Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
J Colloid Interface Sci ; 664: 53-62, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38458055

ABSTRACT

As a progressive electronic energy storage device, the flexible supercapacitor holds tremendous promise for powering wearable/portable electronic products. Of various pseudocapacitor materials, vanadium dioxide (VO2) has garnered extensive attention due to its impressive theoretical capacitance. However, the challenges of inferior cycling life and lower energy density to be addressed. Herein, we prepare VO2 nanorods with winding carbon nanotubes (CNT) via a facile solvothermal route, followed by in situ polymerization of polyaniline (PANI) shell. Taking full advantage of the synergistic effect, the VO2/CNT@PANI composite delivers a high specific capacitance of 354.2F/g at 0.5 A/g and a long cycling life of âˆ¼ 88.2 % over 5000 cycles resulting from the enhanced conductivity of CNT and stabilization of PANI shell. By screen printing the formulated inks with outstanding rheological behaviours, we manufacture an in-planar VO2/CNT@PANI symmetric supercapacitor (VO2/CNT@PANI SSC) device featuring an orderly arrangement structure. This device yields a remarkable areal energy density of 99.57 µWh/cm2 at a power density of 387.5 µW/cm2 while retaining approximately âˆ¼ 87.6 % of its initial capacitance after prolonged use. Furthermore, we successfully powered a portable game machine for more than 2 min using two SSCs connected in series with ease. Therefore, this work presents a universal strategy that utilises combination and coating to boost electrochemical performance for flexible high-performance supercapacitors.

2.
Micromachines (Basel) ; 14(10)2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37893292

ABSTRACT

As a typical pseudocapacitor material, VOx possesses mixed valence states, making it an ideal electrode material for symmetric screen-printed supercapacitors. However, its high internal resistance and low energy density are the main hurdles to its widespread application. In this study, a two-dimensional PANI@VOx nanobelt with a core-shell architecture was constructed via a two-step route. This strategy involves the preparation of VOx using a solvothermal method, and a subsequent in situ polymerization process of the PANI. By virtue of the synergistic effect between the VOx core and the PANI shell, the optimal VOx@PANI has an enhanced conductivity of 0.7 ± 0.04 S/Ω, which can deliver a high specific capacitance of 347.5 F/g at 0.5 A/g, a decent cycling life of ~72.0%, and an outstanding Coulomb efficiency of ~100% after 5000 cycles at 5 A/g. Moreover, a flexible all-solid-state symmetric supercapacitor (VOx@PANI SSC) with an in-planar interdigitated structure was screen-printed and assembled on a nickel current collector; it yielded a remarkable areal energy density of 115.17 µWh/cm2 at an areal power density of 0.39 mW/cm2, and possessed outstanding flexibility and mechanical performance. Notably, a "Xiaomi" hygrothermograph (3.0 V) was powered easily by tandem SSCs with an operating voltage of 3.1 V. Therefore, this advanced pseudocapacitor material with core-shell architecture opens novel ideas for flexible symmetric supercapacitors in powering portable/wearable products.

3.
Sci Rep ; 13(1): 9527, 2023 06 12.
Article in English | MEDLINE | ID: mdl-37308521

ABSTRACT

Carbapenem antibiotics are widely used in ICU, and the prevalence of carbapenem-resistant microorganisms (CRO) has increased. This study aimed to assess the role of individualized active surveillance using Xpert Carba-R of carbapenem resistance genes on CRO risk. A total of 3,765 patients were admitted to the ICU of Zhongnan Hospital of Wuhan University between 2020 and 2022. The presence of carbapenem resistance genes were monitored using Xpert Carba-R, and CRO incidence was assigned as the investigated outcome. Of 3,765 patients, 390 manifested the presence of CRO, representing a prevalence of 10.36%. Active surveillance using Xpert Carba-R was associated with a lower CRO risk (odds ratio [OR]: 0.77; 95% confidence interval [CI] 0.62-0.95; P = 0.013), especially for carbapenem-resistant Acinetobacter + carbapenem-resistant Pseudomonas aeruginosa (OR: 0.79; 95% CI 0.62-0.99; P = 0.043), carbapenem-resistant Klebsiella pneumoniae (OR: 0.56; 95% CI 0.40-0.79; P = 0.001), and carbapenem-resistant Enterobacteriaceae (OR: 0.65; 95% CI 0.47-0.90; P = 0.008). Individualized active surveillance using Xpert Carba-R may be associated with a reduction in the overall CRO incidence in ICU. Further prospective studies should be performed to verify these conclusions and guide further management of patients in ICU.


Subject(s)
Acinetobacter , Carbapenem-Resistant Enterobacteriaceae , Humans , Prospective Studies , Watchful Waiting , Carbapenems , Intensive Care Units , Pseudomonas aeruginosa
SELECTION OF CITATIONS
SEARCH DETAIL