Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Plant Biol (Stuttg) ; 26(4): 499-507, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38773740

ABSTRACT

Global crop production in agriculture depends on water availability. Future scenarios predict increasing occurrence of flash floods and rapidly developing droughts accompanied by heatwaves in humid regions that rely on rain-fed agriculture. It is challenging to maintain high crop yields, even in arid and drought-prone regions that depend on irrigation. The average water demand of crops varies significantly, depending on plant species, development stage, and climate. Most crops, such as maize and wheat, require relatively more water during the vegetative phase compared to the ripening phase. In this review, we explain WUE and options to improve water use and thus crop yield. Nutrient management might represent another possibility to manipulate water uptake and use by plants. An emerging topic involves agroforest co-cultivation, where trees in the system facilitate water transfer through hydraulic lift, benefiting neighbouring crops. Other options to enhance crop yield per water use are discussed.


Subject(s)
Crops, Agricultural , Water , Crops, Agricultural/physiology , Crops, Agricultural/growth & development , Water/metabolism , Agricultural Irrigation , Droughts , Agriculture/methods , Crop Production/methods
2.
Wear ; 4772021 Jul 18.
Article in English | MEDLINE | ID: mdl-34690379

ABSTRACT

Periprosthetic fluids often contain reactive oxygen species, including H2O2, that are generated during inflammatory processes. Here, we investigated the fretting-corrosion behavior of CoCrX-alloys (X = Mo, Fe) in a complex protein-containing lubricant, with and without the addition of H2O2. Given the known protective role of molybdenum as an alloying element in metal degradation, we considered its effects by designing a two-way factorial experiment. The aim of the study was to investigate tribocorrosive mechanisms in modular joints of knee and hip prostheses. A previously described test-rig was used to run fretting corrosion tests of CoCrX-alloys with (X=Mo) and without (X=Fe) molybdenum against TiAl6V4 in bovine calf serum (BCS) with and without a physiological relevant H2O2 level (3 mM) in gross slip mode (4 Hz, ±50 µm, pmax=0.18 GPa, 37 °C, 50,000 cycles). Two CoCr-pins were pressed against a cylindrical TiAl6V4-rod, forming a line contact. Normal and frictional forces, the displacement, and the open circuit potential (OCP) were measured and recorded continuously. The dissipated frictional work was independent of alloy composition. The addition of H2O2 lowered the dissipated frictional work and increased wear, and this was significant in the absence of Mo. The mean OCP value was lower with Mo-containing than with Mo-free alloy in both pure BCS (p = .042), and BCS ± H2O2 (p < .0005). The wear scar was deeper for the Mo-free alloy, and this was significant (p = .013) in the presence of H2O2. These findings suggest a marked weakening of the passive film in the presence of H2O2, which is mitigated by the availability of Mo.

3.
Eur Cell Mater ; 42: 122-138, 2021 08 26.
Article in English | MEDLINE | ID: mdl-34435345

ABSTRACT

Despite many preventive measures, including prophylactic antibiotics, periprosthetic joint infection (PJI) remains a devastating complication following arthroplasty, leading to pain, suffering, morbidity and substantial economic burden. Humans have a powerful innate immune system that can effectively control infections, if alerted quickly. Unfortunately, pathogens use many mechanisms to dampen innate immune responses. The study hypothesis was that immunomodulators that can jumpstart and direct innate immune responses (particularly neutrophils) at the surgical site of implant placement would boost immune responses and reduce PJI, even in the absence of antibiotics. To test this hypothesis, N-formyl-methionyl-leucyl-phenylalanine (fMLP) (a potent chemoattractant for phagocytic leukocytes including neutrophils) was used in a mouse model of PJI with Staphylococcus aureus (S. aureus). Mice receiving intramedullary femoral implants were divided into three groups: i) implant alone; ii) implant + S. aureus; iii) implant + fMLP + S. aureus. fMLP treatment reduced S. aureus infection levels by ~ 2-Log orders at day 3. Moreover, fMLP therapy reduced infection-induced peri-implant periosteal reaction, focal cortical loss and areas of inflammatory infiltrate in mice distal femora at day 10. Finally, fMLP treatment reduced pain behaviour and increased weight-bearing at the implant leg in infected mice at day 10. Data indicated that fMLP therapy is a promising novel approach for reducing PJI, if administered locally at surgical sites. Future work will be toward further enhancement and optimisation of an fMLP-based therapeutic approach through combination with antibiotics and/or implant coating with fMLP.


Subject(s)
Prosthesis-Related Infections , Staphylococcal Infections , Animals , Mice , N-Formylmethionine Leucyl-Phenylalanine , Neutrophils , Prosthesis-Related Infections/drug therapy , Prosthesis-Related Infections/prevention & control , Staphylococcal Infections/drug therapy , Staphylococcus aureus
4.
Exp Mech ; 61(7): 1069-1080, 2021 Sep.
Article in English | MEDLINE | ID: mdl-35528779

ABSTRACT

Background: Microindentation is a technique with high sensitivity and spatial resolution, allowing for measurements at small-scale indentation depths. Various methods of indentation analysis to determine output properties exist. Objective: Here, the Oliver-Pharr Method and Hertzian Method were compared for stiffness analyses of articular cartilage at varying length-scales before and after bioreactor loading. Methods: Using three different conospherical tips with varying radii (20, 100, 793.75 µm), a bioreactor-indenter workflow was performed on cartilage explants to assess changes in stiffness due to articular loading. For all data, both the Oliver-Pharr Method and Hertzian Method were applied for indentation analysis. Results: The reduced moduli calculated by the Hertzian Method were found to be similar to those of the Oliver-Pharr Method when the 20 µm tip size was used. The reduced moduli calculated using the Hertzian Method were found to be consistent across the varying length-scales, whereas for the Oliver-Pharr Method, adhesion/suction led to the largest tip exhibiting an increased average reduced modulus compared to the two smaller tips. Loading induced stiffening of articular cartilage was observed consistently, regardless of tip size or indentation analysis applied. Conclusions: Overall, geometric linearity is preserved across all tip sizes for the Hertzian Method and may be assumed for the two smaller tip sizes using the Oliver-Pharr Method. These findings further validate the previously described stiffening response of the superficial zone of cartilage after articular loading and demonstrate that the finding is length-scale independent.

5.
J Mech Behav Biomed Mater ; 113: 104117, 2021 01.
Article in English | MEDLINE | ID: mdl-33065468

ABSTRACT

Total knee arthroplasty has become a routine procedure for patients suffering from joint diseases. Although the number of operations continuously increases, a limited service-life of implants represents a persisting challenge for scientists. Understanding of lubrication may help to suitably explain tribological processes on the way to replacements that become durable well into the third decade of service. The aim of the present study is to assess the formation of protein lubricating film in the knee implant. A developed knee simulator was used to observe the contact of real femoral and transparent polymer tibial component using fluorescent microscopy. The contact was lubricated by various protein solutions with attention to the behaviour of albumin and γ-globulin. In order to suitably mimic a human synovial fluid, hyaluronic acid and phospholipids were subsequently added to the solutions. Further, the change in shape and the migration of the contact zone were studied. The results showed considerable appearance differences of the contact over the swing phase of the simplified gait cycle. Regarding film formation, a strong interaction of the various molecules of synovial fluid was observed. It was found that the thickness of the lubricating layer stabilizes within around 50 s. Throughout the contact zone, protein agglomerations were present and could be clearly visualised using the applied optical technique.


Subject(s)
Arthroplasty, Replacement, Knee , Synovial Fluid , Albumins , Humans , Knee Joint , Lubrication , gamma-Globulins
6.
Biotribology (Oxf) ; 242020 Dec.
Article in English | MEDLINE | ID: mdl-33015276

ABSTRACT

Tribocorrosion of implants has been widely addressed in the orthopedic and dental research fields. This study is a systematic scoping review about research methods that combine tribocorrosion tests with cells/tissues cultures, aimed to identify related current problems and future challenges. We used 4 different databases to identify 1022 records responding to an articulated keywords search-strategy. After removing the duplicates and the articles that didn't meet the search-criteria, we assessed 20 full-text articles for eligibility. Of the 20 eligible articles, we charted 8 records on cell cultures combined with tribocorrosion tests on implant materials (titanium, CoCrMo, and/or stainless steel). The year of publication ranged from 1991 to 2019. The cell line used was mostly murine. Two records used fretting tests, while 6 used reciprocating sliding with pin-on-disc tribometers. An electrochemical three-electrode setup was used in 4 records. We identified overall two experimental approaches: cells cultured on the metal (5 records), and cells cultured near the metal (3 records). Research activities on tribocorrosion processes in the presence of cells have been undertaken worldwide by a few groups. After a limited initial interest on this topic in the 1990's, research activities have restarted in the last decade, renewing the topic with technologically more advanced setups and analytical tools. We identified the main problems to be the lack of test reproducibility and wear particle characterization. We believe that the main challenges lay in the interdisciplinary approach, the inter-laboratory validation of experiments, and the interpretation of results, particularly in relation to potential clinical significance.

7.
J Bio Tribocorros ; 5(4)2019 Dec.
Article in English | MEDLINE | ID: mdl-31828005

ABSTRACT

The problem of wear and corrosion of CoCrMo-implant surfaces in the human body following total joint replacement has been commonly investigated with tribocorrosion tests, using different lubricants meant to simulate the pseudo-synovial fluid. While results considering the synovial fluid components separately have highlighted their individual influence on the tribological performance of CoCrMo-alloy, an understanding about the influence of the synovial fluid components under the electrochemical point of view is missing. This work aims to investigate the effect of bovine serum albumin (BSA) and hyaluronic acid (HA) on electrochemical potential variations of CoCrMo alloys tested in a model synovial fluid. To simulate the environment inside the synovial capsule, the tests were performed inside a CO2 incubator at 37°C. Open circuit potential, electrochemical impedance spectroscopy, cathodic and anodic potentiodynamic measurements were performed with different electrolytes, prepared with cell culture medium (RMPI-1640), BSA and HA. The final CoCrMo-surface was analyzed by SEM/EDS and infrared spectroscopy. The influence of HA on the corrosion of the CoCrMo-alloy depended on the presence of BSA proteins adsorbed on the CoCrMo-surface: EIS and anodic polarization results showed a corrosive action of HA in the absence of adsorbed proteins. In the presence of both BSA and HA, organometallic precipitates were found on the CoCrMo surface following reverse anodic polarization, which remind of corrosion products found in-vivo. These results indicate that HA affects the interaction of CoCrMo implant alloys with protein-containing model synovial fluids, and suggest that HA needs to be considered in tribocorrosion studies for more clinically relevant outcomes.

8.
Materialia (Oxf) ; 62019 Jun.
Article in English | MEDLINE | ID: mdl-31183460

ABSTRACT

During joint inflammation, various reactive oxygen species (ROS) are present in the surrounding tissue and joint fluid. In the laboratory, hydrogen peroxide (H2O2) is typically used to simulate inflammatory conditions, and media containing proteins and hyaluronic acid (HA) are employed to simulate joint synovial fluid. Electrochemical interactions between H2O2 and HA in the presence of a CoCrMo surface are expected, since HA molecules contain redox-active moieties. We hypothesized that any redox reactions of these moieties with ROS will mitigate the oxidizing effect of H2O2 on the CoCrMo surface, limiting the corrosion rate of the metal. Non-destructive electrochemical measurements (open circuit potential, linear polarization resistance and electrochemical impedance spectroscopy) were used to investigate the corrosion response of CoCrMo in synovial model fluid containing physiologically relevant concentrations of albumin proteins and hyaluronic acid, with and without H2O2. Two different molarities of H2O2, 3 mM and 30 mM, were tested. While both molarities are within physiological limits, 3mM is well within the range HA could mitigate, whereas 30 mM is not. Contrary to our hypothesis, HA did not alleviate corrosion in 3 mM H2O2 and even caused a corrosion increase in the case of 30 mM H2O2. The decrease in corrosion resistance of the alloy may be attributed to the complexation of degenerated HA molecular chains with chromium ions released from the metallic surface, which are necessary to build a protective oxide film. This finding has clinical implications, suggesting that HA accelerates corrosion of CoCrMo implants in the presence of strong inflammation.

9.
Biotribology (Oxf) ; 182019 Jun.
Article in English | MEDLINE | ID: mdl-30984811

ABSTRACT

Wear and corrosion in total hip replacement negatively impact implant service-life and patient well-being. The aim of this study was to generate a statistical response surface of material loss using an apparatus, capable of testing the effect of wear and corrosion products in situ on cells, such as macrophages. The test chamber of a ball-on-flat tribometer operating inside a CO2 incubator was integrated with an electrochemical setup and adapted for cell culture work. A 20-test series, following a 2-level 3-factor design of experiments, was performed with a ceramic head in reciprocating rotational motion against a CoCrMo-alloy disc, under constant load. The lubricant was cell culture medium (RPMI-1640+10vol% bovine serum). Response surfaces were generated, which statistically showed the influence of motion amplitude, load, and potential on the total mass loss and wear scar volume of the metallic discs. Potential had the highest impact on the total mass loss, while motion amplitude and load significantly influenced the wear scar volume. The concentrations of the alloy elements found in the lubricants reflected the bulk-alloy stoichiometry. The total concentration of Co released into the lubricant (2.3-63 ppm by total mass loss, 1.5 to 62 ppm by ICP-MS) corresponded well with the known range to trigger cell response. Tribocorrosion tests in the presence of cells and tissues, such as macrophages, lymphocytes and/or synovium, will be carried out in the future.

10.
Biotribology (Oxf) ; 10: 42-50, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28808674

ABSTRACT

Artificial hip joints operate in aqueous biofluids that are highly reactive towards metallic surfaces. The reactivity at the metal interface is enhanced by mechanical interaction due to friction, which can change the near-surface structure of the metal and surface chemistry. There are now several reports in the literature about the in-situ generation of reaction films and tribo-metallurgical transformations on metal-on-metal hip joints. This paper summarizes current knowledge and provides a mechanistic interpretation of the surface chemical and metallurgical phenomena. Basic concepts of corrosion and wear are illustrated and used to interpret available literature on in-vitro and in-vivo studies of metal-on-metal hip joints. Based on this review, three forms of tribomaterial, characterized by different combinations of oxide films and organic layers, can be determined. It is shown that the generation of these tribofilms can be related to specific electrochemical and mechanical phenomena in the metal interface. It is suggested that the generation of this surface reaction layer constitutes a way to minimize (mechanical) wear of MoM hip implants.

11.
Osteoarthritis Cartilage ; 23(11): 1939-45, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26521740

ABSTRACT

A major objective of this article is to examine the research implications of recently available genome-wide expression profiles of cartilage from human osteoarthritis (OA) joints. We propose that, when viewed in the light of extensive earlier work, this novel data provides a unique opportunity to reorient the design of experimental systems toward clinical relevance. Specifically, in the area of cartilage explant biology, this will require a fresh evaluation of existing paradigms, so as to optimize the choices of tissue source, cytokine/growth factor/nutrient addition, and biomechanical environment for discovery. Within this context, we firstly discuss the literature on the nature and role of potential catabolic mediators in OA pathology, including data from human OA cartilage, animal models of OA, and ex vivo studies. Secondly, due to the number and breadth of studies on IL-1ß in this area, a major focus of the article is a critical analysis of the design and interpretation of cartilage studies where IL-1ß has been used as a model cytokine. Thirdly, the article provides a data-driven perspective (including genome-wide analysis of clinical samples, studies on mutant mice, and clinical trials), which concludes that IL-1ß should be replaced by soluble mediators such as IL-17 or TGF-ß1, which are much more likely to mimic the disease in OA model systems. We also discuss the evidence that changes in early OA can be attributed to the activity of such soluble mediators, whereas late-stage disease results more from a chronic biomechanical effect on the matrix and cells of the remaining cartilage and on other local mediator-secreting cells. Lastly, an updated protocol for in vitro studies with cartilage explants and chondrocytes (including the use of specific gene expression arrays) is provided to motivate more disease-relevant studies on the interplay of cytokines, growth factors, and biomechanics on cellular behavior.


Subject(s)
Cartilage, Articular/metabolism , Gene Expression , Genome, Human , Inflammation Mediators/metabolism , Osteoarthritis , Animals , Biomechanical Phenomena , Cartilage, Articular/physiopathology , Chondrocytes/metabolism , Chondrocytes/pathology , DNA/genetics , Humans , Osteoarthritis/genetics , Osteoarthritis/metabolism , Osteoarthritis/physiopathology
12.
Tribol Int ; 91: 235-245, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26405372

ABSTRACT

Modern hip prostheses feature a modular implant design with at least one tapered junction. This design can lead to several complications due to the introduction of additional interfaces, which are subjected to various loading conditions and micromotion. The main objective of current study is to develop a fretting corrosion apparatus, which is able characterize the mechanical and electrochemical behaviour of various existing metal alloy couples during fretting motion. This study describes the design and the main considerations during the development of a novel fretting corrosion apparatus, as well as determination of the machine compliance and the initial testing results. Machine compliance considerations and frictional interactions of the couples are discussed in detail. For the preliminary tests, metal alloy pins, made of Ti6Al4V and wrought high-carbon CoCrMo were mechanically polished to a surface roughness of less than 20nm. 2 pins (Diameter = 11mm) of either Ti6Al4V or CoCrMo were loaded onto a Ti6Al4V alloy rod at a normal force of 200N. The interface types included: Ti6Al4V-Ti6Al4V-Ti6Al4V, Ti6Al4V-Ti6Al4V-CoCrMo, and CoCrMo-Ti6Al4V-CoCrMo. The Ti6Al4V rod articulated against the metal alloy pins in a sinusoidal fretting motion with a displacement amplitude of ±50µm. Bovine calf serum (30g/L of protein content) was selected as a lubricant and tested at 2 different pH levels (pH 3.0 and 7.6). In all cases, current and friction energy were monitored during the fretting process. The results indicated distinct, material-specific current evolutions and friction energies. No significant differences were observed in electrochemical or mechanical behaviour in response to pH change. In general, Ti6Al4V-Ti6Al4V-Ti6Al4V couples displayed the earliest passivation and superior electrochemical behaviour compared to Ti6Al4V-Ti6Al4V-CoCrMo and CoCrMo-Ti6Al4V-CoCrMo under fretting conditions. In addition, fluctuations in current were observed in specific regions at all instances where Ti6Al4V was coupled with Ti6Al4V. These fluctuations were not observed in instances where Ti6Al4V was coupled with CoCrMo. These findings suggest transitions in the degradation mechanisms at the modular junction as a function of material couples/contacts. The findings may assist in improving the current hip modular junctions.

13.
Wear ; 332-333: 643-649, 2015.
Article in English | MEDLINE | ID: mdl-26085697

ABSTRACT

Tribochemical reactions in a protein lubricated metal-on-metal (MoM) sliding contact may play a significant role for its wear performance. Such reactions lead to the formation of a carbonaceous 'tribofilm', which can act as a protective layer against corrosion and wear. The purpose of this study was to determine the effect of contact load on wear and the formation and retention of tribofilms. Wear tests were performed in a custom-made ball-on-flat testing apparatus that incorporated an electrochemical cell. A ceramic ball was used to articulate against low-carbon wrought CoCrMo alloy pins in bovine serum. Using a range of contact loads at a single potentiostatic condition (close to free potential), weight loss and changes in surface properties were evaluated. We determined that wear was influenced by the loading condition. As expected, wear increased with load, but the association between applied load and measured weight loss was not linear. In the intermediate load region, in the range of 32-48 N (~58-80 MPa), there was more than an order of magnitude drop in the wear per unit load, and the wear versus load data suggested an inflexion point at 49 N. Regression analyses yielded a cubic model (R2=0.991; p=0.0002), where the cubic term, which represents the inflexion, was highly significant (p=0.0021). This model is supported by the observations that the minimum in the friction versus load curve is at 52 N and the highest relative increase in polarization resistance occurred at 49 N. Scanning electron microscopy and Raman spectroscopy indicated the absence of a tribofilm for the low and within the contact area of the high load cases. Synergistic interactions of wear and corrosion seem to play an important role.

14.
J Mech Behav Biomed Mater ; 29: 199-212, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24099949

ABSTRACT

The demand for total hip replacement (THR) surgery is increasing in the younger population due to faster rehabilitation and more complete restoration of function. Up to 2009, metal-on-metal (MoM) hip joint bearings were a popular choice due to their design flexibility, post-operative stability and relatively low wear rates. The main wear mechanisms that occur along the bearing surface of MoM joints are tribochemical reactions that deposit a mixture of wear debris, metal ions and organic matrix of decomposed proteins known as a tribolayer. No in-depth electrochemical studies have been reported on the structure and characteristics of this tribolayer or about the parameters involved in its formation. In this study, we conducted an electrochemical investigation of different surfaces (bulk-like: control, nano-crystalline: new implant and tribolayer surface: retrieved implant) made out of two commonly used hip CoCrMo alloys (high-carbon and low-carbon). As per ASTM standard, cyclic polarization tests and electrochemical impedance spectroscopy tests were conducted. The results obtained from electrochemical parameters for different surfaces clearly indicated a reduction in corrosion for the tribolayer surface (Icorr: 0.76µA/cm(2)). Further, polarization resistance (Rp:2.39±0.60MΩ/cm(2)) and capacitance (Cdl:15.20±0.75µF/cm(2)) indicated variation in corrosion kinetics for the tribolayer surface, that attributed to its structure and stability in a simulated body environment.


Subject(s)
Hip Joint , Metals, Heavy/chemistry , Alloys/chemistry , Carbon/chemistry , Corrosion , Electrochemistry , Metal Nanoparticles/chemistry , Surface Properties
15.
Wear ; 301(1-2): 168-174, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23794761

ABSTRACT

Wear of polyethylene (UHMWPE) is dependent on cross-shear. The aim of the present study was: 1) to develop a theoretical description of cross-shear, 2) to experimentally determine the relationship between cross-shear motion and UHMWPE wear using a wheel-on-flat apparatus, and 3) to calculate the work it takes to remove a unit volume of wear for the use in advanced computational models of wear. The theoretical description of cross-shear has been based on the previously reported finding that cross-shear is maximal when movement occurs perpendicular to fibril orientation. Here, cross-shear is described with a double-sinusoidal function that uses the angle between fibril orientation and velocity vector as input, and maximum cross-shear occurs at 90° and 270°. In the experimental part of the study, friction and wear of polyethylene were plotted against increasing sliding velocity vector angles, i.e. increasing cross-shear. It was found that wear intensified with increasing cross-shear, and wear depth could be predicted well using the double-sinusoidal function for cross-shear (r2=0.983). The friction data were then used to calculate the work to remove a unit particle by integrating the frictional force over the directional sliding distance. Using the wear volumes, determined for both longitudinal and perpendicular motion directions, the work to remove a unit volume of material was qy = 8.473 × 108 J/mm3 and qx = 1.321 × 108 J/mm3, respectively. Hence, 6.4 times more work was necessary to remove a unit wear volume in the direction of principal motion (i.e. along the molecular fibril orientation) than 90° perpendicular to it. In the future, these findings will be implemented in computational models to assess wear.

16.
Acta Biomater ; 9(9): 8046-58, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23669623

ABSTRACT

Aseptic loosening and other wear-related complications are some of the most frequent late reasons for revision of total knee arthroplasty (TKA). Periprosthetic osteolysis (PPOL) pre-dates aseptic loosening in many cases, indicating the clinical significance of this pathogenic mechanism. A variety of implant-, surgery- and host-related factors have been delineated to explain the development of PPOL. These factors influence the development of PPOL because of changes in mechanical stresses within the vicinity of the prosthetic device, excessive wear of the polyethylene liner, and joint fluid pressure and flow acting on the peri-implant bone. The process of aseptic loosening is initially governed by factors such as implant/limb alignment, device fixation quality and muscle coordination/strength. Later, large numbers of wear particles detached from TKA trigger and perpetuate particle disease, as highlighted by progressive growth of inflammatory/granulomatous tissue around the joint cavity. An increased accumulation of osteoclasts at the bone-implant interface, impairment of osteoblast function, mechanical stresses and increased production of joint fluid contribute to bone resorption and subsequent loosening of the implant. In addition, hypersensitivity and adverse reactions to metal debris may contribute to aseptic TKA failure, but should be determined more precisely. Patient activity level appears to be the most important factor when the long-term development of PPOL is considered. Surgical technique, implant design and material factors are the most important preventative factors, because they influence both the generation of wear debris and excessive mechanical stresses. New generations of bearing surfaces and designs for TKA should carefully address these important issues in extensive preclinical studies. Currently, there is little evidence that PPOL can be prevented by pharmacological intervention.


Subject(s)
Biocompatible Materials/adverse effects , Knee Joint/physiopathology , Knee Prosthesis/adverse effects , Osteolysis/etiology , Osteolysis/physiopathology , Animals , Humans , Models, Biological , Prosthesis Failure
17.
Orthop Traumatol Surg Res ; 99(3): 263-71, 2013 May.
Article in English | MEDLINE | ID: mdl-23507457

ABSTRACT

INTRODUCTION: There is an ongoing debate about the optimal use of metal-on-metal (MoM) bearings in total hip replacement, since there are uncertainties about local and systemic adverse effects due to wear and corrosion of these bearings. Despite various national recommendations, efforts to achieve international harmonization of specific evidence-based recommendations for best practice are still lacking. HYPOTHESIS: An international consensus study group should be able to develop recommendations on the use and monitoring of MoM bearings, preferably at the European level, through a multidisciplinary approach, by integrating the perspectives of various stakeholders. MATERIALS AND METHODS: Twenty-one experts representing three stakeholder groups and eight countries participated in this European consensus study, which consisted of a consensus meeting, subsequent structured discussion, and consensus voting. RESULTS: The current statement defines first of all benefits, local and systemic risks, as well as uncertain issues related to MoM bearings. Safety assessment after implantation of MoM comprises all patients. A closer follow-up is recommended for large head MoM (≥36mm) and resurfacing. In these implants basic follow-up should consist of x-rays and metal ion measurement of cobalt in whole blood, performed with GF-AAS or ICP-MS. Clinical and/or radiographic abnormality as well as elevated ion levels needs additional imaging (ultrasound, CT-scan and/or MARS-MRI). Cobalt values less than 2 µg/L are probably devoid of clinical concern, the threshold value for clinical concern is expected to be within the range of 2-7 µg/L. DISCUSSION: This is the first multinational, interdisciplinary, and multiprofessional approach for developing a recommendation for the use and monitoring of MoM bearings in total hip replacement. The current recommendations are in partial agreement with previous statements regarding the extent of follow-up and imaging techniques. They however differ from previous communications regarding measurement of metal ions and especially the investigated medium, technique, and eventual threshold levels. LEVEL OF EVIDENCE: Level V, expert opinion/agreement conference.


Subject(s)
Hip Prosthesis , Metal-on-Metal Joint Prostheses , Arthroplasty, Replacement, Hip , Cobalt , Europe , Humans , Osteoarthritis, Hip/surgery , Particle Size
18.
Trends Appl Spectrosc ; 10: 43-48, 2013.
Article in English | MEDLINE | ID: mdl-24920867

ABSTRACT

Ultra-high molecular weight polyethylene (UHMWPE) is the most common counterface material against metals or ceramics in artificial hip or knee joints. Wear and the resulting particulate debris, however, limit the life span of the implant. In this study, the general feasibility of using Europium (Eu) as tracer material to quantify UHMWPE wear in joint fluid is investigated. Using Inductively Coupled Mass Spectrometry (ICP-MS), recovery experiments of Eu in artificial joint fluid were performed. In order to dope polyethylene with 50 ppm Eu, nascent UHMWPE powder was mixed with a solution of Eu-stearate. The heterogeneity of the mixture was assessed by determining the coefficient of variation (CV) of the Eu content in various weighted samples. After molding of the UHMWPE powder mixture, cylindrical pins of 10 mm diameter were machined and worn against cobalt-chromium metal disks submersed in artificial joint fluid. The Eu-content of fluid samples taken at certain time intervals was measured and compared with UHMWPE weight loss of the pins. A satisfactory homogenization of Eu in the UHMWPE powder was achieved. Tracer-based and weight-loss determined wear rates were highly correlated (Pearson correlation coefficients > 0.991). Also the detection bias was within acceptable limits. Thus both methods demonstrated good agreement.

19.
J Mech Behav Biomed Mater ; 12: 39-49, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22659365

ABSTRACT

The microstructural and mechanical properties of the hard phases in CoCrMo prosthetic alloys in both cast and wrought conditions were examined using transmission electron microscopy and nanoindentation. Besides the known carbides of M(23)C(6)-type (M=Cr, Mo, Co) and M(6)C-type which are formed by either eutectic solidification or precipitation, a new mixed-phase hard constituent has been found in the cast alloys, which is composed of ∼100 nm fine grains. The nanosized grains were identified to be mostly of M(23)C(6) type using nano-beam precession electron diffraction, and the chemical composition varied from grain to grain being either Cr- or Co-rich. In contrast, the carbides within the wrought alloy having the same M(23)C(6) structure were homogeneous, which can be attributed to the repeated heating and deformation steps. Nanoindentation measurements showed that the hardness of the hard phase mixture in the cast specimen was ∼15.7 GPa, while the M(23)C(6) carbides in the wrought alloy were twice as hard (∼30.7 GPa). The origin of the nanostructured hard phase mixture was found to be related to slow cooling during casting. Mixed hard phases were produced at a cooling rate of 0.2 °C/s, whereas single phase carbides were formed at a cooling rate of 50 °C/s. This is consistent with sluggish kinetics and rationalizes different and partly conflicting microstructural results in the literature, and could be a source of variations in the performance of prosthetic devices in-vivo.


Subject(s)
Arthroplasty, Replacement, Hip/instrumentation , Prosthesis Design/methods , Vitallium/chemistry , Alloys , Arthroplasty, Replacement, Hip/methods , Biomechanical Phenomena , Electrons , Equipment Design , Hardness , Humans , Materials Testing , Microscopy/methods , Microscopy, Electron, Scanning/methods , Microscopy, Electron, Transmission/methods , Pressure , Prostheses and Implants , Temperature
20.
Science ; 334(6063): 1687-90, 2011 Dec 23.
Article in English | MEDLINE | ID: mdl-22194573

ABSTRACT

Arthritis is a leading cause of disability, and when nonoperative methods have failed, a prosthetic implant is a cost-effective and clinically successful treatment. Metal-on-metal replacements are an attractive implant technology, a lower-wear alternative to metal-on-polyethylene devices. Relatively little is known about how sliding occurs in these implants, except that proteins play a critical role and that there is a tribological layer on the metal surface. We report evidence for graphitic material in the tribological layer in metal-on-metal hip replacements retrieved from patients. As graphite is a solid lubricant, its presence helps to explain why these components exhibit low wear and suggests methods of improving their performance; simultaneously, this raises the issue of the physiological effects of graphitic wear debris.


Subject(s)
Graphite/analysis , Hip Prosthesis , Vitallium , Animals , Arthroplasty, Replacement, Hip , Biocompatible Materials , Cattle , Corrosion , Friction , Hip Prosthesis/adverse effects , Humans , Metal Nanoparticles , Prosthesis Design , Prosthesis Failure , Serum , Spectroscopy, Electron Energy-Loss , Spectrum Analysis, Raman , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...