Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 131: 214-222, 2016 Nov 30.
Article in English | MEDLINE | ID: mdl-27599352

ABSTRACT

An increasing demand of new analytical methods is associated with the growing number of biotherapeutic programs being prosecuted in the pharmaceutical industry. Whilst immunoassay has been the standard method for decades, a great interest in assays based on liquid chromatography tandem mass spectrometry (LC-MS/MS) is evolving. In this present work, the development of a generic method for the quantitative analysis of therapeutic proteins based on human immunoglobulin G (hIgG) in rat serum is reported. The method is based on four generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), VVSVLTVLHQDWLNGK (VVS) and FNWYVDGVEVHNAK (FNW) originating from different parts of the fraction crystallizable (Fc) region of a reference hIgG1 (hIgG1A). A tryptic pellet digestion of rat serum spiked with hIgG1A and a stable isotope labeled protein (hIgG1B) used as internal standard (ISTD) was applied prior LC-MS/MS analysis. The upper limit of quantification was at 1000µg/mL. The lower limit of quantitation was for GPS, TTP and VVS at 1.00µg/mL whereas for FNW at 5.00µg/mL. Accuracy and precision data met acceptance over three days. The presented method was further successfully applied to the quantitative analysis of other hIgG1s (hIgG1C and hIgG1D) and hIgG4-based therapeutic proteins on spiked quality control (QC) samples in monkey and rat serum using calibration standards (Cs) prepared with hIgG1A in rat serum. In order to extend the applicability of our generic approach, a bispecific-bivalent hIgG1 (bb-hIgG1) and two lysine conjugated antibody-drug conjugates (ADC1 and ADC2) were incorporated as well. The observed values on spiked QC samples in monkey serum were satisfactory with GPS for the determination of bb-hIgG1 whereas the FNW and TTP peptides were suitable for the ADCs. Moreover, comparable mean concentration-time profiles were obtained from monkeys previously dosed intravenously with ADC2 measured against Cs samples prepared either with hIgG1A in rat serum (presented approach) or with the actual ADC2 in monkey serum (conventional approach). The results of this study highlight the great flexibility of our newly developed generic approach and that the choice of the surrogate peptide still remains critical when dealing with different matrix types or modalities.


Subject(s)
Chromatography, Liquid/methods , Immunoglobulin G/blood , Peptide Fragments/blood , Tandem Mass Spectrometry/methods , Animals , Macaca fascicularis , Rats , Reproducibility of Results
2.
Drug Metab Dispos ; 44(7): 897-910, 2016 07.
Article in English | MEDLINE | ID: mdl-27122302

ABSTRACT

For antibody drug conjugates (ADCs), the fate of the cytotoxic payload in vivo needs to be well understood to mitigate toxicity risks and properly design the first in-patient studies. Therefore, a distribution, metabolism, and excretion (DME) study with a radiolabeled rat cross-reactive ADC ([(3)H]DM1-LNL897) targeting the P-cadherin receptor was conducted in female tumor-bearing nude rats. Although multiple components [total radioactivity, conjugated ADC, total ADC, emtansine (DM1) payload, and catabolites] needed to be monitored with different technologies (liquid scintillation counting, liquid chromatography/mass spectrometry, enzyme-linked immunosorbent assay, and size exclusion chromatography), the pharmacokinetic data were nearly superimposable with the various techniques. [(3)H]DM1-LNL897 was cleared with half-lives of 51-62 hours and LNL897-related radioactivity showed a minor extent of tissue distribution. The highest tissue concentrations of [(3)H]DM1-LNL897-related radioactivity were measured in tumor. Complimentary liquid extraction surface analysis coupled to micro-liquid chromatography-tandem mass spectrometry data proved that the lysine (LYS)-4(maleimidylmethyl) cyclohexane-1-carboxylate-DM1 (LYS-MCC-DM1) catabolite was the only detectable component distributed evenly in the tumor and liver tissue. The mass balance was complete with up to 13.8% ± 0.482% of the administered radioactivity remaining in carcass 168 hours postdose. LNL897-derived radioactivity was mainly excreted via feces (84.5% ± 3.12%) and through urine only to a minor extent (4.15% ± 0.462%). In serum, the major part of radioactivity could be attributed to ADC, while small molecule disposition products were the predominant species in excreta. We show that there is a difference in metabolite profiles depending on which derivatization methods for DM1 were applied. Besides previously published results on LYS-MCC-DM1 and MCC-DM1, maysine and a cysteine conjugate of DM1 could be identified in serum and excreta.


Subject(s)
Antibodies/metabolism , Antineoplastic Agents, Phytogenic/pharmacokinetics , Breast Neoplasms/drug therapy , Immunoconjugates/pharmacokinetics , Maytansine/pharmacokinetics , Administration, Intravenous , Animals , Antibodies/administration & dosage , Antibodies/blood , Antineoplastic Agents, Phytogenic/administration & dosage , Antineoplastic Agents, Phytogenic/blood , Area Under Curve , Biological Availability , Biotransformation , Breast Neoplasms/blood , Breast Neoplasms/pathology , Cadherins/immunology , Cadherins/metabolism , Cell Line, Tumor , Feces/chemistry , Female , Half-Life , Humans , Immunoconjugates/administration & dosage , Immunoconjugates/blood , Maytansine/administration & dosage , Maytansine/blood , Metabolic Clearance Rate , Rats, Nude , Tissue Distribution
3.
Rapid Commun Mass Spectrom ; 30(7): 823-32, 2016 Apr 15.
Article in English | MEDLINE | ID: mdl-26969923

ABSTRACT

RATIONALE: Antibody-drug conjugates (ADCs) are some of the most promising antibody-related therapeutics. The fate of the cytotoxic moiety of ADCs in vivo after proteolytic degradation of the antibody needs to be well understood in order to mitigate toxicity risks and design proper first in patient studies. METHODS: The feasibility of liquid extraction surface analysis micro-capillary liquid chromatography/tandem mass spectrometry (LESA-µLC/MS/MS) was tested for direct surface sampling of two possible ADC catabolites composed of synthetically modified maytansinoid (DM1) and 4-[N-maleimidomethyl]cyclohexane-1-carbonyl (MCC) from rat liver and tumor tissue. Moreover, the iMatrixSpray was incorporated to prepare calibration standards (Cs) and quality control (QC) samples by spraying analyte solution at different concentrations directly on blank tissue. RESULTS: Lys-MCC-DM1 sprayed on blank liver tissue was homogeneously distributed (12.3% variability). The assay was selective (inference ≤20%) and linear from 50.0 to 1000 ng/mL without any carry-over. Inter-run accuracy and precision were ≤2.3% and ≤25.9% meeting acceptance. Lys-MCC-DM1 was the only catabolite detected in liver and tumor tissue and was most likely responsible for the total radioactivity signal in liver tissue 72 h post-dose measured by quantitative whole body autoradiography (QWBA). CONCLUSIONS: Both analytical assays (LESA-µLC/MS/MS and QWBA) are complementary to each other and provide useful quantitative and qualitative information in spatial tissue distribution of ADCs and their related catabolites. Copyright © 2016 John Wiley & Sons, Ltd.


Subject(s)
Antineoplastic Agents/analysis , Immunoconjugates/analysis , Liquid-Liquid Extraction/methods , Liver/chemistry , Neoplasms/chemistry , Tandem Mass Spectrometry/methods , Animals , Antineoplastic Agents/metabolism , Chromatography, Liquid/methods , Immunoconjugates/metabolism , Linear Models , Maleimides , Maytansine , Models, Biological , Molecular Imaging , Rats , Reproducibility of Results
4.
Anal Bioanal Chem ; 408(6): 1687-99, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26758601

ABSTRACT

In the present study, the application of a liquid chromatography high-resolution mass spectrometry (LC-HRMS) analytical assay for the quantitative analysis of a recombinant human immunoglobulin G1 (hIgG1) in rat serum is reported using three generic peptides GPSVFPLAPSSK (GPS), TTPPVLDSDGSFFLYSK (TTP), and VVSVLTVLHQDWLNGK (VVS). Moreover, the deamidation site of a fourth peptide FNWYVDGVEVHNAK (FNW) was identified and further excluded from the assay evaluation due to the inaccuracy of the quantitative results. The rat serum samples were spiked with a fully labeled hIgG1 as internal standard (ISTD). The digestion with trypsin was performed onto the pellet prior to peptide analysis by LC-HRMS using a quadrupole time of flight (QTOF) mass analyzer operating in selected reaction monitoring (SRM) mode with enhanced duty cycles (EDC). The assay linearity for the three investigated peptides was established for a hIgG1 (hIgG1A) from 1.00 to 1000 µg mL(-1) with a mean coefficient of determination (R (2)) higher than 0.9868. The inter-day accuracy and precision obtained in rat serum over 3 days were ≤11.4 and ≤10.5%, respectively. Short-term stability on the auto-sampler at 6 °C for 30 h, at RT for 48 h, and a 100-fold dilution factor were demonstrated. In addition, QC samples prepared in cynomolgus monkey serum and measured with the present method met the acceptance criteria of ±20.0 and ≤20.0% for all three peptides regarding accuracy and precision, respectively. The LC-HRMS method was applied to the analysis of samples from five individual cynomolgus monkeys dosed with a second hIgG1 (hIgG1B) and consistent data were obtained compared to the LC-MS/MS method (conventional triple quadrupole (QqQ) mass analyzer operating in SRM). The present data demonstrate that LC-HRMS can be used for the quantitative analysis of hIgG1 in both species and that quantification is not only limited to classical QqQ instruments.


Subject(s)
Immunoglobulin G/blood , Mass Spectrometry/methods , Recombinant Proteins/blood , Amino Acid Sequence , Animals , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Female , Humans , Immunoglobulin G/genetics , Macaca fascicularis , Mass Spectrometry/standards , Molecular Sequence Data , Peptides/chemistry , Peptides/metabolism , Rats , Recombinant Proteins/genetics , Recombinant Proteins/pharmacology , Sensitivity and Specificity , Spectrometry, Mass, Electrospray Ionization/methods
5.
Xenobiotica ; 45(2): 107-23, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25180976

ABSTRACT

1. 4-[2((1R,2R)-2-Hydroxycyclohexylamino)-benzothiazol-6-yloxyl]-pyridine-2-carboxylic acid methylamide (BLZ945) is a small molecule inhibitor of CSF-1R kinase activity within osteoclasts designed to prevent skeletal related events in metastatic disease. Key metabolites were enzymatically and structurally characterized to understand the metabolic fate of BLZ945 and pharmacological implications. The relative intrinsic clearances for metabolites were derived from in vitro studies using human hepatocytes, microsomes and phenotyped with recombinant P450 enzymes. 2. Formation of a pharmacologically active metabolite (M9) was observed in human hepatocytes. The M9 metabolite is a structural isomer (diastereomer) of BLZ945 and is about 4-fold less potent. This isomer was enzymatically formed via P450 oxidation of the BLZ945 hydroxyl group, followed by aldo-keto reduction to the alcohol (M9). 3. Two reaction phenotyping approaches based on fractional clearances were applied to BLZ945 using hepatocytes and liver microsomes. The fraction metabolized (fm) or contribution ratio was determined for each metabolic reaction type (oxidation, glucuronidation or isomerization) as well as for each metabolite. The results quantitatively illustrate contribution ratios of the involved enzymes and pathways, e.g. the isomerization to metabolite M9 accounted for 24% intrinsic clearance in human hepatocytes. In summary, contribution ratios for the Phase I and Phase II pathways can be determined in hepatocytes.


Subject(s)
Benzothiazoles/metabolism , Hepatocytes/enzymology , Microsomes, Liver/enzymology , Picolinic Acids/metabolism , Protein Kinase Inhibitors/metabolism , Receptor, Macrophage Colony-Stimulating Factor/antagonists & inhibitors , Benzothiazoles/chemistry , Benzothiazoles/pharmacology , Cell Line , Cell Proliferation/drug effects , Cytochrome P-450 Enzyme System/metabolism , Humans , Metabolic Networks and Pathways , Picolinic Acids/chemistry , Picolinic Acids/pharmacology , Protein Kinase Inhibitors/chemistry , Protein Kinase Inhibitors/pharmacology , Receptor, Macrophage Colony-Stimulating Factor/chemistry , Receptor, Macrophage Colony-Stimulating Factor/metabolism , Signal Transduction/drug effects
6.
Drug Metab Dispos ; 41(9): 1626-41, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23775850

ABSTRACT

The disposition and biotransformation of (14)C-radiolabeled mavoglurant were investigated in four healthy male subjects after a single oral dose of 200 mg. Blood, plasma, urine, and feces collected over 7 days were analyzed for total radioactivity, mavoglurant was quantified in plasma by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS), and metabolite profiles were generated in plasma and excreta by high-performance liquid chromatography (HPLC) and radioactivity detection. The chemical structures of mavoglurant metabolites were characterized by LC-MS/MS, wet-chemical and enzymatic methods, NMR spectroscopy, and comparison with reference compounds. Mavoglurant was safe and well tolerated in this study population. Mavoglurant absorption was ≥50% of dose reaching mean plasma Cmax values of 140 ng/ml (mavoglurant) and 855 ng-eq/ml (total radioactivity) at 2.5 and 3.6 hours, respectively. Thereafter, mavoglurant and total radioactivity concentrations declined with mean apparent half-lives of 12 and 18 hours, respectively. The elimination of mavoglurant occurred predominantly by oxidative metabolism involving primarily 1) oxidation of the tolyl-methyl group to a benzyl-alcohol metabolite (M7) and subsequently to a benzoic acid metabolite (M6), and 2) oxidation of the phenyl-ring leading to a hydroxylated metabolite (M3). The subjects were mainly exposed to mavoglurant and seven main metabolites, which combined accounted for 60% of (14)C-AUC0-72 h (area under the concentration-time curve from time 0 to infinity). The primary steps of mavoglurant metabolism observed in vivo could partially be reproduced in vitro in incubations with human liver microsomes and recombinant cytochrome P450 enzymes. After 7 days, the mean balance of total radioactivity excretion was almost complete (95.3% of dose) with 36.7% recovered in urine and 58.6% in feces.


Subject(s)
Indoles/metabolism , Indoles/pharmacokinetics , Receptor, Metabotropic Glutamate 5/antagonists & inhibitors , Receptor, Metabotropic Glutamate 5/metabolism , Absorption , Adult , Area Under Curve , Carbon Radioisotopes/blood , Carbon Radioisotopes/metabolism , Carbon Radioisotopes/pharmacokinetics , Carbon Radioisotopes/urine , Cytochrome P-450 Enzyme System/metabolism , Feces/chemistry , Half-Life , Humans , Indoles/blood , Indoles/urine , Male , Microsomes, Liver/enzymology , Microsomes, Liver/metabolism , Oxidation-Reduction
7.
PLoS One ; 7(6): e39070, 2012.
Article in English | MEDLINE | ID: mdl-22723932

ABSTRACT

Generation and interpretation of biotransformation data on drugs, i.e. identification of physiologically relevant metabolites, defining metabolic pathways and elucidation of metabolite structures, have become increasingly important to the drug development process. Profiling using (14)C or (3)H radiolabel is defined as the chromatographic separation and quantification of drug-related material in a given biological sample derived from an in vitro, preclinical in vivo or clinical study. Metabolite profiling is a very time intensive activity, particularly for preclinical in vivo or clinical studies which have defined limitations on radiation burden and exposure levels. A clear gap exists for certain studies which do not require specialized high volume automation technologies, yet these studies would still clearly benefit from automation. Use of radiolabeled compounds in preclinical and clinical ADME studies, specifically for metabolite profiling and identification are a very good example. The current lack of automation for measuring low level radioactivity in metabolite profiling requires substantial capacity, personal attention and resources from laboratory scientists. To help address these challenges and improve efficiency, we have innovated, developed and implemented a novel and flexible automation platform that integrates a robotic plate handling platform, HPLC or UPLC system, mass spectrometer and an automated fraction collector.


Subject(s)
Automation, Laboratory , Metabolomics/instrumentation , Metabolomics/methods , Biotransformation , Drug Evaluation, Preclinical/instrumentation , Drug Evaluation, Preclinical/methods , High-Throughput Screening Assays/instrumentation , High-Throughput Screening Assays/methods , Radioactivity
SELECTION OF CITATIONS
SEARCH DETAIL