Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Natl J Maxillofac Surg ; 14(2): 242-248, 2023.
Article in English | MEDLINE | ID: mdl-37661993

ABSTRACT

Purpose: To compare the clinical outcome of tapered and cylindrical implants placed in the posterior region of mandible by measuring implant stability and crestal bone level at the healing period. Materials and Methods: A prospective clinical study was conducted on 15 patients who were included in the study based on the inclusion and exclusion criteria. A total of 30 dental implants were placed in both groups: 15 implants in Group I (tapered implants) and 15 implants in Group II (cylindrical implants) in the posterior region of mandible. Implant stability assessment by periotest was done at the time of implant placement (baseline) and after 3 months. The crestal bone level was measured with the help of radiovisiography (RVG) at the time of implant placement (baseline) and at 3 and 6 months. Results: At baseline, there was statistically significant (P < 0.01) difference in primary implant stability. Tapered implants had higher primary implant stability than cylindrical implants. However, at 3 months, there was no statistically significant (P > 0.05) difference in the secondary implant stability of both the groups. Also, the crestal bone level on the mesial and distal sides of dental implant for tapered and cylindrical implants was statistically nonsignificant (P > 0.05) at all time intervals, that is, at baseline and at 3 and 6 months. Conclusion: Tapered implants had higher primary stability than cylindrical implants, and no difference was found in secondary stability. The crestal bone level was similar for both groups during early healing and early post-loading periods.

2.
Natl J Maxillofac Surg ; 11(2): 199-206, 2020.
Article in English | MEDLINE | ID: mdl-33897181

ABSTRACT

INTRODUCTION: Vitamin D has been shown to play a vital role in bone mineral homeostasis by stimulating the intestinal absorption of calcium and phosphate. The critical role of Vitamin D in bone metabolism triggered the need to evaluate the effect of Vitamin D deficiency and hence replacement of the same on osseointegration of dental implants. This prospective study evaluated the crestal bone level in patients having low level of Vitamin D treated with dental implant with or without Vitamin D3 supplements. MATERIALS AND METHODS: A prospective clinical study was conducted on 32 patients based on the inclusion and exclusion criteria. Patients were divided into two groups on the basis of Vitamin D level < 30 ng/ml (Group I: patients receiving Vitamin D3 supplements, i.e., cholecalciferol 1 g sachet 60,000 IU/month) or <30 ng/ml (Group II: not receiving Vitamin D3 supplements). The crestal bone level measurements were made with the help of Digimizer Image Analysis, MedCalc software. RESULTS: All implants showed clinically acceptable crestal bone level at interval of 1 week (baseline), 3 months, and 6 months. There was a statistically nonsignificant difference seen for the values between the groups (P > 0.05) for all other values at various time intervals. However, there was a statistically significant/highly significant difference seen for the values between the groups (P < 0.01, 0.05) for 3 months distal with higher values for Group I as compared to Group II. CONCLUSION: From the study, it can be concluded that cholecalciferol has systemic effects on accelerating bone formation around titanium implant.

SELECTION OF CITATIONS
SEARCH DETAIL