Heart Rhythm ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39245249

ABSTRACT

BACKGROUND: Lead-related venous stenosis and occlusion can complicate the insertion or replacement of transvenous leads in patients with cardiac implantable electronic devices (CIED). A possible solution is to tunnel the lead from the contralateral vasculature to the ipsilateral generator. Procedural complications and long term outcomes remain unclear with this technique. OBJECTIVE: We sought to assess outcomes of tunneled transvenous leads. METHODS: We retrospectively identified all patients who underwent transvenous CIED lead tunneling to a contralateral pocket at our institution between 2014 and 2024. Clinical characteristics, indications for lead implant, post-operative complications and long-term outcomes were collected. RESULTS: We identified 27 patients underwent transvenous lead tunneling at our institution. Most patients were males (74%) with an average age of 68.8 ± 18.3 years old. Most patients had non-ischemic cardiomyopathy (59%) with an average ejection fraction of 29.3 ± 11.3 %. The tunneled leads were coronary sinus leads (20), followed by defibrillator leads (5) and RV pacing leads (2). Implants were primarily for device upgrade (18), lead revisions (8), or de-novo lead placement (1). No post-operative complications were seen. Patients were followed for an average of 2.2 ± 1.4 years. One tunneled defibrillator lead (3.7%) had low shock impedance 3 years after implant which was monitored and did not require an intervention. CONCLUSION: In patients with ipsilateral venous occlusion, contralateral lead tunneling appears to be an effective and safe approach to manage CIED patients with occluded ipsilateral subclavian veins.

2.
Article in English | MEDLINE | ID: mdl-39248361

ABSTRACT

BACKGROUND: Most studies of device-detected atrial fibrillation (AF) have recommended indefinite anticoagulation once a patient crosses a particular threshold for AF duration or burden. However, durations and burdens are known to fluctuate over time, but little is known about the magnitude of spontaneous fluctuations and the potential impact on anticoagulation decisions. OBJECTIVE: To quantify spontaneous fluctuations in AF duration and burden in patients with implantable loop recorders (ILRs) METHODS: We reviewed all ILR interrogations for patients with non-permanent AF at our institution from 2018 to 2023. We excluded patients treated with rhythm control. The duration of longest AF episode at each interrogation was classified as < 6, 6-24, and > 24 h, and the AF burden reported at each interrogation was classified as < 2%, 2%-11.4%, and > 11.4%. RESULTS: Out of 156 patients, the mean age at ILR implant was 70.9 ± 12.5 years, CHA2DS2-VASc score was 4.2 ± 1.8, duration of ILR follow-up was 23.4 ± 11.2 months, and number of ILR interrogations per patient was 18.0 ± 8.9. The duration of longest AF episode at any point during follow-up was < 6 , 6-24 , and > 24 h in 110, 30, and 16 patients, respectively. Among the 30 patients with a longest AF episode of 6-24 h at some point during follow-up, out of 594 total ILR interrogations, only 75 (12%) showed a longest episode of 6-24 h. In the remaining 519 interrogations, the longest episode was < 6 h. In patients with a longest episode of > 24 h at any point during follow-up (n = 16), only 47 out of 320 total ILR interrogations (15%) showed an episode of > 24 h. When evaluating AF burden, 96, 38, and 22 patients had maximum reported AF burdens of < 2%, 2%-11.4%, and > 11.4% at any point during ILR follow-up. Among those with a maximum burden of 2%-11.4% at some point during follow-up (n = 38), out of 707 ILR interrogations, only 76 (11%) showed a burden of 2%-11.4%. In the remaining 631 interrogations, the burden was < 2%. In the 22 patients with a burden > 11.4% at some point during follow-up, only 80 out of 480 interrogations (17%) showed a burden of > 11.4%. In 65% of interrogations, the burden was < 2%. CONCLUSION: Significant, spontaneous fluctuations in AF burden and duration are common in patients with ILRs. Even in patients with AF episodes of 6-24 h or > 24 h at some point during follow-up, the vast majority of interrogations show episodes of < 6 h. Similarly, in patients with burdens of 2%-11.4% or > 11.4% at some point during follow-up, the vast majority of interrogations show burdens of < 2%. More data are needed to determine whether crossing an AF burden or duration threshold once is sufficient to merit lifelong anticoagulation or whether spontaneous fluctuations in AF burden and duration should impact anticoagulation decisions.

4.
Heart Rhythm ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38969051

ABSTRACT

BACKGROUND: Data on transvenous (TV) lead-associated superior vena cava (SVC) syndrome are limited. The management of this problem might require a multidisciplinary approach, often involving transvenous lead extraction (TLE) followed by angioplasty and stenting. OBJECTIVE: The purpose of this study was to describe the management and outcome of TV lead-associated SVC syndrome. METHODS: We retrospectively identified patients with a diagnosis of SVC syndrome and TV leads at Emory Healthcare between 2015 and 2023. RESULTS: Fifteen patients with lead-related SVC syndrome were identified. The cohort average age was 50 years. Symptoms included swelling of the face, neck, and upper extremities (67%); shortness of breath (53%); and lightheadedness (40%). Patients had an average of 2 ± 0.7 leads crossing the SVC, with a lead dwell time of 9.8 ± 7.5 years. Thirteen patients were managed with TLE, followed by SVC stenting and angioplasty in 10 and angioplasty alone in 2; 1 patient had no intervention after TLE. One patient was managed with anticoagulation, and another had angioplasty and stenting with lead jailing. One patient experienced SVC perforation and cardiac tamponade during SVC stenting, which was managed successfully with a covered stent and pericardiocentesis. Among the 12 patients with TLE and angioplasty ± stenting, 7 underwent reimplantation of a transvenous lead. Two of those patients had symptoms recurrence, and none of the 5 patients without lead reimplantation had recurrence of symptoms. CONCLUSION: Lead-related SVC syndrome management requires a multidisciplinary approach often including TLE followed by angioplasty and stenting. Avoiding TV lead reimplantation might help reduce symptoms recurrence.

6.
Heart Rhythm ; 2024 May 05.
Article in English | MEDLINE | ID: mdl-38752909

ABSTRACT

BACKGROUND: Because of differences in chest wall anatomy, female patients may have higher rates of subcutaneous implantable cardioverter-defibrillator (S-ICD) pocket-related complications. OBJECTIVE: We sought to evaluate sex-based outcomes after S-ICD implantation. METHODS: Patients implanted with an S-ICD at Emory Healthcare between 2010 and 2023 were included in the analysis. Patients' clinical characteristics and post-S-ICD implantation complications were collected. RESULTS: There were 429 male patients (68%) and 199 female patients (32%) observed for a median duration of 2.3 years (0.6-4.4 years). Male and female patients had comparable rates of diabetes (28%), end-stage renal disease (29.5%), ejection fraction (30.2% ± 13.4%), and body mass index (29.1 ± 6.6 kg/m2). There was no statistical difference in the incidence of shocks between men and women (26.3% vs 20.1%; P = .09), including appropriate shocks (14.7% vs 12%; P = .98) and inappropriate shocks (11.7% vs 9.5%; P = .98). Pocket-related complications occurred in 21 patients; these included pocket infection (n = 12), wound dehiscence (n = 7), and hematoma requiring drainage (n = 2). Female patients had a significantly higher pocket-related complication rate compared with male patients (7.2% vs 2.5%; P = .016). In controlling for age, body mass index, diabetes, and end-stage renal disease, female patients had higher odds of pocket-related complications compared with male patients (odds ratio, 3.15; 95% confidence interval, 1.27-7.75). Pocket-related complications decreased after 2018 compared with before 2018 (6% vs 2.6%, P = .052), mainly driven by reduction in complications in women (12.3% vs 3.2%; P = .034) but not in men (2.8% vs 2.4%; P = 1). CONCLUSION: In this cohort of S-ICD patients, women had a higher rate of post-S-ICD pocket-related complications that could be explained by sex-based differences in anatomy.

7.
J Cardiovasc Electrophysiol ; 35(6): 1212-1216, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38650520

ABSTRACT

BACKGROUND: Early guidance recommended a bolus of intravenous heparin at the beginning of leadless pacemaker (LP) implantation procedures. However, due to concern about bleeding complications, more recent practice has tended toward omitting the bolus and only running a continuous heparin infusion through the introducer sheath. The impact of omitting the heparin bolus on procedural outcomes is not clear. METHODS: We reviewed all Medtronic Micra LP implants at our institution from 9/2014 to 9/2022. The decision to bolus with heparin was at operator discretion. RESULTS: Among 621 LP implants, 326 received an intravenous heparin bolus, 243 did not, and 52 patients were excluded because heparin bolus status could not be confirmed. There was a trend toward more frequent omission of the heparin bolus with more recent implants. Median follow-up after LP implant was 14.3 (interquartile range [IQR]: 8.4-27.9) months. There was no difference between heparin bolus and no bolus groups in the number of device deployments/recaptures (1.42 ± 0.81 vs. 1.31 ± 0.66, p = .15). Implant-related adverse events were also similar between heparin bolus and no bolus groups: access-site hematoma requiring intervention (7 vs. 5, p = .99), pseudoaneurysm (1 vs. 1, p = .99), cardiac perforation (1 vs. 1, p = .99), intraprocedural device thrombus formation (2 vs. 4, p = .41), 30-day rehospitalization (21 vs. 15, p = .98), and 30-day all-cause mortality (16 vs. 14, p = .70). There was one additional nonfatal cardiac perforation in a patient who was excluded due to unknown heparin bolus status. Regarding device electrical parameters between heparin bolus and no bolus groups, there were no significant differences at the time of implant: pacing capture threshold 0.5 ± 0.4 vs. 0.5 ± 0.3, p = .10; pacing impedance 739.9 ± 226.4 vs. 719.1 ± 215.4, p = .52; R wave sensing 11.7 ± 5.7 vs. 12.0 ± 5.4, p = .34). Long-term device performance was also similar between groups. CONCLUSION: Omission of the systemic heparin bolus at the time of LP implantation appears safe in appropriately selected patients. Heparin bolus may still be considered in long cases requiring multiple device deployments or in patients at high risk for thrombotic complications.


Subject(s)
Anticoagulants , Cardiac Pacing, Artificial , Heparin , Pacemaker, Artificial , Humans , Heparin/administration & dosage , Heparin/adverse effects , Male , Aged , Female , Anticoagulants/administration & dosage , Anticoagulants/adverse effects , Treatment Outcome , Retrospective Studies , Time Factors , Risk Factors , Aged, 80 and over , Middle Aged , Drug Administration Schedule , Prosthesis Implantation/instrumentation , Prosthesis Implantation/adverse effects , Prosthesis Design
8.
Heart Rhythm ; 21(8): 1334-1341, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38437891

ABSTRACT

BACKGROUND: Human in vivo data on the chemical stability of different transvenous lead materials, particularly OptimTM leads, are lacking. OBJECTIVES: The purpose of this study was to determine the chemical reactivity of insulation materials by analyzing the molar mass of extracted pacing and defibrillator leads METHODS: We collected extracted leads at Emory University Hospitals and sent the leads with thermoplastic outer insulation material for molar mass analysis, a material characteristic that informs biostability. Leads were separated based on the chemical identity of the outer insulation material, and the molar mass was measured by an independent party. The extent of chemical reaction was compared across leads having different materials: poly(ether)urethane 55D, poly(ether)urethane 80A, and Optim. RESULTS: A total of 70 leads were extracted. The subset of extracted leads having outer insulation materials composed of PEU or Optim were analyzed for molar mass, where implant times ranged from 0.12 to 16.26 years. The rate of chemical degradation was compared by plotting the extent of reaction [Mn(t = 0)/Mn(t)] as a function of implant time. The Optim molar mass decreased to 40% of its initial value at 10 years of implant. No change in the molar mass of the PEU insulations could be resolved over the same 10-year implant time. CONCLUSION: Because the molar mass of a polymer is directly related to its mechanical integrity, the observed decrease in molar mass of Optim likely translates into premature insulation defects and is consistent with the observed increased rate of electrical malfunction/noise in this subset of cardiac leads.


Subject(s)
Pacemaker, Artificial , Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable , Polymers , Materials Testing/methods , Polyurethanes , Electrodes, Implanted/adverse effects , Male , Equipment Design
9.
J Cardiovasc Electrophysiol ; 35(5): 929-938, 2024 May.
Article in English | MEDLINE | ID: mdl-38450808

ABSTRACT

INTRODUCTION: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study is to quantify tricuspid regurgitation (TR) before and after lead extraction and identify predictors of worsening TR. METHODS: We studied 321 patients who had echocardiographic data before and after lead extraction. TR was graded on a scale (0 = none/trivial, 1 = mild, 2 = moderate, 3 = severe). A change of >1 grade following extraction was considered significant. RESULTS: A total of 321 patients underwent extraction of a total of 338 leads across the TV (1.05 ± 0.31 leads across the TV per patient). There was no significant difference on average TR grade pre- and postextraction (1.18 ± 0.91 vs. 1.15 ± 0.87; p = 0.79). TR severity increased after extraction in 84 patients, but was classified as significantly worse (i.e., >1 grade change in severity) in only 8 patients (2.5%). Use of laser lead extraction was associated with a higher rate of worsening TR postextraction (44.0% vs. 31.6%, p = 0.04). CONCLUSION: In our single-center analysis, extraction of leads across the TV did not significantly affect the extent of TR in most patients. Laser lead extraction was associated with a higher rate of worsening TR after extraction.


Subject(s)
Device Removal , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/diagnosis , Male , Female , Device Removal/adverse effects , Aged , Treatment Outcome , Middle Aged , Retrospective Studies , Risk Factors , Severity of Illness Index , Tricuspid Valve/physiopathology , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Defibrillators, Implantable , Time Factors , Pacemaker, Artificial , Aged, 80 and over , Cardiac Resynchronization Therapy Devices
10.
J Interv Card Electrophysiol ; 67(6): 1437-1443, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38413483

ABSTRACT

BACKGROUND: Following catheter ablation, vascular access management involves potential complications and prolonged recovery. Recently, suture-mediated closure (SMC) devices were approved for venous access procedures. The objective of this study is to evaluate the safety of a commercially available SMC for multiple access site venous closure by duplex ultrasound (DUS) in asymptomatic subjects with non-visible complications. METHODS: Thirty-six subjects (63 ± 10.7 years old, 12 female) were enrolled. Following catheter ablation for atrial fibrillation, all subjects had SMC of every venous access site. Subjects underwent DUS of femoral veins and arteries. DUS was performed at discharge, and again at 30 days. Subjects were evaluated for clinically apparent vascular complications. RESULTS: Mean procedure duration was 138.6 min, and the time to hemostasis was 3.1 min/access site and 9.5 min/subject. Median time to ambulation was 193.5 min, and median time to discharge was 5.95 h, with discharge as early as 2.4 h. A median of 2 sheaths/vein and a median of 2 SMC devices/vein were used. There were no major complications and a 16.7% (6/36) minor complication rate at discharge. All complications resolved at 30 days. The complication rate was not higher in patients with 2 SMC per access site as compared to the patients who just received 1 SMC per access site. CONCLUSIONS: This study demonstrates the safety of multi-access closure using SMC, following catheter ablation procedures, for closure of sites that use sheath sizes from ≤ 8F to ≥ 15F and for those that use 2 or more SMCs per access site.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Female , Male , Atrial Fibrillation/surgery , Catheter Ablation/methods , Middle Aged , Atrial Flutter/surgery , Treatment Outcome , Ultrasonography, Doppler, Duplex , Femoral Vein/surgery , Aged , Suture Techniques , Postoperative Complications/epidemiology
12.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-38000900

ABSTRACT

AIMS: Single-connector (DF4) defibrillator leads have become the predominantly implanted transvenous implantable cardioverter-defibrillator lead. However, data on their long-term performance are derived predominantly from manufacturer product performance reports. METHODS AND RESULTS: We reviewed medical records in 5289 patients with DF4 leads between 2011 and 2023 to determine the frequency of lead-related abnormalities. We defined malfunction as any single or combination of electrical abnormalities requiring revision including a sudden increase (≥2×) in stimulation threshold, a discrete jump in high-voltage impedance, or sensing of non-physiologic intervals or noise. We documented time to failure, predictors of failure, and management strategies. Mean follow-up after implant was 4.15 ± 3.6 years (median = 3.63), with 37% of leads followed for >5 years. A total of 80 (1.5%) leads demonstrated electrical abnormalities requiring revision with an average time to failure of 4 ± 2.8 years (median = 3.5). Of the leads that malfunctioned, 62/80 (78%) were extracted and replaced with a new lead and in the other 18 cases, malfunctioned DF4 leads were abandoned, and a new lead implanted. In multivariable models, younger age at implant (OR 1.03 per year; P < 0.001) and the presence of Abbott/St. Jude leads increased the risk of malfunction. CONCLUSION: DF4 defibrillator leads demonstrate excellent longevity with >98.3% of leads followed for at least 5 years still functioning normally. Younger age at implant and lead manufacturer are associated with an increased risk of DF4 lead malfunction. The differences in lead survival between manufacturers require further investigation.


Subject(s)
Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Equipment Failure , Retrospective Studies
13.
J Cardiovasc Electrophysiol ; 34(11): 2216-2222, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37727925

ABSTRACT

INTRODUCTION: Permanent pacing indications are common after cardiac surgery and transcatheter structural valve interventions. Leadless pacemakers (LPs) have emerged as a useful alternative to transvenous pacemakers. However, current commercially available LPs are unable to provide atrial pacing or cardiac resynchronization and relatively little is known about LP outcomes after cardiac surgery and transcatheter valve interventions. METHODS: This retrospective study included patients who received a Micra VR (MicraTM MC1VR01) or Micra AV (MicraTM MC1AVR1) (Medtronic) leadless pacemaker following cardiac surgery or transcatheter structural valve intervention between September 2014 and September 2022. Device performance and clinical outcomes, including ventricular pacing burden, ejection fraction, and need for conversion to transvenous pacing systems, were evaluated during follow-up. RESULTS: A total of 78 patients were included, of whom 40 received a Micra VR LP implant, and 38 received a Micra AV LP implant. The mean age of the cohort was 65.9 ± 17.9 years, and 48.1% were females. The follow-up duration for the entire cohort was 1.3 ± 1.1 years: 1.6 ± 1.3 years for the Micra VR group and 0.8 ± 0.5 years for the Micra AV group. Among the cohort, 50 patients had undergone cardiac surgery and 28 underwent transcatheter structural valve interventions. Device electrical performance was excellent during follow-up, with a small but clinically insignificant increase in ventricular pacing threshold and a slight decrease in pacing impedance. The mean right ventricle pacing (RVP) burden significantly decreased over time in the entire cohort (74.3% ± 37.2% postprocedure vs. 47.7% ± 40.6% at last follow-up, p < .001), and left ventricle ejection fraction (LVEF) showed a modest but significant downward trend during follow-up (55.0% ± 10.6% vs. 51.5% ± 11.2% p < .001). Patients with Micra VR implants had significantly reduced LVEF during follow-up (54.1% ± 11.9% vs. 48.8% ± 11.9%, p = .003), whereas LVEF appeared stable in the Micra AV group during follow-up (56.1% ± 9.0% vs. 54.6% ± 9.7%, p = .06). Six patients (7.7%) required conversion to transvenous pacing systems, four who required cardiac resynchronization for drop in LVEF with high RVP burden and two who required dual-chamber pacemakers for symptomatic sinus node dysfunction. CONCLUSION: Leadless pacemakers provide a useful alternative to transvenous pacemakers in appropriately selected patients after cardiac surgery and transcatheter structural valve interventions. Device performance is excellent over medium-term follow-up. However, a significant minority of patients require conversion to transvenous pacing systems for cardiac resynchronization or atrial pacing support, demonstrating the need for close electrophysiologic follow-up in this cohort.


Subject(s)
Cardiac Surgical Procedures , Pacemaker, Artificial , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Male , Retrospective Studies , Lipopolysaccharides , Treatment Outcome , Equipment Design , Cardiac Pacing, Artificial/adverse effects
14.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37702135

ABSTRACT

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Cardiac Pacing, Artificial/adverse effects , Cardiac Pacing, Artificial/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
16.
Heart Rhythm ; 20(12): 1669-1673, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37591366

ABSTRACT

BACKGROUND: Same-day discharge (SDD) after cardiovascular procedures is rapidly gaining ground. OBJECTIVE: We sought to evaluate the safety of SDD after transvenous lead extraction (TLE). METHODS: We performed a retrospective chart review of patients who underwent elective TLE between January 2020 and October 2021 at our institution. The primary outcome was SDD, and major procedural complications and readmissions within 30 days of the procedure were secondary outcomes. RESULTS: In this analysis of 111 patients who underwent elective TLE, 80 patients (72%) were discharged on the same day (SDD group) while 31 patients (28%) stayed overnight (overnight group). Lead malfunction was the most common indication for TLE in both groups. Patients in the overnight group were more likely to have a lead dwell time of ≤10 years than those in the SDD group (38.7% vs 20% of all leads in each group; P = .042), have laser sheaths used for extraction and a higher number of leads extracted. No major complications were reported in both groups. In a multivariate analysis, lower body mass index and the use of laser sheath during TLE were predictors of overnight stay. Patients who underwent a procedure using advanced extraction techniques were 3.5 times more likely to stay overnight (95% confidence interval 1.27-9.78; P = .016). CONCLUSION: In appropriately selected patients undergoing elective lead extraction, SDD is feasible and safe. Higher body mass index, fewer extracted leads, shorter lead dwell times (<10 years), and less frequent use of laser-powered extraction sheaths were associated with an increased likelihood of SDD.


Subject(s)
Defibrillators, Implantable , Patient Discharge , Humans , Retrospective Studies , Treatment Outcome , Device Removal/adverse effects , Device Removal/methods , Defibrillators, Implantable/adverse effects
17.
J Cardiovasc Electrophysiol ; 34(5): 1111-1118, 2023 05.
Article in English | MEDLINE | ID: mdl-37036297

ABSTRACT

INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters. Pressure waveform data was extracted to compare LA peak pressure, LV peak systolic pressure, LV end-diastolic pressure, and waveform analysis. RESULTS: Comparison between the SG and ablation catheters (AblA; AblB) demonstrated that LV systolic pressure (0.61-16.8 mmHg; 1.32-18.2 mmHg), and LV end-diastolic pressure (-3.4 to 2.8 mmHg; -3.0 to 3.35 mmHg) were well correlated and had accepted repeatability. Ablation waveforms demonstrated an 89.9 ± 6.4% correlation compared to SG waveforms. CONCLUSION: Pressure measurements derived from an irrigated ablation catheter are accurate and reliable when compared to an SG catheter. Further studies are needed to determine how real-time pressure monitoring can improve outcomes during ablation procedures.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Hemodynamics , Heart Atria/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheters , Treatment Outcome
18.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1172-1180, 2023 07.
Article in English | MEDLINE | ID: mdl-36898953

ABSTRACT

BACKGROUND: Class IC antiarrhythmic agents are effective for treating atrial tachyarrhythmias, but their use is restricted in patients with coronary artery disease (CAD). Data on the safety of the use of IC agents in patients with CAD in the absence of recent acute coronary syndromes are lacking. OBJECTIVES: This study sought to evaluate the safety and feasibility of treatment with IC agents in patients with varying degrees of CAD in a large serial, real-world cohort. METHODS: We retrospectively identified all patients at our institution from January 2005 to February 2021 on a IC agent (n = 3,445) and those on sotalol or dofetilide (n = 2,216) as controls, excluding those with a prior history of ventricular tachycardia, implantable cardioverter-defibrillator placement, or nonrevascularized myocardial infarction. Baseline clinical characteristics included degree of CAD (categorized as none, nonobstructive, or obstructive), other comorbid illness, and medication use. Clinical outcomes, including survival, were ascertained. We performed Cox regression analysis to evaluate the effect of IC use on event-free survival across varying degrees of CAD. RESULTS: After adjustment for baseline characteristics, there was an independent association between IC use and improved mortality. However, there was an interaction between IC use and degree of CAD (compared to sotalol) demonstrating poorer event-free survival among those with obstructive coronary disease (HR: 3.80; 95% CI: 1.67-8.67; P = 0.002). CONCLUSIONS: Among select patients with nonobstructive CAD and without a history of ventricular tachycardia, IC agents are not associated with increased mortality. Therefore, these agents may be an option for some patients in whom they are frequently restricted. Further prospective studies are warranted.


Subject(s)
Coronary Artery Disease , Tachycardia, Ventricular , Humans , Coronary Artery Disease/complications , Coronary Artery Disease/drug therapy , Flecainide/adverse effects , Sotalol/therapeutic use , Retrospective Studies , Feasibility Studies , Tachycardia, Ventricular/drug therapy , Tachycardia, Ventricular/complications
20.
Front Cardiovasc Med ; 9: 849113, 2022.
Article in English | MEDLINE | ID: mdl-35571173

ABSTRACT

Background: Initial studies of stereotactic body radiation therapy (SBRT) for refractory ventricular tachycardia (VT) have demonstrated impressive efficacy. Follow-up analyses have found mixed results and the role of SBRT for refractory VT remains unclear. We performed palliative, cardiac radio ablation in patients with ventricular tachycardia refractory to ablation and medical management. Methods: Arrhythmogenic regions were targeted by combining computed tomography imaging with electrophysiologic mapping with collaboration from a radiation oncologist, electrophysiologist and cardiac imaging specialist. Patients were treated with a single fraction 25 Gy. Total durations of VT, the quantity of antitachycardia pacing (ATP) and shocks before and after treatment as recorded by implantable cardioverter-defibrillators (ICDs) were analyzed. Follow-up extended until most recent device interrogation unless transplant, death or repeat ablation occurred sooner. Results: Fourteen patients (age 50-78, four females) were treated and had an average of two prior ablations. Nine had ACC/AHA Stage D heart failure and three had left ventricular assist devices (LVAD). Two patients died shortly after SBRT, one received a prompt heart transplant and another had significant VT durations in the following months that were inaccurately recorded by their device. Ten of the 14 patients remained with adequate data post SBRT for analysis with an average follow-up duration of 216 days. Seven of those 10 patients had a decrease in VT post SBRT. Comparing the 90 days before treatment to cumulative follow-up, patients had a 59% reduction in VT, 39% reduction in ATP and a 60% reduction in shocks. Four patients received repeat ablation following SBRT. Pneumonitis was the only complication, occurring in four of the fourteen patients. Conclusion: SBRT may have value in advanced heart failure patients with refractory VT acutely but the utility over long-term follow-up appears modest. Prospective randomized data is needed to better clarify the role of SBRT in managing refractory VT.