Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Sci Rep ; 14(1): 11130, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38750100

ABSTRACT

CMR at 3.0T in the presence of active cardiac implants remains a challenge due to susceptibility artifacts. Beyond a signal void that cancels image information, magnetic field inhomogeneities may cause distorted appearances of anatomical structures. Understanding influencing factors and the extent of distortion are a first step towards optimizing the image quality of CMR with active implants at 3.0T. All measurements were obtained at a clinical 3.0T scanner. An in-house designed phantom with a 3D cartesian grid of water filled spheres was used to analyze the distortion caused by four representative active cardiac devices (cardiac loop recorder, pacemaker, 2 ICDs). For imaging a gradient echo (3D-TFE) sequence and a turbo spin echo (2D-TSE) sequence were used. The work defines metrics to quantify the different features of distortion such as changes in size, location and signal intensity. It introduces a specialized segmentation technique based on a reaction-diffusion-equation. The distortion features are dependent on the amount of magnetic material in the active implants and showed a significant increase when measured with the 3D TFE compared to the 2D TSE. This work presents a quantitative approach for the evaluation of image distortion at 3.0T caused by active cardiac implants and serves as foundation for both further optimization of sequences and devices but also for planning of imaging procedures.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Imaging , Phantoms, Imaging , Humans , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Artifacts , Pacemaker, Artificial
2.
Front Cardiovasc Med ; 10: 1200833, 2023.
Article in English | MEDLINE | ID: mdl-37692049

ABSTRACT

Background: Cardiac magnetic resonance (CMR) imaging allows for multiparametric assessment of healthy pulmonary artery (PA) hemodynamics. Gender- and aging-associated PA stiffness and pressure alterations have remained clinically unestablished, however may demonstrate epidemiological differences in disease development. The aim of this study is to evaluate the role of CMR as a surrogate for catheter examinations by providing a comprehensive CMR assessment of sex- and age-related reference values for PA stiffness, flow, and pressure. Methods and Results: PA hemodynamics were studied between gender and age groups (>/<50 years) using phase-contrast CMR. Corresponding correlation analyses were performed. 179 healthy volunteers with a median age of 32.6 years (range 11.3-68.2) were examined. Males demonstrated increased PA compliance (median [interquartile range] or mean ± standard deviation) (20.8 mm2/mmHg [16.6; 25.8] vs. 19.2 ± 7.1 mm2/mmHg; P < 0.033), higher pulse wave velocity (2.00 m/s [1.35; 2.87] vs. 1.73 m/s [1.19; 2.34]; P = 0.018) and a reduced full width half maximum (FWHM) (219 ± 22 ms vs. 235 ± 23 ms; P < 0.001) than females. Mean, systolic, diastolic PA pressure and pulmonary proportional pulse pressure were significantly elevated for males compared to females (P < 0.001). Older subjects (>50 years) exhibited reduced PA elasticity (41.7% [31.0; 52.9] vs. 66.4% [47.7; 83.0]; P < 0.001), reduced PA compliance (15.4 mm2/mmHg [12.3; 20.7] vs. 21.3 ± 6.8 mm2/mmHg; P < 0.001), higher pulse wave velocity (2.59 m/s [1.57; 3.59] vs. 1.76 m/s [1.24; 2.34]; P < 0.001) and a reduced FWHM (218 ± 29 ms vs. 231 ± 21 ms; P < 0.001) than younger subjects. Conclusions: Velocity-time profiles are dependent on age and gender. PA stiffness indices deteriorate with age. CMR has potential to serve as a surrogate for right heart catheterization.

3.
Radiology ; 308(3): e230427, 2023 09.
Article in English | MEDLINE | ID: mdl-37750774

ABSTRACT

Background Deep learning (DL) reconstructions can enhance image quality while decreasing MRI acquisition time. However, DL reconstruction methods combined with compressed sensing for prostate MRI have not been well studied. Purpose To use an industry-developed DL algorithm to reconstruct low-resolution T2-weighted turbo spin-echo (TSE) prostate MRI scans and compare these with standard sequences. Materials and Methods In this prospective study, participants with suspected prostate cancer underwent prostate MRI with a Cartesian standard-resolution T2-weighted TSE sequence (T2C) and non-Cartesian standard-resolution T2-weighted TSE sequence (T2NC) between August and November 2022. Additionally, a low-resolution Cartesian DL-reconstructed T2-weighted TSE sequence (T2DL) with compressed sensing DL denoising and resolution upscaling reconstruction was acquired. Image sharpness was assessed qualitatively by two readers using a five-point Likert scale (from 1 = nondiagnostic to 5 = excellent) and quantitatively by calculating edge rise distance. The Friedman test and one-way analysis of variance with post hoc Bonferroni and Tukey tests, respectively, were used for group comparisons. Prostate Imaging Reporting and Data System (PI-RADS) score agreement between sequences was compared by using Cohen κ. Results This study included 109 male participants (mean age, 68 years ± 8 [SD]). Acquisition time of T2DL was 36% and 29% lower compared with that of T2C and T2NC (mean duration, 164 seconds ± 20 vs 257 seconds ± 32 and 230 seconds ± 28; P < .001 for both). T2DL showed improved image sharpness compared with standard sequences using both qualitative (median score, 5 [IQR, 4-5] vs 4 [IQR, 3-4] for T2C and 4 [IQR, 3-4] for T2NC; P < .001 for both) and quantitative (mean edge rise distance, 0.75 mm ± 0.39 vs 1.15 mm ± 0.68 for T2C and 0.98 mm ± 0.65 for T2NC; P < .001 and P = .01) methods. PI-RADS score agreement between T2NC and T2DL was excellent (κ range, 0.92-0.94 [95% CI: 0.87, 0.98]). Conclusion DL reconstruction of low-resolution T2-weighted TSE sequences enabled accelerated acquisition times and improved image quality compared with standard acquisitions while showing excellent agreement with conventional sequences for PI-RADS ratings. Clinical trial registration no. NCT05820113 © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Turkbey in this issue.


Subject(s)
Deep Learning , Prostatic Neoplasms , Humans , Male , Aged , Magnetic Resonance Imaging , Prospective Studies , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery
4.
Eur J Radiol ; 163: 110831, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37059004

ABSTRACT

PURPOSE: To compare standard breath-hold (BH) cine imaging to a radial pseudo-golden-angle free-breathing (FB) technique in congenital heart disease (CHD). METHODS: In this prospective study, short-axis and 4-chamber BH and FB cardiac MRI sequences of 25 participants with CHD acquired at 1.5 Tesla, were quantitatively compared regarding ventricular volumes, function, interventricular septum thickness (IVSD), apparent signal to noise ratio (aSNR), and estimated contrast to noise ratio (eCNR). For qualitative comparison, three image quality criteria (contrast, endocardial edge definition, and artefacts) were rated on a 5-point Likert scale (5: excellent, 1: non-diagnostic). Paired t-Test was used for group comparisons, Bland-Altman analysis for agreement between techniques. Inter-reader agreement was compared using intraclass correlation coefficient. RESULTS: IVSD (BH 7.4 ± 2.1 mm vs FB 7.4 ± 1.9 mm, p =.71), biventricular ejection fraction (left ventricle [LV]: 56.4 ± 10.8% vs 56.1 ± 9.3%, p =.83; right ventricle [RV]: 49.5 ± 8.6% vs 49.7 ± 10.1%, p =.83), and biventricular end diastolic volume (LV: 176.3 ± 63.9 ml vs 173.9 ± 64.9 ml, p =.90; RV: 185.4 ± 63.8 ml vs 189.6 ± 66.6 ml, p =.34) were comparable. Mean measurement time for FB short-axis sequences was 8.1 ± 1.3 compared to 4.4 ± 1.3 min for BH (p <.001). Subjective image quality between sequences was deemed comparable, (4.6 ± 0.6 vs 4.5 ± 0.6, p =.26, for 4-chamber views) with a significant difference regarding short-axis views (4.9 ± 0.3 vs 4.5 ± 0.6, p =.008). aSNR was similar (BH 25.8 ± 11.2 vs FB 22.2 ± 9.5, p =.24), while eCNR was higher for BH (89.1 ± 36.1 vs 68.5 ± 32.1, p =.03). CONCLUSION: FB sequences yielded comparable results to BH regarding image quality, biventricular volumetry, and function, though measurement times were longer. The FB sequence described might be clinically valuable when BHs are insufficiently performed.


Subject(s)
Heart Defects, Congenital , Respiration , Humans , Prospective Studies , Magnetic Resonance Imaging/methods , Heart Defects, Congenital/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Breath Holding , Reproducibility of Results
5.
Invest Radiol ; 58(3): 209-215, 2023 03 01.
Article in English | MEDLINE | ID: mdl-36070533

ABSTRACT

OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time. MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates. RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants. CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.


Subject(s)
Magnetic Resonance Imaging , Prostatic Neoplasms , Humans , Male , Middle Aged , Aged , Magnetic Resonance Imaging/methods , Prostate/diagnostic imaging , Reproducibility of Results , Prostatic Neoplasms/diagnostic imaging , Signal-To-Noise Ratio , Artifacts
6.
J Cardiovasc Magn Reson ; 24(1): 55, 2022 11 17.
Article in English | MEDLINE | ID: mdl-36384752

ABSTRACT

BACKGROUND: To evaluate the great vessels in young children with complex congenital heart disease (CHD) using non-contrast cardiovascular magnetic resonance angiography (CMRA) based on three-dimensional relaxation-enhanced angiography without contrast (REACT) in comparison to contrast-enhanced steady-state CMRA. METHODS: In this retrospective study from April to July 2021, respiratory- and electrocardiogram-gated native REACT CMRA was compared to contrast-enhanced single-phase steady-state CMRA in children with CHD who underwent CMRA at 3T under deep sedation. Vascular assessment included image quality (1 = non-diagnostic, 5 = excellent), vessel diameter, and diagnostic findings. For statistical analysis, paired t-test, Pearson correlation, Bland-Altman analysis, Wilcoxon test, and intraclass correlation coefficients (ICC) were applied. RESULTS: Thirty-six young children with complex CHD (median 4 years, interquartile range, 2-5; 20 males) were included. Native REACT CMRA was obtained successfully in all patients (mean scan time: 4:22 ± 1:44 min). For all vessels assessed, diameters correlated strongly between both methods (Pearson r = 0.99; bias = 0.04 ± 0.61 mm) with high interobserver reproducibility (ICC: 0.99 for both CMRAs). Native REACT CMRA demonstrated comparable overall image quality to contrast-enhanced CMRA (3.9 ± 1.0 vs. 3.8 ± 0.9, P = 0.018). With REACT CMRA, better image quality was obtained at the ascending aorta (4.8 ± 0.5 vs. 4.3 ± 0.8, P < 0.001), coronary roots (e.g., left: 4.1 ± 1.0 vs. 3.3 ± 1.1, P = 0.001), and inferior vena cava (4.6 ± 0.5 vs. 3.2 ± 0.8, P < 0.001). In all patients, additional vascular findings were assessed equally with native REACT CMRA and the contrast-enhanced reference standard (n = 6). CONCLUSION: In young children with complex CHD, REACT CMRA can provide gadolinium-free high image quality, accurate vascular measurements, and equivalent diagnostic quality compared to standard contrast-enhanced CMRA.


Subject(s)
Heart Defects, Congenital , Magnetic Resonance Angiography , Male , Humans , Child , Child, Preschool , Magnetic Resonance Angiography/methods , Retrospective Studies , Reproducibility of Results , Contrast Media , Predictive Value of Tests , Heart Defects, Congenital/diagnostic imaging
7.
Sci Rep ; 12(1): 6285, 2022 04 15.
Article in English | MEDLINE | ID: mdl-35428775

ABSTRACT

Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0 T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0 T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence, multi-slice 2D turbo spin echo sequence). Reference sequences according to the American Society for Testing and Materials (ASTM) were additionally applied. Four representative active cardiac devices and a generic setup were analyzed regarding volume and shape of the signal void. For analysis, a threshold operation was applied to the grey value profile of each data set. The presented approach allows the evaluation of the signal void and shape even for larger implants such as ICDs. The void shape is influenced by the orientation of the B0-field and by the chosen sequence type. The distribution of ferromagnetic material within the implants also matters. The void volume depends both on the device itself, and on the sequence type. Disturbances in the B0 and B1 fields exceed the visual signal void. This work presents a reproducible and highly defined approach to characterize both signal void artifacts at 3.0 T and their influencing factors.


Subject(s)
Artifacts , Prostheses and Implants , Magnetic Resonance Imaging , Magnets , Phantoms, Imaging
8.
Anaesthesist ; 70(5): 383-391, 2021 05.
Article in German | MEDLINE | ID: mdl-33244640

ABSTRACT

BACKGROUND: Teaching of resuscitation measures is not mandatory in all schools in Germany. It is currently limited to individual, partly mandatory projects despite a low bystander resuscitation rate. For this reason, the Ministry for Schools and Education of North Rhine-Westphalia initiated the project "Bystander resuscitation at schools in NRW" in March 2017. OBJECTIVE: The aim of this work was to evaluate this project. MATERIAL AND METHODS: All secondary schools in North Rhine-Westphalia were invited to participate in the project. Medical partners from each administrative district took part, who carried out resuscitation training with existing concepts for teacher or student training. After a 3-year period, the evaluation was carried out using standardized questionnaires for school headmasters, teachers and students. RESULTS: In total, more than 40,000 pupils from 249 schools in NRW could be trained in resuscitation within the project with 6 different concepts. Of the students 85% answered the questions regarding resuscitation correctly and overall felt safe in resuscitation measures. The one-off investment requirement for all schools is roughly 4-6.5 million € and around 340,000 € in each budget year. CONCLUSION: A legal constitution and funding are necessary for a nationwide introduction of resuscitation in schools. All established concepts are effective, therefore each school can use them exactly according to their needs, optimally in a stepped form. Training for teachers should focus on resuscitation.


Subject(s)
Cardiopulmonary Resuscitation , Germany/epidemiology , Humans , Schools , Students , Surveys and Questionnaires
9.
J Phys Chem Lett ; 10(11): 2971-2977, 2019 Jun 06.
Article in English | MEDLINE | ID: mdl-31091105

ABSTRACT

Lead halide perovskites, which are causing a paradigm shift in photovoltaics, exhibit an atypical temperature dependence of the fundamental gap: it decreases in energy with decreasing temperature. Reports ascribe such a behavior to a strong electron-phonon renormalization of the gap, neglecting contributions from thermal expansion. However, high-pressure experiments performed on the archetypal perovskite MAPbI3 (MA stands for methylammonium) yield a negative pressure coefficient for the gap of the tetragonal room-temperature phase, which speaks against the assumption of negligible thermal expansion effects. Here we show that for MAPbI3 the temperature-induced gap renormalization due to electron-phonon interaction can only account for about 40% of the total energy shift, thus implying thermal expansion to be more if not as important as electron-phonon coupling. Furthermore, this result possesses general validity, holding also for the tetragonal or cubic phase, stable at ambient conditions, of most halide perovskite counterparts.

10.
Nanomedicine (Lond) ; 11(21): 2781-2795, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27739933

ABSTRACT

AIM: The biomedical application of contrast agents based on superparamagnetic iron oxide nanoparticles is still limited because of their short intravascular half-life. The potential of red blood cells (RBCs) loaded with new ferucarbotran nanoparticles as magnetic contrast agents with longer blood retention time has been investigated. MATERIALS & METHODS: Ferucarbotran was loaded into RBCs by a procedure of hypotonic dialysis and isotonic resealing. Ferucarbotran amounts encapsulated in RBCs were determined by NMR. The survival of ferucarbotran-loaded RBCs and bulk ferucarbotran was evaluated in the mouse bloodstream. RESULTS: Blood retention time of these RBC constructs is longer (∼14 days) than the bulk ferucarbotran (∼1 h) with a slower Fe clearance from liver and spleen. CONCLUSION: Ferucarbotran-loaded RBCs could be used as potential contrasting agents for diagnostic applications in MRI/magnetic particle imaging.

11.
Phys Chem Chem Phys ; 18(39): 27051-27066, 2016 Oct 21.
Article in English | MEDLINE | ID: mdl-27346792

ABSTRACT

We present Raman and terahertz absorbance spectra of methylammonium lead halide single crystals (MAPbX3, X = I, Br, Cl) at temperatures between 80 and 370 K. These results show good agreement with density-functional-theory phonon calculations. Comparison of experimental spectra and calculated vibrational modes enables confident assignment of most of the vibrational features between 50 and 3500 cm-1. Reorientation of the methylammonium cations, unlocked in their cavities at the orthorhombic-to-tetragonal phase transition, plays a key role in shaping the vibrational spectra of the different compounds. Calculations show that these dynamic effects split Raman peaks and create more structure than predicted from the independent harmonic modes. This explains the presence of extra peaks in the experimental spectra that have been a source of confusion in earlier studies. We discuss singular features, in particular the torsional vibration of the C-N axis, which is the only molecular mode that is strongly influenced by the size of the lattice. From analysis of the spectral linewidths, we find that MAPbI3 shows exceptionally short phonon lifetimes, which can be linked to low lattice thermal conductivity. We show that optical rather than acoustic phonon scattering is likely to prevail at room temperature in these materials.

12.
Nanoscale ; 8(12): 6317-27, 2016 Mar 28.
Article in English | MEDLINE | ID: mdl-26477295

ABSTRACT

The optical constants of methylammonium lead halide single crystals CH3NH3PbX3 (X = I, Br, Cl) are interpreted with high level ab initio calculations using the relativistic quasiparticle self-consistent GW approximation (QSGW). Good agreement between the optical constants derived from QSGW and those obtained from spectroscopic ellipsometry enables the assignment of the spectral features to their respective inter-band transitions. We show that the transition from the highest valence band (VB) to the lowest conduction band (CB) is responsible for almost all the optical response of MAPbI3 between 1.2 and 5.5 eV (with minor contributions from the second highest VB and the second lowest CB). The calculations indicate that the orientation of [CH3NH3](+) cations has a significant influence on the position of the bandgap suggesting that collective orientation of the organic moieties could result in significant local variations of the optical properties. The optical constants and energy band diagram of CH3NH3PbI3 are then used to simulate the contributions from different optical transitions to a typical transient absorption spectrum (TAS).

13.
Acta Crystallogr B Struct Sci Cryst Eng Mater ; 71(Pt 6): 668-78, 2015 Dec 01.
Article in English | MEDLINE | ID: mdl-26634723

ABSTRACT

The structural chemistry of hybrid organic-inorganic lead iodide materials has become of increasing significance for energy applications since the discovery and development of perovskite solar cells based on methylammonium lead iodide. Seven new hybrid lead iodide compounds have been synthesized and structurally characterized using single-crystal X-ray diffraction. The lead iodide units in materials templated with bipyridyl, 1,2-bis(4-pyridyl)ethane, 1,2-di(4-pyridyl)ethylene and imidazole adopt one-dimensional chain structures, while crystallization from solutions containing piperazinium cations generates a salt containing isolated [PbI6](4-) octahedral anions. Templating with 4-chlorobenzylammonium lead iodide adopts the well known two-dimensional layered perovskite structure with vertex shared sheets of composition [PbI4](2-) separated by double layers of organic cations. The relationships between the various structures determined, their compositions, stability and hydrogen bonding between the protonated amine and the iodide ions of the PbI6 octahedra are described.

14.
Chem Commun (Camb) ; 51(20): 4180-4183, 2015 Mar 11.
Article in English | MEDLINE | ID: mdl-25634426

ABSTRACT

The methylammonium cation in [CH3NH3]PbI3 demonstrates increasing positional disorder on heating from 100 K to 352 K. In the tetragonal phase, stable between 165 K and 327 K, the cation is disordered over four sites directed toward the faces of the distorted cubic [PbI3](-) framework and migrates towards the cavity centre with increasing temperature.

15.
PLoS One ; 7(10): e43402, 2012.
Article in English | MEDLINE | ID: mdl-23082108

ABSTRACT

INTRODUCTION: Developments in telemedicine have not produced any relevant benefits for orthopedics and trauma surgery to date. For the present project study, several parameters were examined during assessment of x-ray images, which had been photographed and transmitted via cell phone. MATERIALS AND METHODS: A total of 100 x-ray images of various body regions were photographed with a Nokia cell phone and transmitted via email or MMS. Next, the transmitted photographs were reviewed on a laptop computer by five medical specialists and assessed regarding quality and diagnosis. RESULTS: Due to their poor quality, the transmitted MMS images could not be evaluated and this path of transmission was therefore excluded. Mean size of transmitted x-ray email images was 394 kB (range: 265-590 kB, SD ± 59), average transmission time was 3.29 min ± 8 (CI 95%: 1.7-4.9). Applying a score from 1-10 (very poor - excellent), mean image quality was 5.8. In 83.2 ± 4% (mean value ± SD) of cases (median 82; 80-89%), there was agreement between final diagnosis and assessment by the five medical experts who had received the images. However, there was a markedly low concurrence ratio in the thoracic area and in pediatric injuries. DISCUSSION: While the rate of accurate diagnosis and indication for surgery was high with a concurrence ratio of 83%, considerable differences existed between the assessed regions, with lowest values for thoracic images. Teleradiology is a cost-effective, rapid method which can be applied wherever wireless cell phone reception is available. In our opinion, this method is in principle suitable for clinical use, enabling the physician on duty to agree on appropriate measures with colleagues located elsewhere via x-ray image transmission on a cell phone.


Subject(s)
Cell Phone , Photography/instrumentation , Photography/standards , Teleradiology/methods , Teleradiology/standards , Child , Humans , Reproducibility of Results , X-Rays
16.
Int Orthop ; 36(7): 1463-9, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22358174

ABSTRACT

PURPOSE: Medial femoral neck fractures are common, and closed reduction and internal fixation by three cannulated screws is an accepted method for the surgical treatment. Computer navigation for screw placement may reduce fluoroscopy time, the number of guidewire passes and optimise screw placement. METHODS: In the context of a sawbone study, a computer-assisted planning and navigation system based on 3D-imaging for guidewire placement in the femoral neck was tested to improve screw placement. Three screws were inserted into 12, intact, femoral sawbones using the conventional technique and into 12, intact, femoral sawbones guided by the computer-based navigation system. Guidewire and subsequent screw placement in the femoral neck were evaluated. RESULTS: Use of the navigation system resulted in a significant reduction of the number of drilling attempts (p≤0.05) and achieved optimised accuracy of implant placement by attaining significantly better screw parallelism (p≤0.05) and significantly enlarged neck-width coverage by the three screws (p≤0.0001). Computer assistance significantly increased the number of fluoroscopic images (p≤0.001) and the operation time (p≤0.0001). CONCLUSIONS: Three-dimensional computer-assisted navigation improves accuracy of cannulated screw placement in femoral neck while increasing the number of fluoroscopic images and operation time. Additional studies including fractured sawbones and cadaver models with the goal of reducing operation time are indispensable before introduction of this navigation system into clinical practice.


Subject(s)
Bone Screws , Fracture Fixation, Internal/methods , Hip Joint/surgery , Materials Testing , Prosthesis Implantation/methods , Surgery, Computer-Assisted/methods , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/instrumentation , Models, Biological , Pilot Projects
17.
Eur J Radiol ; 81(6): 1366-70, 2012 Jun.
Article in English | MEDLINE | ID: mdl-21458188

ABSTRACT

OBJECTIVE: To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures. MATERIALS AND METHODS: The study was approved by the responsible justice department and the ethics committee. The contrast of water, fat, and muscle was measured using regions of interest (ROI) in the orbit of 41 human corpses to assess how body temperature (range 2.1-39.8 °C) relates to image contrast of T1-weighted (T1W) and T2-weighted (T2W) sequences on PMMR. Regressions were calculated using the method of least squares. Three readers judged visible changes of image contrast subjectively by consensus. RESULTS: There was a positive relationship between temperature and contrast on T1-weighted (T1W) images and between temperature and the contrast of fat/muscle on T2-weighted (T2W) images. There was a negative relationship between temperature and the contrast of water/fat and water/muscle on T2W images. Subjectively, the influence of temperature became visible below 20 °C on T2W images, and below 10 °C on T1W images. CONCLUSION: Image contrast on PMMR depends on the temperature of a corpse. Radiologists involved in post mortem imaging must be aware of temperature-related changes in MR image contrast. To preserve technical quality, scanning corpses below 10 °C should be avoided.


Subject(s)
Body Temperature , Magnetic Resonance Imaging/methods , Postmortem Changes , Adolescent , Adult , Aged , Aged, 80 and over , Cadaver , Child , Female , Humans , Least-Squares Analysis , Linear Models , Male , Middle Aged , Whole Body Imaging
18.
Eur J Radiol ; 81(9): 2208-14, 2012 Sep.
Article in English | MEDLINE | ID: mdl-21724352

ABSTRACT

OBJECTIVES: Minimally invasive or virtual autopsies are being advocated as alternative to traditional autopsy, but have limited abilities to detect coronary artery disease. It was the objective of this study to assess if the occurrence of chemical shift artifacts (CSA) along the coronary arteries on non-contrast, post-mortem cardiac MR may be used to investigate coronary artery disease. METHODS: We retrospectively compared autopsy and CT findings of 30 cases with significant (≥75%), insignificant (<75%), or absent coronary artery stenosis to post-mortem cardiac MR findings. The chi-square test was used to investigate if the occurrence of CSA depends on the presence or absence of stenosis. Sensitivity, specificity and predictive values were calculated for each finding. RESULTS: CSA indicates the absence of (significant) stenosis (p<0.001). The occurrence of paired dark bands in lieu of CSA on post-mortem cardiac MR suggests (significant) coronary arteries stenosis (p<0.001). Both findings have a high specificity but low sensitivity. CONCLUSIONS: CSA is a marker of vessel patency. The presence of paired dark bands indicates stenosis. These criteria improve the ability of minimally invasive or virtual autopsy to detect coronary artery disease related deaths.


Subject(s)
Coronary Artery Disease/pathology , Magnetic Resonance Angiography/methods , Adolescent , Adult , Aged , Aged, 80 and over , Autopsy , Cadaver , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
19.
Acta Orthop ; 82(4): 489-93, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21657968

ABSTRACT

BACKGROUND: Despite the fact that C-reactive protein (CRP) levels and white blood cell (WBC) count are routine blood chemistry parameters for the early assessment of wound infection after surgical procedures, little is known about the natural history of their serum values after major and minimally invasive spinal procedures. METHODS: Pre- and postoperative CRP serum levels and WBC count in 347 patients were retrospectively assessed after complication-free, single-level open posterior lumbar interlaminar fusion (PLIF) (n = 150) for disc degeneration and spinal stenosis and endoscopically assisted lumbar discectomy (n = 197) for herniated lumbar disc. Confounding variables such as overweight, ASA classification, arterial hypertension, diabetes mellitus, and perioperative antibiotics were recorded to evaluate their influence on the kinetics of CRP values and WBC count postoperatively. RESULTS: In both procedures, CRP peaked 2-3 days after surgery. The maximum CRP level was significantly higher after fusion: mean 127 (SD 57) (p < 0.001). A rapid fall in CRP within 4-6 days was observed for both groups, with almost normal values being reached after 14 days. Only BMI > 25 and long duration of surgery were associated with higher peak CRP values. WBC count did not show a typical and therefore interpretable profile. CONCLUSION: CRP is a predictable and responsive serum parameter in postoperative monitoring of inflammatory responses in patients undergoing spine surgery, whereas WBC kinetics is unspecific. We suggest that CRP could be measured on the day before surgery, on day 2 or 3 after surgery, and also between days 4 and 6, to aid in early detection of infectious complications.


Subject(s)
C-Reactive Protein/analysis , Diskectomy, Percutaneous , Leukocyte Count , Lumbar Vertebrae/surgery , Spinal Fusion , Adult , Aged , Anti-Bacterial Agents/administration & dosage , Diskectomy, Percutaneous/adverse effects , Female , Humans , Intervertebral Disc Degeneration/surgery , Male , Middle Aged , Postoperative Period , Predictive Value of Tests , Retrospective Studies , Spinal Fusion/adverse effects , Spinal Stenosis/surgery , Surgical Wound Infection/blood , Surgical Wound Infection/drug therapy , Surgical Wound Infection/prevention & control
20.
Magn Reson Med ; 62(3): 699-705, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19572387

ABSTRACT

Magnetization transfer imaging (MTI) by means of MRI exploits the mobility of water molecules in tissue and offers an alternative contrast mechanism beyond the more commonly used mechanisms based on relaxation times. A cardiac MTI method was implemented on a commercially available 1.5 T MR imager. It is based on the acquisition of two sets of cardiac-triggered cine balanced steady-state free precession (bSSFP) images with different levels of RF power deposition. Reduction of RF power was achieved by lengthening the RF excitation pulses of a cine bSSFP sequence from 0.24 ms to 1.7 ms, while keeping the flip angle constant. Normal volunteers and patients with acute myocardial infarcts were imaged in short and long axis views. Normal myocardium showed an MT ratio (MTR) of 33.0 +/- 3.3%. In acute myocardial infarct, MTR was reduced to 24.5 +/- 9.2% (P < 0.04), most likely caused by an increase in water content due to edema. The method thus allows detection of acute myocardial infarct without the administration of contrast agents.


Subject(s)
Algorithms , Gadolinium DTPA , Heart/physiopathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Myocardium/pathology , Contrast Media , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL