Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 28(11): 16951-16967, 2020 May 25.
Article in English | MEDLINE | ID: mdl-32549507

ABSTRACT

Manipulating the atomic and electronic structure of matter with strong terahertz (THz) fields while probing the response with ultrafast pulses at x-ray free electron lasers (FELs) has offered unique insights into a multitude of physical phenomena in solid state and atomic physics. Recent upgrades of x-ray FEL facilities are pushing to much higher repetition rates, enabling unprecedented signal-to-noise ratio for pump probe experiments. This requires the development of suitable THz pump sources that are able to deliver intense pulses at compatible repetition rates. Here we present a high-power laser-driven THz source based on optical rectification in LiNbO3 using tilted pulse front pumping. Our source is driven by a kilowatt-level Yb:YAG amplifier system operating at 100 kHz repetition rate and employing nonlinear spectral broadening and recompression to achieve sub-100 fs pulses with pulse energies up to 7 mJ that are necessary for high THz conversion efficiency and peak field strength. We demonstrate a maximum of 144 mW average THz power (1.44 µJ pulse energy), consisting of single-cycle pulses centered at 0.6 THz with a peak electric field strength exceeding 150 kV/cm. These high field pulses open up a range of possibilities for nonlinear time-resolved THz experiments at unprecedented rates.

2.
Opt Lett ; 44(17): 4287-4290, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31465384

ABSTRACT

New high-repetition-rate x-ray free electron lasers (XFELs) require for their operation highly reliable ultrafast laser systems with high pulse energy, high repetition rate, and high average power. In this Letter, we present high-average-power scaling of near-infrared optical parametric chirped pulse amplification (OPCPA) in potassium titanyl arsenate (KTA) with tunable center wavelengths from 1.5 to 2.0 µm. Using a three-stage amplification scheme and a kW-level InnoSlab Yb:YAG pump amplifier for the final non-collinear KTA stage, we demonstrate an amplified output power of 106.2 W at a center wavelength of 1.75 µm and 100 kHz. Idler absorption introduces a potential upper limit on the average power scaling of center wavelengths <1.70 µm. Future scaling of average power to hundreds of Watts is possible at center wavelengths ≥1.70 µm.

3.
Opt Lett ; 44(5): 1257-1260, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30821762

ABSTRACT

We present a 100 kHz, sub-20 fs optical parametric chirped-pulse amplifier (OPCPA) system delivering 88.6 W average power at a center wavelength of 800 nm. The seed pulses are derived from the pump laser via white-light continuum generation and are amplified in three non-collinear OPCPA stages. The final two high-power stages are pumped with a 661 W Yb:YAG InnoSlab amplifier. A simple and robust design is used for the OPCPA system to avoid thermal effects and enhance long-term stability, resulting in excellent beam quality and high conversion efficiency. To the best of our knowledge, this is the highest average power OPCPA system reported to date.

SELECTION OF CITATIONS
SEARCH DETAIL
...