ABSTRACT
Stationary phases (SP) prepared by immobilization of polymers on silica or metalized silica are interesting for use in reversed-phase high-performance liquid chromatography (RP-HPLC) due to better protection of residual silanols or Lewis acid sites, as well as ease of preparation. On the other hand, there are no previous reports of the use of such phases in packed column supercritical fluid chromatography (SFC). Fourteen different SPs based on polysiloxanes (phenyl, C1, C8, C14, C18) thermally immobilized onto different supports (silica, titanized silica, zirconized silica) and one chemically bonded and end-capped C18 stationary phase having a doubly zirconized silica support, were characterized with identical SFC conditions (CO2 with 10% of methanol, 25°C, 15.0 MPa backpressure). Characterization was achieved based on retention factors measured for 85 test compounds and linear solvation energy relationships (LSER), namely the solvation parameter model based on Abraham descriptors. The polysiloxane SP were compared to a commercial C18-bonded silica (Kromasil C18), and to the native silica and metalized silica supports to better unravel the effects of stationary phase chemistry on chromatographic behavior. Together, 19 stationary phases were compared. The results highlight the variety of polarities provided by the column set. The polysiloxane backbone contributes significantly to the SP polarity as evidenced by the comparison to a classical alkylsiloxane-bonded SP. Metalization also appears to modify the polar characteristics of the SP, particularly toward basic compounds. Sample applications illustrate the applicability of these SP in SFC to the analysis of compounds of interest to the pharmaceutical and cosmetic industries.
Subject(s)
Chromatography, Supercritical Fluid/instrumentation , Models, Chemical , Silicon Dioxide/chemistry , Siloxanes/chemistry , Benzene Derivatives/analysis , Benzene Derivatives/chemistry , Chromatography, Supercritical Fluid/methods , Principal Component Analysis , Sunscreening Agents/analysis , Sunscreening Agents/chemistryABSTRACT
This article reports on an evaluation of the Merck Childhood Asthma Network, Inc. (MCAN) initiative using pooled cross-site data on patient-reported outcomes pre- and postintervention to quantify the changes experienced by children in five program sites supported by the network. The results show a consistent pattern of improvement across all measured outcomes, including symptoms, hospital and emergency department use, school absences, and caregiver confidence. Children who started with uncontrolled asthma experienced larger improvements than children with controlled asthma at baseline. However, even considering the significant gains made by children with uncontrolled asthma at baseline, after 12 months, most of the outcomes for these children were significantly worse than the 12-month outcomes for children with controlled asthma at baseline. The evaluation of the MCAN initiative offers a model that can be used in cases where resources must be balanced between evaluation and delivering services to children. The design process and results from the common survey instrument provide information for future initiatives seeking to translate evidence-based interventions in a community-based setting.