Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Nature ; 629(8013): 810-818, 2024 May.
Article in English | MEDLINE | ID: mdl-38778234

ABSTRACT

Accurate and continuous monitoring of cerebral blood flow is valuable for clinical neurocritical care and fundamental neurovascular research. Transcranial Doppler (TCD) ultrasonography is a widely used non-invasive method for evaluating cerebral blood flow1, but the conventional rigid design severely limits the measurement accuracy of the complex three-dimensional (3D) vascular networks and the practicality for prolonged recording2. Here we report a conformal ultrasound patch for hands-free volumetric imaging and continuous monitoring of cerebral blood flow. The 2 MHz ultrasound waves reduce the attenuation and phase aberration caused by the skull, and the copper mesh shielding layer provides conformal contact to the skin while improving the signal-to-noise ratio by 5 dB. Ultrafast ultrasound imaging based on diverging waves can accurately render the circle of Willis in 3D and minimize human errors during examinations. Focused ultrasound waves allow the recording of blood flow spectra at selected locations continuously. The high accuracy of the conformal ultrasound patch was confirmed in comparison with a conventional TCD probe on 36 participants, showing a mean difference and standard deviation of difference as -1.51 ± 4.34 cm s-1, -0.84 ± 3.06 cm s-1 and -0.50 ± 2.55 cm s-1 for peak systolic velocity, mean flow velocity, and end diastolic velocity, respectively. The measurement success rate was 70.6%, compared with 75.3% for a conventional TCD probe. Furthermore, we demonstrate continuous blood flow spectra during different interventions and identify cascades of intracranial B waves during drowsiness within 4 h of recording.


Subject(s)
Blood Flow Velocity , Brain , Cerebrovascular Circulation , Ultrasonography , Humans , Blood Flow Velocity/physiology , Brain/blood supply , Brain/diagnostic imaging , Brain/physiology , Cerebrovascular Circulation/physiology , Imaging, Three-Dimensional/instrumentation , Imaging, Three-Dimensional/methods , Medical Errors , Signal-To-Noise Ratio , Skin , Skull , Sleepiness/physiology , Ultrasonography/instrumentation , Ultrasonography/methods , Adult
2.
Nat Biotechnol ; 42(3): 448-457, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37217752

ABSTRACT

Recent advances in wearable ultrasound technologies have demonstrated the potential for hands-free data acquisition, but technical barriers remain as these probes require wire connections, can lose track of moving targets and create data-interpretation challenges. Here we report a fully integrated autonomous wearable ultrasonic-system-on-patch (USoP). A miniaturized flexible control circuit is designed to interface with an ultrasound transducer array for signal pre-conditioning and wireless data communication. Machine learning is used to track moving tissue targets and assist the data interpretation. We demonstrate that the USoP allows continuous tracking of physiological signals from tissues as deep as 164 mm. On mobile subjects, the USoP can continuously monitor physiological signals, including central blood pressure, heart rate and cardiac output, for as long as 12 h. This result enables continuous autonomous surveillance of deep tissue signals toward the internet-of-medical-things.


Subject(s)
Wearable Electronic Devices , Humans , Vital Signs
3.
Article in English | MEDLINE | ID: mdl-37878424

ABSTRACT

This perspective article provides a brief overview on materials, fabrications, beamforming, and applications for wearable ultrasound devices, a rapidly growing field with versatile implications. Recent developments in miniaturization and soft electronics have significantly advanced wearable ultrasound devices. Such devices offer distinctive advantages over traditional ultrasound probes, including prolonged usability and operator independence, and has demonstrated their effectiveness in continuous monitoring, non-invasive therapies, and advanced human-machine interfaces. Wearable ultrasound devices can be classified into three main categories: rigid, flexible, and stretchable, each having unique properties and fabrication strategies. Key unique strategies in device design, packaging, and beamforming for each type of wearable ultrasound devices are reviewed. Furthermore, we highlight the latest applications enabled by wearable ultrasound technology, encompassing continuous health monitoring, therapy, and human-machine interfaces. This article concludes by discussing the outstanding challenges within the field and outlines potential pathways for future advancements.

4.
Nature ; 613(7945): 667-675, 2023 01.
Article in English | MEDLINE | ID: mdl-36697864

ABSTRACT

Continuous imaging of cardiac functions is highly desirable for the assessment of long-term cardiovascular health, detection of acute cardiac dysfunction and clinical management of critically ill or surgical patients1-4. However, conventional non-invasive approaches to image the cardiac function cannot provide continuous measurements owing to device bulkiness5-11, and existing wearable cardiac devices can only capture signals on the skin12-16. Here we report a wearable ultrasonic device for continuous, real-time and direct cardiac function assessment. We introduce innovations in device design and material fabrication that improve the mechanical coupling between the device and human skin, allowing the left ventricle to be examined from different views during motion. We also develop a deep learning model that automatically extracts the left ventricular volume from the continuous image recording, yielding waveforms of key cardiac performance indices such as stroke volume, cardiac output and ejection fraction. This technology enables dynamic wearable monitoring of cardiac performance with substantially improved accuracy in various environments.


Subject(s)
Echocardiography , Equipment Design , Heart , Wearable Electronic Devices , Humans , Cardiac Output , Echocardiography/instrumentation , Echocardiography/standards , Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Stroke Volume , Wearable Electronic Devices/standards , Skin
SELECTION OF CITATIONS
SEARCH DETAIL