Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters











Database
Language
Publication year range
2.
Vasc Endovascular Surg ; 45(3): 295-8, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21278174

ABSTRACT

Spontaneous superior mesenteric artery dissection is rare and presents with variable symptomatology. Optimal treatment depends on the presentation; asymptomatic patients can be managed expectantly. Endoluminal intervention or open reconstruction is warranted in patients with persistent symptoms or intestinal ischemia. As more of these patients are identified with increasing utilization of computed tomography (CT), our understanding of the pathophysiology and best treatment will improve.


Subject(s)
Aortic Dissection/therapy , Endovascular Procedures , Mesenteric Artery, Superior/surgery , Saphenous Vein/transplantation , Vascular Grafting , Abdominal Pain/etiology , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Endovascular Procedures/instrumentation , Female , Humans , Mesenteric Artery, Superior/diagnostic imaging , Middle Aged , Stents , Tomography, X-Ray Computed , Treatment Outcome
4.
J Vasc Surg ; 51(3): 616-21, 621.e1-3, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20110154

ABSTRACT

BACKGROUND: Little is known about the significance of blood transfusion in patients with peripheral arterial disease. We queried the American College of Surgeons National Surgical Quality Improvement Program (ACS NSQIP) database to examine the effect of intraoperative blood transfusion on the morbidity and mortality in patients who underwent lower extremity revascularization. METHODS: We analyzed data from the participant use data file containing vascular surgical cases submitted to the ACS NSQIP in 2005, 2006, and 2007 by 173 hospitals. Current procedural terminology codes were used to select lower extremity procedures that were grouped into venous graft, prosthetic graft, or thromboendarterectomy. Thirty-day outcomes analyzed were (1) mortality, (2) composite morbidity, (3) graft/prosthesis failure, (4) return to the operating room within 30 days, (5) wound occurrences, (6) sepsis or septic shock, (7) pulmonary occurrences, and (8) renal insufficiency or failure. Intraoperative transfusion of packed red blood cells was categorized as none, 1 to 2 units, and 3 or more units. Outcome rates were compared between the transfused and nontransfused groups using the chi(2) test and multivariable regression adjusting for transfusion propensity, comorbid and procedural risk. RESULTS: A total of 8799 patients underwent lower extremity revascularization between 2005 and 2007. Mean age was 66.8 +/- 12.0 years and 5569 (63.3%) were male. Transfusion rates ranged from 14.5% in thromboendarterectomy patients to 27.1% in prosthetic bypass patients (P < .05). After adjustment for transfusion propensity and patient and procedural risks, transfusion of 1 or 2 units remained significantly predictive of mortality, composite morbidity, sepsis/shock, pulmonary occurrences, and return to the operating room. The adjusted odds ratios for 30-day mortality ranged from 1.92 (95% confidence interval [CI] 1.36-2.70) for 1 to 2 units to 2.48 (95% CI 1.55-3.98) for 3 or more units. CONCLUSION: In a large number of patients undergoing lower extremity revascularization, we have found that there is a higher risk of postoperative mortality, pulmonary, and infectious complications after receiving intraoperative blood transfusion. Additional studies are necessary to better define transfusion triggers that balance the risk/benefit ratio for blood transfusion.


Subject(s)
Blood Loss, Surgical/prevention & control , Erythrocyte Transfusion/adverse effects , Lower Extremity/blood supply , Peripheral Vascular Diseases/surgery , Vascular Surgical Procedures/adverse effects , Aged , Blood Loss, Surgical/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Chi-Square Distribution , Databases as Topic , Endarterectomy/adverse effects , Erythrocyte Transfusion/mortality , Female , Hematocrit , Humans , Kidney Diseases/etiology , Logistic Models , Lung Diseases/etiology , Male , Middle Aged , Odds Ratio , Patient Selection , Peripheral Vascular Diseases/mortality , Prosthesis Failure , Reoperation , Risk Assessment , Risk Factors , Shock, Septic/etiology , Surgical Wound Infection/etiology , Thrombectomy/adverse effects , Thrombectomy/mortality , Time Factors , Treatment Outcome , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/mortality , Veins/transplantation
5.
Eur J Cardiothorac Surg ; 35(2): 282-6, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19081731

ABSTRACT

Rupture of thoracic aneurysm, acute type B dissection, blunt thoracic trauma, and penetrating aortic ulcer can present with a similar clinical profile of thoracic aortic rupture. We report a meta-analysis of comparative studies evaluating endoluminal graft versus open repair of these lesions as well as the early experience from our institution. We searched the following databases for reports of endovascular versus open repair of acute descending thoracic aortic rupture: Medline/PubMed, OVID, EMBASE, CINAHL, ClinicalTrials.gov, the Cochrane central register of controlled trials and the Cochrane database of systematic reviews. We used the random-effects model to calculate the odds ratio (OR) and 95% confidence intervals (CI) for mortality, paraplegia/paraparesis and stroke rates. Also, the medical records of the patients treated in our institution with this technique from 2000 to 2008 were reviewed. Demographics, comorbidities and operative procedure information were retrieved. Outcomes examined were mortality, paraplegia and stroke. Meta-analysis indicates that endoluminal graft repair is accompanied by lower procedure related mortality (OR 0.46, 95% CI 0.26-0.78, p=0.005) and paraplegia rates (OR 0.23, 95% CI 0.08-0.65, p=0.005), as compared to open repair. There was no difference in stroke rate between the two methods (OR 0.86, 95% CI 0.26-2.8, p=0.8). We have treated 13 patients with endoluminal stent-grafts. No conversion to open repair was necessary. Stroke rate was 15%, no patient died as a result of the stent-graft placement, one patient died as a result of massive head injury (overall 30-day mortality: 7.5%). There were no spinal cord ischemic complications. Our experience and meta-analysis indicate that thoracic endograft repair has low mortality and spinal cord complication rates for treatment of acute thoracic aortic rupture. If this method proves to be durable, it could replace open repair as the treatment of choice for these critically ill patients.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Rupture/surgery , Blood Vessel Prosthesis Implantation/methods , Minimally Invasive Surgical Procedures/methods , Adolescent , Adult , Aged , Aortic Dissection/surgery , Aorta, Thoracic/injuries , Aorta, Thoracic/surgery , Female , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL