Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
Add more filters










Publication year range
1.
Article in English | MEDLINE | ID: mdl-38712546

ABSTRACT

We report on the latest advancements in Microcrystal Electron Diffraction (3D ED/MicroED), as discussed during a symposium at the National Center for CryoEM Access and Training housed at the New York Structural Biology Center. This snapshot describes cutting-edge developments in various facets of the field and identifies potential avenues for continued progress. Key sections discuss instrumentation access, research applications for small molecules and biomacromolecules, data collection hardware and software, data reduction software, and finally reporting and validation. 3D ED/MicroED is still early in its wide adoption by the structural science community with ample opportunities for expansion, growth, and innovation.

2.
Structure ; 31(12): 1510-1517.e1, 2023 12 07.
Article in English | MEDLINE | ID: mdl-37536337

ABSTRACT

Electron diffraction from three dimensional crystals, as a technique for solving molecular structures, is rapidly increasing in popularity. The development of methodology and software has borrowed, to great effect, from macromolecular X-ray crystallography. However, standardization lags behind the development of the technique, and practitioners are forced to work with inadequate data formats that are unable to capture a full description of their experiments. This creates obstacles that are increasingly difficult to overcome as experiments become ever faster and the need for data autoprocessing becomes more pressing. We present a data format standard based on best practice from macromolecular crystallography and demonstrate how the adoption of this standard enabled autoprocessing of datasets collected with a high-throughput detector system.


Subject(s)
Electrons , Software , Cryoelectron Microscopy/methods , Crystallography, X-Ray , Macromolecular Substances/chemistry
3.
bioRxiv ; 2023 Nov 14.
Article in English | MEDLINE | ID: mdl-37292675

ABSTRACT

Cells evoke the DNA damage checkpoint (DDC) to inhibit mitosis in the presence of DNA double-strand breaks (DSBs) to allow more time for DNA repair. In budding yeast, a single irreparable DSB is sufficient to activate the DDC and induce cell cycle arrest prior to anaphase for about 12 to 15 hours, after which cells "adapt" to the damage by extinguishing the DDC and resuming the cell cycle. While activation of the DNA damage-dependent cell cycle arrest is well-understood, how it is maintained remains unclear. To address this, we conditionally depleted key DDC proteins after the DDC was fully activated and monitored changes in the maintenance of cell cycle arrest. Degradation of Ddc2ATRIP, Rad9, Rad24, or Rad53CHK2 results in premature resumption of the cell cycle, indicating that these DDC factors are required both to establish and to maintain the arrest. Dun1 is required for establishment, but not maintenance of arrest, whereas Chk1 is required for prolonged maintenance but not for initial establishment of the mitotic arrest. When the cells are challenged with 2 persistent DSBs, they remain permanently arrested. This permanent arrest is initially dependent on the continuous presence of Ddc2 and Rad53; however, after 15 hours both proteins become dispensable. Instead, the continued mitotic arrest is sustained by spindle-assembly checkpoint (SAC) proteins Mad1, Mad2, and Bub2 but not by Bub2's binding partner Bfa1. These data suggest that prolonged cell cycle arrest in response to 2 DSBs is achieved by a handoff from the DDC to specific components of the SAC. Furthermore, the establishment and maintenance of DNA damage-induced cell cycle arrest requires overlapping but different sets of factors.

4.
Acta Crystallogr A Found Adv ; 79(Pt 2): 180-191, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36862043

ABSTRACT

Because of the strong electron-atom interaction, the kinematic theory of diffraction cannot be used to describe the scattering of electrons by an assembly of atoms due to the strong dynamical diffraction that needs to be taken into account. In this paper, the scattering of high-energy electrons by a regular array of light atoms is solved exactly by applying the T-matrix formalism to the corresponding Schrödinger's equation in spherical coordinates. The independent atom model is used, where each atom is represented by a sphere with an effective constant potential. The validity of the forward scattering approximation and the phase grating approximation, assumed by the popular multislice method, is discussed, and an alternative interpretation of multiple scattering is proposed and compared with existing interpretations.

5.
IUCrJ ; 10(Pt 3): 270-287, 2023 May 01.
Article in English | MEDLINE | ID: mdl-36952226

ABSTRACT

Three-dimensional electron diffraction (3DED) from nanocrystals of biological macromolecules requires the use of very small crystals. These are typically less than 300 nm-thick in the direction of the electron beam due to the strong interaction between electrons and matter. In recent years, focused-ion-beam (FIB) milling has been used in the preparation of thin samples for 3DED. These instruments typically use a gallium liquid metal ion source. Inductively coupled plasma (ICP) sources in principle offer faster milling rates. Little work has been done to quantify the damage these sources cause to delicate biological samples at cryogenic temperatures. Here, an analysis of the effect that milling with plasma FIB (pFIB) instrumentation has on lysozyme crystals is presented. This work evaluates both argon and xenon plasmas and compares them with crystals milled with a gallium source. A milling protocol was employed that utilizes an overtilt to produce wedge-shaped lamellae with a shallow thickness gradient which yielded very thin crystalline samples. 3DED data were then acquired and standard data-processing statistics were employed to assess the quality of the diffraction data. An upper bound to the depth of the pFIB-milling damage layer of between 42.5 and 50 nm is reported, corresponding to half the thickness of the thinnest lamellae that resulted in usable diffraction data. A lower bound of between 32.5 and 40 nm is also reported, based on a literature survey of the minimum amount of diffracting material required for 3DED.

6.
J Mol Biol ; 434(11): 167599, 2022 06 15.
Article in English | MEDLINE | ID: mdl-35460671

ABSTRACT

PDBx/mmCIF, Protein Data Bank Exchange (PDBx) macromolecular Crystallographic Information Framework (mmCIF), has become the data standard for structural biology. With its early roots in the domain of small-molecule crystallography, PDBx/mmCIF provides an extensible data representation that is used for deposition, archiving, remediation, and public dissemination of experimentally determined three-dimensional (3D) structures of biological macromolecules by the Worldwide Protein Data Bank (wwPDB, wwpdb.org). Extensions of PDBx/mmCIF are similarly used for computed structure models by ModelArchive (modelarchive.org), integrative/hybrid structures by PDB-Dev (pdb-dev.wwpdb.org), small angle scattering data by Small Angle Scattering Biological Data Bank SASBDB (sasbdb.org), and for models computed generated with the AlphaFold 2.0 deep learning software suite (alphafold.ebi.ac.uk). Community-driven development of PDBx/mmCIF spans three decades, involving contributions from researchers, software and methods developers in structural sciences, data repository providers, scientific publishers, and professional societies. Having a semantically rich and extensible data framework for representing a wide range of structural biology experimental and computational results, combined with expertly curated 3D biostructure data sets in public repositories, accelerates the pace of scientific discovery. Herein, we describe the architecture of the PDBx/mmCIF data standard, tools used to maintain representations of the data standard, governance, and processes by which data content standards are extended, plus community tools/software libraries available for processing and checking the integrity of PDBx/mmCIF data. Use cases exemplify how the members of the Worldwide Protein Data Bank have used PDBx/mmCIF as the foundation for its pipeline for delivering Findable, Accessible, Interoperable, and Reusable (FAIR) data to many millions of users worldwide.


Subject(s)
Computational Biology , Crystallography , Databases, Protein , Software , Macromolecular Substances/chemistry , Molecular Biology , Protein Conformation , Semantics
7.
Protein Sci ; 31(1): 232-250, 2022 01.
Article in English | MEDLINE | ID: mdl-34747533

ABSTRACT

The DIALS software for the processing of X-ray diffraction data is presented, with an emphasis on how the suite may be used as a toolkit for data processing. The description starts with an overview of the history and intent of the toolkit, usage as an automated system, command-line use, and ultimately how new tools can be written using the API to perform bespoke analysis. Consideration is also made to the application of DIALS to techniques outside of macromolecular X-ray crystallography.


Subject(s)
Electronic Data Processing , Software , Crystallography, X-Ray
8.
Front Mol Biosci ; 8: 648603, 2021.
Article in English | MEDLINE | ID: mdl-34327213

ABSTRACT

The emerging field of microcrystal electron diffraction (MicroED) is of great interest to industrial researchers working in the drug discovery and drug development space. The promise of being able to routinely solve high-resolution crystal structures without the need to grow large crystals is very appealing. Despite MicroED's exciting potential, adoption across the pharmaceutical industry has been slow, primarily owing to a lack of access to specialized equipment and expertise. Here we present our experience building a small molecule MicroED service pipeline for members of the pharmaceutical industry. In the past year, we have examined more than fifty small molecule samples submitted by our clients, the majority of which have yielded data suitable for structure solution. We also detail our experience determining small molecule MicroED structures of pharmaceutical interest and offer some insights into the typical experimental outcomes. This experience has led us to conclude that small molecule MicroED adoption will continue to grow within the pharmaceutical industry where it is able to rapidly provide structures inaccessible by other methods.

9.
Am J Hosp Palliat Care ; 38(12): 1466-1469, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33550844

ABSTRACT

BACKGROUND: Timely administration of 'as-required' medication is important for managing patients' symptoms in palliative care. There are no national or local standards around the maximum length of time for the process to administer 'as-required' medication and little in the literature to inform practice. Our aim was to understand the patient experience of receiving these medications in the in-patient setting of a hospice. METHODS: A survey of hospice patients who had been on the ward at least seven days was conducted over a fifteen-week period looking at current practice, the patient experience of requesting medication and how long it took to be administered. RESULTS: Thirty-one responses were obtained. Patients made their requests in a variety of ways but 33% did not use their call bell. When looking at their most recent 'as-required' medication request, 87% of patients estimated that they received it within ten minutes. When considering their longest wait, 16% of patients reported waiting longer than twenty minutes. CONCLUSION: This survey highlights the importance of there being a variety of ways for patients to request 'as-required' medication and staff being proactive with patients to facilitate these requests. Patients perceive nursing staff to be busy and do not want to bother them. Although usually patients get their medication within ten minutes, patients can be waiting more than twenty minutes. There is a need for national standards on time to administer as-required medication within a healthcare setting and a need for more data to inform such a standard.


Subject(s)
Hospice Care , Hospices , Humans , Palliative Care , Patient Outcome Assessment , Surveys and Questionnaires
10.
Protein Sci ; 30(1): 136-150, 2021 01.
Article in English | MEDLINE | ID: mdl-33030237

ABSTRACT

Leginon is a system for automated data acquisition from a transmission electron microscope. Here we provide an updated summary of the overall Leginon architecture and an update of the current state of the package. We also highlight a few recent developments to provide some concrete examples and use cases.


Subject(s)
Microscopy, Electron, Transmission , Software
11.
Front Mol Biosci ; 7: 179, 2020.
Article in English | MEDLINE | ID: mdl-32850967

ABSTRACT

MicroED has recently emerged as a powerful method for the analysis of biological structures at atomic resolution. This technique has been largely limited to protein nanocrystals which grow either as needles or plates measuring only a few hundred nanometers in thickness. Furthermore, traditional microED data processing uses established X-ray crystallography software that is not optimized for handling compound effects that are unique to electron diffraction data. Here, we present an integrated workflow for microED, from sample preparation by cryo-focused ion beam milling, through data collection with a standard Ceta-D detector, to data processing using the DIALS software suite, thus enabling routine atomic structure determination of protein crystals of any size and shape using microED. We demonstrate the effectiveness of the workflow by determining the structure of proteinase K to 2.0 Å resolution and show the advantage of using protein crystal lamellae over nanocrystals.

12.
Acta Crystallogr D Struct Biol ; 76(Pt 4): 385-399, 2020 Apr 01.
Article in English | MEDLINE | ID: mdl-32254063

ABSTRACT

In processing X-ray diffraction data, the intensities obtained from integration of the diffraction images must be corrected for experimental effects in order to place all intensities on a common scale both within and between data collections. Scaling corrects for effects such as changes in sample illumination, absorption and, to some extent, global radiation damage that cause the measured intensities of symmetry-equivalent observations to differ throughout a data set. This necessarily requires a prior evaluation of the point-group symmetry of the crystal. This paper describes and evaluates the scaling algorithms implemented within the DIALS data-processing package and demonstrates the effectiveness and key features of the implementation on example macromolecular crystallographic rotation data. In particular, the scaling algorithms enable new workflows for the scaling of multi-crystal or multi-sweep data sets, providing the analysis required to support current trends towards collecting data from ever-smaller samples. In addition, the implementation of a free-set validation method is discussed, which allows the quantification of the suitability of scaling-model and algorithm choices.


Subject(s)
Algorithms , Crystallography, X-Ray , Software , X-Ray Diffraction , Macromolecular Substances
13.
IUCrJ ; 7(Pt 2): 342-354, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-32148861

ABSTRACT

This study describes a method to estimate the likelihood of success in determining a macromolecular structure by X-ray crystallography and experimental single-wavelength anomalous dispersion (SAD) or multiple-wavelength anomalous dispersion (MAD) phasing based on initial data-processing statistics and sample crystal properties. Such a predictive tool can rapidly assess the usefulness of data and guide the collection of an optimal data set. The increase in data rates from modern macromolecular crystallography beamlines, together with a demand from users for real-time feedback, has led to pressure on computational resources and a need for smarter data handling. Statistical and machine-learning methods have been applied to construct a classifier that displays 95% accuracy for training and testing data sets compiled from 440 solved structures. Applying this classifier to new data achieved 79% accuracy. These scores already provide clear guidance as to the effective use of computing resources and offer a starting point for a personalized data-collection assistant.

14.
Annu Rev Biochem ; 89: 103-133, 2020 06 20.
Article in English | MEDLINE | ID: mdl-32176524

ABSTRACT

Cells confront DNA damage in every cell cycle. Among the most deleterious types of DNA damage are DNA double-strand breaks (DSBs), which can cause cell lethality if unrepaired or cancers if improperly repaired. In response to DNA DSBs, cells activate a complex DNA damage checkpoint (DDC) response that arrests the cell cycle, reprograms gene expression, and mobilizes DNA repair factors to prevent the inheritance of unrepaired and broken chromosomes. Here we examine the DDC, induced by DNA DSBs, in the budding yeast model system and in mammals.


Subject(s)
Cell Cycle Checkpoints/genetics , DNA End-Joining Repair , DNA/genetics , Recombinational DNA Repair , Saccharomyces cerevisiae Proteins/genetics , Saccharomyces cerevisiae/genetics , Animals , Ataxia Telangiectasia Mutated Proteins/chemistry , Ataxia Telangiectasia Mutated Proteins/genetics , Ataxia Telangiectasia Mutated Proteins/metabolism , Checkpoint Kinase 1/genetics , Checkpoint Kinase 1/metabolism , Checkpoint Kinase 2/genetics , Checkpoint Kinase 2/metabolism , DNA/chemistry , DNA/metabolism , DNA Breaks, Double-Stranded , Humans , Models, Molecular , Phosphatidylinositol 3-Kinases/genetics , Phosphatidylinositol 3-Kinases/metabolism , Protein Structure, Secondary , Saccharomyces cerevisiae/metabolism , Saccharomyces cerevisiae Proteins/metabolism , Tumor Suppressor Protein p53/genetics , Tumor Suppressor Protein p53/metabolism
15.
PLoS Genet ; 15(3): e1008001, 2019 03.
Article in English | MEDLINE | ID: mdl-30822309

ABSTRACT

We have used two different live-cell fluorescent protein markers to monitor the formation and localization of double-strand breaks (DSBs) in budding yeast. Using GFP derivatives of the Rad51 recombination protein or the Ddc2 checkpoint protein, we find that cells with three site-specific DSBs, on different chromosomes, usually display 2 or 3 foci that may coalesce and dissociate. This motion is independent of Rad52 and microtubules. Rad51-GFP, by itself, is unable to repair DSBs by homologous recombination in mitotic cells, but is able to form foci and allow repair when heterozygous with a wild type Rad51 protein. The kinetics of formation and disappearance of a Rad51-GFP focus parallels the completion of site-specific DSB repair. However, Rad51-GFP is proficient during meiosis when homozygous, similar to rad51 "site II" mutants that can bind single-stranded DNA but not complete strand exchange. Rad52-RFP and Rad51-GFP co-localize to the same DSB, but a significant minority of foci have Rad51-GFP without visible Rad52-RFP. We conclude that co-localization of foci in cells with 3 DSBs does not represent formation of a homologous recombination "repair center," as the same distribution of Ddc2-GFP foci was found in the absence of the Rad52 protein.


Subject(s)
Adaptor Proteins, Signal Transducing/genetics , Cell Cycle Proteins/genetics , DNA Breaks, Double-Stranded , Rad51 Recombinase/genetics , Rad52 DNA Repair and Recombination Protein/genetics , Saccharomyces cerevisiae Proteins/genetics , DNA Damage/genetics , DNA-Binding Proteins/genetics , Green Fluorescent Proteins/genetics , Homologous Recombination/genetics , Kinetics , Meiosis/genetics , Saccharomyces cerevisiae/genetics
16.
Acta Crystallogr D Struct Biol ; 74(Pt 9): 877-894, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-30198898

ABSTRACT

The DIALS diffraction-modeling software package has been applied to serial crystallography data. Diffraction modeling is an exercise in determining the experimental parameters, such as incident beam wavelength, crystal unit cell and orientation, and detector geometry, that are most consistent with the observed positions of Bragg spots. These parameters can be refined by nonlinear least-squares fitting. In previous work, it has been challenging to refine both the positions of the sensors (metrology) on multipanel imaging detectors such as the CSPAD and the orientations of all of the crystals studied. Since the optimal models for metrology and crystal orientation are interdependent, alternate cycles of panel refinement and crystal refinement have been required. To simplify the process, a sparse linear algebra technique for solving the normal equations was implemented, allowing the detector panels to be refined simultaneously against the diffraction from thousands of crystals with excellent computational performance. Separately, it is shown how to refine the metrology of a second CSPAD detector, positioned at a distance of 2.5 m from the crystal, used for recording low-angle reflections. With the ability to jointly refine the detector position against the ensemble of all crystals used for structure determination, it is shown that ensemble refinement greatly reduces the apparent nonisomorphism that is often observed in the unit-cell distributions from still-shot serial crystallography. In addition, it is shown that batching the images by timestamp and re-refining the detector position can realistically model small, time-dependent variations in detector position relative to the sample, and thereby improve the integrated structure-factor intensity signal and heavy-atom anomalous peak heights.


Subject(s)
Bacillus/enzymology , Radiographic Image Interpretation, Computer-Assisted/methods , Software , Thermolysin/chemistry , X-Ray Diffraction , Algorithms , Bacillus/classification , Crystallography, X-Ray , Humans , Radiographic Image Interpretation, Computer-Assisted/instrumentation
17.
Acta Crystallogr D Struct Biol ; 74(Pt 6): 506-518, 2018 06 01.
Article in English | MEDLINE | ID: mdl-29872002

ABSTRACT

Electron diffraction is a relatively novel alternative to X-ray crystallography for the structure determination of macromolecules from three-dimensional nanometre-sized crystals. The continuous-rotation method of data collection has been adapted for the electron microscope. However, there are important differences in geometry that must be considered for successful data integration. The wavelength of electrons in a TEM is typically around 40 times shorter than that of X-rays, implying a nearly flat Ewald sphere, and consequently low diffraction angles and a high effective sample-to-detector distance. Nevertheless, the DIALS software package can, with specific adaptations, successfully process continuous-rotation electron diffraction data. Pathologies encountered specifically in electron diffraction make data integration more challenging. Errors can arise from instrumentation, such as beam drift or distorted diffraction patterns from lens imperfections. The diffraction geometry brings additional challenges such as strong correlation between lattice parameters and detector distance. These issues are compounded if calibration is incomplete, leading to uncertainty in experimental geometry, such as the effective detector distance and the rotation rate or direction. Dynamic scattering, absorption, radiation damage and incomplete wedges of data are additional factors that complicate data processing. Here, recent features of DIALS as adapted to electron diffraction processing are shown, including diagnostics for problematic diffraction geometry refinement, refinement of a smoothly varying beam model and corrections for distorted diffraction images. These novel features, combined with the existing tools in DIALS, make data integration and refinement feasible for electron crystallography, even in difficult cases.


Subject(s)
Electronic Data Processing/methods , Microscopy, Electron, Transmission/methods , Software , Crystallography/methods , Data Accuracy , Muramidase/chemistry , Proteins/chemistry
18.
Acta Crystallogr D Struct Biol ; 74(Pt 2): 68-84, 2018 02 01.
Article in English | MEDLINE | ID: mdl-29533233

ABSTRACT

The CCP4 (Collaborative Computational Project, Number 4) software suite for macromolecular structure determination by X-ray crystallography groups brings together many programs and libraries that, by means of well established conventions, interoperate effectively without adhering to strict design guidelines. Because of this inherent flexibility, users are often presented with diverse, even divergent, choices for solving every type of problem. Recently, CCP4 introduced CCP4i2, a modern graphical interface designed to help structural biologists to navigate the process of structure determination, with an emphasis on pipelining and the streamlined presentation of results. In addition, CCP4i2 provides a framework for writing structure-solution scripts that can be built up incrementally to create increasingly automatic procedures.


Subject(s)
Computer Graphics , Crystallography, X-Ray/methods , Software , User-Computer Interface , Crystallography, X-Ray/instrumentation , Macromolecular Substances/chemistry , Molecular Structure , Proteins/chemistry
19.
Acta Crystallogr D Struct Biol ; 74(Pt 2): 85-97, 2018 02 01.
Article in English | MEDLINE | ID: mdl-29533234

ABSTRACT

The DIALS project is a collaboration between Diamond Light Source, Lawrence Berkeley National Laboratory and CCP4 to develop a new software suite for the analysis of crystallographic X-ray diffraction data, initially encompassing spot finding, indexing, refinement and integration. The design, core algorithms and structure of the software are introduced, alongside results from the analysis of data from biological and chemical crystallography experiments.


Subject(s)
Algorithms , Crystallography, X-Ray/methods , Electronic Data Processing/methods , Software , Bacterial Proteins/chemistry , Radiographic Image Interpretation, Computer-Assisted/methods , Repressor Proteins/chemistry , Thermolysin/chemistry
20.
Proc Natl Acad Sci U S A ; 115(9): E2040-E2047, 2018 02 27.
Article in English | MEDLINE | ID: mdl-29440496

ABSTRACT

Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.


Subject(s)
CRISPR-Cas Systems , Chromosomes/ultrastructure , DNA Breaks, Double-Stranded , INDEL Mutation , RNA, Guide, Kinetoplastida , Saccharomycetales/genetics , DNA End-Joining Repair , DNA Ligase ATP/metabolism , DNA Repair , DNA-Binding Proteins/metabolism , Dimerization , Endonucleases/metabolism , Gene Deletion , Ku Autoantigen , Plasmids/metabolism , Promoter Regions, Genetic , Sequence Analysis, DNA
SELECTION OF CITATIONS
SEARCH DETAIL
...