N Engl J Med ; 386(17): 1591-1602, 2022 04 28.
Article in English | MEDLINE | ID: mdl-35240010

ABSTRACT

BACKGROUND: In the diagnosis of obstructive coronary artery disease (CAD), computed tomography (CT) is an accurate, noninvasive alternative to invasive coronary angiography (ICA). However, the comparative effectiveness of CT and ICA in the management of CAD to reduce the frequency of major adverse cardiovascular events is uncertain. METHODS: We conducted a pragmatic, randomized trial comparing CT with ICA as initial diagnostic imaging strategies for guiding the treatment of patients with stable chest pain who had an intermediate pretest probability of obstructive CAD and were referred for ICA at one of 26 European centers. The primary outcome was major adverse cardiovascular events (cardiovascular death, nonfatal myocardial infarction, or nonfatal stroke) over 3.5 years. Key secondary outcomes were procedure-related complications and angina pectoris. RESULTS: Among 3561 patients (56.2% of whom were women), follow-up was complete for 3523 (98.9%). Major adverse cardiovascular events occurred in 38 of 1808 patients (2.1%) in the CT group and in 52 of 1753 (3.0%) in the ICA group (hazard ratio, 0.70; 95% confidence interval [CI], 0.46 to 1.07; P = 0.10). Major procedure-related complications occurred in 9 patients (0.5%) in the CT group and in 33 (1.9%) in the ICA group (hazard ratio, 0.26; 95% CI, 0.13 to 0.55). Angina during the final 4 weeks of follow-up was reported in 8.8% of the patients in the CT group and in 7.5% of those in the ICA group (odds ratio, 1.17; 95% CI, 0.92 to 1.48). CONCLUSIONS: Among patients referred for ICA because of stable chest pain and intermediate pretest probability of CAD, the risk of major adverse cardiovascular events was similar in the CT group and the ICA group. The frequency of major procedure-related complications was lower with an initial CT strategy. (Funded by the European Union Seventh Framework Program and others; DISCHARGE ClinicalTrials.gov number, NCT02400229.).


Subject(s)
Coronary Angiography , Coronary Artery Disease , Tomography, X-Ray Computed , Angina Pectoris/diagnostic imaging , Angina Pectoris/etiology , Chest Pain/diagnostic imaging , Chest Pain/etiology , Coronary Angiography/adverse effects , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Female , Humans , Male , Tomography, X-Ray Computed/adverse effects
2.
Eur Radiol ; 30(4): 1997-2009, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31844958

ABSTRACT

OBJECTIVE: To implement detailed EU cardiac computed tomography angiography (CCTA) quality criteria in the multicentre DISCHARGE trial (FP72007-2013, EC-GA 603266), we reviewed image quality and adherence to CCTA protocol and to the recommendations of invasive coronary angiography (ICA) in a pilot study. MATERIALS AND METHODS: From every clinical centre, imaging datasets of three patients per arm were assessed for adherence to the inclusion/exclusion criteria of the pilot study, predefined standards for the CCTA protocol and ICA recommendations, image quality and non-diagnostic (NDX) rate. These parameters were compared via multinomial regression and ANOVA. If a site did not reach the minimum quality level, additional datasets had to be sent before entering into the final accepted database (FADB). RESULTS: We analysed 226 cases (150 CCTA/76 ICA). The inclusion/exclusion criteria were not met by 6 of the 226 (2.7%) datasets. The predefined standard was not met by 13 of 76 ICA datasets (17.1%). This percentage decreased between the initial CCTA database and the FADB (multinomial regression, 53 of 70 vs 17 of 75 [76%] vs [23%]). The signal-to-noise ratio and contrast-to-noise ratio of the FADB did not improve significantly (ANOVA, p = 0.20; p = 0.09). The CTA NDX rate was reduced, but not significantly (initial CCTA database 15 of 70 [21.4%]) and FADB 9 of 75 [12%]; p = 0.13). CONCLUSION: We were able to increase conformity to the inclusion/exclusion criteria and CCTA protocol, improve image quality and decrease the CCTA NDX rate by implementing EU CCTA quality criteria and ICA recommendations. KEY POINTS: • Failure to meet protocol adherence in cardiac CTA was high in the pilot study (77.6%). • Image quality varies between sites and can be improved by feedback given by the core lab. • Conformance with new EU cardiac CT quality criteria might render cardiac CTA findings more consistent and comparable.


Subject(s)
Computed Tomography Angiography/methods , Coronary Angiography/methods , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Female , Humans , Male , Middle Aged , Pilot Projects , Reproducibility of Results