1.
Radiol Bras ; 56(3): 137-144, 2023.
Article in English | MEDLINE | ID: mdl-37564075

ABSTRACT

Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.


Objetivo: Desenvolver corregistro automático e testar seu desempenho com ou sem marcador fiducial em imagens de tomografia computadorizada de emissão de fóton único (SPECT). Materiais e Métodos: Três SPECT/CTs foram adquiridas para cada rotação de um simulador de Jaszczak em relação ao eixo da maca (0°, 5° e 10°), com e sem fiducial. Dois métodos de corregistro inelástico foram aplicados - SPM12 e NMDose-coreg -, e a porcentagem do erro quadrático médio (%RMSE) foi usada para analisar a qualidade do corregistro. Uniformidade, contraste e resolução foram medidos antes e após o corregistro. NMDose com corregistro automático foi usado para calcular a dose renal de 12 pacientes tratados com 177Lu-DOTATATE e comparado com OLINDA/EXM. Resultados: A marcação fiducial não modificou a qualidade do corregistro das imagens SPECT, medida pela %RMSE (p = 0,40). Não houve impacto na uniformidade, contraste e resolução após o corregistro de imagens adquiridas com ou sem fiduciais. Aplicação clínica preliminar mostrou tempo total de processamento de 9 ± 3 min/paciente para NMDose e 64 ± 10 min/paciente para OLINDA/EXM, com alta correlação entre ambos, apesar de menor dose renal em NMDose. Conclusão: NMDose-coreg permite o corregistro rápido de imagens SPECT, sem perda de uniformidade, contraste ou resolução. O uso da marcação fiducial não aumentou a precisão do corregistro em fantomas.

2.
Radiol. bras ; 56(3): 137-144, May-June 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1449034

ABSTRACT

Abstract Objective: To develop an automated co-registration system and test its performance, with and without a fiducial marker, on single-photon emission computed tomography (SPECT) images. Materials and Methods: Three SPECT/CT scans were acquired for each rotation of a Jaszczak phantom (to 0°, 5°, and 10° in relation to the bed axis), with and without a fiducial marker. Two rigid co-registration software packages-SPM12 and NMDose-coreg-were employed, and the percent root mean square error (%RMSE) was calculated in order to assess the quality of the co-registrations. Uniformity, contrast, and resolution were measured before and after co-registration. The NMDose-coreg software was employed to calculate the renal doses in 12 patients treated with 177Lu-DOTATATE, and we compared those with the values obtained with the Organ Level INternal Dose Assessment for EXponential Modeling (OLINDA/EXM) software. Results: The use of a fiducial marker had no significant effect on the quality of co-registration on SPECT images, as measured by %RMSE (p = 0.40). After co-registration, uniformity, contrast, and resolution did not differ between the images acquired with fiducial markers and those acquired without. Preliminary clinical application showed mean total processing times of 9 ± 3 min/patient for NMDose-coreg and 64 ± 10 min/patient for OLINDA/EXM, with a strong correlation between the two, despite the lower renal doses obtained with NMDose-coreg. Conclusion: The use of NMDose-coreg allows fast co-registration of SPECT images, with no loss of uniformity, contrast, or resolution. The use of a fiducial marker does not appear to increase the accuracy of co-registration on phantoms.


Resumo Objetivo: Desenvolver corregistro automático e testar seu desempenho com ou sem marcador fiducial em imagens de tomografia computadorizada de emissão de fóton único (SPECT). Materiais e Métodos: Três SPECT/CTs foram adquiridas para cada rotação de um simulador de Jaszczak em relação ao eixo da maca (0°, 5° e 10°), com e sem fiducial. Dois métodos de corregistro inelástico foram aplicados - SPM12 e NMDose-coreg -, e a porcentagem do erro quadrático médio (%RMSE) foi usada para analisar a qualidade do corregistro. Uniformidade, contraste e resolução foram medidos antes e após o corregistro. NMDose com corregistro automático foi usado para calcular a dose renal de 12 pacientes tratados com 177Lu-DOTATATE e comparado com OLINDA/EXM. Resultados: A marcação fiducial não modificou a qualidade do corregistro das imagens SPECT, medida pela %RMSE (p = 0,40). Não houve impacto na uniformidade, contraste e resolução após o corregistro de imagens adquiridas com ou sem fiduciais. Aplicação clínica preliminar mostrou tempo total de processamento de 9 ± 3 min/paciente para NMDose e 64 ± 10 min/paciente para OLINDA/EXM, com alta correlação entre ambos, apesar de menor dose renal em NMDose. Conclusão: NMDose-coreg permite o corregistro rápido de imagens SPECT, sem perda de uniformidade, contraste ou resolução. O uso da marcação fiducial não aumentou a precisão do corregistro em fantomas.

3.
Nucl Med Commun ; 44(7): 596-603, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37068008

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate how statistical fluctuation in single-photon emission computed tomography (SPECT) images propagate to absorbed dose maps. METHODS: SPECT/computed tomography (CT) images of iodine-131 filled phantoms, using different acquisition and processing protocols, were evaluated using STRATOS software to assess the absorbed dose distribution at the voxel level. Absorbed dose values and coefficient of variation (COV) were analyzed for dosimetry based on single time-point SPECT images and time-integrated activities of SPECT sequences with low and high counts. RESULTS: Considering dosimetry based on a single time-point, the mean absorbed dose was not significantly affected by total counts or reconstruction parameters, but the uniformity of the absorbed dose maps had an almost linear correlation with SPECT noise. When high- and low-count SPECT sequences were used to generate an absorbed dose map, the absorbed dose COV for each of the temporal sequences was slightly lower than the absorbed dose COV based on the single SPECT image with the highest count included in the sequence. CONCLUSION: The impact of changes in SPECT counts and reconstruction parameters is almost linear when dosimetry is based on isolated SPECT images, but less pronounced when dosimetry is based on sequential SPECTs.


Subject(s)
Radiometry , Tomography, Emission-Computed, Single-Photon , Tomography, Emission-Computed, Single-Photon/methods , Radiometry/methods , Single Photon Emission Computed Tomography Computed Tomography , Iodine Radioisotopes , Software , Phantoms, Imaging
4.
Radiol Bras ; 56(1): 13-20, 2023.
Article in English | MEDLINE | ID: mdl-36926359

ABSTRACT

Objective: To measure the potential radiation dose emitted by patients who have recently undergone diagnostic nuclear medicine procedures, in order to establish optimal radiation safety measures for such procedures. Materials and Methods: We evaluated the radiation doses emitted by 175 adult patients in whom technetium-99m, iodine-131, and fluorine-18 radionuclides were administered for bone, kidney, heart, brain, and whole-body scans, as measured with a radiation detector. Those values served as the basis for evaluating whole-body radiopharmaceutical clearance, as well as the risk for the exposure of others to radiation, depending on the time elapsed since administration of the radiopharmaceutical. Results: The mean time to clearance of the radiopharmaceuticals administered, expressed as the effective half-life, ranged from 1.18 ± 0.30 h to 11.41 ± 0.02 h, and the mean maximum cumulative radiation dose at 1.0 m from the patients was 149.74 ± 56.72 µSv. Even at a distance of 0.5 m, the cumulative dose was found to be only half and one tenth of the limits established for exposure of the general public and family members/caregivers (1.0 mSv and 5.0 mSv per episode, respectively). Conclusion: Cumulative radiation doses emitted by patients immediately after diagnostic nuclear medicine procedures are considerably lower than the limits established by the International Commission on Radiological Protection and the International Atomic Energy Agency, and precautionary measures to avoid radiation exposure are therefore not required after such procedures.


Objetivo: O objetivo deste trabalho foi levantar o potencial de dose de radiação emitida por pacientes em procedimentos diagnósticos, visando a estabelecer cuidados de radioproteção mais otimizados. Materiais e Métodos: Taxas de dose de radiação emitidas por 175 pacientes administrados com os radionuclídeos 99mTc, 131I e 18F para cintilografias óssea, renal, cardíaca, cerebral e corpo inteiro, foram mensuradas com um detector de radiação, servindo para avaliar o clareamento do radiofármaco no organismo e risco de exposição após administração dos radiofármacos. Resultados: O clareamento, representado pela meia-vida efetiva, variou de 1,18 ± 0,30 h até 11,41 ± 0,02 h e a dose de radiação máxima acumulada oferecida pelos pacientes a 1,0 m foi de 149,74 ± 56,72 µSv. Mesmo para distâncias de 0,5 m, as doses estimadas foram, respectivamente, duas e dez vezes inferiores ao nível de restrição para o público geral (1,0 mSv) e exposição médica (5,0 mSv/episódio). Conclusão: Doses de radiação oferecidas por pacientes em procedimentos diagnósticos são inferiores aos níveis de restrição recomendados pela International Commission on Radiological Protection e International Atomic Energy Agency, e assim, cuidados de radioproteção são geralmente desnecessários.

5.
Radiol. bras ; 56(1): 13-20, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1422524

ABSTRACT

Abstract Objective: To measure the potential radiation dose emitted by patients who have recently undergone diagnostic nuclear medicine procedures, in order to establish optimal radiation safety measures for such procedures. Materials and Methods: We evaluated the radiation doses emitted by 175 adult patients in whom technetium-99m, iodine-131, and fluorine-18 radionuclides were administered for bone, kidney, heart, brain, and whole-body scans, as measured with a radiation detector. Those values served as the basis for evaluating whole-body radiopharmaceutical clearance, as well as the risk for the exposure of others to radiation, depending on the time elapsed since administration of the radiopharmaceutical. Results: The mean time to clearance of the radiopharmaceuticals administered, expressed as the effective half-life, ranged from 1.18 ± 0.30 h to 11.41 ± 0.02 h, and the mean maximum cumulative radiation dose at 1.0 m from the patients was 149.74 ± 56.72 µSv. Even at a distance of 0.5 m, the cumulative dose was found to be only half and one tenth of the limits established for exposure of the general public and family members/caregivers (1.0 mSv and 5.0 mSv per episode, respectively). Conclusion: Cumulative radiation doses emitted by patients immediately after diagnostic nuclear medicine procedures are considerably lower than the limits established by the International Commission on Radiological Protection and the International Atomic Energy Agency, and precautionary measures to avoid radiation exposure are therefore not required after such procedures.


Resumo Objetivo: O objetivo deste trabalho foi levantar o potencial de dose de radiação emitida por pacientes em procedimentos diagnósticos, visando a estabelecer cuidados de radioproteção mais otimizados. Materiais e Métodos: Taxas de dose de radiação emitidas por 175 pacientes administrados com os radionuclídeos 99mTc, 131I e 18F para cintilografias óssea, renal, cardíaca, cerebral e corpo inteiro, foram mensuradas com um detector de radiação, servindo para avaliar o clareamento do radiofármaco no organismo e risco de exposição após administração dos radiofármacos. Resultados: O clareamento, representado pela meia-vida efetiva, variou de 1,18 ± 0,30 h até 11,41 ± 0,02 h e a dose de radiação máxima acumulada oferecida pelos pacientes a 1,0 m foi de 149,74 ± 56,72 µSv. Mesmo para distâncias de 0,5 m, as doses estimadas foram, respectivamente, duas e dez vezes inferiores ao nível de restrição para o público geral (1,0 mSv) e exposição médica (5,0 mSv/episódio). Conclusão: Doses de radiação oferecidas por pacientes em procedimentos diagnósticos são inferiores aos níveis de restrição recomendados pela International Commission on Radiological Protection e International Atomic Energy Agency, e assim, cuidados de radioproteção são geralmente desnecessários.

6.
Clinics (Sao Paulo) ; 75: e1843, 2020.
Article in English | MEDLINE | ID: mdl-33084769

ABSTRACT

To systematically review and analyze the medical literature to assess ultrasonography echotexture changes in thyroid cancer patients for the detection of chronic sialadenitis caused by radioiodine therapy. METHODS: Sources were retrieved from PubMed, Scopus, EMBASE and LILACS through November 2018. All studies that assessed ultrasonographic features before 131I administration and at 12 months after 131I administration were selected. After data extraction, statistical analysis was performed by using Stata software. RESULTS: From a total of 435 studies, 4 studies involving 665 patients were considered eligible, and echotexture heterogeneity was found with a significant difference. CONCLUSIONS: Ultrasound echotexture may detect chronic sialadenitis secondary to salivary radioiodine therapy.


Subject(s)
Sialadenitis , Thyroid Neoplasms , Humans , Iodine Radioisotopes/adverse effects , Sialadenitis/diagnostic imaging , Sialadenitis/etiology , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/radiotherapy , Ultrasonography
7.
J Ultrasound Med ; 39(9): 1811-1818, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32309884

ABSTRACT

OBJECTIVES: This study aimed to evaluate the echo texture of the parotid salivary glands before and after radioiodine therapy (RIT) using ultrasound (US) images in patients with differentiated thyroid cancer and to evaluate the correlations between post-RIT whole-body scintigraphy (WBS) images and US image patterns in salivary and cervical areas. METHODS: A retrospective study was performed with data on demographic and clinical information, US examinations, and WBS images collected through medical recordings. RESULTS: Comparing the US features before and after RIT, significant echo texture heterogeneity was found in 31.3% of all patients evaluated. When evaluated according to the level of iodine 131 (I-131) radioactivity (<5.6, 5.6-<9.3, and ≥9.3 GBq), echo texture heterogeneity was significantly associated with the 5.6-GBq I-131 radioactivity group (P < .001). No association was found for any level of I-131 post-RIT WBS uptake intensity and changes in US feature patterns. CONCLUSIONS: Ultrasound may be a useful tool for evaluating chronic sialadenitis after RIT, and the I-131 uptake intensity using a routine post-RIT WBS is not associated with US echo texture changes.


Subject(s)
Iodine Radioisotopes , Thyroid Neoplasms , Humans , Iodine Radioisotopes/therapeutic use , Radionuclide Imaging , Retrospective Studies , Salivary Glands/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/radiotherapy
8.
Clinics ; 75: e1843, 2020. tab, graf
Article in English | LILACS | ID: biblio-1133446

ABSTRACT

To systematically review and analyze the medical literature to assess ultrasonography echotexture changes in thyroid cancer patients for the detection of chronic sialadenitis caused by radioiodine therapy. Methods: Sources were retrieved from PubMed, Scopus, EMBASE and LILACS through November 2018. All studies that assessed ultrasonographic features before 131I administration and at 12 months after 131I administration were selected. After data extraction, statistical analysis was performed by using Stata software. Results: From a total of 435 studies, 4 studies involving 665 patients were considered eligible, and echotexture heterogeneity was found with a significant difference. Conclusions: Ultrasound echotexture may detect chronic sialadenitis secondary to salivary radioiodine therapy.


Subject(s)
Humans , Sialadenitis/etiology , Sialadenitis/diagnostic imaging , Thyroid Neoplasms/radiotherapy , Thyroid Neoplasms/diagnostic imaging , Ultrasonography , Iodine Radioisotopes/adverse effects
9.
Clinics (Sao Paulo) ; 74: e835, 2019.
Article in English | MEDLINE | ID: mdl-31365617

ABSTRACT

The efficacy and toxicity of radionuclide therapy are believed to be directly related to the radiation doses received by target tissues; however, nuclear medicine therapy continues to be based primarily on the administration of empirical activities to patients and less frequently on the use of internal dosimetry for individual therapeutic planning. This review aimed to critically describe the techniques and clinical evidence of dosimetry as a tool for therapeutic planning and the main limitations to its implementation in clinical practice. The present article is a nonsystematic review of voxel-based dosimetry. Clinical evidence pointing to a correlation between the radiation dose and therapeutic response in various diseases, such as thyroid carcinoma, neuroendocrine tumors and prostate cancer, is reviewed. Its limitations include technical aspects related to image acquisition and processing and the lack of randomized clinical trials demonstrating the impact of dosimetry on patient therapy. A more widespread use of dosimetry in therapeutic planning involves the development of user-friendly dosimetric protocols and confirmation that dose estimation implies good efficacy and low treatment-related toxicity.


Subject(s)
Radioisotopes/administration & dosage , Radiometry/methods , Radionuclide Imaging/methods , Radiotherapy/methods , Humans , Positron-Emission Tomography/methods , Time Factors , Tomography, Emission-Computed, Single-Photon/methods
10.
Clinics ; 74: e835, 2019. tab, graf
Article in English | LILACS | ID: biblio-1011902

ABSTRACT

The efficacy and toxicity of radionuclide therapy are believed to be directly related to the radiation doses received by target tissues; however, nuclear medicine therapy continues to be based primarily on the administration of empirical activities to patients and less frequently on the use of internal dosimetry for individual therapeutic planning. This review aimed to critically describe the techniques and clinical evidence of dosimetry as a tool for therapeutic planning and the main limitations to its implementation in clinical practice. The present article is a nonsystematic review of voxel-based dosimetry. Clinical evidence pointing to a correlation between the radiation dose and therapeutic response in various diseases, such as thyroid carcinoma, neuroendocrine tumors and prostate cancer, is reviewed. Its limitations include technical aspects related to image acquisition and processing and the lack of randomized clinical trials demonstrating the impact of dosimetry on patient therapy. A more widespread use of dosimetry in therapeutic planning involves the development of user-friendly dosimetric protocols and confirmation that dose estimation implies good efficacy and low treatment-related toxicity.


Subject(s)
Humans , Radioisotopes/administration & dosage , Radiometry/methods , Radiotherapy/methods , Radionuclide Imaging/methods , Time Factors , Tomography, Emission-Computed, Single-Photon/methods , Positron-Emission Tomography/methods
11.
Clin Nucl Med ; 43(8): 572-578, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29916922

ABSTRACT

PURPOSE: I-metaiodobenzylguanidine (I-MIBG) has been used in the diagnosis and therapy of neuroblastoma in adult and pediatric patients for many years. In this study, we evaluated whole-body I-MIBG clearance and radiation doses received by patients, family caregivers, and medical staff to establish appropriate radiation safety measures to be used in therapy applications. METHODS: Research was focused on 23 children and adolescents with metastatic neuroblastoma, with ages ranging from 1.8 to 13 years, being treated with I-MIBG. Based on measured external dose rates from patients, dosimetric data to patients, family members, and others were calculated. RESULTS: The mean ± SD I-MIBG activity administered was 8.55 ± 1.69 GBq. Percent whole-body retention rates of I-MIBG at 24, 48, and 72 hours after administration were 48% ± 7%, 23% ± 7%, and 12% ± 6%, with a whole-body I-MIBG effective half-life of 23 ± 5 hours for all patients. The mean doses for patients were 0.234 ± 0.096 mGy·MBq to red-marrow and 0.251 ± 0.101 mGy·MBq to whole body. The maximum potential radiation doses transmitted by patients to others at 1.0 m was estimated to be 11.9 ± 3.4 mSv, with 97% of this dose occurring over 120 hours after therapy administration. Measured mean dose received by the 22 family caregivers was 1.88 ± 1.85 mSv, and that received by the 19 pediatric physicians was 43 ± 51 µSv. CONCLUSION: In this study, we evaluated the whole-body clearance of I-MIBG in 23 pediatric patients, and the radiation doses received by family caregivers and medical staff during these therapy procedures, thus facilitating the establishment of radiation safety measures to be applied in pediatric therapy.


Subject(s)
3-Iodobenzylguanidine/therapeutic use , Brain Neoplasms/radiotherapy , Metabolic Clearance Rate , Neuroblastoma/radiotherapy , Radiation Dosage , Radiopharmaceuticals/therapeutic use , 3-Iodobenzylguanidine/administration & dosage , 3-Iodobenzylguanidine/pharmacokinetics , Adolescent , Adult , Caregivers , Child , Child, Preschool , Female , Humans , Infant , Male , Medical Staff , Radiation Injuries/prevention & control , Radiopharmaceuticals/administration & dosage , Radiopharmaceuticals/pharmacokinetics , Radiotherapy Dosage , Safety
12.
Radiol Bras ; 49(3): 150-7, 2016.
Article in English | MEDLINE | ID: mdl-27403014

ABSTRACT

OBJECTIVE: To compare the probe detection method with the image quantification method when estimating (131)I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. MATERIALS AND METHODS: Fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of (131)I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after (131)I administration in order to estimate the effective half-life (Teff) and residence time of (131)I in the body. RESULTS: The mean values for Teff and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the Teff (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after (131)I administration (p > 0.914). CONCLUSION: There is full agreement as to the feasibility of using probe detection and image quantification when estimating (131)I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is inefficacious in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of (131)I to be administered to patients under such therapy, it should be used with caution.


OBJETIVO: Comparar o desempenho dos métodos de detecção de sonda e quantificação de imagens na estimativa da biocinética do radioisótopo 131I e das doses de radiação na medula óssea vermelha e no corpo inteiro durante a radioiodoterapia em pacientes com câncer de tireoide. MATERIAIS E MÉTODOS: Catorze pacientes portadores de câncer metastático de tireoide, sem acometimento ósseo, foram submetidos ao planejamento terapêutico visando estabelecer a melhor atividade de 131I a ser empregada na radioiodoterapia. Imagens cintilográficas e captações de corpo inteiro foram adquiridas 4, 24, 48, 72 e 96 h após a administração de atividades traçadoras de 131I, visando estimar a meia-vida efetiva (T1/2ef) e o tempo de residência do 131I no organismo dos pacientes. RESULTADOS: Os valores médios de T1/2ef e tempo de residência foram, respectivamente, 19 ± 9 h e 28 ± 12 h pelo método de detecção de sonda e 20 ± 13 h e 29 ± 18 h pela quantificação de imagens. As doses médias na medula óssea vermelha e no corpo inteiro foram, respectivamente, 0,061 ± 0,041 mGy/MBq e 0,073 ± 0,040 mGy/MBq pelo método de detecção de sonda e 0,066 ± 0,055 mGy/MBq e 0,078 ± 0,056 mGy/MBq pela quantificação de imagens. A análise estatística demonstrou que os dois métodos apresentam desempenho semelhante no tocante à estimativa de T1/2ef (p = 0,801), tempo de residência (p = 0,801) e doses, tanto na medula óssea vermelha (p = 0,708) como no corpo inteiro (p = 0,811), mesmo com métodos otimizados de dosimetria que levam em consideração somente dois pontos de medida (4 h e 96 h) após a administração de 131I (p > 0,914). CONCLUSÃO: Existe excelente concordância entre o método de detecção de sonda e a quantificação de imagens quanto à estimativa da biocinética do 131I e das doses absorvidas de radiação. Contudo, o método de detecção de sonda deve ser usado com cuidado por ser incapaz de identificar regiões metastáticas e órgãos críticos durante a terapia com radionuclídeos, podendo distorcer ajustes da atividade de 131I a ser administrada durante a radioiodoterapia.

13.
Radiol. bras ; 49(3): 150-157, tab, graf
Article in English | LILACS | ID: lil-787599

ABSTRACT

Abstract Objective: To compare the probe detection method with the image quantification method when estimating 131I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and Methods: Fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of 131I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after 131I administration in order to estimate the effective half-life (Teff) and residence time of 131I in the body. Results: The mean values for Teff and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the Teff (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after 131I administration (p > 0.914). Conclusion: There is full agreement as to the feasibility of using probe detection and image quantification when estimating 131I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is inefficacious in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of 131I to be administered to patients under such therapy, it should be used with caution.


Resumo Objetivo: Comparar o desempenho dos métodos de detecção de sonda e quantificação de imagens na estimativa da biocinética do radioisótopo 131I e das doses de radiação na medula óssea vermelha e no corpo inteiro durante a radioiodoterapia em pacientes com câncer de tireoide. Materiais e Métodos: Catorze pacientes portadores de câncer metastático de tireoide, sem acometimento ósseo, foram submetidos ao planejamento terapêutico visando estabelecer a melhor atividade de 131I a ser empregada na radioiodoterapia. Imagens cintilográficas e captações de corpo inteiro foram adquiridas 4, 24, 48, 72 e 96 h após a administração de atividades traçadoras de 131I, visando estimar a meia-vida efetiva (T1/2ef) e o tempo de residência do 131I no organismo dos pacientes. Resultados: Os valores médios de T1/2ef e tempo de residência foram, respectivamente, 19 ± 9 h e 28 ± 12 h pelo método de detecção de sonda e 20 ± 13 h e 29 ± 18 h pela quantificação de imagens. As doses médias na medula óssea vermelha e no corpo inteiro foram, respectivamente, 0,061 ± 0,041 mGy/MBq e 0,073 ± 0,040 mGy/MBq pelo método de detecção de sonda e 0,066 ± 0,055 mGy/MBq e 0,078 ± 0,056 mGy/MBq pela quantificação de imagens. A análise estatística demonstrou que os dois métodos apresentam desempenho semelhante no tocante à estimativa de T1/2ef (p = 0,801), tempo de residência (p = 0,801) e doses, tanto na medula óssea vermelha (p = 0,708) como no corpo inteiro (p = 0,811), mesmo com métodos otimizados de dosimetria que levam em consideração somente dois pontos de medida (4 h e 96 h) após a administração de 131I (p > 0,914). Conclusão: Existe excelente concordância entre o método de detecção de sonda e a quantificação de imagens quanto à estimativa da biocinética do 131I e das doses absorvidas de radiação. Contudo, o método de detecção de sonda deve ser usado com cuidado por ser incapaz de identificar regiões metastáticas e órgãos críticos durante a terapia com radionuclídeos, podendo distorcer ajustes da atividade de 131I a ser administrada durante a radioiodoterapia.

14.
Nucl Med Commun ; 37(5): 525-33, 2016 May.
Article in English | MEDLINE | ID: mdl-26657219

ABSTRACT

OBJECTIVES: This study aimed to establish a concise method for determining a diagnostic reference level (DRL) for adult and pediatric nuclear medicine patients on the basis of diagnostic procedures and administered radioisotope as a means of controlling medical exposure. METHODS: A screening was carried out in all Brazilian Nuclear Medicine Service (NMS) establishments to support this study by collecting the average activities administered during adult diagnostic procedures and the rules applied to adjust these according to the patient's age and body mass. Percentile 75 was used in all the activities administered as a means of establishing DRL for adult patients, with additional correction factors for pediatric patients. Radiation doses from nuclear medicine procedures on the basis of average administered activity were calculated for all diagnostic exams. RESULTS AND DISCUSSION: A total of 107 NMSs in Brazil agreed to participate in the project. From the 64 nuclear medicine procedures studied, bone, kidney, and parathyroid scans were found to be used in more than 85% of all the NMSs analyzed. There was a large disparity among the activities administered, when applying the same procedures, this reaching, in some cases, more than 20 times between the lowest and the highest. Diagnostic exams based on Ga, Tl, and I radioisotopes proved to be the major exams administering radiation doses to patients. On introducing the DRL concept into clinical routine, the minimum reduction in radiation doses received by patients was about 15%, the maximum was 95%, and the average was 50% compared with the previously reported administered activities. CONCLUSION: Variability in the available diagnostic procedures as well as in the amount of activities administered within the same procedure was appreciable not only in Brazil, but worldwide. Global efforts are needed to establish a concise DRL that can be applied in adult and pediatric nuclear medicine procedures as the application of DRL in clinical routine has been proven to be an important tool for controlling and reducing radiation doses received by patients in medical exposure.


Subject(s)
Diagnostic Imaging/methods , Diagnostic Imaging/standards , Nuclear Medicine/methods , Nuclear Medicine/standards , Radiation Dosage , Adult , Brazil , Child , Humans , Reference Standards
15.
Nucl Med Commun ; 37(5): 473-9, 2016 May.
Article in English | MEDLINE | ID: mdl-26671852

ABSTRACT

OBJECTIVES: This study aimed to present a comparison of iodine-131 (I) biokinetics and radiation doses to red-marrow (rm) and whole-body (wb), following the administration of tracer and therapeutic activities, as a means of confirming whether I clearance and radiation doses for therapy procedures can be predicted by tracer activities. METHODS: Eleven differentiated thyroid cancer patients were followed after receiving tracer and therapeutic I activity. Whole-body I clearance was estimated using radiation detectors and OLINDA/EXM software was used to calculate radiation doses to rm and wb. RESULTS AND DISCUSSION: Tracer I activity of 86 (±14) MBq and therapeutic activity of 8.04 (±1.18) GBq were administered to patients, thereby producing an average wb I effective half-time and residence time of, respectively, 13.51 (±4.05) and 23.13 (±5.98) h for tracer activities and 13.32 (±3.38) and 19.63 (±4.77) h for therapy. Radiation doses to rm and wb were, respectively, 0.0467 (±0.0208) and 0.0589 (±0.0207) mGy/MBq in tracer studies and 0.0396 (±0.0169) and 0.0500 (±0.0163) mGy/MBq in therapy. Although the differences were not considered statistically significant between averages, those between the values of effective half-times (P=0.906), residence times (P=0.145), and radiation doses to rm (P=0.393) and to wb (P=0.272), from tracer and therapy procedures, large differences of up to 80% in wb I clearance, and up to 50% in radiation doses were observed when patients were analyzed individually, thus impacting on the total amount of I activity calculated to be safe for application in individual therapy. CONCLUSION: I biokinetics and radiation doses to rm and wb in therapy procedures are well predicted by diagnostic activities when average values of a group of patients are compared. Nonetheless, when patients are analyzed individually, significant differences may be encountered, thus implying that nuclear medicine therapy-planning requires due consideration of changes in individual patient-body status from initial tracer to final therapy procedures to thus provide appropriate adjustments in therapeutic activities.


Subject(s)
Iodine Radioisotopes/pharmacokinetics , Iodine Radioisotopes/therapeutic use , Nuclear Medicine , Radiation Dosage , Radiotherapy Planning, Computer-Assisted , Adult , Bone Marrow/radiation effects , Female , Half-Life , Humans , Kinetics , Middle Aged , Radiotherapy Dosage , Thyroid Neoplasms/metabolism , Thyroid Neoplasms/radiotherapy , Whole-Body Irradiation
16.
Thyroid ; 25(12): 1291-6, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26446582

ABSTRACT

BACKGROUND: Renal function is related to thyroid hormonal status, and glomerular filtration rate (GFR) seems to be impaired in patients with hypothyroidism. The aim of this work was to evaluate quantitatively the effect of hypothyroidism on GFR using a (51)Cr-EDTA radioisotope assay. METHODS: Twenty-eight patients without known renal disease or dysfunction who had been referred for radioiodine therapy (RIT) after total thyroidectomy were enrolled in this study and divided into two groups. Group A underwent thyroid hormone withdrawal (THW) resulting in hypothyroidism, while group B underwent recombinant human thyrotropin (rhTSH) stimulation and hence remained euthyroid. GFR was assessed by (51)Cr-EDTA before and after THW or rhTSH. RESULTS: No clinical differences were observed between the two groups. The mean ± SD GFRs were 94 ± 19 mL/min/1.73 m(2) before THW and 76 ± 16 mL/min/1.73 m(2) after THW for group A (p = 0.009), and 91 ± 18 mL/min/1.73 m(2) before rhTSH and 93 ± 15 mL/min/1.73 m(2) after rhTSH for group B (p = 0.613). The percent decrease in GFR during hypothyroidism is approximately 18-22%. CONCLUSION: GFR decreases in patients with normal kidney function during THW for RIT, and rhTSH preserves GFR in these patients. This GFR impairment following thyroidectomy is related to hypothyroidism due to a significant reduction in thyroid hormone levels and is not due to a rise in the TSH level.


Subject(s)
Carcinoma/therapy , Glomerular Filtration Rate , Hypothyroidism , Iodine Radioisotopes/therapeutic use , Thyroid Neoplasms/therapy , Thyroidectomy , Thyrotropin/therapeutic use , Thyroxine , Withholding Treatment , Adult , Chemoradiotherapy, Adjuvant , Combined Modality Therapy , Female , Humans , Male , Middle Aged , Radiotherapy, Adjuvant , Recombinant Proteins , Treatment Outcome
17.
World J Nucl Med ; 14(3): 165-70, 2015.
Article in English | MEDLINE | ID: mdl-26420986

ABSTRACT

Dose calibrator linearity testing is indispensable for evaluating the capacity of this equipment in measuring radioisotope activities at different magnitudes, a fundamental aspect of the daily routine of a nuclear medicine department, and with an impact on patient exposure. The main aims of this study were to evaluate the feasibility of substituting the radioisotope Fluorine-18 ((18)F) with Technetium-99m ((99m)Tc) in this test, and to indicate it with the lowest operational cost. The test was applied with sources of (99m)Tc (62 GBq) and (18)F (12 GBq), the activities of which were measured at different times, with the equipment preadjusted to measuring sources of (99m)Tc, (18)F, Gallium-67 ((67)Ga), and Iodine-131 ((131)I). Over time, the average deviation between measured and expected activities from (99m)Tc and (18)F were, respectively, 0.56 (±1.79)% and 0.92 (±1.19)%. The average ratios for 99(m)Tc source experimental activity, when measured with the equipment adjusted for measuring (18)F, (67)Ga, and (131)I sources, in real values, were, respectively, 3.42 (±0.06), 1.45 (±0.03), and 1.13 (±0.02), and those for the (18)F source experimental activity, measured through adjustments of (99m)Tc, (67)Ga, and (131)I, were, respectively, 0.295 (±0.004), 0.335 (±0.007), and 0.426 (±0.006). The adjustment of a simple exponential function for describing (99m)Tc and (18)F experimental activities facilitated the calculation of the physical half-lives of the radioisotopes, with a difference of about 1% in relation to the values described in the literature. Linearity test results, when using (99m)Tc, through being compatible with those acquired with (18)F, imply the possibility of using both radioisotopes during linearity testing. Nevertheless, this information, along with the high potential of exposure and the high cost of (18)F, implies that (99m)Tc should preferably be employed for linearity testing in clinics that normally use (18)F, without the risk of prejudicing either the procedure itself or the guarantee of a high-quality nuclear medicine service.

18.
Clin Nucl Med ; 40(9): 715-9, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26204202

ABSTRACT

UNLABELLED: : Therapy of Graves' hyperthyroidism (HTG) with I is still mostly performed on an empirical basis. The present study was carried out to evaluate clinical and dosimetric variables associated with outcome in HTG therapy, which could contribute to planning and defining the most appropriate activity to be administered. METHODS: Patients with HTG were randomly assigned to therapy with 555 MBq (15mci) or 1110 MBq (30 mCi) of I. Estimation of thyroid radiation absorbed dose was made according to MIRD methodology. Success was defined as clinical/laboratory euthyroidism or hypothyroidism one year after therapy. The association between clinical, laboratory, and dosimetric variables with 1-year outcome was measured using bivariate analysis, followed by logistic regression. RESULTS: Ninety-one patients included completed the follow-up. Therapeutic success was observed in 77 (84.6%) of them, in a greater proportion when 1110 MBq of I was administered as compared with 550 MBq (94.8% vs 77.4%, P = 0.02). Besides administered activity, multivariate analysis indicated that outcome was related to patient age and gland mass. A higher therapeutic success rate was achieved with doses greater than 300 Gy as compared with doses less than 300 Gy (89% vs 60%, P = 0.01). CONCLUSION: Administered activity, age, and gland mass were related to the outcome. Radiation absorbed dose, although not significant according to multivariate analysis, may be used as a quantitative parameter in therapy planning, with a target dose of 300 Gy. In cases where a rapid and efficient response to radioiodine treatment is required, adoption of a simplified protocol employing high activities is justified.


Subject(s)
Graves Disease/radiotherapy , Iodine Radioisotopes/therapeutic use , Radiation Dosage , Radiopharmaceuticals/therapeutic use , Adult , Female , Humans , Male , Middle Aged , Radiotherapy Dosage
19.
Radiol Bras ; 48(1): 26-32, 2015.
Article in English | MEDLINE | ID: mdl-25798005

ABSTRACT

OBJECTIVE: The present study was aimed at evaluating the viability of replacing (18)F with (99m)Tc in dose calibrator linearity testing. MATERIALS AND METHODS: The test was performed with sources of (99m)Tc (62 GBq) and (18)F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical (99m)Tc and (18)F sources activities were calculated and subsequently compared. RESULTS: Mean deviations between experimental and theoretical (99m)Tc and (18)F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the (99m)Tc source as measured with the equipment pre-calibrated to measure (99m)Tc and (18)F was 3.42 (± 0.06), and for the (18)F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. CONCLUSION: The results of the linearity test using (99m)Tc were compatible with those obtained with the (18)F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in (18)F acquisition suggest (99m)Tc as the element of choice to perform dose calibrator linearity tests in centers that use (18)F, without any detriment to the procedure as well as to the quality of the nuclear medicine service.


OBJETIVO: Avaliar a viabilidade de substituir o radioisótopo 18F pelo 99mTc no teste de linearidade em medidores de atividade. MATERIAIS E MÉTODOS: O teste foi realizado empregando-se fontes de 99mTc (62 GBq) e 18F (12 GBq), cujas atividades foram mensuradas até valores abaixo de 1 MBq. As razões e desvios entre as atividades experimentais e teóricas foram calculados e comparados. RESULTADOS: Os desvios médios entre as atividades experimentais e teóricas para o 99mTc e 18F foram, respectivamente, 0,56 (± 1,79)% e 0,92 (± 1,19)%. A razão média entre as atividades indicadas pelo equipamento para a fonte de 99mTc quando mensurada no equipamento pré-ajustado para medir o 99mTc e 18F foi 3,42 (± 0,06), e para o 18F este valor foi 3,39 (± 0,05), razões consideradas constantes ao longo de todo o período de medida. CONCLUSÃO: Os resultados do teste utilizando o 99mTc são compatíveis com os adquiridos com o 18F, implicando na possibilidade de utilização de ambos os radioisótopos na realização do teste de linearidade. Esta informação, aliada ao elevado potencial de exposição e custos de aquisição do 18F, sugere que o 99mTc seja empregado na realização do teste de linearidade para clínicas que utilizam 18F, sem prejuízo para o procedimento e garantia da qualidade de um serviço de medicina nuclear.

20.
Radiol. bras ; 48(1): 26-32, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741690

ABSTRACT

Objective: The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods: The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results: Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion: The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. .


Objetivo: Avaliar a viabilidade de substituir o radioisótopo 18F pelo 99mTc no teste de linearidade em medidores de atividade. Materiais e Métodos: O teste foi realizado empregando-se fontes de 99mTc (62 GBq) e 18F (12 GBq), cujas atividades foram mensuradas até valores abaixo de 1 MBq. As razões e desvios entre as atividades experimentais e teóricas foram calculados e comparados. Resultados: Os desvios médios entre as atividades experimentais e teóricas para o 99mTc e 18F foram, respectivamente, 0,56 (± 1,79)% e 0,92 (± 1,19)%. A razão média entre as atividades indicadas pelo equipamento para a fonte de 99mTc quando mensurada no equipamento pré-ajustado para medir o 99mTc e 18F foi 3,42 (± 0,06), e para o 18F este valor foi 3,39 (± 0,05), razões consideradas constantes ao longo de todo o período de medida. Conclusão: Os resultados do teste utilizando o 99mTc são compatíveis com os adquiridos com o 18F, implicando na possibilidade de utilização de ambos os radioisótopos na realização do teste de linearidade. Esta informação, aliada ao elevado potencial de exposição e custos de aquisição do 18F, sugere que o 99mTc seja empregado na realização do teste de linearidade para clínicas que utilizam 18F, sem prejuízo para o procedimento e garantia da qualidade de um serviço de medicina nuclear. .