Water Sci Technol ; 66(2): 457-63, 2012.
Article in English | MEDLINE | ID: mdl-22699354

ABSTRACT

This study analyzes the effect of inoculating membrane bioreactor (MBR) sludge in a parallel-operated overloaded conventional activated sludge (CAS) system. Modelling studies that showed the beneficial effect of this inoculation were confirmed though full scale tests. Total nitrogen (TN) removal in the CAS increased and higher nitrate formation rates were achieved. During MBR sludge inoculation, the TN removal in the CAS was proven to be dependent on MBR sludge loading. Special attention was given to the effect of inoculation on sludge quality. The MBR flocs, grown without selection pressure, were clearly distinct from the more compact flocs in the CAS system and also contained more filamentous bacteria. After inoculation the MBR flocs did not evolve into good-settling compact flocs, resulting in a decreasing sludge quality. During high flow conditions the effluent CAS contained more suspended solids. Sludge volume index, however, did not increase. Laboratory tests were held to determine the threshold volume of MBR sludge to be seeded into the CAS reactor. Above 16-30%, supernatant turbidity and scum formation increased markedly.


Subject(s)
Bioreactors/microbiology , Membranes, Artificial , Sewage/microbiology
2.
Water Sci Technol ; 63(1): 164-70, 2011.
Article in English | MEDLINE | ID: mdl-21245569

ABSTRACT

An ASM2da model of the full-scale waste water plant of Bree (Belgium) has been made. It showed very good correlation with reference operational data. This basic model has been extended to include an accurate calculation of environmental footprint and operational costs (energy consumption, dosing of chemicals and sludge treatment). Two optimisation strategies were compared: lowest cost meeting the effluent consent versus lowest environmental footprint. Six optimisation scenarios have been studied, namely (i) implementation of an online control system based on ammonium and nitrate sensors, (ii) implementation of a control on MLSS concentration, (iii) evaluation of internal recirculation flow, (iv) oxygen set point, (v) installation of mixing in the aeration tank, and (vi) evaluation of nitrate setpoint for post denitrification. Both an environmental impact or Life Cycle Assessment (LCA) based approach for optimisation are able to significantly lower the cost and environmental footprint. However, the LCA approach has some advantages over cost minimisation of an existing full-scale plant. LCA tends to chose control settings that are more logic: it results in a safer operation of the plant with less risks regarding the consents. It results in a better effluent at a slightly increased cost.


Subject(s)
Costs and Cost Analysis , Water Pollutants, Chemical , Belgium