Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Physiol Behav ; 142: 85-9, 2015 Apr 01.
Article in English | MEDLINE | ID: mdl-25659734

ABSTRACT

The nociceptive withdrawal reflex (NWR) model is used in animal pain research to quantify nociception. The aim of this study was to evaluate the NWR evoked by repeated stimulations in healthy, non-medicated standing sheep. Repeated electrical stimulations were applied at 5 Hz for 2s to the digital nerves of the right thoracic and the pelvic limbs of 25 standing sheep. The stimulation intensities applied were fractions (0.5, 0.6, 0.7, 0.8, 0.9 and 1) of the individual previously determined nociceptive threshold (It) after single stimulation. Surface-electromyographic activity (EMG) was recorded from the deltoid, the femoral biceps or the peroneus tertius muscles. The repeated stimulation threshold (RS It) was reached if at least one stimulus in the train was followed by a reflex with a minimal root-mean-square-amplitude (RMSA) of 20 µV. The behavioural reaction following each series of stimulations was scored on a scale from 0 (no reaction) to 5 (vigorous whole-body reaction). For the deltoid muscle, RS It was 2.3 mA (1.6-3 mA) with a reaction score of 2 (1-2) and at a fraction of 0.6 (0.5-0.8)×It. For the biceps femoris muscle, RS It was 2.9 mA (2.6-4 mA) with a reaction score of 1 (1-2) at a fraction of and 0.55 (0.4-0.7)×It while for the peroneus tertius muscle RS It was 3 mA (2.8-3.5 mA) with a reaction score of 1 (1-2) and at a fraction of 0.8 (0.8-0.95)×It. Both, RMSA and reaction scores increased significantly with increasing stimulation intensities in all muscles (p<0.001). The repeated application of electrical stimuli led to temporal summation of nociceptive inputs and therefore a reduction of the stimulus intensity evoking a withdrawal reaction in healthy, standing sheep. Data achieved in this study can now serve as reference for further clinical or experimental applications of the model in this species.


Subject(s)
Electric Stimulation/methods , Nociception/physiology , Sheep/physiology , Animals , Electromyography , Forelimb/physiology , Hindlimb/physiology , Models, Animal , Muscle, Skeletal/physiology , Pain Measurement , Reflex/physiology
2.
Physiol Behav ; 129: 181-5, 2014 Apr 22.
Article in English | MEDLINE | ID: mdl-24561088

ABSTRACT

This study aimed to characterize the nociceptive withdrawal reflex (NWR) and to define the nociceptive threshold in 25 healthy, non-medicated experimental sheep in standing posture. Electrical stimulation of the dorsal lateral digital nerves of the right thoracic and the pelvic limb was performed and surface-electromyography (EMG) from the deltoid (all animals) and the femoral biceps (18 animals) or the peroneus tertius muscles (7 animals) was recorded. The behavioural reaction following each stimulation was scored on a scale from 0 (no reaction) to 5 (strong whole body reaction). A train-of-five 1ms constant-current pulse was used and current intensity was stepwise increased until NWR threshold intensity was reached. The NWR threshold intensity (It) was defined as the minimal stimulus intensity able to evoke a reflex with a minimal Root-Mean-Square amplitude (RMSA) of 20µV, a minimal duration of 10ms and a minimal reaction score of 1 (slight muscle contraction of the stimulated limb) within the time window of 20 to 130ms post-stimulation. Based on this value, further stimulations were performed below (0.9It) and above threshold (1.5It and 2It). The stimulus-response curve was described. Data are reported as medians and interquartile ranges. At the deltoid muscle It was 4.4mA (2.9-5.7) with an RMSA of 62µV (30-102). At the biceps femoris muscle It was 7.0mA (4.0-10.0) with an RMSA of 43µV (34-50) and at the peroneus tertius muscle It was 3.4mA (3.1-4.4) with an RMSA of 38µV (32-46). Above threshold, RMSA was significantly increased at all muscles. Below threshold, RMSA was only significantly smaller than at It for the peroneus tertius muscle but not for the other muscles. Data achieved in this study serve as reference for experimental or clinical applications of the conscious sheep model.


Subject(s)
Electric Stimulation/methods , Muscle, Skeletal/physiology , Nociception/physiology , Pain Measurement/methods , Reflex/physiology , Sheep, Domestic/physiology , Animals , Electromyography , Extremities/physiology , Pain Threshold/physiology , Peripheral Nerves/physiology
3.
J Biomed Mater Res B Appl Biomater ; 101(4): 591-8, 2013 May.
Article in English | MEDLINE | ID: mdl-23281249

ABSTRACT

Carbon fiber-reinforced polyetheretherketone (CF/PEEK) is a thermoplastic composite biomaterial exhibiting properties suitable for load-bearing orthopedic implants. However, the hydrophobic surface of CF/PEEK implants induces the deposition of a peri-implant fibrous tissue capsule preventing bone apposition. However, if bone apposition was improved, the use of CF/PEEK in orthopedics could be increased as it has many advantages compared with metallic implants. In this study, CF/PEEK screws were coated with titanium (Ti) using two different techniques, namely vacuum plasma spraying (VPS) and physical vapor deposition (PVD) with uncoated screws as controls. These coatings were characterized and implanted in a loaded sheep tibia model. In the characterization of the screw surfaces using microscopy techniques, the uncoated screws were seen to have an irregular surface. The PVD coating appeared smooth and consistent, whereas the VPS coating appeared to be a rough coating with some inhomogeneities, which did not cover the entire surface area. Nevertheless, in the ex vivo analysis the VPS-coated screws had a screw removal torque which was statistically greater than uncoated and PVD-coated screws (p ≤ 0.002 for both comparisons). Additionally, the VPS-coated screws had a statistically higher bone contact area than the uncoated screws (p = 0.006), whereas no statistical difference was detected between VPS and PVD coating types (p = 0.11). Thereby illustrating that Ti coating of CF/PEEK screws significantly improve bone apposition and removal torque compared with uncoated CF/PEEK screws.


Subject(s)
Bone Screws , Bone and Bones/drug effects , Carbon/chemistry , Coated Materials, Biocompatible , Ketones/chemistry , Polyethylene Glycols/chemistry , Prostheses and Implants , Titanium/chemistry , Animals , Benzophenones , Carbon Fiber , Female , Internal Fixators , Materials Testing , Polymers , Prosthesis Design , Sheep , Surface Properties , Tibia/pathology , Torque , Weight-Bearing
4.
J Biomed Mater Res B Appl Biomater ; 100(3): 611-7, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22282225

ABSTRACT

Soft tissue-implant adhesion is often required for implant integration into the body; however, in some situations, the tissue is required to glide freely over an implant. In the case of distal radius fracture treatment, current literature describes how titanium and its alloys tend to lead to more intra-tendon inflammatory reactions compared with stainless steel. This leads to tendon-implant adhesion and damage possibly causing limited palmar flexion and even tendon rupture. The goal of this study was to analyze the effect of different surface polishings of titanium and titanium molybdenum implants on soft tissue reactions in vivo, with the aim to prevent direct soft tissue adhesion. Using a nonfracture model, to allow for study of the soft-tissue-implant surface interactions only, six surface variants of the same plate design were implanted onto the tibia of 24 New Zealand white rabbits and left in situ for 12 weeks. Results indicate that paste polished commercially pure titanium and titanium molybdenum alloy had the least soft tissue adhesion, with the concomitant development of a soft tissue capsule. Surface topography did not appear influence the thickness of the connective tissue surrounding the plate. Therefore, suitable surface polishing could be applied to plates for clinical use, where free gliding of tissues is required.


Subject(s)
Alloys , Bone Substitutes , Materials Testing , Tendons/metabolism , Titanium , Animals , Female , Inflammation/etiology , Inflammation/metabolism , Inflammation/pathology , Rabbits , Surface Properties , Tendons/pathology , Tibia/injuries , Tibia/metabolism , Tibia/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...