1.
Front Vet Sci ; 11: 1202931, 2024.
Article in English | MEDLINE | ID: mdl-38545561

ABSTRACT

The applicability of electrical impedance tomography (EIT) in birds is unknown. This study aimed to evaluate the use of EIT in anaesthetised chickens in four recumbency positions. Four adult Hyline chickens were anaesthetised with isoflurane in oxygen, and intubated endotracheally for computed tomography (CT). A rubber belt was placed around the coelom caudal to the shoulder joint. A chicken-specific finite element (FE) model, which is essential to generate anatomically accurate functional EIT images for analysis, was constructed based on the CT images obtained at the belt level. Ten additional chickens were anaesthetised with the same protocol. An EIT electrode belt was placed at the same location. The chickens were breathing spontaneously and positioned in dorsal, ventral, right and left lateral recumbency in a randomised order. For each recumbency, raw EIT data were collected over 2 min after 13 min of stabilisation. The data were reconstructed into functional EIT images. EIT variables including tidal impedance variation (TIV), centre of ventilation right to left (CoVRL) and ventral to dorsal (CoVVD), right to left (RL) ratio, impedance change (ΔZ) and eight regional impedance changes including the dorsal, central-dorsal, central-ventral and ventral regions of the right and left regions were analysed. Four breathing patterns (BrP) were observed and categorised based on the expiratory curve. A linear mixed model was used to compare EIT variables between recumbencies. Fisher's exact test was used to compare the frequencies of breathing patterns for each recumbency. The ΔZ observed was synchronous to ventilation, and represented tidal volume of the cranial air sacs as confirmed by CT. Significant differences were found in CoVVD and regional impedance changes between dorsal and ventral recumbencies (P < 0.05), and in CoVRL, RL ratio and regional impedance changes between right and left recumbencies (P < 0.05), which suggested a tendency for the distribution of ventilation to shift towards non-dependent air sacs. No differences were found for TIV and respiratory rate between recumbencies. Recumbency had a significant effect on the frequencies of each of the four BrPs (P = 0.001). EIT can monitor the magnitude and distribution of ventilation of the cranial air sacs in different recumbencies in anaesthetised chickens.

2.
Pediatr Res ; 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38273117

ABSTRACT

BACKGROUND: Physiological changes during the insertion of a rescue nasopharyngeal tube (NPT) after birth are unclear. METHODS: Observational study of very preterm infants in the delivery room. Data were extracted at predefined timepoints starting with first facemask placement after birth until 5 min after insertion of NPT. End-expiratory lung impedance (EELI), heart rate (HR) and SpO2/FiO2-ratio were analysed over time. Changes during the same time span of NIPPV via facemask and NIPPV via NPT were compared. RESULTS: Overall, 1154 inflations in 15 infants were analysed. After NPT insertion, EELI increased significantly [0.33 AU/kg (0.19-0.57), p < 0.001]. Compared with the mask period, changes in EELI were not significantly larger during the NPT period [median difference (IQR) = 0.14 AU/kg (-0.14-0.53); p = 0.12]. Insertion of the NPT was associated with significant improvement in HR [52 (33-96); p = 0.001] and SpO2/FiO2-ratio [161 (69-169); p < 0.001] not observed during the mask period. CONCLUSIONS: In very preterm infants non-responsive to initial facemask ventilation after birth, insertion of an NPT resulted in a considerable increase in EELI. This additional gain in lung volume was associated with an immediate improvement in clinical parameters. The use of a NPT may prevent intubation in selected non-responsive infants. IMPACT: After birth, a nasopharyngeal tube may be considered as a rescue airway in newborn infants non-responsive to initial positive pressure ventilation via facemask. Although it is widely used among clinicians, its effect on lung volumes and physiological parameters remains unclear. Insertion of a rescue NPT resulted in a considerable increase in lung volume but this was not significantly larger than during facemask ventilation. However, insertion of a rescue NPT was associated with a significant and clinically important improvement in heart rate and oxygenation. This study highlights the importance of individual strategies in preterm resuscitation and introduces the NPT as a valid option.

3.
Pediatr Pulmonol ; 59(2): 323-330, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37937894

ABSTRACT

OBJECTIVES: To assess the clinical efficacy, safety, and potential physiological mechanisms of highflow therapy with superimposed high frequency oscillations ("osciflow"). STUDY DESIGN: In this prospective, randomized, single center crossover trial, 30 preterm infants were randomized to receive osciflow or highflow therapy first, each for 180 min. During osciflow, an oscillatory amplitude of 20 mbar and a frequency of 6 Hz were set. The flow rate was 4 L/min during both interventions. Primary outcome was the paired difference in the combined number of desaturations (SpO2 < 80%) and bradycardia (heart rate <80 beats per min) between interventions. Safety outcomes included nasal trauma, pneumothorax and treatment failure, and a pain score was assessed. In 20 infants, electrical impedance tomography (EIT) recordings were performed to evaluate oscillatory (VOsc ) and tidal volumes (VT ) at the lung level. RESULTS: Infants with a mean (SD) postnatal age of 33.1 ± 1.2 weeks were included. The median (IQR) number of episodes of desaturation and bradycardia was 19.5 (6-49) during osciflow and 26 (6-44) during highflow therapy (paired difference -2; IQR -10 to 9; p = .37). There were no differences in safety outcomes and pain scores. During osciflow, EIT recordings showed a signal at 6 Hz, which was not detectable during highflow. Corresponding mean (SD) VOsc /VT ratio was 9% (±5%). CONCLUSIONS: In preterm infants, osciflow did not reduce the number of desaturations and bradycardia compared with highflow therapy. Although VOsc were transmitted to the lung during osciflow, their magnitude was small. Osciflow was safe and well tolerated.


Subject(s)
Bradycardia , Infant, Premature , Infant , Infant, Newborn , Humans , Bradycardia/therapy , Cross-Over Studies , Prospective Studies , Pain/etiology
4.
Sci Rep ; 13(1): 20842, 2023 11 27.
Article in English | MEDLINE | ID: mdl-38012186

ABSTRACT

Endotracheal suctioning is a widely used procedure to remove secretions from the airways of ventilated patients. Despite its prevalence, regional effects of this maneuver have seldom been studied. In this study, we explore its effects on regional lung aeration in neonates and young infants using electrical impedance tomography (EIT) as part of the large EU-funded multicenter observational study CRADL. 200 neonates and young infants in intensive care units were monitored with EIT for up to 72 h. EIT parameters were calculated to detect changes in ventilation distribution, ventilation inhomogeneity and ventilation quantity on a breath-by-breath level 5-10 min before and after suctioning. The intratidal change in aeration over time was investigated by means of regional expiratory time constants calculated from all respiratory cycles using an innovative procedure and visualized by 2D maps of the thoracic cross-section. 344 tracheal suctioning events from 51 patients could be analyzed. They showed no or very small changes of EIT parameters, with a dorsal shift of the center of ventilation by 0.5% of the chest diameter and a 7% decrease of tidal impedance variation after suctioning. Regional time constants did not change significantly. Routine suctioning led to EIT-detectable but merely small changes of the ventilation distribution in this study population. While still a measure requiring further study, the time constant maps may help clinicians interpret ventilation mechanics in specific cases.


Subject(s)
Critical Illness , Tomography , Infant, Newborn , Humans , Infant , Electric Impedance , Suction , Tomography/methods , Lung/diagnostic imaging
5.
SAGE Open Med ; 11: 20503121231182517, 2023.
Article in English | MEDLINE | ID: mdl-37576564

ABSTRACT

Objectives: Avoiding inadvertent hypothermia during surgery is important. Intravenous fluid warmers used intraoperatively are critical for maintaining euthermia. We sought to prospectively evaluate the performance of the parylene-coated enFlow™ intravenous fluid warmer in patients undergoing surgery. Methods: This was a prospective two-center observational clinical trial performed in inpatient surgical services of two large academic hospital systems. After written informed consent, patients were enrolled in the trial. All patients were adults scheduled for a surgery that was expected to last for at least 1 h with the administration of at least 1 L of fluid warmed prior to infusion. Patient temperature was recorded in the preoperative unit, at the induction of anesthesia, and then every 15 or 30 min until the end of surgery. Temperature monitoring continued in the recovery unit. The parylene-coated enFlow™ intravenous fluid warmer was used in addition to the usual patient warming techniques. The primary outcome was the average core temperature, and secondary analyses assessed individual temperature measurements, temperature measurements during specific time periods, and rate of hypothermic events. Results: In all, 50 patients (29 males) with a mean age of 64 years were included in the analysis. The mean surgical time was 195 min and patients received an average of 1142 mL of fluids. Core temperature dropped by only 0.3°C approximately 60 min after induction and recovered back to the baseline level approximately 60 min later. There was no correlation between flow rate and measured core body temperature. Conclusions: The parylene-coated enFlow intravenous fluid warmer was able to warm fluids at all flow rates during prolonged surgery. The results showed that enFlow performed as expected.

6.
Front Pediatr ; 11: 1167077, 2023.
Article in English | MEDLINE | ID: mdl-37292377

ABSTRACT

Introduction: Electrical impedance tomography (EIT) allows assessment of ventilation and aeration homogeneity which may be associated with respiratory outcomes in preterm infants. Methods: This was a secondary analysis to a recent randomized controlled trial in very preterm infants in the delivery room (DR). The predictive value of various EIT parameters assessed 30 min after birth on important respiratory outcomes (early intubation <24 h after birth, oxygen dependency at 28 days after birth, and moderate/severe bronchopulmonary dysplasia; BPD) was assessed. Results: Thirty-two infants were analyzed. A lower percentage of aerated lung volume [OR (95% CI) = 0.8 (0.66-0.98), p = 0.027] as well as a higher aeration homogeneity ratio (i.e., more aeration in the non-gravity-dependent lung) predicted the need for supplemental oxygen at 28 days after birth [9.58 (5.16-17.78), p = 0.0028]. Both variables together had a similar predictive value to a model using known clinical contributors. There was no association with intubation or BPD, where numbers were small. Discussion: In very preterm infants, EIT markers of aeration at 30 min after birth accurately predicted the need for supplemental oxygen at 28 days after birth but not BPD. EIT-guided individualized optimization of respiratory support in the DR may be possible.

7.
Arch Dis Child Fetal Neonatal Ed ; 108(3): 217-223, 2023 May.
Article in English | MEDLINE | ID: mdl-36424125

ABSTRACT

OBJECTIVE: The effect of prophylactic surfactant nebulisation (SN) is unclear. We aimed to determine whether prophylactic SN improves early lung aeration. DESIGN: Parallel, randomised clinical trial, conducted between March 2021 and January 2022. SETTING: Delivery room (DR) of a tertiary neonatal centre in Zurich, Switzerland. PATIENTS: Preterm infants between 26 0/7 and 31 6/7 weeks gestation INTERVENTIONS: Infants were randomised to receive positive distending pressure alone or positive distending pressure and additional SN (200 mg/kg; poractant alfa) using a customised vibrating membrane nebuliser. SN commenced with the first application of a face mask immediately after birth. MAIN OUTCOME MEASURES: Primary outcome was the difference in end-expiratory lung impedance from birth to 30 min after birth (∆EELI30min). EELI correlates well with functional residual capacity. Secondary outcomes included physiological and clinical outcomes. RESULTS: Data from 35 infants were collected, and primary outcome data were analysed from 32 infants (n=16/group). Primary outcome was not different between intervention and control group (median (IQR): 25 (7-62) vs 10 (0-26) AU/kg, p=0.21). ∆EELI was slightly higher in the intervention group at 6 and 12 hours after birth, particularly in the central areas of the lung. There were no differences in cardiorespiratory and clinical parameters. Two adverse events were noted in the intervention group. CONCLUSIONS: Prophylactic SN in the DR did not significantly affect ∆EELI30min and showed only minimal effects on lung physiology. Prophylactic SN in the DR was feasible. There were no differences in clinical outcomes. TRIAL REGISTRATION NUMBER: NCT04315636.


Subject(s)
Infant, Premature , Pulmonary Surfactants , Infant , Infant, Newborn , Humans , Surface-Active Agents , Continuous Positive Airway Pressure , Lung
8.
Arch Dis Child Fetal Neonatal Ed ; 108(2): 170-175, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36038255

ABSTRACT

OBJECTIVE: Mechanisms of non-invasive high-frequency oscillatory ventilation (nHFOV) in preterm infants are unclear. We aimed to compare lung volume changes during apnoeas in preterm infants on nHFOV and nasal continuous positive airway pressure (nCPAP). METHODS: Analysis of electrical impedance tomography (EIT) data from a randomised crossover trial comparing nHFOV with nCPAP in preterm infants at 26-34 weeks postmenstrual age. EIT data were screened by two reviewers to identify apnoeas ≥10 s. End-expiratory lung impedance (EELI) and tidal volumes (VT) were calculated before and after apnoeas. Oxygen saturation (SpO2) and heart rate (HR) were extracted for 60 s after apnoeas. RESULTS: In 30 preterm infants, 213 apnoeas were identified. During apnoeas, oscillatory volumes were detectable during nHFOV. EELI decreased significantly during apnoeas (∆EELI nCPAP: -8.0 (-11.9 to -4.1) AU/kg, p<0.001; ∆EELI nHFOV: -3.4 (-6.5 to -0.3), p=0.03) but recovered over the first five breaths after apnoeas. Compared with before apnoeas, VT was increased for the first breath after apnoeas during nCPAP (∆VT: 7.5 (3.1 to 11.2) AU/kg, p=0.001). Falls in SpO2 and HR after apnoeas were greater during nCPAP than nHFOV (mean difference (95% CI): SpO2: 3.6% (2.7 to 4.6), p<0.001; HR: 15.9 bpm (13.4 to 18.5), p<0.001). CONCLUSION: Apnoeas were characterised by a significant decrease in EELI which was regained over the first breaths after apnoeas, partly mediated by a larger VT. Apnoeas were followed by a considerable drop in SpO2 and HR, particularly during nCPAP, leading to longer episodes of hypoxemia during nCPAP. Transmitted oscillations during nHFOV may explain these benefits. TRIAL REGISTRATION NUMBER: ACTRN12616001516471.


Subject(s)
Apnea , Infant, Premature , Respiratory Distress Syndrome, Newborn , Humans , Infant , Infant, Newborn , Continuous Positive Airway Pressure/methods , Intermittent Positive-Pressure Ventilation/methods , Tidal Volume , Cross-Over Studies
9.
Vet Rec ; 191(12): e2184, 2022 12.
Article in English | MEDLINE | ID: mdl-36197754

ABSTRACT

BACKGROUND: Electrical impedance tomography (EIT) produces lung ventilation images via a thoracic electrode belt. Robust electrode design and material, providing low electrode skin contact impedance (SCI), is needed in veterinary medicine. The aim of this study was to compare three EIT electrode designs and materials. METHODS: Simulations of cylindrical, rectangular and spiked electrode designs were used to evaluate electrode SCI as a function of electrode size, where skin contact was uneven. Gold-plated washers (EGW ), zinc-plated rivets (EZR ) and zinc-galvanised spikes (EZS ) were assigned randomly on two interconnected EIT belts. Gel was applied to the cranial or caudal belt and placed on 17 standing cattle. SCI was recorded at baseline and 3, 5, 7, 9 and 11 minutes later. RESULTS: Simulations that involved electrodes with a greater skin contact area had lower and more uniform SCI. In cattle, SCI decreased with all electrodes over time (p < 0.01). Without gel, no difference was found between EGW and EZS , while SCI was higher for EZR (p < 0.03). With gel, SCI was lower in EGW and EZR (p < 0.026), with the SCI in EGW being the lowest (p < 0.01). LIMITATIONS: Low numbers of animals and static electrode position may affect SCI. CONCLUSIONS: Electrode design is important for EIT measurement, with larger electrode designs able to compensate for the use of less conductive materials. Gel is not necessary to achieve acceptable SCI in large animals.


Subject(s)
Tomography, X-Ray Computed , Tomography , Animals , Cattle , Tomography/veterinary , Tomography/methods , Electric Impedance , Electrodes , Zinc
10.
Front Vet Sci ; 9: 946911, 2022.
Article in English | MEDLINE | ID: mdl-35937293

ABSTRACT

Electrical impedance tomography (EIT) is a non-invasive real-time non-ionising imaging modality that has many applications. Since the first recorded use in 1978, the technology has become more widely used especially in human adult and neonatal critical care monitoring. Recently, there has been an increase in research on thoracic EIT in veterinary medicine. Real-time imaging of the thorax allows evaluation of ventilation distribution in anesthetised and conscious animals. As the technology becomes recognised in the veterinary community there is a need to standardize approaches to data collection, analysis, interpretation and nomenclature, ensuring comparison and repeatability between researchers and studies. A group of nineteen veterinarians and two biomedical engineers experienced in veterinary EIT were consulted and contributed to the preparation of this statement. The aim of this consensus is to provide an introduction to this imaging modality, to highlight clinical relevance and to include recommendations on how to effectively use thoracic EIT in veterinary species. Based on this, the consensus statement aims to address the need for a streamlined approach to veterinary thoracic EIT and includes: an introduction to the use of EIT in veterinary species, the technical background to creation of the functional images, a consensus from all contributing authors on the practical application and use of the technology, descriptions and interpretation of current available variables including appropriate statistical analysis, nomenclature recommended for consistency and future developments in thoracic EIT. The information provided in this consensus statement may benefit researchers and clinicians working within the field of veterinary thoracic EIT. We endeavor to inform future users of the benefits of this imaging modality and provide opportunities to further explore applications of this technology with regards to perfusion imaging and pathology diagnosis.

11.
Front Vet Sci ; 9: 895268, 2022.
Article in English | MEDLINE | ID: mdl-35836499

ABSTRACT

Equine respiratory physiology might be influenced by the presence of an endotracheal tube (ETT). This experimental, randomized cross-over study aimed to compare breathing pattern (BrP) and ventilation distribution in anesthetized horses spontaneously breathing room air via ETT or facemask (MASK). Six healthy adult horses were anesthetized with total intravenous anesthesia (TIVA; xylazine, ketamine, guaiphenesin), breathing spontaneously in right lateral recumbency, and randomly assigned to ETT or MASK for 30 min, followed by the other treatment for an additional 30 min. During a second anesthesia 1 month later, the treatment order was inversed. Electrical impedance tomography (EIT) using a thoracic electrode belt, spirometry, volumetric capnography, esophageal pressure difference (ΔPoes), venous admixture, and laryngoscopy data were recorded over 2 min every 15 min. Breaths were classified as normal or alternate (sigh or crown-like) according to the EIT impedance curve. A mixed linear model was used to test the effect of treatment on continuous outcomes. Cochran-Mantel-Haenszel analysis was used to test for associations between global BrP and treatment. Global BrP was associated with treatment (p = 0.012) with more alternate breaths during ETT. The center of ventilation right-to-left (CoVRL) showed more ventilation in the non-dependent lung during ETT (p = 0.025). The I:E ratio (p = 0.017) and ΔPoes (p < 0.001) were smaller, and peak expiratory flow (p = 0.009) and physiologic dead space (p = 0.034) were larger with ETT. The presence of an ETT alters BrP and shifts ventilation toward the non-dependent lung in spontaneously breathing horses anesthetized with TIVA.

12.
SAGE Open Med ; 10: 20503121221108927, 2022.
Article in English | MEDLINE | ID: mdl-35832259

ABSTRACT

Objective: In the delivery of intravenous fluids, in-line warming devices frequently transfer heat using a metal heating plate, which if uncoated can risk elution. This bench study examined extractable elements detected following long-term use of the parylene-coated enFlow® Disposable IV/Blood Warmer. Methods: We tested 16 clinically relevant challenge fluids typical of the surgical setting, including commercially available single donor blood and blood products as well as intravenous saline and electrolyte solutions. After 72 h of warming at 40°C (104°F) via the enFlow, analytical chemistry identified and quantified the most clinically significant extractable elements (arsenic, barium, cadmium, copper, and lead) to estimate chemical exposure. We also measured the extracted concentrations of these five elements following simulated use of the device with three solutions (Sterofundin ISO, Plasma-Lyte 148, and whole blood) that were pumped through the warmed device at two different flow rates (0.2 and 5.5 mL min-1). Results: Across all scenarios of acute and long-term exposures for different populations, the enFlow demonstrated low toxicological risks as measured by the calculation of tolerable exposure for extracted arsenic, barium, cadmium, copper, and lead. Conclusion: The results suggest biological safety for the use of parylene-coated enFlow with a variety of intravenous solutions and in different therapeutic scenarios.

13.
Neonatology ; 119(4): 525-529, 2022.
Article in English | MEDLINE | ID: mdl-35398844

ABSTRACT

Hiccups occur at all ages but are most common during fetal development, and accordingly, they are seen regularly in preterm infants. However, the physiologic correlate of hiccups has never been established. We present the case of a preterm infant who developed a spell of hiccups and compared lung volume changes during hiccups with spontaneous breaths using electrical impedance tomography. Hiccups mostly occurred during the expiratory phase of breathing and were associated with a shorter inspiratory time and a larger tidal volume compared with spontaneous breaths. The center of ventilation was shifted toward the ventral (non-gravity-dependent) part of the lung during hiccups and volume changes were mainly restricted to the larger airways, but some gas flow also reached the lung parenchyma. Our observations shed new light on this phenomenon, which is well known but little researched, and our findings may imply a physiological impact of hiccups during fetal development.


Subject(s)
Hiccup , Infant, Newborn, Diseases , Hiccup/etiology , Humans , Infant , Infant, Newborn , Infant, Premature/physiology , Lung/diagnostic imaging , Respiration , Tidal Volume
14.
Arch Dis Child Fetal Neonatal Ed ; 107(5): 551-557, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35101993

ABSTRACT

INTRODUCTION: Non-invasive high-frequency oscillatory ventilation (nHFOV) is an extension of nasal continuous positive airway pressure (nCPAP) support in neonates. We aimed to compare global and regional distribution of lung volumes during nHFOV versus nCPAP. METHODS: In 30 preterm infants enrolled in a randomised crossover trial comparing nHFOV with nCPAP, electrical impedance tomography data were recorded in prone position. For each mode of respiratory support, four episodes of artefact-free tidal ventilation, each comprising 30 consecutive breaths, were extracted. Tidal volumes (VT) in 36 horizontal slices, indicators of ventilation homogeneity and end-expiratory lung impedance (EELI) for the whole lung and for four horizontal regions of interest (non-gravity-dependent to gravity-dependent; EELINGD, EELImidNGD, EELImidGD, EELIGD) were compared between nHFOV and nCPAP. Aeration homogeneity ratio (AHR) was determined by dividing aeration in non-gravity-dependent parts of the lung through gravity-dependent regions. MAIN RESULTS: Overall, 228 recordings were analysed. Relative VT was greater in all but the six most gravity-dependent lung slices during nCPAP (all p<0.05). Indicators of ventilation homogeneity were similar between nHFOV and nCPAP (all p>0.05). Aeration was increased during nHFOV (mean difference (95% CI)=0.4 (0.2 to 0.6) arbitrary units per kilogram (AU/kg), p=0.013), mainly due to an increase in non-gravity-dependent regions of the lung (∆EELINGD=6.9 (0.0 to 13.8) AU/kg, p=0.028; ∆EELImidNGD=6.8 (1.2 to 12.4) AU/kg, p=0.009). Aeration was more homogeneous during nHFOV compared with nCPAP (mean difference (95% CI) in AHR=0.01 (0.00 to 0.02), p=0.0014). CONCLUSION: Although regional ventilation was similar between nHFOV and nCPAP, end-expiratory lung volume was higher and aeration homogeneity was slightly improved during nHFOV. The aeration difference was greatest in non-gravity dependent regions, possibly due to the oscillatory pressure waveform. The clinical importance of these findings is still unclear.


Subject(s)
High-Frequency Ventilation , Noninvasive Ventilation , Continuous Positive Airway Pressure/methods , High-Frequency Ventilation/methods , Humans , Infant , Infant, Newborn , Infant, Premature , Intermittent Positive-Pressure Ventilation/methods , Noninvasive Ventilation/methods , Tidal Volume
15.
BMC Anesthesiol ; 22(1): 44, 2022 02 10.
Article in English | MEDLINE | ID: mdl-35144541

ABSTRACT

BACKGROUND: Perioperative hypothermia is a common occurrence, particularly with the elderly and pediatric age groups. Hypothermia is associated with an increased risk of perioperative complications. One method of preventing hypothermia is warming the infused fluids given during surgery. The enFlow™ intravenous fluid warmer has recently been reintroduced with a parylene coating on its heating blocks. In this paper, we evaluated the impact of the parylene coating on the new enFlow's fluid warming capacity. METHODS: Six coated and six uncoated enFlow cartridges were used. A solution of 10% propylene glycol and 90% distilled H2O was infused into each heating cartridge at flow rates of 2, 10, 50, 150, and 200 ml/min. The infused fluid temperature was set at 4 °C, 20 °C, and 37 °C. Output temperature was recorded at each level. Data for analysis was derived from 18 runs at each flow rate (six cartridges at three temperatures). RESULTS: The parylene coated fluid warming cartridge delivered very stable output of 40 °C temperatures at flow rates of 2, 10, and 50 ml/min regardless of the temperature of the infusate. At higher flow rates, the cartridges were not able to achieve the target temperature with the colder fluid. Both cartridges performed with similar efficacy across all flow rates at all temperatures. CONCLUSIONS: At low flow rates, the parylene coated enFlow cartridges was comparable to the original uncoated cartridges. At higher flow rates, the coated and uncoated cartridges were not able to achieve the target temperature. The parylene coating on the aluminum heating blocks of the new enFlow intravenous fluid warmer does not negatively affect its performance compared to the uncoated model.


Subject(s)
Administration, Intravenous/methods , Heating/instrumentation , Heating/methods , Polymers , Xylenes , Equipment Design , Humans , Infusions, Intravenous
16.
Pediatr Res ; 92(1): 242-248, 2022 07.
Article in English | MEDLINE | ID: mdl-34465873

ABSTRACT

OBJECTIVE: To measure changes in end-expiratory lung impedance (EELI) as a marker of functional residual capacity (FRC) during the entire extubation procedure of very preterm infants. METHODS: Prospective observational study in preterm infants born at 26-32 weeks gestation being extubated to non-invasive respiratory support. Changes in EELI and cardiorespiratory parameters (heart rate, oxygen saturation) were recorded at pre-specified events during the extubation procedure compared to baseline (before first handling of the infant). RESULTS: Overall, 2912 breaths were analysed in 12 infants. There was a global change in EELI during the extubation procedure (p = 0.029). EELI was lowest at the time of extubation [median (IQR) difference to baseline: -0.30 AU/kg (-0.46; -0.14), corresponding to an FRC loss of 10.2 ml/kg (4.8; 15.9), padj = 0.004]. The biggest EELI loss occurred during adhesive tape removal [median change (IQR): -0.18 AU/kg (-0.22; -0.07), padj = 0.004]. EELI changes were highly correlated with changes in the SpO2/FiO2 ratio (r = 0.48, p < 0.001). Forty per cent of FRC was re-recruited at the tenth breath after the initiation of non-invasive ventilation (p < 0.001). CONCLUSIONS: The extubation procedure is associated with significant changes in FRC. This study provides novel information for determining the optimal way of extubating a preterm infant. IMPACT: This study is the first to examine the development of lung volumes during the entire extubation procedure including the impact of associated events. The extubation procedure significantly affects functional residual capacity with a loss of approximately 10 ml/kg at the time of extubation. Removal of adhesive tape is the major contributing factor to FRC loss during the extubation procedure. Functional residual capacity is regained within the first breaths after initiation of non-invasive ventilation and is further increased after turning the infant into the prone position.


Subject(s)
Airway Extubation , Infant, Premature , Functional Residual Capacity , Humans , Infant, Newborn , Infant, Premature/physiology , Lung Volume Measurements , Respiration, Artificial
17.
Ann Am Thorac Soc ; 19(6): 991-999, 2022 06.
Article in English | MEDLINE | ID: mdl-34898392

ABSTRACT

Rationale: Electrical impedance tomography (EIT) allows instantaneous and continuous visualization of regional ventilation and changes in end-expiratory lung volume at the bedside. There is particular interest in using EIT for monitoring in critically ill neonates and young children with respiratory failure. Previous studies have focused only on short-term monitoring in small populations. The feasibility and safety of prolonged monitoring with EIT in neonates and young children have not been demonstrated yet. Objectives: To evaluate the feasibility and safety of long-term EIT monitoring in a routine clinical setting and to describe changes in ventilation distribution and homogeneity over time and with positioning in a multicenter cohort of neonates and young children with respiratory failure. Methods: At four European University hospitals, we conducted an observational study (NCT02962505) on 200 patients with postmenstrual ages (PMA) between 25 weeks and 36 months, at risk for or suffering from respiratory failure. Continuous EIT data were obtained using a novel textile 32-electrode interface and recorded at 48 images/s for up to 72 hours. Clinicians were blinded to EIT images during the recording. EIT parameters and the effects of body position on ventilation distribution were analyzed offline. Results: The average duration of EIT measurements was 53 ± 20 hours. Skin contact impedance was sufficient to allow image reconstruction for valid ventilation analysis during a median of 92% (interquartile range, 77-98%) of examination time. EIT examinations were well tolerated, with minor skin irritations (temporary redness or imprint) occurring in 10% of patients and no moderate or severe adverse events. Higher ventilation amplitude was found in the dorsal and right lung areas when compared with the ventral and left regions, respectively. Prone positioning resulted in an increase in the ventilation-related EIT signal in the dorsal hemithorax, indicating increased ventilation of the dorsal lung areas. Lateral positioning led to a redistribution of ventilation toward the dependent lung in preterm infants and to the nondependent lung in patients with PMA > 37 weeks. Conclusions: EIT allows continuous long-term monitoring of regional lung function in neonates and young children for up to 72 hours with minimal adverse effects. Our study confirmed the presence of posture-dependent changes in ventilation distribution and their dependency on PMA in a large patient cohort. Clinical trial registered with www.clinicaltrials.gov (NCT02962505).


Subject(s)
Respiratory Insufficiency , Tomography , Child , Child, Preschool , Electric Impedance , Humans , Infant , Infant, Newborn , Infant, Premature , Lung/diagnostic imaging , Respiratory Insufficiency/diagnosis , Respiratory Insufficiency/therapy , Tomography/methods
18.
J Vet Intern Med ; 35(5): 2500-2510, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34505734

ABSTRACT

BACKGROUND: Equine asthma (EA) causes airflow impairment, which increases in severity with exercise. Electrical impedance tomography (EIT) is an imaging technique that can detect airflow changes in standing healthy horses during a histamine provocation test. OBJECTIVES: To explore EIT-calculated flow variables before and after exercise in healthy horses and horses with mild-to-moderate (MEA) and severe equine asthma (SEA). ANIMALS: Nine healthy horses 9 horses diagnosed with MEA and 5 with SEA were prospectively included. METHODS: Recordings were performed before and after 15 minutes of lunging. Absolute values from global and regional peak inspiratory (PIF, positive value) and expiratory (PEF, negative value) flows were calculated. Data were analyzed using a mixed model analysis followed by Bonferroni's multiple comparisons test to evaluate the impact of exercise and diagnosis on flow indices. RESULTS: Control horses after exercise had significantly lower global PEF and PIF compared to horses with SEA (mean difference [95% confidence interval, CI]: 0.0859 arbitrary units [AU; 0.0339-0.1379], P < .001 and 0.0726 AU [0.0264-0.1188], P = .001, respectively) and horses with MEA (0.0561 AU [0.0129-0.0994], P = .007 and 0.0587 AU [0.0202-0.0973], P = .002, respectively). No other significant differences were detected. CONCLUSIONS AND CLINICAL IMPORTANCE: Electrical impedance tomography derived PIF and PEF differed significantly between healthy horses and horses with SEA or MEA after exercise, but not before exercise. Differences between MEA and SEA were not observed, but the study population was small.


Subject(s)
Asthma , Horse Diseases , Animals , Asthma/veterinary , Electric Impedance , Horse Diseases/diagnostic imaging , Horses , Lung , Respiration , Tomography, X-Ray Computed
19.
Front Physiol ; 12: 693736, 2021.
Article in English | MEDLINE | ID: mdl-34349666

ABSTRACT

Transpulmonary driving pressure (DPL) corresponds to the cyclical stress imposed on the lung parenchyma during tidal breathing and, therefore, can be used to assess the risk of ventilator-induced lung injury (VILI). Its measurement at the bedside requires the use of esophageal pressure (Peso), which is sometimes technically challenging. Recently, it has been demonstrated how in an animal model of ARDS, the transpulmonary pressure (PL) measured with Peso calculated with the absolute values method (PL = Paw-Peso) is equivalent to the transpulmonary pressure directly measured using pleural sensors in the central-dependent part of the lung. We hypothesized that, since the PL derived from Peso reflects the regional behavior of the lung, it could exist a relationship between regional parameters measured by electrical impedance tomography (EIT) and driving PL (DPL). Moreover, we explored if, by integrating airways pressure data and EIT data, it could be possible to estimate non-invasively DPL and consequently lung elastance (EL) and elastance-derived inspiratory PL (PI). We analyzed 59 measurements from 20 patients with ARDS. There was a significant intra-patient correlation between EIT derived regional compliance in regions of interest (ROI1) (r = 0.5, p = 0.001), ROI2 (r = -0.68, p < 0.001), and ROI3 (r = -0.4, p = 0.002), and DPL. A multiple linear regression successfully predicted DPL based on respiratory system elastance (Ers), ideal body weight (IBW), roi1%, roi2%, and roi3% (R 2 = 0.84, p < 0.001). The corresponding Bland-Altmann analysis showed a bias of -1.4e-007 cmH2O and limits of agreement (LoA) of -2.4-2.4 cmH2O. EL and PI calculated using EIT showed good agreement (R 2 = 0.89, p < 0.001 and R 2 = 0.75, p < 0.001) with the esophageal derived correspondent variables. In conclusion, DPL has a good correlation with EIT-derived parameters in the central lung. DPL, PI, and EL can be estimated with good accuracy non-invasively combining information coming from EIT and airway pressure.

20.
Animals (Basel) ; 11(5)2021 May 10.
Article in English | MEDLINE | ID: mdl-34068514

ABSTRACT

This study explores the application of electric impedance tomography (EIT) to estimate tidal volume (VT) by measuring impedance change per breath (∆Zbreath). Seventeen healthy horses were anaesthetised and mechanically ventilated for elective procedures requiring dorsal recumbency. Spirometric VT (VTSPIRO) and ∆Zbreath were recorded periodically; up to six times throughout anaesthesia. Part 1 assessed these variables at incremental delivered VT of 10, 12 and 15 mL/kg. Part 2 estimated VT (VTEIT) in litres from ∆Zbreath at three additional measurement points using a line of best fit obtained from Part 1. During part 2, VT was adjusted to maintain end-tidal carbon dioxide between 45-55 mmHg. Linear regression determined the correlation between VTSPIRO and ∆Zbreath (part 1). Estimated VTEIT was assessed for agreement with measured VTSPIRO using Bland Altman analysis (part 2). Marked variability in slope and intercepts was observed across horses. Strong positive correlation between ∆Zbreath and VTSPIRO was found in each horse (R2 0.9-0.99). The agreement between VTEIT and VTSPIRO was good with bias (LOA) of 0.26 (-0.36-0.88) L. These results suggest that, in anaesthetised horses, EIT can be used to monitor and estimate VT after establishing the individual relationship between these variables.