Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
RSC Adv ; 14(25): 18080-18092, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38841398

ABSTRACT

Twelve tricarbonyl rhenium(i) complexes in the '2 + 1' system with the anionic bidentate N,O-donor ligand (deprotonated 8-hydroxyquinoline (HQ) or its 2-methyl (MeHQ) or 5-chloro (ClHQ) derivative) and neutral N-donor diazoles (imidazole (Him), 2-methylimidazole (MeHim), 3,5-dimethylpyrazole (Hdmpz), and 3-phenylpyrazole (HPhpz)) were synthesized: [Re(CO)3(LN,O)LN] (LN,O = Q-, MeQ-, ClQ-; LN = Him, MeHim, Hdmpz, HPhpz). Their crystal structures were determined by the scXRD method, compared with the DFT-calculated ones, and characterized by analytical (EA) and spectroscopic techniques (FT-IR, NMR, and UV-Vis) interpreted with DFT and TD-DFT calculations. Most of the Re(i) complexes did not show relevant antibacterial activity against Gram-negative and Gram-positive bacterial strains. Only [Re(CO)3(MeQ)Him] demonstrated significant action 4-fold better against Gram-negative Pseudomonas aeruginosa than the free MeHQ ligand. The cytotoxicity of the compounds was estimated using human acute promyelocytic leukemia (HL-60), ovarian (SKOV-3), prostate (PC-3), and breast (MCF-7) cancer, and breast non-cancerous (MCF-10A) cell lines. Only HQ and ClHQ ligands and [Re(CO)3(Q)Hdmpz] complex had good selectivity toward MCF-7 cell line. HL-60 cells were sensitive to all complexes (IC50 = 1.5-14 µM). Still, pure HQ and ClHQ ligands were slightly more active than the complexes.

2.
Biomedicines ; 11(2)2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36831028

ABSTRACT

Accurate and rapid identification of COVID-19 is critical for effective patient treatment and disease outcomes, as well as the prevention of SARS-CoV-2 transmission. Rapid antigen tests (RATs) for identifying SARS-CoV-2 are simpler, faster and less expensive than molecular assays. Any new product to be considered a medical device is subject to evaluation and data analysis to verify the in vitro diagnostic ability to achieve its intended purpose. Clinical validation of such a test is a prerequisite before clinical application. This study was a clinical validation on adult Europeans of GenBody COVID-19 Ag, nasal and nasopharyngeal RATs. A set of 103 positive and 301 negative from nose and nasopharynx samples confirmed by RT-qPCR were examined. The tests were safe to use and showed 100% specificity in both specimens, and high sensitivity of 94.17% (95%CI 87.75% to 97.83%) and 97.09% (95%CI 91.72% to 99.4%), respectively. The parameters were significantly better for samples with higher virus loads (the highest for CT ≤ 25). The GenBody COVID-19 Ag RATs are inexpensive (compared to RT-qPCR), reliable and rapid with high sensitivity and specificity, making them suitable for diagnosis and timely isolation and treatment of COVID-19 patients, contributing to the better control of virus spread.

3.
Int J Mol Sci ; 23(16)2022 Aug 20.
Article in English | MEDLINE | ID: mdl-36012683

ABSTRACT

Rapid identification of SARS-CoV-2 variants is essential for epidemiological surveillance. RT-qPCR-based variant differentiation tests can be used to quickly screen large sets of samples for relevant variants of concern/interest; this study was conducted on specimens collected at 11 centers located in Poland during routine SARS-CoV-2 diagnostics between August 2020 and December 2021. A total of 1096 samples (with CT < 30) were screened for Alpha, Beta, Delta, Kappa and Omicron variants using commercial assays targeting repeat mutation sites. Variants were assigned to 434 (39.6%) specimens; the remaining 662 (60.4%) samples were not classified (no tested mutations detected). Alpha (n = 289; 66.59%), Delta (n = 115; 26.5%), Kappa (n = 30; 6.91%) and Omicron (n = 2; 0.46%) variants were identified and their distribution changed over time. The first Alpha variant appeared in October 2020, and it began to gradually increase its proportion of the virus population by June 2021. In July 2021, it was replaced by the Delta variant, which already dominated by the end of the year. The first Kappa was detected in October 2021, while Omicron was found in December 2021. The screening of samples allowed the determination of epidemiological trends over a time interval reflecting the national COVID-19 waves.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19 Testing , Humans , Mutation , Poland/epidemiology , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics
4.
Pathogens ; 11(4)2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35456150

ABSTRACT

One of the tools to contain the SARS-CoV-2 pandemic was to increase the number of performed tests and to improve the access to diagnostics. To this effect, mobile collection sites (MCSs) were established. This study was performed on samples collected at the MCS between November 2020 and March 2021. We aimed to confirm/exclude SARS-CoV-2, differentiate SARS-CoV-2 variants, and detect other respiratory pathogens. SARS-CoV-2 and other respiratory viruses were identified by RT-qPCRs. A total of 876 (46.35%) SARS-CoV-2 positive specimens in the diagnostic tests were identified. The wild-type variant was determined in 667 (76.14%) samples; the remaining 209 (23.86%) samples specimens were identified as Alpha variant. A total of 51 (5.6%) non-SARS-CoV-2 cases were detected in retrospective studies. These accounted for 33 cases of mono-infection including rhinovirus (RV), human adenovirus (HAdV), human metapneumovirus (HMPV), enterovirus (EV), and influenza virus, and 18 cases of co-infection (SARS-CoV-2 with RV or HAdV or HMPV, and RV with EV). Our research shows that the results obtained from the MCS have value in epidemiological studies, reflecting national trends on a micro scale. Although the spread of COVID-19 is a major public health concern, SARS-CoV-2 is not the only pathogen responsible for respiratory infections.

5.
Molecules ; 27(1)2021 Dec 29.
Article in English | MEDLINE | ID: mdl-35011415

ABSTRACT

Synthesis, single-crystal X-ray determination diffraction and FT-IR, NMR (1H, 13C, 19F and 205Tl), UV-vis, and luminescence spectra characteristics were described for series of thallium(I) compounds: thallium(I) triflate (Tl(OTf)), 1:1 co-crystals of thallium(I) triflate and tropolone (Htrop), Tl(OTf)·Htrop, as well as simple thallium(I) chelates: Tl(trop) (1), Tl(5-metrop) (2), Tl(hino) (3), with Htrop, 5-methyltropolone (5-meHtrop), 4-isopropyltropolone (hinokitiol, Hhino), respectively, and additionally more complex {Tl@[Tl(hino)]6}(OTf) (4) compound. Comparison of their antimicrobial activity with selected lead(II) and bismuth(III) analogs and free ligands showed that only bismuth(III) complexes demonstrated significant antimicrobial activity, from two- to fivefold larger than the free ligands.


Subject(s)
Anti-Infective Agents/chemistry , Anti-Infective Agents/pharmacology , Thallium/chemistry , Tropolone/chemistry , Tropolone/pharmacology , Anti-Infective Agents/chemical synthesis , Bismuth/chemistry , Chemistry Techniques, Synthetic , Lead/chemistry , Magnetic Resonance Spectroscopy , Models, Molecular , Molecular Conformation , Molecular Structure , Spectrum Analysis , Structure-Activity Relationship , Tropolone/analogs & derivatives , Tropolone/chemical synthesis
6.
Opt Express ; 24(18): 20119-31, 2016 Sep 05.
Article in English | MEDLINE | ID: mdl-27607620

ABSTRACT

We present the concept, the fabrication processes and the experimental results for materials and optics that can be used for terahertz field-effect transistor detector focal plane arrays. More specifically, we propose 3D printed arrays of a new type - diffractive multi-zone lenses of which the performance is superior to that of previously used mono-zone diffractive or refractive elements and evaluate them with GaN/AlGaN field-effect transistor terahertz detectors. Experiments performed in the 300-GHz atmospheric window show that the lens arrays offer both a good efficiency and good uniformity, and may improve the signal-to-noise ratio of the terahertz field-effect transistor detectors by more than one order of magnitude. In practice, we tested 3 × 12 lens linear arrays with printed circuit board THz detector arrays used in postal security scanners and observed significant signal-to-noise improvements. Our results clearly show that the proposed technology provides a way to produce cost-effective, reproducible, flat optics for large-size field-effect transistor THz-detector focal plane arrays.

SELECTION OF CITATIONS
SEARCH DETAIL
...