and over , Algorithms , Angioplasty, Balloon/statistics & numerical data , Artifacts , Contrast Media , Data Interpretation, Statistical , Female , Gadolinium , Humans , Male , Middle Aged , Nephrectomy/statistics & numerical data , Observer Variation , Renal Artery Obstruction/therapy , Sensitivity and Specificity , Statistics as Topic , Stents/statistics & numerical data
17.
Digestion ; 66(2): 127-30, 2002.
Article in English | MEDLINE | ID: mdl-12428073

ABSTRACT

BACKGROUND: We have recently shown that the transjugular intrahepatic portosystemic shunt (TIPS) is more effective than paracentesis in the treatment of cirrhotic patients with severe ascites and can prolong survival in selected patients. Although an improved quality of life (QOL) has been suggested in these patients after the TIPS procedure, so far there are no data available to substantiate this assumption. Therefore, the aim of this study was to determine the effect of TIPS on the QOL in cirrhotic patients with refractory or recidivant ascites. METHODS: 21 cirrhotic patients who underwent TIPS for refractory or recidivant ascites were investigated. All patients were pretreated with repeated paracentesis for at least 1 year. Before the procedure and at 3 and 6 months during follow-up, the patients themselves rated QOL, fatigue and physical performance on a visual analogue scale (range 0-100). Furthermore, QOL was determined by the QOL index (range 0-10) according to Spitzer. RESULTS: Patients' rating of the QOL on the visual analogue scale significantly increased from 35 +/- 25 (baseline) to 64 +/- 28 (3 months), and 66 +/- 24 (6 months; p = 0.02). Similarly, the QOL index significantly increased from 6.9 +/- 2.0 (baseline) to 8.3 +/- 2.1 (3 months), and 8.6 +/- 1.7 (6 months; p < 0.001). The increase of QOL was more pronounced in patients with complete response to TIPS. CONCLUSIONS: We demonstrate that TIPS for refractory or recidivant ascites improves the QOL in patients with cirrhosis. Our data indicates that this improvement is dependent on the response to therapy.


Subject(s)
Ascites/therapy , Liver Cirrhosis/therapy , Portasystemic Shunt, Transjugular Intrahepatic , Quality of Life , Ascites/etiology , Female , Humans , Liver Cirrhosis/complications , Male , Middle Aged , Recurrence , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...