Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
PLoS Negl Trop Dis ; 17(10): e0011724, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37906617

ABSTRACT

BACKGROUND: Endocystectomy is a conservative surgical approach to managing cystic echinococcosis. Bile leakage is the main complication of this technique. The aim of this study was to evaluate the factors associated with bile leakage and to assess the outcomes and cost efficiency of strategies used to treat bile leakage. METHODOLOGY/PRINCIPAL FINDINGS: Patients who underwent endocystectomy between 2005 and 2020 were included. The preoperative characteristics, intra- and postoperative outcomes, hospital costs, and cost efficiency (the Diagnosis-Related Group reimbursement minus the overall cost) were evaluated prospectively. A total of eighty patients with 142 cysts were included. Postoperative complications occurred in 17 patients (21%), including 11 patients with bile leakage (type A: 1, type B: 6 and type C: 4 patients, total 13%). Bile leakage was more frequent in patients with preoperative MRI signs of cysto-biliary fistulas or intraoperative visible cysto-biliary fistulas (p = 0.03 and p = 0.04, respectively) and in patients with cysts larger than 8 cm (p = 0.03). Patients with bile leakage who underwent reoperation (type C) had significantly shorter hospital stays (9 vs. 16 days, p<0.01) and better cost efficiency than those who received radiologic or endocscopic interventions (€2,072 vs. -€2,097 p = 0.01). No mortality was observed, and recurrence was seen in two patients. CONCLUSIONS/SIGNIFICANCE: Endocystectomy is a safe and efficient technique. Preoperative and intraoperative cysto-biliary fistulas and a cyst diameter larger than 8 cm are correlated to postoperative bile leakage. Early operative management of bile leakage reduces hospital stay and improves cost efficiency compared with radiologic or endoscopic treatments.


Subject(s)
Biliary Fistula , Cysts , Echinococcosis, Hepatic , Humans , Biliary Fistula/etiology , Biliary Fistula/surgery , Biliary Fistula/diagnosis , Echinococcosis, Hepatic/surgery , Echinococcosis, Hepatic/diagnosis , Risk Factors , Endoscopy , Retrospective Studies
2.
J Cancer Res Clin Oncol ; 149(16): 14785-14796, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37589924

ABSTRACT

PURPOSE: Despite improvements in multimodal treatment of locally advanced esophagogastric adenocarcinoma, the majority of patients still relapses. The impact of structured follow-up for early detection of recurrence is unclear and controversially discussed. METHODS: Patients with locally advanced esophagogastric adenocarcinoma having received neoadjuvant/perioperative chemotherapy followed by tumor resection between 2009 and 2021, underwent a structured follow-up including three-monthly imaging during the first 2 years, followed by semiannual and annual examinations in year 3-4 and 5, respectively. Clinical outcome including pattern and time point of relapse was analyzed. RESULTS: Two hundred fifty-seven patients were included in this analysis. In 50.2% (n = 129) of patients, recurrent disease was diagnosed, with the majority (94.6%) relapsing within the first 2 years. The most common site of relapse were lymph node metastases followed by peritoneal carcinomatosis and hepatic and pulmonary metastases. 52.7% of patients presented with symptoms at the time of relapse. Cumulative risk and time point of relapse differed significantly between patient with a node-positive tumor (ypN+) after neoadjuvant treatment (high-risk group) and patients with node-negative primary tumor (ypN0) (low-risk group). High-risk patients had a significantly inferior disease-free survival (DFS) and overall survival (OS) with 11.1 and 29.0 months, respectively, whereas median DFS and OS were not reached for the low-risk group. CONCLUSIONS: The risk of relapse differs significantly between high- and low-risk patients. Only a part of relapses is associated with clinical symptoms. An individualized follow-up strategy is recommended for high- and low-risk patients considering the individual risk of relapse.


Subject(s)
Adenocarcinoma , Humans , Follow-Up Studies , Combined Modality Therapy , Adenocarcinoma/drug therapy , Disease-Free Survival , Neoadjuvant Therapy , Recurrence , Neoplasm Staging , Retrospective Studies
3.
Curr Opin Infect Dis ; 36(5): 318-325, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37578473

ABSTRACT

PURPOSE OF REVIEW: The aim of our review is to summarize specific clinical, diagnostic and treatment aspects of pulmonary cystic echinococcosis. The lung is the organ second most affected by cystic echinococcosis with approximately a quarter of cystic echinococcosis cysts. Most cysts are in the liver. Apart from the watch and wait approach for selected inactive cysts [cystic echinococcosis CE4, CE5], the well established WHO cystic echinococcosis cyst classification-based treatment of hepatic cystic echinococcosis cannot be applied to pulmonary cystic echinococcosis cysts. Some standard interventions can even be harmful when applied to pulmonary cystic echinococcosis cysts. RECENT FINDINGS: Cystic echinococcosis is one of the neglected tropical diseases (NTDs). Development of new diagnostics and treatment modalities is hampered by low investment into research and is accordingly slow. SUMMARY: Surgery is the mainstay of treatment for pulmonary cystic echinococcosis cysts. Parenchyma-sparing surgical techniques should be used whenever possible. Albendazole induces decay of the parasitic cyst membrane, opening of cystobronchial fistulas and cyst complications, which can be life threatening. It is strongly recommended to seek advice from expert centres, including differential diagnoses, treatment and a long-term management plan.


Subject(s)
Cysts , Echinococcosis, Hepatic , Echinococcosis , Humans , Echinococcosis/diagnosis , Echinococcosis, Hepatic/diagnosis , Echinococcosis, Hepatic/epidemiology , Echinococcosis, Hepatic/surgery , Albendazole/therapeutic use , Cysts/drug therapy , Lung
4.
Rofo ; 195(12): 1106-1121, 2023 12.
Article in English, German | MEDLINE | ID: mdl-37467780

ABSTRACT

BACKGROUND: Cystic (CE) and alveolar (AE) echinococcoses are zoonotic parasitoses that may pose diagnostic problems due to their relative rarity in Middle Europe. METHODS: Based on a recent literature search and the observation of casuistics from a national echinococcosis treatment center, epidemiological, radiological, and therapeutic fundamentals are presented and important differences between AE and CE are discussed. RESULTS AND CONCLUSION: AE and CE must be regarded as completely different diseases, which differ from each other in every significant aspect. This applies not only to the epidemiological background of the patients but also to the biology of the diseases and their respective imaging features. KEY POINTS: · AE and CE are very distinct from one another and must be considered separately.. · AE is endemic in Middle Europe and is known as malignant parasitosis due to its destructive growth form.. · CE is primarily seen in Middle Europe in individuals with migration background and has a rather benign character.. CITATION FORMAT: · Weber TF, Mokry T, Stojkovic M. Die Echinokokkosen - Einblicke aus Sicht der Radiologie. Fortschr Röntgenstr 2023; 195: 1106 - 1121.


Subject(s)
Echinococcosis , Humans , Echinococcosis/diagnostic imaging , Echinococcosis/drug therapy , Europe , Radiologists
5.
Br J Radiol ; 96(1145): 20220745, 2023 Apr 01.
Article in English | MEDLINE | ID: mdl-37001052

ABSTRACT

OBJECTIVE: To investigate the reproducibility of size measurements of focal bone marrow lesions (FL) in MRI in patients with monoclonal plasma cell disorders under variation of patient positioning and observer. METHODS: A data set from a prospective test-retest study was used, in which 37 patients with a total of 140 FL had undergone 2 MRI scans with identical parameters after patient repositioning. Two readers measured long and short axis diameter on the initial scan in T1 weighted, T2 weighted short tau inversion recovery and diffusion-weighted imaging sequences. The first reader additionally measured FL on the retest-scan. The Bland-Altman method was used to assess limits of agreement (LoA), and the frequencies of absolute size changes were calculated. RESULTS: In the simple test-retest experiment with one identical reader, a deviation of ≥1 mm / ≥2 mm / ≥3 mm for the long axis diameter in T1 weighted images was observed in 66% / 25% / 8% of cases. When comparing measurements of one reader on the first scan to the measurement of the other reader on the retest scan, a change of ≥1 mm / ≥3 mm / ≥5 mm for the long axis diameter in T1 weighted images was observed in 78% / 21% / 5% of cases. CONCLUSION: Small deviations in FL size are common and probably due to variation in patient positioning or inter-rater variability alone, without any actual biological change of the FL. Knowledge of the uncertainty associated with size measurements of FLs is critical for radiologists and oncologists when interpreting changes in FL size in clinical practice and in clinical trials. ADVANCES IN KNOWLEDGE: According to the MY-RADs criteria, size measurements of focal lesions in MRI are now of relevance for response assessment in patients with monoclonal plasma cell disorders.Size changes of 1 or 2 mm are frequently observed due to uncertainty of the measurement only, while the actual focal lesion has not undergone any biological change.Size changes of at least 6 mm or more in T1 weighted or T2 weighted short tau inversion recovery sequences occur in only 5% or less of cases when the focal lesion has not undergone any biological change.


Subject(s)
Bone Diseases , Multiple Myeloma , Humans , Multiple Myeloma/diagnostic imaging , Bone Marrow/diagnostic imaging , Prospective Studies , Reproducibility of Results , Retrospective Studies , Magnetic Resonance Imaging/methods
6.
Eur Radiol ; 33(8): 5557-5567, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36892642

ABSTRACT

OBJECTIVES: Quantitative computed tomography (CT) plays an increasingly important role in phenotyping airway diseases. Lung parenchyma and airway inflammation could be quantified by contrast enhancement at CT, but its investigation by multiphasic examinations is limited. We aimed to quantify lung parenchyma and airway wall attenuation in a single contrast-enhanced spectral detector CT acquisition. METHODS: For this cross-sectional retrospective study, 234 lung-healthy patients who underwent spectral CT in four different contrast phases (non-enhanced, pulmonary arterial, systemic arterial, and venous phase) were recruited. Virtual monoenergetic images were reconstructed from 40-160 keV, on which attenuations of segmented lung parenchyma and airway walls combined for 5th-10th subsegmental generations were assessed in Hounsfield Units (HU) by an in-house software. The spectral attenuation curve slope between 40 and 100 keV (λHU) was calculated. RESULTS: Mean lung density was higher at 40 keV compared to that at 100 keV in all groups (p < 0.001). λHU of lung attenuation was significantly higher in the systemic (1.7 HU/keV) and pulmonary arterial phase (1.3 HU/keV) compared to that in the venous phase (0.5 HU/keV) and non-enhanced (0.2 HU/keV) spectral CT (p < 0.001). Wall thickness and wall attenuation were higher at 40 keV compared to those at 100 keV for the pulmonary and systemic arterial phase (p ≤ 0.001). λHU for wall attenuation was significantly higher in the pulmonary arterial (1.8 HU/keV) and systemic arterial (2.0 HU/keV) compared to that in the venous (0.7 HU/keV) and non-enhanced (0.3 HU/keV) phase (p ≤ 0.002). CONCLUSIONS: Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition, and may separate arterial and venous enhancement. Further studies are warranted to analyze spectral CT for inflammatory airway diseases. KEY POINTS: • Spectral CT may quantify lung parenchyma and airway wall enhancement with a single contrast phase acquisition. • Spectral CT may separate arterial and venous enhancement of lung parenchyma and airway wall. • The contrast enhancement can be quantified by calculating the spectral attenuation curve slope from virtual monoenergetic images.


Subject(s)
Hypertension, Pulmonary , Humans , Retrospective Studies , Cross-Sectional Studies , Tomography, X-Ray Computed/methods , Software , Contrast Media/pharmacology , Signal-To-Noise Ratio , Radiographic Image Interpretation, Computer-Assisted/methods
7.
Invest Radiol ; 58(4): 273-282, 2023 04 01.
Article in English | MEDLINE | ID: mdl-36256790

ABSTRACT

OBJECTIVES: Diffusion-weighted magnetic resonance imaging (MRI) is increasingly important in patients with multiple myeloma (MM). The objective of this study was to train and test an algorithm for automatic pelvic bone marrow analysis from whole-body apparent diffusion coefficient (ADC) maps in patients with MM, which automatically segments pelvic bones and subsequently extracts objective, representative ADC measurements from each bone. MATERIALS AND METHODS: In this retrospective multicentric study, 180 MRIs from 54 patients were annotated (semi)manually and used to train an nnU-Net for automatic, individual segmentation of the right hip bone, the left hip bone, and the sacral bone. The quality of the automatic segmentation was evaluated on 15 manually segmented whole-body MRIs from 3 centers using the dice score. In 3 independent test sets from 3 centers, which comprised a total of 312 whole-body MRIs, agreement between automatically extracted mean ADC values from the nnU-Net segmentation and manual ADC measurements from 2 independent radiologists was evaluated. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. In 56 patients with newly diagnosed MM who had undergone bone marrow biopsy, ADC measurements were correlated with biopsy results using Spearman correlation. RESULTS: The ADC-nnU-Net achieved automatic segmentations with mean dice scores of 0.92, 0.93, and 0.85 for the right pelvis, the left pelvis, and the sacral bone, whereas the interrater experiment gave mean dice scores of 0.86, 0.86, and 0.77, respectively. The agreement between radiologists' manual ADC measurements and automatic ADC measurements was as follows: the bias between the first reader and the automatic approach was 49 × 10 -6 mm 2 /s, 7 × 10 -6 mm 2 /s, and -58 × 10 -6 mm 2 /s, and the bias between the second reader and the automatic approach was 12 × 10 -6 mm 2 /s, 2 × 10 -6 mm 2 /s, and -66 × 10 -6 mm 2 /s for the right pelvis, the left pelvis, and the sacral bone, respectively. The bias between reader 1 and reader 2 was 40 × 10 -6 mm 2 /s, 8 × 10 -6 mm 2 /s, and 7 × 10 -6 mm 2 /s, and the mean absolute difference between manual readers was 84 × 10 -6 mm 2 /s, 65 × 10 -6 mm 2 /s, and 75 × 10 -6 mm 2 /s. Automatically extracted ADC values significantly correlated with bone marrow plasma cell infiltration ( R = 0.36, P = 0.007). CONCLUSIONS: In this study, a nnU-Net was trained that can automatically segment pelvic bone marrow from whole-body ADC maps in multicentric data sets with a quality comparable to manual segmentations. This approach allows automatic, objective bone marrow ADC measurements, which agree well with manual ADC measurements and can help to overcome interrater variability or nonrepresentative measurements. Automatically extracted ADC values significantly correlate with bone marrow plasma cell infiltration and might be of value for automatic staging, risk stratification, or therapy response assessment.


Subject(s)
Deep Learning , Multiple Myeloma , Humans , Magnetic Resonance Imaging/methods , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/pathology , Bone Marrow/diagnostic imaging , Retrospective Studies , Whole Body Imaging/methods , Diffusion Magnetic Resonance Imaging/methods
8.
Sci Rep ; 12(1): 20729, 2022 12 01.
Article in English | MEDLINE | ID: mdl-36456574

ABSTRACT

Asynchronous calibration could allow opportunistic screening based on routine CT for early osteoporosis detection. In this phantom study, a bone mineral density (BMD) calibration phantom and multi-energy CT (MECT) phantom were imaged on eight different CT scanners with multiple tube voltages (80-150 kVp) and image reconstruction settings (e.g. soft/hard kernel). Reference values for asynchronous BMD estimation were calculated from the BMD-phantom and validated with six calcium composite inserts of the MECT-phantom with known ground truth. Relative errors/changes in estimated BMD were calculated and investigated for influence of tube voltage, CT scanner and reconstruction setting. Reference values for 282 acquisitions were determined, resulting in an average relative error between calculated BMD and ground truth of - 9.2% ± 14.0% with a strong correlation (R2 = 0.99; p < 0.0001). Tube voltage and CT scanner had a significant effect on calculated BMD (p < 0.0001), with relative differences in BMD of 3.8% ± 28.2% when adapting reference values for tube voltage, - 5.6% ± 9.2% for CT scanner and 0.2% ± 0.2% for reconstruction setting, respectively. Differences in BMD were small when using reference values from a different CT scanner of the same model (0.0% ± 1.4%). Asynchronous phantom-based calibration is feasible for opportunistic BMD assessment based on CT images with reference values adapted for tube voltage and CT scanner model.


Subject(s)
Bone Density , Osteoporosis , Humans , Calibration , Osteoporosis/diagnostic imaging , Phantoms, Imaging , Tomography, X-Ray Computed
9.
Invest Radiol ; 57(11): 752-763, 2022 Nov 01.
Article in English | MEDLINE | ID: mdl-35640004

ABSTRACT

OBJECTIVES: Disseminated bone marrow (BM) involvement is frequent in multiple myeloma (MM). Whole-body magnetic resonance imaging (wb-MRI) enables to evaluate the whole BM. Reading of such whole-body scans is time-consuming, and yet radiologists can transfer only a small fraction of the information of the imaging data set to the report. This limits the influence that imaging can have on clinical decision-making and in research toward precision oncology. The objective of this feasibility study was to implement a concept for automatic, comprehensive characterization of the BM from wb-MRI, by automatic BM segmentation and subsequent radiomics analysis of 30 different BM spaces (BMS). MATERIALS AND METHODS: This retrospective multicentric pilot study used a total of 106 wb-MRI from 102 patients with (smoldering) MM from 8 centers. Fifty wb-MRI from center 1 were used for training of segmentation algorithms (nnU-Nets) and radiomics algorithms. Fifty-six wb-MRI from 8 centers, acquired with a variety of different MRI scanners and protocols, were used for independent testing. Manual segmentations of 2700 BMS from 90 wb-MRI were performed for training and testing of the segmentation algorithms. For each BMS, 296 radiomics features were calculated individually. Dice score was used to assess similarity between automatic segmentations and manual reference segmentations. RESULTS: The "multilabel nnU-Net" segmentation algorithm, which performs segmentation of 30 BMS and labels them individually, reached mean dice scores of 0.88 ± 0.06/0.87 ± 0.06/0.83 ± 0.11 in independent test sets from center 1/center 2/center 3-8 (interrater variability between radiologists, 0.88 ± 0.01). The subset from the multicenter, multivendor test set (center 3-8) that was of high imaging quality was segmented with high precision (mean dice score, 0.87), comparable to the internal test data from center 1. The radiomic BM phenotype consisting of 8880 descriptive parameters per patient, which result from calculation of 296 radiomics features for each of the 30 BMS, was calculated for all patients. Exemplary cases demonstrated connections between typical BM patterns in MM and radiomic signatures of the respective BMS. In plausibility tests, predicted size and weight based on radiomics models of the radiomic BM phenotype significantly correlated with patients' actual size and weight ( P = 0.002 and P = 0.003, respectively). CONCLUSIONS: This pilot study demonstrates the feasibility of automatic, objective, comprehensive BM characterization from wb-MRI in multicentric data sets. This concept allows the extraction of high-dimensional phenotypes to capture the complexity of disseminated BM disorders from imaging. Further studies need to assess the clinical potential of this method for automatic staging, therapy response assessment, or prediction of biopsy results.


Subject(s)
Deep Learning , Neoplasms , Bone Marrow/diagnostic imaging , Feasibility Studies , Humans , Magnetic Resonance Imaging/methods , Pilot Projects , Precision Medicine , Retrospective Studies , Whole Body Imaging
10.
Eur J Cancer ; 167: 112-122, 2022 05.
Article in English | MEDLINE | ID: mdl-35427833

ABSTRACT

BACKGROUND: PD-1/PD-L1 inhibitors do not show activity in mismatch repair proficient (MMRp) colorectal cancer. Inhibition of C-C motif chemokine receptor 5 (CCR5) leads to an antitumoral activation of macrophages, affecting immune cell infiltrates. PICCASSO is a phase I trial exploring safety and efficacy of pembrolizumab and maraviroc in refractory MMRp CRC. METHODS: Twenty patients received pembrolizumab and maraviroc (core period, eight cycles), followed by pembrolizumab monotherapy. Primary endpoint was the feasibility rate (patients without treatment-related grade ≥3 immune-related adverse events, treatment-related grade ≥4 adverse events, or any toxicity-related premature withdrawal of treatment). Secondary endpoints included safety/toxicity, overall response rate (ORR), progression-free survival (PFS), and overall survival (OS). Optional biopsies of liver metastases were performed for analyses of the micromilieu. RESULTS: The feasibility rate was 94.7% [90% CI 77.4-99.7%], with one grade 4 hyperglycemia and no additional ≥ grade 3 treatment-related toxicities. ORR according to RECIST was 5.3%. Median PFS according to RECIST was 2.10 months [95%CI 1.68-2.30], median OS 9.83 months [95% CI, 5.59-20.02]. Disease control rate of poststudy salvage treatment was >70%. Translational analyses showed an increase of antitumoral chemokines during treatment; eotaxin, a chemokine involved in chemotaxis, was identified as a biomarker linked to OS. CONCLUSIONS: Therapy with pembrolizumab and maraviroc was feasible and showed a beneficial toxicity pattern. Clinical activity in MMRp CRC patients was limited with prolonged disease stabilizations observed in single patients. Efficacy of poststudy salvage treatment and OS was higher than expected in this heavily pretreated population. THIS TRIAL IS REGISTERED AT CLINICALTRIALS.GOV: NCT03274804.


Subject(s)
Colorectal Neoplasms , DNA Mismatch Repair , Antibodies, Monoclonal, Humanized , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Colorectal Neoplasms/drug therapy , Colorectal Neoplasms/genetics , Colorectal Neoplasms/pathology , Humans , Immune Checkpoint Inhibitors , Maraviroc/therapeutic use , Microsatellite Repeats
11.
Rofo ; 194(7): 747-754, 2022 07.
Article in English | MEDLINE | ID: mdl-35211927

ABSTRACT

PURPOSE: In patients with malignant lymphoma, disease activity is recommended to be assessed by FDG-PET/CT and the Deauville five-point scale (5-PS). The purpose of this study was to explore the potential of iodine concentration measured in contrast-enhanced dual-layer spectral detector CT (SDCT) as an alternative surrogate parameter for lymphoma disease activity by investigating its correlation with maximum standardized uptake values (SUVmax) and 5-PS. MATERIALS AND METHODS: 25 patients were retrospectively analyzed. Contrast-enhanced SDCT and FDG-PET/CT were performed in the same treatment interval within at most 3 months. CT attenuation values (AV), absolute iodine concentrations (aIC), and normalized iodine concentrations (nIC) of lymphoma lesions were correlated with SUVmax using Spearman's rank correlation coefficient. The performance of aIC and nIC to detect lymphoma activity (defined as 5-PS > 3) was determined using ROC curves. RESULTS: 60 lesions were analyzed, and 31 lesions were considered active. AV, aIC, and nIC all correlated significantly with SUVmax. The strongest correlation (Spearman ρ = 0.71; p < 0.001) and highest area under the ROC curve (AUROC) for detecting lymphoma activity were observed for nIC normalized to inferior vena cava enhancement (AUROC = 0.866). The latter provided sensitivity, specificity, and diagnostic accuracy of 87 %, 75 %, and 80 %, respectively, at a threshold of 0.20. ROC analysis for AV (AUROC = 0.834) and aIC (AUROC = 0.853) yielded similar results. CONCLUSION: In malignant lymphomas, there is a significant correlation between metabolic activity as assessed by FDG-PET/CT and iodine concentration as assessed by SDCT. Iodine concentration shows promising diagnostic performance for detecting lymphoma activity and may represent a potential imaging biomarker. KEY POINTS: · Iodine concentration correlates significantly with SUVmax in lymphoma patients. · Iodine concentration may represent a potential imaging biomarker for detecting lymphoma activity. · Normalization of iodine concentration improves diagnostic performance of iodine concentration. CITATION FORMAT: · Gehling K, Mokry T, Do TD et al. Dual-Layer Spectral Detector CT in Comparison with FDG-PET/CT for the Assessment of Lymphoma Activity. Fortschr Röntgenstr 2022; 194: 747 - 754.


Subject(s)
Iodine , Lymphoma , Diagnosis, Differential , Fluorodeoxyglucose F18 , Humans , Lymphoma/diagnostic imaging , Positron Emission Tomography Computed Tomography/methods , Radiopharmaceuticals , Retrospective Studies
12.
Rofo ; 194(6): 652-659, 2022 06.
Article in English | MEDLINE | ID: mdl-34963190

ABSTRACT

PURPOSE: Adaptation of computed tomography protocols for transcatheter aortic valve implantation (TAVI) planning is required when a first-generation dual-layer spectral CT scanner (DLCT) is used. The purpose of this study was to evaluate the objective image quality of aortic CT angiography (CTA) for TAVI planning using a split-phase technique with reconstruction of 40 keV virtual monoenergetic images (40 keV-VMI) obtained with a DLCT scanner. CT angiography obtained with a single-phase protocol of a conventional single-detector CT (SLCT) was used for comparison. MATERIALS AND METHODS: 75 CTA scans from DLCT were retrospectively compared to 75 CTA scans from SLCT. For DLCT, spiral CTA without ECG-synchronization was performed immediately after a retrospectively ECG-gated acquisition covering the heart and aortic arch. For SLCT, spiral CTA with retrospective ECG-gating was performed to capture the heart and the access route simultaneously in one scan. Objective image quality was compared at different levels of the arterial access route. RESULTS: 40 keV virtual monoenergetic images of DLCT showed a significantly higher mean vessel attenuation, SNR, and CNR at all levels of the arterial access route. With 40 keV-VMI of DLCT, the overall mean aortic attenuation of all six measured regions was 589.6 ±â€Š243 HU compared to 492.7 ±â€Š209 HU of SLCT (p < 0.01). A similar trend could be observed for SNR (23.6 ±â€Š18 vs. 18.6 ±â€Š9; p < 0.01) and CNR (21.1 ±â€Š18 vs. 16.4 ±â€Š8; p < 0.01). No deterioration was observed for vascular noise (27.8 ±â€Š9 HU vs. 28.1 ±â€Š8 HU; p = 0.599). CONCLUSION: Using a DLCT scanner with a split-phase protocol and 40 keV-VMI for TAVI planning, higher objective image quality can be obtained compared to a single-phase protocol of a conventional CT scanner. KEY POINTS: · Adaption of TAVI planning CT protocols may be required when using a first-generation dual-layer CT scanner.. · Reconstruction of virtual monoenergetic images at 40 keV improves image quality.. · With a split-phase protocol, the radiation dose is lower compared to a single-phase ECG-gated CT acquisition.. CITATION FORMAT: · Mangold D, Salatzki J, Riffel J et al. Dual-Layer Spectral CTA for TAVI Planning Using a Split-Phase Protocol and Low-keV Virtual Monoenergetic Images: Improved Image Quality in Comparison with Single-Phase Conventional CTA. Fortschr Röntgenstr 2022; 194: 652 - 659.


Subject(s)
Transcatheter Aortic Valve Replacement , Computed Tomography Angiography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Retrospective Studies , Signal-To-Noise Ratio , Tomography, X-Ray Computed/methods , Transcatheter Aortic Valve Replacement/methods
13.
Invest Radiol ; 57(4): 272-281, 2022 04 01.
Article in English | MEDLINE | ID: mdl-34839306

ABSTRACT

BACKGROUND/OBJECTIVES: Apparent diffusion coefficient (ADC) and signal intensity (SI) measurements play an increasing role in magnetic resonance imaging (MRI) of monoclonal plasma cell disorders. The purpose of this study was to assess interrater variability, repeatability, and reproducibility of ADC and SI measurements from bone marrow (BM) under variation of MRI protocols and scanners. PATIENTS AND METHODS: Fifty-five patients with suspected or confirmed monoclonal plasma cell disorder were prospectively included in this institutional review board-approved study and underwent several measurements after the standard clinical whole-body MR scan, including repeated scan after repositioning, scan with a second MRI protocol, scan at a second 1.5 T scanner with a harmonized MRI protocol, and scan at a 3 T scanner. For T1-weighted, T2-weighted STIR, B800 images, and ADC maps, regions of interest were placed in the BM of the iliac crest and sacral bone, and in muscle tissue for image normalization. Bland-Altman plots were constructed, and absolute bias, relative bias to mean, limits of agreement, and coefficients of variation were calculated. RESULTS: Interrater variability and repeatability experiments showed a maximal relative bias of -0.077 and a maximal coefficient of variation of 16.2% for all sequences. Although the deviations at the second 1.5 T scanner with harmonized MRI protocol to the first 1.5 T scanner showed a maximal relative bias of 0.124 for all sequences, the variation of the MRI protocol and scan at the 3 T scanner led to large relative biases of up to -0.357 and -0.526, respectively. When comparing the 3 T scanner to the 1.5 T scanner, normalization to muscle reduced the bias of T1-weighted and T2-weighted sequences, but not of ADC maps. CONCLUSIONS: The MRI scanners with identical field strength and harmonized MRI protocols can provide relatively stable quantitative measurements of BM ADC and SI. Deviations in MRI field strength and MRI protocol should be avoided when applying ADC cutoff values, which were established at other scanners or when performing multicentric imaging trials.


Subject(s)
Bone Marrow , Plasma Cells , Bone Marrow/diagnostic imaging , Diffusion Magnetic Resonance Imaging/methods , Humans , Magnetic Resonance Imaging , Prospective Studies , Reproducibility of Results
14.
Clin Neuroradiol ; 32(2): 547-556, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34499182

ABSTRACT

PURPOSE: Magnetic resonance neurography (MRN) can detect dorsal root ganglia (DRG) hypertrophy in patients with oxaliplatin-induced peripheral neuropathy (OXIPN) but is difficult to apply in clinical daily practice. Aims of this study were (i) to assess whether DRG volume is reliably measurable by routine computed tomography (CT) scans, (ii) to measure longitudinal changes in DRG during and after oxaliplatin administration and (iii) to assess correlation between DRG morphometry and individual oxaliplatin dose. METHODS: For comparison of MRN and CT measurements, CT scans of 18 patients from a previous MRN study were analyzed. For longitudinal assessment of DRG size under treatment, 96 patients treated with oxaliplatin between January and December 2014 were enrolled retrospectively. DRG volumetry was performed by analyzing routine CT scans, starting with the last scan before oxaliplatin exposure (t0) and up to four consecutive timepoints after initiation of oxaliplatin therapy (t1-t4) with the following median and ranges in months: 3.1 (0.4-4.9), 6.2 (5.3-7.8), 10.4 (8.2-11.9), and 18.4 (12.8-49.8). RESULTS: DRG volume measured in CT showed a moderately strong correlation with MRN (r = 0.51, p < 0.001) and a strong correlation between two consecutive CTs (r = 0.77, p < 0.001). DRG volume increased after oxaliplatin administration with a maximum at timepoint t2. Higher cumulative oxaliplatin exposure was associated with significantly higher absolute DRG volumes (p = 0.005). Treatment discontinuation was associated with a nonsignificant trend towards lower relative DRG volume changes (p = 0.08). CONCLUSION: CT is a reliable method for continuous DRG morphometry; however, since no standardized assessment of OXIPN was performed in this retrospective study, correlations between DRG size, cumulative oxaliplatin dose and clinical symptoms in future prospective studies are needed to establish DRG size as a potential OXIPN biomarker.


Subject(s)
Antineoplastic Agents , Peripheral Nervous System Diseases , Antineoplastic Agents/adverse effects , Ganglia, Spinal/diagnostic imaging , Ganglia, Spinal/pathology , Humans , Oxaliplatin/adverse effects , Peripheral Nervous System Diseases/chemically induced , Peripheral Nervous System Diseases/diagnostic imaging , Peripheral Nervous System Diseases/drug therapy , Retrospective Studies , Tomography , Tomography, X-Ray Computed
15.
Radiologe ; 61(12): 1078-1089, 2021 Dec.
Article in German | MEDLINE | ID: mdl-34889973

ABSTRACT

BACKGROUND: Plasma cell dyscrasias are a spectrum of diseases characterized by clonal plasma cell proliferation. Important entities within this group are monoclonal gammopathy of unknown significance, smoldering multiple myeloma, and symptomatic multiple myeloma. PURPOSE: The goal of this review is to illustrate plasma cell dyscrasia imaging findings of bone and bone marrow as seen on whole-body computed tomography (CT) and magnetic resonance imaging (MRI) and to discuss the relevance of imaging for management of patients with plasma cell dyscrasias. MATERIALS AND METHODS: Selective literature search with analysis of dedicated original research articles and reviews and discussion of clinical guidelines. RESULTS: Diagnostic classification of plasma cell dyscrasias is based on the SLiM-CRAB criteria. CT primarily represents imaging of mineralized bone to show osseous end organ damage by detecting osteodestruction. MRI is primarily used for bone marrow imaging to detect diffuse or focal bone marrow infiltration, even in the absence of bone destruction. Different patterns of bone marrow infiltration can be distinguished. Treatment response is associated with characteristic imaging signs of lesion regression. CONCLUSION: Imaging plays a prominent role in treatment stratification of patients with plasma cell dyscrasia at first diagnosis and during follow-up.


Subject(s)
Multiple Myeloma , Paraproteinemias , Bone and Bones , Humans , Magnetic Resonance Imaging , Multiple Myeloma/diagnostic imaging , Paraproteinemias/diagnostic imaging , Tomography, X-Ray Computed
16.
PLoS Negl Trop Dis ; 15(5): e0009365, 2021 05.
Article in English | MEDLINE | ID: mdl-33979343

ABSTRACT

BACKGROUND: In patients with hepatic cystic echinococcosis (CE), treatment effectiveness, outcomes, complications, and recurrence rate are controversial. Endocystectomy is a conservative surgical approach that adequately removes cyst contents without loss of parenchyma. This conservative procedure has been modified in several ways to prevent complications and to improve surgical outcomes. This systematic review aimed to evaluate the intraoperative and postoperative complications of endocysectomy for hepatic CE as well as the hepatic CE recurrence rate following endocystectomy. METHODS: A systematic search was made for all studies reporting endocystectomy to manage hepatic CE in PubMed, Web of Science, and Cochrane CENTRAL databases. Study quality was assessed using the methodological index for non-randomized studies (MINORS) criteria and the Cochrane revised tool to assess risk of bias in randomized trials (RoB2). The random-effects model was used for meta-analysis and the arscine-transformed proportions were used to determine complication-, mortality-, and recurrence rates. This study is registered with PROSPERO (number CRD42020181732). RESULTS: Of 3,930 retrieved articles, 54 studies reporting on 4,058 patients were included. Among studies reporting preoperative anthelmintic treatment (31 studies), albendazole was administered in all of them. Complications were reported in 19.4% (95% CI: 15.9-23.2; I2 = 84%; p-value <0.001) of the patients; biliary leakage (10.1%; 95% CI: 7.5-13.1; I2 = 81%; p-value <0.001) and wound infection (6.6%; 95% CI: 4.6-9; I2 = 27%; p-value = 0.17) were the most common complications. The post-endocystectomy mortality rate was 1.2% (95% CI: 0.8-1.8; I2 = 21%; p-value = 0.15) and the recurrence rate was 4.8% (95% CI: 3.1-6.8; I2 = 87%; p-value <0.001). Thirty-nine studies (88.7%) had a mean follow-up of more than one year after endocystectomy, and only 14 studies (31.8%) had a follow-up of more than five years. CONCLUSION: Endocystectomy is a conservative and feasible surgical approach. Despite previous disencouraging experiences, our results suggest that endocystectomy is associated with low mortality and recurrence.


Subject(s)
Cysts/parasitology , Cysts/surgery , Echinococcosis, Hepatic/surgery , Echinococcosis/surgery , Liver/surgery , Albendazole/therapeutic use , Animals , Anticestodal Agents/therapeutic use , Echinococcus granulosus , Humans , Intraoperative Complications/prevention & control , Liver/parasitology , Postoperative Complications/prevention & control
17.
Cancers (Basel) ; 13(7)2021 Apr 02.
Article in English | MEDLINE | ID: mdl-33918340

ABSTRACT

Chimeric antigen receptor T (CAR-T) cell therapy has proven to be very effective in patients with relapsed/refractory acute lymphoblastic leukemia (ALL) and non-Hodgkin lymphoma (NHL). However, infections-related either due to lymphodepletion or the CAR-T cell therapy itself-can result in severe and potentially life-threatening complications, while side effects such as cytokine release syndrome (CRS) might complicate differential diagnosis. Sixty-seven dosings of CAR-T cells in sixty adult patients with NHL (85%) and ALL (15%) receiving CAR-T cell therapy were assessed for infectious complications. Almost two-thirds of patients (61%) developed fever following lymphodepletion and CAR-T cell dosing. Microbiological or radiological findings were observed in 25% of all cases (bacterial 12%, viral 5%, fungal 8%). Inpatient infections were associated with more lines of therapy and more severe CRS. However, overall serious complications were rare after CAR-T therapy, with one patient dying of infection. Pathogen detection after inpatient stay was infrequent and mostly occurred in the first 90 days after dosing. Infections in CAR-T cell treated patents are common. Fast and suitable identification and treatment are crucial in these heavily pretreated and immunocompromised patients. In most cases infectious complications are manageable. Nonetheless, standardized anti-infective prophylaxis and supportive therapy are mandatory to reduce morbidity and mortality in CAR-T cell therapy.

18.
BMC Med Imaging ; 21(1): 10, 2021 01 11.
Article in English | MEDLINE | ID: mdl-33430780

ABSTRACT

BACKGROUND: Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP. METHODS: This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis. RESULTS: Overall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s). CONCLUSIONS: Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.


Subject(s)
Bile Ducts/diagnostic imaging , Cholangiopancreatography, Magnetic Resonance/methods , Imaging, Three-Dimensional/methods , Pancreas/diagnostic imaging , Adult , Aged , Artifacts , Female , Humans , Male , Middle Aged , Observer Variation , Respiration , Retrospective Studies , Young Adult
19.
Article in English | MEDLINE | ID: mdl-33087940

ABSTRACT

BACKGROUND AND AIM: Assessment of appropriateness of CT pulmonary angiograms (CTPA) in patients with suspected pulmonary embolism (PE) is based on risk stratification algorithms such as simplified the Geneva Score (sGS) in combination with D-dimer blood tests. The aim of this study was to validate the diagnostic yield and appropriateness of CTPA examinations in accordance with 2014 European Society of Cardiology (ESC) guidelines. MATERIALS AND METHODS: Data from 155 outpatients who underwent CTPA for clinical suspicion of PE were gathered from the radiology information system (RIS) and the clinical information system (CIS). We assessed the presence of sGS items and D-dimer blood test results in RIS from CTPA request forms and from clinical documentation in CIS. RESULTS: Based on the RIS, there were 2.6% patients with high (sGS≥3) and 97.4% patients with low pre-test PE probability (sGS<3), and CTPA indication was formally comprehendible in 75.5% using sGS and D-dimer blood tests. Based on RIS and CIS data in combination, there were 41.3% patients with high and 58.7% patients with low pre-test PE probability, and CTPA indication was formally comprehendible in 88.4%. Using RIS and CIS in combination, PE probability was upgraded from low to high probability in 39.7% compared with RIS alone. In 12.9%, there was a lack of data in RIS for CTPA justification. CONCLUSION: There is a high diagnostic yield when applying current diagnostic guidelines to our data. There was however a notable discrepancy between the data transferred to the CTPA request forms from the full clinical documentation, therefore not readily available for clinical decision making.


Subject(s)
Computed Tomography Angiography , Pulmonary Embolism/diagnostic imaging , Aged , Aged, 80 and over , Female , Fibrin Fibrinogen Degradation Products/analysis , Humans , Male , Middle Aged , Practice Guidelines as Topic , Pulmonary Embolism/blood , Retrospective Studies , Risk Assessment
20.
Insights Imaging ; 11(1): 106, 2020 Sep 29.
Article in English | MEDLINE | ID: mdl-32990824

ABSTRACT

OBJECTIVES: Our aim was to develop a structured reporting concept (structured oncology report, SOR) for general follow-up assessment of cancer patients in clinical routine. Furthermore, we analysed the report quality of SOR compared to conventional reports (CR) as assessed by referring oncologists. METHODS: SOR was designed to provide standardised layout, tabulated tumour burden documentation and standardised conclusion using uniform terminology. A software application for reporting was programmed to ensure consistency of layout and vocabulary and to facilitate utilisation of SOR. Report quality was analysed for 25 SOR and 25 CR retrospectively by 6 medical oncologists using a 7-point scale (score 1 representing the best score) for 6 questionnaire items addressing different elements of report quality and overall satisfaction. A score of ≤ 3 was defined as a positive rating. RESULTS: In the first year after full implementation, 7471 imaging examinations were reported using SOR. The proportion of SOR in relation to all oncology reports increased from 49 to 95% within a few months. Report quality scores were better for SOR for each questionnaire item (p < 0.001 each). Averaged over all questionnaire item scores were 1.98 ± 1.22 for SOR and 3.05 ± 1.93 for CR (p < 0.001). The overall satisfaction score was 2.15 ± 1.32 for SOR and 3.39 ± 2.08 for CR (p < 0.001). The proportion of positive ratings was higher for SOR (89% versus 67%; p < 0.001). CONCLUSIONS: Department-wide structured reporting for follow-up imaging performed for assessment of anticancer treatment efficacy is feasible using a dedicated software application. Satisfaction of referring oncologist with report quality is superior for structured reports.

SELECTION OF CITATIONS
SEARCH DETAIL
...