1.
Lab Chip ; 19(15): 2581-2588, 2019 08 07.
Article in English | MEDLINE | ID: mdl-31250849

ABSTRACT

High-throughput fluorescence polarization immunoassays (FPIAs) for mycotoxin were conducted using a portable FP analyzer with a microdevice. Simultaneous FPIA measurements for 8 different deoxynivalenol (DON) concentrations in 12 chambers (total of 96 samples) and high-throughput FPIA measurements for single DON concentrations in more than 500 chambers were conducted. The results indicated that simultaneous FPIAs for 96 independent samples and for 500 samples were possible by FP imaging. The FP analyzer has a size of 65 cm (W 35 cm × D 15 cm × H 15 cm) and costs less than $5000. The sample volume was 1 nL. Furthermore, it is expected that sample reaction and FP detection can be automatically conducted with the analyzer by changing the microdevice and the software. Its features such as low cost and portability will contribute to on-site measurement and point-of-care testing. Additionally, the high-throughput feature will contribute to the study of molecular interactions based on FP measurements.

2.
Rev Sci Instrum ; 89(2): 024103, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29495833

ABSTRACT

Fluorescence polarization (FP) offers easy operation and rapid processing, making it implementable in molecular interaction analysis. Previously we have developed a unique FP measurement system using a liquid crystal (LC) layer and an image sensor. The system is based on a principle of synchronized detection between the switching rate of the LC layer and the sampling rate of the CCD. The FP system realized simultaneous multiple sample detection; however, the measurement precision was lower than that of the conventional FP apparatus. The main drawbacks were low light transmittance of the LC layer and insufficient synchronization between the LC layer and CCD. In this paper, we developed a new FP analyzer based on LC-CCD synchronization detection. By using a newly designed LC with high transmittance and improving synchronization, the performance of the system has been dramatically improved. Additionally, we reduced the cost by using an inexpensive CCD and an LED as the excitation source. Simultaneous FP immunoassay of multiple samples of prostaglandin E2 was performed. The error rate of the FP system is reduced from 16.9% to 3.9%, as comparable to the commercial conventional FP system.

3.
Anal Chem ; 87(19): 9647-52, 2015 Oct 06.
Article in English | MEDLINE | ID: mdl-26352939

ABSTRACT

The detection system which enables simultaneous fluorescence polarization (FP) measurement of multiple samples was proposed and proven by a proof-of-concept experiment on the viscosity dependence of FP of fluorescein sample in water-ethylene glycol solution and another experiment on the FP immunoassay of prostaglandin E2 sample. The measurement principle of FP is based on the synchronization between the orientation of the liquid crystal molecules and the sampling frequency of a CCD. This report is the first description of the simultaneous FP measurement of multiple samples. This system has a great potential for equipment miniaturization and price reduction as well as providing simultaneous FP measurement of multiple samples.


Subject(s)
Fluorescence Polarization/instrumentation , Liquid Crystals/chemistry , Dinoprostone/analysis , Fluorescein/analysis