Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
1.
J Feline Med Surg ; 20(4): 362-369, 2018 04.
Article in English | MEDLINE | ID: mdl-28589743

ABSTRACT

Objectives Feline leukaemia virus (FeLV), a gamma retrovirus, causes diseases of the feline haematopoietic system that are invariably fatal. Rapid and accurate testing at the point-of-need (PON) supports prevention of virus spread and management of clinical disease. This study evaluated the performance of an insulated isothermal PCR (iiPCR) that detects proviral DNA, and a reverse transcription (RT)-iiPCR that detects both viral RNA and proviral DNA, for FeLV detection at the PON. Methods Mycoplasma haemofelis, feline coronavirus, feline herpesvirus, feline calicivirus and feline immunodeficiency virus were used to test analytical specificity. In vitro transcribed RNA, artificial plasmid, FeLV strain American Type Culture Collection VR-719 and a clinical FeLV isolate were used in the analytical sensitivity assays. A retrospective study including 116 clinical plasma and serum samples that had been tested with virus isolation, real-time PCR and ELISA, and a prospective study including 150 clinical plasma and serum samples were implemented to evaluate the clinical performances of the iiPCR-based methods for FeLV detection. Results Ninety-five percent assay limit of detection was calculated to be 16 RNA and five DNA copies for the RT-iiPCR, and six DNA copies for the iiPCR. Both reactions had analytical sensitivity comparable to a reference real-time PCR (qPCR) and did not detect five non-target feline pathogens. The clinical performance of the RT-iiPCR and iiPCR had 98.82% agreement (kappa[κ] = 0.97) and 100% agreement (κ = 1.0), respectively, with the qPCR (n = 85). The agreement between an automatic nucleic extraction/RT-iiPCR system and virus isolation to detect FeLV in plasma or serum was 95.69% (κ = 0.95) and 98.67% (κ = 0.85) in a retrospective (n = 116) and a prospective (n = 150) study, respectively. Conclusions and relevance These results suggested that both RT-iiPCR and iiPCR assays can serve as reliable tools for PON FeLV detection.


Subject(s)
Feline Acquired Immunodeficiency Syndrome/diagnosis , Immunodeficiency Virus, Feline/isolation & purification , Real-Time Polymerase Chain Reaction/veterinary , Animals , Cats , Feline Acquired Immunodeficiency Syndrome/virology , Polymerase Chain Reaction/veterinary , Prospective Studies , RNA, Viral/analysis , Retrospective Studies , Sensitivity and Specificity
2.
BMC Infect Dis ; 17(1): 778, 2017 12 19.
Article in English | MEDLINE | ID: mdl-29258444

ABSTRACT

BACKGROUND: The recent emergence of Zika virus (ZIKV) in Brazil and its precipitous expansion throughout the Americas has highlighted the urgent need for a rapid and reliable on-site diagnostic assay suitable for viral detection. Such point-of-need (PON), low-cost diagnostics are essential for ZIKV control in vulnerable areas with limited resources. METHODS: We developed and evaluated a ZIKV-specific field-deployable RT-iiPCR reagent set targeting the E gene for rapid detection of ZIKV in ZIKV-spiked human and mosquito specimens, and compared its performance to the Center for Disease Control and Prevention (CDC) and Pan American Health Organization (PAHO) RT-qPCR assays targeting the E and NS2B genes, respectively. RESULTS: These assays demonstrated exclusive specificity for ZIKV (African and Asian lineages), had limits of detection ranging from 10 to 100 in vitro transcribed RNA copies/µl and detection endpoints at 10 plaque forming units/ml of infectious tissue culture fluid. Analysis of human whole blood, plasma, serum, semen, urine, and mosquito pool samples spiked with ZIKV showed an agreement of 90% (k = 0.80), 92% (k = 0.82), 95% (k = 0.86), 92% (k = 0.81), 90% (k = 0.79), and 100% (k = 1), respectively, between the RT-iiPCR assay and composite results from the reference RT-qPCR assays. Overall, the concurrence between the ZIKV RT-iiPCR and the reference RT-qPCR assays was 92% (k = 0.83). CONCLUSIONS: The ZIKV RT-iiPCR has a performance comparable to the reference CDC and PAHO RT-qPCR assays but provides much faster results (~1.5 h) with a field-deployable system that can be utilized as a PON diagnostic with the potential to significantly improve the quality of the health care system in vulnerable areas.


Subject(s)
RNA, Viral/analysis , Zika Virus Infection/diagnosis , Zika Virus/genetics , Animals , Culicidae/virology , Humans , Point-of-Care Systems , RNA, Viral/blood , RNA, Viral/urine , Real-Time Polymerase Chain Reaction , Sensitivity and Specificity , Zika Virus/isolation & purification , Zika Virus Infection/virology
3.
J Virol Methods ; 235: 99-104, 2016 09.
Article in English | MEDLINE | ID: mdl-27180038

ABSTRACT

There is no gold standard for detection of Rotavirus Group A (RVA), one of the main causes of diarrhea in neonatal animals. Sensitive and specific real-time RT-PCR (rtRT-PCR) assays are available for RVA but require submission of the clinical samples to diagnostic laboratories. Patient-side immunoassays for RVA protein detection have shown variable results, particularly with samples from unintended species. A sensitive and specific test for detection of RVA on the farm would facilitate rapid management decisions. The insulated isothermal RT-PCR (RT-iiPCR) assay works in a portable machine to allow sensitive and specific on-site testing. The aim of this investigation was to evaluate a commercially available RT-iiPCR assay for RVA detection in feces from different animal species. This assay was compared to an in-house rtRT-PCR assay and a commercially available rtRT-PCR kit, as well as an ELISA and EM for RVA detection. All three PCR assays targeted the well-conserved NSP5 gene. Clinical fecal samples from 108 diarrheic animals (mainly cattle and horses) were tested. The percentage of positive samples by ELISA, EM, in-house rtRT-PCR, commercial rtRT-PCR, and RT-iiPCR was 29.4%, 31%, 36.7%, 51.4%, 56.9%, respectively. The agreement between different assays was high (81.3-100%) in samples containing high viral loads. The sensitivity of the RT-iiPCR assay appeared to be higher than the commercially available rtRT-PCR assay, with a limit of detection (95% confidence index) of 3-4 copies of in vitro transcribed dsRNA. In conclusion, the user-friendly, field-deployable RT-iiPCR system holds substantial promise for on-site detection of RVA.


Subject(s)
Enzyme-Linked Immunosorbent Assay , Feces/virology , Microscopy, Electron , Reverse Transcriptase Polymerase Chain Reaction , Rotavirus Infections/veterinary , Rotavirus/isolation & purification , Animals , Cattle , Cattle Diseases/diagnosis , Cattle Diseases/virology , Diarrhea/virology , Horse Diseases/diagnosis , Horse Diseases/virology , Horses , Point-of-Care Systems , RNA, Double-Stranded , RNA, Viral/genetics , RNA, Viral/isolation & purification , Reagent Kits, Diagnostic , Real-Time Polymerase Chain Reaction , Rotavirus/genetics , Rotavirus Infections/diagnosis , Rotavirus Infections/virology , Sensitivity and Specificity , Temperature , Viral Load , Viral Nonstructural Proteins/genetics
4.
J Virol Methods ; 234: 7-15, 2016 08.
Article in English | MEDLINE | ID: mdl-27036504

ABSTRACT

Equine arteritis virus (EAV) is the causative agent of equine viral arteritis (EVA), a respiratory and reproductive disease of horses. Most importantly, EAV induces abortion in pregnant mares and can establish persistent infection in up to 10-70% of the infected stallions, which will continue to shed the virus in their semen. The objective of this study was to develop and evaluate a reverse transcription insulated isothermal polymerase chain reaction (RT-iiPCR) for the detection of EAV in semen and tissue samples. The newly developed assay had a limit of detection of 10 RNA copies and a 10-fold higher sensitivity than a previously described real-time RT-PCR (RT-qPCR). Evaluation of 125 semen samples revealed a sensitivity and specificity of 98.46% and 100.00%, respectively for the RT-qPCR assay, and 100.00% and 98.33%, respectively for the RT-iiPCR assay. Both assays had the same accuracy (99.2%, k=0.98) compared to virus isolation. Corresponding values derived from testing various tissue samples (n=122) collected from aborted fetuses, foals, and EAV carrier stallions are as follows: relative sensitivity, specificity, and accuracy of 88.14%, 96.83%, and 92.62% (k=0.85), respectively for the RT-qPCR assay, and 98.31%, 92.06%, and 95.08% (k=0.90), respectively for the RT-iiPCR assay. These results indicate that RT-iiPCR is a sensitive, specific, and a robust test enabling detection of EAV in semen and tissue samples with very considerable accuracy. Even though the RT-qPCR assay showed a sensitivity and specificity equal to virus isolation for semen samples, its diagnostic performance was somewhat limited for tissue samples. Thus, this new RT-iiPCR could be considered as an alternative tool in the implementation of EAV control and prevention strategies.


Subject(s)
Arterivirus Infections/veterinary , Equartevirus/isolation & purification , Horse Diseases/diagnosis , Reverse Transcriptase Polymerase Chain Reaction/veterinary , Semen/virology , Animals , Arterivirus Infections/diagnosis , Arterivirus Infections/prevention & control , Arterivirus Infections/virology , Female , Horse Diseases/virology , Horses , Male , Open Reading Frames , Pregnancy , RNA, Viral/genetics , Reverse Transcriptase Polymerase Chain Reaction/methods , Sensitivity and Specificity , Temperature
5.
J Virol Methods ; 220: 35-8, 2015 Aug.
Article in English | MEDLINE | ID: mdl-25889355

ABSTRACT

Canine parvovirus type 2 (CPV-2), including subtypes 2a, 2b and 2c, causes an acute enteric disease in both domestic and wild animals. Rapid and sensitive diagnosis aids effective disease management at points of need (PON). A commercially available, field-deployable and user-friendly system, designed with insulated isothermal PCR (iiPCR) technology, displays excellent sensitivity and specificity for nucleic acid detection. An iiPCR method was developed for on-site detection of all circulating CPV-2 strains. Limit of detection was determined using plasmid DNA. CPV-2a, 2b and 2c strains, a feline panleukopenia virus (FPV) strain, and nine canine pathogens were tested to evaluate assay specificity. Reaction sensitivity and performance were compared with an in-house real-time PCR using serial dilutions of a CPV-2b strain and 100 canine fecal clinical samples collected from 2010 to 2014, respectively. The 95% limit of detection of the iiPCR method was 13 copies of standard DNA and detection limits for CPV-2b DNA were equivalent for iiPCR and real-time PCR. The iiPCR reaction detected CPV-2a, 2b and 2c and FPV. Non-targeted pathogens were not detected. Test results of real-time PCR and iiPCR from 99 fecal samples agreed with each other, while one real-time PCR-positive sample tested negative by iiPCR. Therefore, excellent agreement (k = 0.98) with sensitivity of 98.41% and specificity of 100% in detecting CPV-2 in feces was found between the two methods. In conclusion, the iiPCR system has potential to serve as a useful tool for rapid and accurate PON, molecular detection of CPV-2.


Subject(s)
Dog Diseases/diagnosis , Dog Diseases/virology , Parvoviridae Infections/veterinary , Parvovirus, Canine/isolation & purification , Point-of-Care Systems , Polymerase Chain Reaction/instrumentation , Polymerase Chain Reaction/methods , Animals , Dogs , Feces/virology , Parvoviridae Infections/diagnosis , Parvoviridae Infections/virology , Sensitivity and Specificity , Time Factors