1.
Nat Commun ; 15(1): 1225, 2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38336952

ABSTRACT

High quantum efficiency and wide-band detection capability are the major thrusts of infrared sensing technology. However, bulk materials with high efficiency have consistently encountered challenges in integration and operational complexity. Meanwhile, two-dimensional (2D) semimetal materials with unique zero-bandgap structures are constrained by the bottleneck of intrinsic quantum efficiency. Here, we report a near-mid infrared ultra-miniaturized graphene photodetector with configurable 2D potential well. The 2D potential well constructed by dielectric structures can spatially (laterally and vertically) produce a strong trapping force on the photogenerated carriers in graphene and inhibit their recombination, thereby improving the external quantum efficiency (EQE) and photogain of the device with wavelength-immunity, which enable a high responsivity of 0.2 A/W-38 A/W across a broad infrared detection band from 1.55 to 11 µm. Thereafter, a room-temperature detectivity approaching 1 × 109 cm Hz1/2 W-1 is obtained under blackbody radiation. Furthermore, a synergistic effect of electric and light field in the 2D potential well enables high-efficiency polarization-sensitive detection at tunable wavelengths. Our strategy opens up alternative possibilities for easy fabrication, high-performance and multifunctional infrared photodetectors.

2.
Nanoscale ; 15(23): 10057-10066, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37249020

ABSTRACT

Breast cancer is the most prevalent cancer globally. Early detection is crucial and can be achieved by detecting cancer biomarkers in blood, such as circulating miRNAs (microRNAs). In this study, we present a label-free detection method based on broadband multi-resonant infrared metasurface for surface-enhanced infrared absorption (SEIRA) spectroscopy to detect miRNAs. The SEIRA resonances were optimized to match the miRNA biomarker fingerprint regions in the range of 800 to 2000 cm-1 and 2800 to 3500 cm-1, resulting in a simulated resonance enhancement of up to 103 times. Nine patient samples (six cancerous and three non-cancerous) were measured using SEIRA multi-well sensor chips. A novel analysis method, SEIRA-AR, was also developed to benchmark the results against industry standards, such as quantitative reverse transcription polymerase chain reaction (RT-qPCR) and next-generation sequencing (NGS). Our results showed an excellent linear correlation with a Pearson's r value of up to 0.99 and an R Squared value of up to 0.98. This study represents the first use of a SEIRA sensor for biomarker detection on clinical breast cancer samples and introduces an analysis method that produces results comparable to industry standards. Our findings pave the way for routine cancer diagnosis in the future. Additionally, the method discussed can be generalized to other biosensing activities involving two-step binding processes with complementary molecule-capturing agents.


Subject(s)
Breast Neoplasms , Circulating MicroRNA , MicroRNAs , Humans , Female , MicroRNAs/analysis , Breast Neoplasms/genetics , Early Detection of Cancer , Biomarkers, Tumor
3.
Sci Rep ; 12(1): 19229, 2022 11 10.
Article in English | MEDLINE | ID: mdl-36357510

ABSTRACT

Terahertz (THz) spectroscopy technique has been applied in ex vivo biomechanical properties analysis of human corneas. Upon the application of light pressure on the cornea, the photo elastic birefringent effect, anisotropic deformation, thickness changes and hydration levels will contribute to the sudden phase changes of terahertz time domain signal. The shelf lifetime study shows that the phase shift is reduced and cornea loose the biomechanical properties with the increase of hydration level. Mechanical behaviors have been further studied based on the "fresh" cut corneas with the similar hydration levels. THz signal was collected by focusing inside of the cornea to avoid the phase shift due to light stress caused movement of the corneal surface. By this way, the amount of THz signal refractive index variation is correlated to the elastic property of the corneas. The correlation between the THz signal phase shift and refractive index shift due to the corneal strain can be used to derive the elastic Young's modulus. Our results demonstrated the THz spectroscopy, as a non-contact and non-invasive detection method, could be potential for understanding the mechanism of corneal deformation under the action of intraocular pressure in the physiological environment in future.


Subject(s)
Cornea , Tonometry, Ocular , Humans , Cornea/physiology , Elastic Modulus , Intraocular Pressure , Technology , Biomechanical Phenomena
4.
J Biophotonics ; 14(9): e202100130, 2021 09.
Article in English | MEDLINE | ID: mdl-34105892

ABSTRACT

A Novel scalable approach using Terahertz (THz) waves together with the electromagnetic field simulation was applied to investigate four rabbits of eight rabbit corneas in vivo. One eye of each rabbits' corneas was edema induced; the other eye of the corneas served as the control. The simulation revealed the propagation of THz waves at a certain distance along the sub-surface of the cornea. THz spectra have been collected close to the corneal surface by deviating the direct reflection of the THz beam for the edema cornea, the reflected wave intensity for edema corneas is generally larger compared with the control cornea. Upon edema becomes severe at the end of the observation, the reflected wave intensities obtained by detector corresponding to the corneal deep stroma layer approach to the same value for all observed corneas. Good correlation is observed between central corneal thickness measurements and THz wave reflection signal intensities. Our results demonstrated that THz spectroscopy technique could obtain the information from different corneal sublayers.


Subject(s)
Cornea , Terahertz Spectroscopy , Animals , Edema , Rabbits , Technology
5.
J Biomed Opt ; 26(4)2021 04.
Article in English | MEDLINE | ID: mdl-33899380

ABSTRACT

SIGNIFICANCE: Corneal diseases is a major cause of reversible blindness in the world. Monitoring the progression of human corneal edema or corneal scarring to prevent the disease entering into the end stage is crucial. AIM: We present a method for sensing human corneal composition at different depths, namely focused on the epithelium and stromal layer, using high-sensitivity terahertz (THz) broadband spectroscopy. APPROACH: From the proposed methodology, the THz temporal and absorption spectra of human corneas at different edema stages have been studied. THz wave signals were collected from the direct reflection and four other collection points along the THz wave propagation direction as reviewed from the simulation THz electrical field. RESULT: Our results show that the epithelium layer acts as a good barrier to maintain hydration level of the stroma, and the quality of the epithelium can be used to predict the level of corneal swelling in corneal edema. At the detection points near to the incident point, the THz frequency spectra demonstrated interference oscillation behavior. At the final edema observing time, results showed that the epithelium lose its barrier properties. The intactness of the epithelium can be used to predict the edema severity in the final stage. When the detection points are further away from the incident point, the THz spectra are believed to contain information from stromal layer. Stromal absorption spectra demonstrated correlation with optical coherence tomography thickness results. CONCLUSION: The hydration concentration from stromal layer was further quantitatively calculated. At the end of the experiment, all the corneal hydration levels reach to the same value which shows that the edema hydration has reached maximum saturation. The information of individual sublayers of the cornea is obtained by characterizing noninvasively with the use of THz spectroscopy. To our knowledge, this is the first report of using THz for noninvasive characterization of sublayers of the cornea.


Subject(s)
Corneal Diseases , Corneal Injuries , Terahertz Spectroscopy , Cornea/diagnostic imaging , Edema , Humans
6.
Spectrochim Acta A Mol Biomol Spectrosc ; 255: 119667, 2021 Jul 05.
Article in English | MEDLINE | ID: mdl-33773432

ABSTRACT

Pulsed terahertz (THz) broadband spectroscopy and imaging were applied to investigate ex vivo rabbit corneal scar tissues. Scars with different depths and densities were created by laser ablation on four corneal samples while two corneal samples untouched were used as control. The THz time-domain spectroscopy and reconstructed images illustrated the scar tissue density and gave out depth variation distribution profiles. Calculated absorption coefficient spectra displayed extra absorption peaks compared with control corneas and refractive index spectra showed the optical properties changed at the corneal scar locations. THz spectroscopy and imaging demonstrated adequate contrast in reviewing the scar densities and locations and showed potential applications in depicting spatial distribution and composition changes of corneal scars.


Subject(s)
Corneal Injuries , Terahertz Spectroscopy , Animals , Diagnostic Imaging , Rabbits , Refractometry
8.
Nat Nanotechnol ; 15(8): 675-682, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32601449

ABSTRACT

The development of infrared photodetectors is mainly limited by the choice of available materials and the intricate crystal growth process. Moreover, thermally activated carriers in traditional III-V and II-VI semiconductors enforce low operating temperatures in the infrared photodetectors. Here we demonstrate infrared photodetection enabled by interlayer excitons (ILEs) generated between tungsten and hafnium disulfide, WS2/HfS2. The photodetector operates at room temperature and shows an even higher performance at higher temperatures owing to the large exciton binding energy and phonon-assisted optical transition. The unique band alignment in the WS2/HfS2 heterostructure allows interlayer bandgap tuning from the mid- to long-wave infrared spectrum. We postulate that the sizeable charge delocalization and ILE accumulation at the interface result in a greatly enhanced oscillator strength of the ILEs and a high responsivity of the photodetector. The sensitivity of ILEs to the thickness of two-dimensional materials and the external field provides an excellent platform to realize robust tunable room temperature infrared photodetectors.

9.
Nanotechnology ; 26(25): 255201, 2015 Jan 26.
Article in English | MEDLINE | ID: mdl-26041560

ABSTRACT

Branchlike nano-electrode structures were found to improve the THz emission intensity of a photomixer by approximately one order of magnitude higher than that of a photomixer with one row of nano-electrodes separated by the same 100 nm gap. The enhancement is attributed to a more efficient collection of generated carriers, which is in turn due to a more intense electric field under the branchlike nano-electrodes' structures. This is coupled with an increased number of effective areas where strong tip-to-tip THz field enhancements were observed. The optical-to-THz conversion efficiency of the photomixers with the new branchlike nano-electrodes was found to be 10 times higher. The more efficient THz photomixer will greatly benefit the development of continuous-wave THz imaging and spectroscopy systems.

SELECTION OF CITATIONS