Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Cyst Fibros ; 22(4): 715-721, 2023 07.
Article in English | MEDLINE | ID: mdl-37400300

ABSTRACT

BACKGROUND: Medical radiation exposure is of increasing concern in patients with cystic fibrosis (PWCF) due to improving life expectancy. We aimed to assess and quantify the cumulative effective dose (CED) in PWCF in the context of CFTR-modulator therapy and the advancement of dose reduction techniques. METHODS: We performed a retrospective observational study in a single University CF centre over a 11-year period. We included PWCF, aged over 18 years who exclusively attended our institution. Relevant clinical data (demographics, transplantation history and modulator status) and radiological data (modality, quantity, and radiation exposure measured as CED) were collected. For those on modulator therapy the quantified imaging and radiation data was dichotomised into pre-and-post therapy periods. RESULTS: The study included 181 patients: 139 on CFTR modulator therapy, 15 transplant recipients and 27 with neither exposure. 82% of patients received <25 mSv over the study period. Mean study duration was 6.9 ± 2.6 years pre-modulation and 4.2 ± 2.6 years post-modulation. Pre-modulation CT contributed 9.6% of total chest imaging (n = 139/1453) and 70.9% of the total CED. Post-modulation CT use increased contributing 42.7% of chest imaging (n = 444/1039) and comprised 75.8% of CED. Annual CED was 1.55 mSv pre and 1.36 mSv post modulation (p = 0.41). Transplant recipients had an annual CED of 64 ± 36.1mSv. CONCLUSION: Chest CT utilisation for PWCF is rising in our institution, replacing chest radiography amidst CFTR-modulation. Despite the increasing use of CT, no significant radiation dose penalty was observed with a reduction in mean annual CED, primarily due to the influence of CT dose reduction strategies.


Subject(s)
Cystic Fibrosis , Humans , Adult , Middle Aged , Cystic Fibrosis/diagnostic imaging , Cystic Fibrosis Transmembrane Conductance Regulator/genetics , Radiation Dosage , Tomography, X-Ray Computed/methods , Radiography , Thorax
2.
Children (Basel) ; 10(4)2023 Mar 30.
Article in English | MEDLINE | ID: mdl-37189893

ABSTRACT

Children with congenital heart disease are exposed to repeated medical imaging throughout their lifetime. Although the imaging contributes to their care and treatment, exposure to ionising radiation is known to increase one's lifetime attributable risk of malignancy. A systematic search of multiple databases was performed. Inclusion and exclusion criteria were applied to all relevant papers and seven were deemed acceptable for quality assessment and risk of bias assessment. The cumulative effective dose (CED) varied widely across the patient cohorts, ranging from 0.96 mSv to 53.5 mSv. However, it was evident across many of the included studies that a significant number of patients were exposed to a CED >20 mSv, the current annual occupational exposure limit. Many factors affected the dose which patients received, including age and clinical demographics. The imaging modality which contributed the most radiation dose to patients was cardiology interventional procedures. Paediatric patients with congenital heart disease are at an increased risk of receiving an elevated cumulative radiation dose across their lifetime. Further research should focus on identifying risk factors for receiving higher radiation doses, keeping track of doses, and dose optimisation where possible.

3.
Diagnostics (Basel) ; 12(12)2022 Nov 23.
Article in English | MEDLINE | ID: mdl-36552922

ABSTRACT

Post-embolisation syndrome (PES) is a prevalent complication that occurs in patients following uterine artery embolisation (UAE) for the treatment of uterine fibroids. The aetiology of PES remains incompletely understood, although postulated to result secondary to tissue infarction resulting in release of inflammatory mediators. We followed PRISMA guidelines and performed a systematic review of studies of PES following UAE from inception to October 2022. Our published protocol was prospectively registered. Our search yielded 54 results. We reviewed 22 full texts, and nine articles were included. Observational studies comprised 6/9 relevant studies, with 5/9 retrospective design. The rate of PES was documented in 5/8 studies (excluding case report) with a reported incidence ranging from 4-34.6%. Five of the nine studies studies postulated that the aetiological basis of PES is inflammatory related. Further research is necessary to advance our understanding of PES to define the biological basis of the syndrome with more certainty and gain a consensus on peri-procedure management to reduce incidence and improve patient outcomes.

SELECTION OF CITATIONS
SEARCH DETAIL
...