Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
Animals (Basel) ; 12(18)2022 Sep 16.
Article in English | MEDLINE | ID: mdl-36139317

ABSTRACT

Mechanical overburdening is a major risk factor that provokes non-infectious claw diseases. Moreover, lameness-causing lesions often remain undetected and untreated. Therefore, prevention of claw tissue overburdening is of interest, especially by analyzing harmful effects within dairy cows' housing environment. However, objective "on-cow" methods for bovine gait analysis are underdeveloped. The purpose of the study was to apply an innovative mobile pressure sensor system attached at the claws to perform pedobarometric gait analysis. A further goal was the supplementation with accelerative data, generated simultaneously by use of two inertial measurement units (IMUs), attached at metatarsal level. IMU data were analyzed with an automatic step detection algorithm. Gait analysis was performed in ten dairy cows, walking and trotting on concrete flooring and rubber mats. In addition to the basic applicability of the sensor systems and with the aid of the automatic step detection algorithm for gait analysis in cows, we were able to determine the impact of the gait and flooring type on kinematic and kinetic parameters. For pressure sensor output, concrete was associated with significantly (p < 0.001) higher maximum and average pressure values and a significantly smaller contact area, compared to rubber mats. In contrast to walking, trotting led to a significantly higher force, especially under the medial claw. Further, IMU-derived parameters were significantly influenced by the gait. The described sensor systems are useful tools for detailed gait analysis in dairy cows. They allow the investigation of factors which may affect claw health negatively.

2.
J Exp Biol ; 225(12)2022 06 15.
Article in English | MEDLINE | ID: mdl-35554550

ABSTRACT

Therian mammals are known to move their forelimbs in a parasagittal plane, retracting the mobilised scapula during stance phase. Non-cursorial therian mammals often abduct the elbow out of the shoulder-hip parasagittal plane. This is especially prominent in Tamandua (Xenarthra), which suggests they employ aspects of sprawling (e.g. lizard-like) locomotion. Here, we tested whether tamanduas use sprawling forelimb kinematics, i.e. a largely immobile scapula with pronounced lateral spine bending and long-axis rotation of the humerus. We analysed high-speed videos and used X-ray motion analysis of tamanduas walking and balancing on branches of varying inclinations and provide a quantitative characterization of gaits and forelimb kinematics. Tamanduas displayed lateral sequence/lateral couplets on flat ground and horizontal branches, but increased diagonality on steeper inclines and declines, resulting in lateral sequence/diagonal couplets gaits. This result provides further evidence for high diagonality in arboreal species, probably maximising stability in arboreal environments. Further, the results reveal a mosaic of sprawling and parasagittal kinematic characteristics. The abducted elbow results from a constantly internally rotated scapula about its long axis and a retracted humerus. Scapula retraction contributes considerably to stride length. However, lateral rotation in the pectoral region of the spine (range: 21 deg) is higher than reported for other therian mammals. Instead, it is similar to that of skinks and alligators, indicating an aspect generally associated with sprawling locomotion is characteristic for forelimb kinematics of tamanduas. Our study contributes to a growing body of evidence of highly variable non-cursorial therian mammal locomotor kinematics.


Subject(s)
Lizards , Vermilingua , Animals , Biomechanical Phenomena , Forelimb , Gait , Locomotion , Mammals , X-Rays
3.
Vet Sci ; 8(6)2021 May 27.
Article in English | MEDLINE | ID: mdl-34072030

ABSTRACT

The superficial digital flexor tendon (SDFT) is the most frequently injured structure of the musculoskeletal system in sport horses and a common cause for early retirement. This project's aim was to visualize and measure the strain of the sound, injured, and healing SDFTs in a pony during walk and trot. For this purpose, biplanar high-speed fluoroscopic kinematography (FluoKin), as a high precision X-ray movement analysis tool, was used for the first time in vivo with equine tendons. The strain in the metacarpal region of the sound SDFT was 2.86% during walk and 6.78% during trot. When injured, the strain increased to 3.38% during walk and decreased to 5.96% during trot. The baseline strain in the mid-metacarpal region was 3.13% during walk and 6.06% during trot and, when injured, decreased to 2.98% and increased to 7.61%, respectively. Following tendon injury, the mid-metacarpal region contributed less to the overall strain during walk but showed increased contribution during trot. Using this marker-based FluoKin technique, direct, high-precision, and long-term strain measurements in the same individual are possible. We conclude that FluoKin is a powerful tool for gaining deeper insight into equine tendon biomechanics.

4.
BMC Vet Res ; 17(1): 223, 2021 Jun 25.
Article in English | MEDLINE | ID: mdl-34172051

ABSTRACT

BACKGROUND: Long-term cyclic tensile testing with equine palmar/plantar tendons have not yet been performed due to problems in fixing equine tendons securely and loading them cyclically. It is well established that the biomechanical response of tendons varies during cyclic loading over time. The aim of this study was to develop a clamping device that enables repetitive cyclic tensile testing of equine superficial digital flexor tendon for at least 60 loading cycles and for 5 min. RESULTS: A novel cryo-clamp was developed and built. Healthy and collagenase-treated pony SDFTs were mounted in the custom-made cryo-clamp for the proximal tendon end and a special clamping device for the short pastern bone (os coronale). Simultaneously with tensile testing, we used a biplanar high-speed fluoroscopy system (FluoKin) to track tendon movement. The FluoKin system was additionally validated in precision measurements. During the cyclic tensile tests of the SDFTs, the average maximal force measured was 325 N and 953 N for a length variation of 2 and 4 % respectively. The resulting stress averaged 16 MPa and 48 MPa respectively, while the modulus of elasticity was 828 MPa and 1212 MPa respectively. Length variation of the metacarpal region was, on average, 4.87 % higher after incubation with collagenase. The precision of the FluoKin tracking was 0.0377 mm, defined as the standard deviation of pairwise intermarker distances embedded in rigid bodies. The systems accuracy was 0.0287 mm, which is the difference between the machined and mean measured distance. CONCLUSION: In this study, a good performing clamping technique for equine tendons under repetitive cyclic loading conditions is described. The presented cryo-clamps were tested up to 50 min duration and up to the machine maximal capacity of 10 kN. With the possibility of repetitive loading a stabilization of the time-force-curve and changes of hysteresis and creep became obvious after a dozen cycles, which underlines the necessity of repetitive cyclical testing. Furthermore, biplanar high-speed fluoroscopy seems an appropriate and highly precise measurement tool for analysis of tendon behaviour under repetitive load in equine SDFTs.


Subject(s)
Horses/physiology , Stress, Mechanical , Tendons/physiology , Animals , Biomechanical Phenomena/physiology , Fluoroscopy/veterinary , Forelimb/physiology
SELECTION OF CITATIONS
SEARCH DETAIL