Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Heliyon ; 10(3): e25275, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38322882

ABSTRACT

Tissue engineering has not been widely adopted in clinical settings for several reasons, including technical challenges, high costs, and regulatory complexity. Here, we introduce the Perioperative Layered Autologous Tissue Expansion graft (PLATE graft), a composite biomaterial and collagen-reinforced construct with autologous epithelium on one side and smooth muscle tissue on the other. Designed to mimic the structure and function of natural hollow organs, the PLATE graft is unique in that it can be produced in a standard operating theatre and is cost-effective. In this proof-of-principle study, we test its regenerative performance in eight different organs, present biomechanical and permeability tests, and finally explore its in vivo performance in live rabbits.

2.
Sci Rep ; 13(1): 15584, 2023 09 20.
Article in English | MEDLINE | ID: mdl-37730755

ABSTRACT

Urogenital reconstructive surgery can be impeded by lack of tissue. Further developments within the discipline of tissue engineering may be part of a solution to improve clinical outcomes. In this study, we aimed to design an accessible and easily assembled tubular graft with autologous tissue, which could be constructed and implanted as a single-staged surgical procedure within the premises of an ordinary operating room. The ultimate goals would be to optimize current treatment-options for long-term urinary diversion. Therefore, we evaluated the optimal composition of a collagen-based scaffold with urothelial micrografts in vitro, and followingly implanted the construct in vivo as a bladder conduit. The scaffold was evaluated in relation to cell regeneration, permeability, and biomechanical properties. After establishing an optimized scaffold in vitro, consisting of high-density collagen with submerged autologous micrografts and reinforced with a mesh and stent, the construct was successfully implanted in an in vivo minipig model. The construct assemblance and surgical implantation proved feasible within the timeframe of a routine surgical intervention, and the animal quickly recovered postoperatively. Three weeks post-implantation, the conduit demonstrated good host-integration with a multilayered luminal urothelium. Our findings have encouraged us to support its use in more extensive preclinical large-animal studies.


Subject(s)
Plastic Surgery Procedures , Urothelium , Animals , Swine , Swine, Miniature , Urogenital System , Embryo Implantation
3.
Sci Rep ; 13(1): 13589, 2023 08 21.
Article in English | MEDLINE | ID: mdl-37604899

ABSTRACT

Autologous micrografting is a technique currently applied within skin wound healing, however, the potential use for surgical correction of other organs with epithelial lining, including the urinary bladder, remains largely unexplored. Currently, little is known about the micrograft expansion potential and the micromolecular events that occur in micrografted urothelial cells. In this study, we aimed to evaluate the proliferative potential of different porcine urothelial micrograft sizes in vitro, and, furthermore, to explore how urothelial micrografts communicate and which microcellular events are triggered. We demonstrated that increased tissue fragmentation subsequently potentiated the yield of proliferative cells and the cellular expansion potential, which confirms, that the micrografting principles of skin epithelium also apply to uroepithelium. Furthermore, we targeted the expression of the extracellular signal-regulated kinase (ERK) pathway and demonstrated that ERK activation occurred predominately at the micrograft borders and that ERK inhibition led to decreased urothelial migration and proliferation. Finally, we successfully isolated extracellular vesicles from the micrograft culture medium and evaluated their contents and relevance within various enriched biological processes. Our findings substantiate the potential of applying urothelial micrografting in future tissue-engineering models for reconstructive urological surgery, and, furthermore, highlights certain mechanisms as potential targets for future wound healing treatments.


Subject(s)
Communication , Extracellular Vesicles , Animals , Swine , Epithelial Cells , Urothelium , Cell Proliferation , Extracellular Signal-Regulated MAP Kinases
4.
Int J Mol Sci ; 23(20)2022 Oct 21.
Article in English | MEDLINE | ID: mdl-36293558

ABSTRACT

In severe malformations with a lack of native tissues, treatment options are limited. We aimed at expanding tissue in vivo using the body as a bioreactor and developing a sustainable single-staged procedure for autologous tissue reconstruction in malformation surgery. Autologous micro-epithelium from skin was integrated with plastically compressed collagen and a degradable knitted fabric mesh. Sixty-three scaffolds were implanted in nine rats for histological and mechanical analyses, up to 4 weeks after transplantation. Tissue integration, cell expansion, proliferation, inflammation, strength, and elasticity were evaluated over time in vivo and validated in vitro in a bladder wound healing model. After 5 days in vivo, we observed keratinocyte proliferation on top of the transplant, remodeling of the collagen, and neovascularization within the transplant. At 4 weeks, all transplants were fully integrated with the surrounding tissue. Tensile strength and elasticity were retained during the whole study period. In the in vitro models, a multilayered epithelium covered the defect after 4 weeks. Autologous micro-epithelial transplants allowed for cell expansion and reorganization in vivo without conventional pre-operative in vitro cell propagation. The method was easy to perform and did not require handling outside the operating theater.


Subject(s)
Rodentia , Tissue Engineering , Rats , Animals , Tissue Engineering/methods , Collagen , Tensile Strength , Transplantation, Autologous , Tissue Scaffolds
5.
Front Pediatr ; 10: 908554, 2022.
Article in English | MEDLINE | ID: mdl-35685916

ABSTRACT

Introduction: Appendicovesicostomy (APV) is the preferred choice of continent catheterizable channels in pediatric urology. The introduction of robot-assisted laparoscopic techniques has been correlated to superior cosmesis and convalescence and is now increasingly implemented for APV procedures. We aimed to perform a systematic review of the literature comparing open vs. robotic APV regarding possible differences in postoperative outcomes and to evaluate these findings with our own initial experiences with robotic APV compared to our previous open procedures. Methods: We evaluated the first five patients undergoing robotic APV at our institution and compared 1-year outcomes with a consecutive series of 12 patients undergoing open APV. In a systematic literature review, we screened studies from PubMed, EMBASE, and CENTRAL comparing open and robotic APV in pediatric urology (current to December 2021) and performed meta-analyses on postoperative outcomes comparing the two groups and evaluated the grade of evidence. Results: We found significantly shortened postoperative length of stay in the robotic group (p = 0.001) and comparable 1-year complication rates in robotic vs. open APV patients. We systematically screened 3,204 studies and ultimately included three non-randomized studies comparing postoperative outcomes of robotic and open APV for quantitative analysis. The open and robotic approaches performed equally well regarding overall postoperative complications, surgical reintervention, and stomal stenosis. Two of the included studies reported comparable stomal continence rates and shortened postoperative length of stay in the robotic group, in agreement with the findings in our own series. Conclusion: Robotic APV is equally safe to the conventional open approach with additional advantages in postoperative hospitalization length.

6.
Adv Healthc Mater ; 11(1): e2100684, 2022 01.
Article in English | MEDLINE | ID: mdl-34734500

ABSTRACT

Metastatic cancer spread is responsible for most cancer-related deaths. To colonize a new organ, invading cells adapt to, and remodel, the local extracellular matrix (ECM), a network of proteins and proteoglycans underpinning all tissues, and a critical regulator of homeostasis and disease. However, there is a major lack in tools to study cancer cell behavior within native 3D ECM. Here, an in-house designed bioreactor, where mouse organ ECM scaffolds are perfused and populated with cells that are challenged to colonize it, is presented. Using a specialized bioreactor chamber, it is possible to monitor cell behavior microscopically (e.g., proliferation, migration) within the organ scaffold. Cancer cells in this system recapitulate cell signaling observed in vivo and remodel complex native ECM. Moreover, the bioreactors are compatible with co-culturing cell types of different genetic origin comprising the normal and tumor microenvironment. This degree of experimental flexibility in an organ-specific and 3D context, opens new possibilities to study cell-cell and cell-ECM interplay and to model diseases in a controllable organ-specific system ex vivo.


Subject(s)
Extracellular Matrix , Tissue Scaffolds , Animals , Bioreactors , Mice , Perfusion , Proteoglycans , Tissue Engineering
7.
Sci Rep ; 11(1): 21881, 2021 11 08.
Article in English | MEDLINE | ID: mdl-34750474

ABSTRACT

Urinary bladder wound healing relies on multiple biological events that are finely tuned in a spatial-temporal manner. MicroRNAs are small non-coding RNA molecules with regulatory functions. We hypothesized that microRNAs are important molecules in the coordination of normal urinary bladder wound healing. We aimed at identifying microRNAs expressed during bladder wound healing using Affymetrix global array for microRNA profiling of the rodent urinary bladder during healing of a surgically created wound. Results were validated in the rat bladders by real-time PCR (RT-PCR) using three of the differentially expressed (DE) microRNAs. The model was thereafter validated in human cells, by measuring the expression of eight of the DE microRNAs upon in vitro wound-healing assays in primary urothelial cells. Our results indicated that 508 (40%) of all rodent microRNAs were expressed in the urinary bladder during wound healing. Thirteen of these microRNAs (1%) were DE (false discovery rate (FDR) < 0.05, P < 0.05, |logfold|> 0.25) in wounded compared to non-wounded bladders. Bioinformatic analyses helped us to identify target molecules for the DE microRNAs, and biological pathways involved in tissue repair. All data are made available in an open-access database for other researchers to explore.


Subject(s)
MicroRNAs/genetics , Urinary Bladder/injuries , Urinary Bladder/metabolism , Wound Healing/genetics , Algorithms , Animals , Cells, Cultured , Databases, Nucleic Acid , Disease Models, Animal , Gene Expression Profiling , Humans , In Vitro Techniques , Male , MicroRNAs/metabolism , Oligonucleotide Array Sequence Analysis , Rats , Rats, Sprague-Dawley , Real-Time Polymerase Chain Reaction , Tissue Engineering , Urothelium/cytology , Urothelium/physiology , Wound Healing/physiology
8.
J Vis Exp ; (171)2021 05 30.
Article in English | MEDLINE | ID: mdl-34125099

ABSTRACT

We present here a decellularization protocol for mouse heart and lungs. It produces structural ECM scaffolds that can be used to analyze ECM topology and composition. It is based on a microsurgical procedure designed to catheterize the trachea and aorta of a euthanized mouse to perfuse the heart and lungs with decellularizing agents. The decellularized cardiopulmonary complex can subsequently be immunostained to reveal the location of structural ECM proteins. The whole procedure can be completed in 4 days. The ECM scaffolds resulting from this protocol are free of dimensional distortions. The absence of cells enables structural examination of ECM structures down to submicron resolution in 3D. This protocol can be applied to healthy and diseased tissue from mice as young as 4-weeks old, including mouse models of fibrosis and cancer, opening the way to determine ECM remodeling associated with cardiopulmonary disease.


Subject(s)
Heart , Lung , Animals , Extracellular Matrix , Mice , Tissue Engineering , Tissue Scaffolds
11.
Nat Protoc ; 14(12): 3395-3425, 2019 12.
Article in English | MEDLINE | ID: mdl-31705125

ABSTRACT

The extracellular matrix (ECM) is a major regulator of homeostasis and disease, yet the 3D structure of the ECM remains poorly understood because of limitations in ECM visualization. We recently developed an ECM-specialized method termed in situ decellularization of tissues (ISDoT) to isolate native 3D ECM scaffolds from whole organs in which ECM structure and composition are preserved. Here, we present detailed surgical instructions to facilitate decellularization of 33 different mouse tissues and details of validated antibodies that enable the visualization of 35 mouse ECM proteins. Through mapping of these ECM proteins, the structure of the ECM can be determined and tissue structures visualized in detail. In this study, perfusion decellularization is presented for bones, skeletal muscle, tongue, salivary glands, stomach, duodenum, jejunum/ileum, large intestines, mesentery, liver, gallbladder, pancreas, trachea, bronchi, lungs, kidneys, urinary bladder, ovaries, uterine horn, cervix, adrenal gland, heart, arteries, veins, capillaries, lymph nodes, spleen, peripheral nerves, eye, outer ear, mammary glands, skin, and subcutaneous tissue. Decellularization, immunostaining, and imaging take 4-5 d.


Subject(s)
Extracellular Matrix/metabolism , Imaging, Three-Dimensional/methods , Staining and Labeling/methods , Animals , Antibodies/metabolism , Extracellular Matrix/physiology , Mice , Mice, Inbred BALB C , Mice, Inbred C57BL , Organ Specificity , Perfusion/methods , Tissue Engineering/methods , Tissue Scaffolds/chemistry
12.
Sci Rep ; 7(1): 5534, 2017 07 17.
Article in English | MEDLINE | ID: mdl-28717194

ABSTRACT

The development of human liver scaffolds retaining their 3-dimensional structure and extra-cellular matrix (ECM) composition is essential for the advancement of liver tissue engineering. We report the design and validation of a new methodology for the rapid and accurate production of human acellular liver tissue cubes (ALTCs) using normal liver tissue unsuitable for transplantation. The application of high shear stress is a key methodological determinant accelerating the process of tissue decellularization while maintaining ECM protein composition, 3D-architecture and physico-chemical properties of the native tissue. ALTCs were engineered with human parenchymal and non-parenchymal liver cell lines (HepG2 and LX2 cells, respectively), human umbilical vein endothelial cells (HUVEC), as well as primary human hepatocytes and hepatic stellate cells. Both parenchymal and non-parenchymal liver cells grown in ALTCs exhibited markedly different gene expression when compared to standard 2D cell cultures. Remarkably, HUVEC cells naturally migrated in the ECM scaffold and spontaneously repopulated the lining of decellularized vessels. The metabolic function and protein synthesis of engineered liver scaffolds with human primary hepatocytes reseeded under dynamic conditions were maintained. These results provide a solid basis for the establishment of effective protocols aimed at recreating human liver tissue in vitro.


Subject(s)
Cell Culture Techniques/methods , Hepatocytes/cytology , Tissue Engineering , Tissue Scaffolds/chemistry , Cell Movement , Cells, Cultured , Extracellular Matrix/chemistry , Extracellular Matrix/metabolism , Hepatic Stellate Cells/cytology , Hepatic Stellate Cells/pathology , Hepatocytes/pathology , Human Umbilical Vein Endothelial Cells , Humans , Microscopy, Electron, Scanning , Shear Strength
SELECTION OF CITATIONS
SEARCH DETAIL
...