Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Publication year range
1.
J Biomater Appl ; 37(1): 33-39, 2022 07.
Article in English | MEDLINE | ID: mdl-35452336

ABSTRACT

Adding gentamicin to silk fibroin enhances both the antibacterial performance and degradation rate of silk-based materials. The increased material degradation rate can affect the strength of early internal fixation, resulting in internal fixation failure. This study sought to adjust the gentamicin concentration to control the material degradation rate, thereby better meeting clinical application requirements. The in vitro degradation, water absorption rate, and expansion rate of silk-based materials containing different gentamicin concentrations were studied. A gentamicin-loaded silk-based screw was implanted into the femurs of New Zealand rabbits. Micro-computed tomography was used to measure the screw diameter, which was then used to calculate the degradation rate. The specimens were stained with hematoxylin and eosin and Masson's trichrome. The in vitro results revealed increasing material degradation rates with increasing gentamicin concentration but no significant differences in water absorption rates with different gentamicin concentrations. The degradation rates of gentamicin-loaded (4 mg/g) silk-based rod-like materials were approximately 11.08% at three months in vitro and 9.4% in the animal experiment. The time for complete degradation was predicted from the fitting curve to be approximately 16 months. No inflammatory hyperplasia was observed in bone or soft tissue. The degradation and biocompatibility of the material containing 4 mg/g gentamicin meet clinical application requirements, and previous experimental results demonstrate good antibacterial performance of materials containing this gentamicin concentration.


Subject(s)
Fibroins , Silk , Animals , Anti-Bacterial Agents/pharmacology , Biocompatible Materials , Gentamicins , Rabbits , Water , X-Ray Microtomography
2.
Clin Anat ; 35(2): 178-185, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34704286

ABSTRACT

To evaluate the operating range and morphology of the surgical safe zone for oblique lumbar interbody fusion (OLIF). Twenty embalmed full-torso cadaveric specimens were dissected. The oblique corridor and the distance between adjacent lumbar arteries were measured in a static state and with psoas major retraction. The morphology and size of the safe zone for OLIF and the location of the lumbar sympathetic trunk were also recorded. The oblique corridor of the L1-L5 segments was significantly greater in the retracted state than in the static state (p < 0.05). With psoas major retraction, the distances between adjacent lumbar arteries at L1-4 were significantly greater (p < 0.05) than those in the static state. The lumbar sympathetic trunk is just located in the safe zone and travels downward adjacent to the psoas major. The shape of the safe zone for OLIF was approximately an oblique upward parallelogram at L1/2 and L2/3, an isosceles trapezoid at L3/4, and an irregular quadrangle or triangle at L4/5. The safe zone for OLIF at L1/2, L2/3, and L3/4 was significantly larger during retraction than in the static state (p < 0.05). On the lateral side of the lumbar spine there is a natural surgical safe zone for OLIF, which can provide a sufficient operating space. The safe zone has a certain morphological pattern in L1-5 segments and psoas major retraction can significantly enlarge it.


Subject(s)
Spinal Fusion , Cadaver , Humans , Lumbar Vertebrae/surgery , Lumbosacral Region , Psoas Muscles
3.
World Neurosurg ; 124: e633-e640, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30648611

ABSTRACT

BACKGROUND: Transforaminal percutaneous endoscopic lumbar discectomy (TF-PELD) is a minimally invasive technique with high radiation exposure. The purpose of this study was to compare radiation exposure of ultrasound-guided TF-PELD with fluoroscopy-guided TF-PELD. METHODS: In this prospective randomized controlled clinical trial, 60 patients with lumbar disc herniation were enrolled and randomly assigned to 2 groups (30 cases in each group): the ultrasound-guided group or the fluoroscopy-guided group. The radiation exposure, fluoroscopy time, and visual analog scale score were recorded. The number of possible operations per year within the yearly occupational exposure limit (OEL) was calculated. We also recorded the adverse events to evaluate the safety of ultrasound-guided TF-PELD. RESULTS: In 30 patients from the ultrasound-guided group, the lumbar disc structure was clearly visible under ultrasound guidance. The effective dose to surgeons and radiation dose to patients were 1.7 ± 0.4 and 25.2 ± 4.9 µSv in the ultrasound-guided group and 9.0 ± 2.5 and 127.4 ± 27.1 µSv in the fluoroscopy-guided group (P < 0.05), respectively. The fluoroscopy time was 2.6 ± 0.5 seconds in the ultrasound-guided group and 127.3 ± 29.5 seconds in the fluoroscopy-guided group (P < 0.05). A surgeon with shielding devices could treat 5556 cases per year in the fluoroscopy-guided group before exceeding the OEL for whole-body radiation, whereas they could treat 29,412 cases in the ultrasound-guided group. No difference between groups was detected in postoperative visual analog scale score (P > 0.58). No serious adverse event was found in any patient. CONCLUSIONS: Ultrasound-guided TF-PELD could decrease radiation exposure to surgeons and patients, without serious adverse events. It seems to be an acceptable alternative to fluoroscopy-guided TF-PELD.

4.
World Neurosurg ; 101: 658-665.e1, 2017 May.
Article in English | MEDLINE | ID: mdl-28342919

ABSTRACT

OBJECTIVE: To determine the radiation dose to the surgeon during ultrasound-assisted transforaminal percutaneous endoscopic lumbar discectomy (PELD) for lumbar disc herniation, and to investigate whether the usage of ultrasonography could reduce the radiation exposure to the surgeon. METHODS: The stages of needle insertion and foraminal plasty for transforaminal PELD were performed under ultrasound guidance and confirmed by fluoroscopy according to the standard technique by 2 spinal surgeons separately in 25 transforaminal PELDs (25 levels). The radiation exposure dose of the surgeons' chest above and below the shielding and the fluoroscopy time were recorded. The effective dose and number of possible levels per year within the yearly occupational exposure limit (OEL) were calculated. The radiation dose per level and fluoroscopy time between ultrasound-assisted PELD and fluoroscopy-assisted PELD were compared. RESULTS: The mean operation time and fluoroscopy time were 67.6 ± 14.6 minutes and 2.9 ± 0.7 seconds, respectively. The mean effective dose to the surgeons per level was 1.3 ± 0.6 µSv. One surgeon could perform PELDs at 38,462 levels per year without exceeding the OEL for whole-body radiation wearing a lead apron, and 1938 levels per year without using any shielding devices. Ultrasound-assisted PELD had significantly less radiation dose per level at the chest below and above apron, effective dose per level, and fluoroscopy time, compared with fluoroscopy-assisted PELD (all P < 0.05). CONCLUSIONS: The method of ultrasound-assisted needle insertion and foraminal plasty in transforaminal PELD can reduce radiation exposure to the surgeons compared with fluoroscopy-assisted PELD.


Subject(s)
Diskectomy, Percutaneous/methods , Intervertebral Disc Displacement/surgery , Occupational Exposure/prevention & control , Radiation Exposure/prevention & control , Surgeons , Ultrasonography, Interventional/adverse effects , Adolescent , Adult , Aged , Female , Humans , Intervertebral Disc Displacement/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Male , Middle Aged , Neuroendoscopy/methods , Prospective Studies , Surgeons/standards , Young Adult
5.
Zhongguo Gu Shang ; 22(9): 704-5, 2009 Sep.
Article in Chinese | MEDLINE | ID: mdl-19817210

ABSTRACT

OBJECTIVE: To evaluate the clinical outcome of posterior total vertebral resection in treating thoracic vertebrae tumor in order to provide a safe and effective method in rebuilding spine stability. METHODS: From 2002.1 to 2007.12, 18 patients with thoracic spine tumor underwent posterior total vertebral resection and internal fixation. Among the patients, 10 patients were male and 8 patients were female, ranging in age from 45 to 78 years, with an average of 56 years. The course of the diseases ranged from 2 to 13 months. After the operation, the tumor reccurence was monitored by X-ray, and the tumor markers were detected. RESULTS: All the patients were followed up for a period ranging from 12 to 60 months, averaged 29 months. All the patients showed a postoperative neurologic improvement, as well as showed radiographic evidence of solid fusion in the follow-up examinations during 3 to 9 months, with an average of (8 +/- 1.4) months. CONCLUSION: Posterior total vertebral resection for the treatment of thoracic spine tumor is safe and effective.


Subject(s)
Fracture Fixation, Internal/methods , Spinal Neoplasms/pathology , Spinal Neoplasms/surgery , Thoracic Vertebrae/pathology , Thoracic Vertebrae/surgery , Aged , Female , Humans , Male , Middle Aged , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...