Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Respiration ; 101(3): 299-306, 2022.
Article in English | MEDLINE | ID: mdl-34724670

ABSTRACT

BACKGROUND: Transbronchial cryobiopsy (TBCB) is increasingly being identified as a potential alternative for the diagnosis of interstitial lung disease (ILD). The specimen size of TBCB is positively related to the freezing time. However, the proper initial freezing time for the clinical application of TBCB in ILD remains unknown. METHODS: A prospective randomized parallel group study was employed to investigate ILD patients with unclear diagnosis, who were admitted to the First Affiliated Hospital of Guangzhou Medical University from May 2019 to October 2020 and required TBCB. All patients were randomly divided into 4 groups according to the different freezing times of TBCB: 3 s, 4 s, 5 s, and 6 s groups. All operations were performed under intravenous anesthesia with endotracheal intubation, 60-65 bar pressure of freezing gas source, and 1.9-mm cryoprobe. Compare differences among groups in specimen size, complications, pathological diagnosis efficiency, and multidisciplinary discussion (MDD) diagnostic efficiency. RESULTS: A total of 100 patients were recruited and randomly assigned into 4 groups (n = 25 each group). The specimen sizes of TBCB in ILD were positively correlated with the freezing time (r = 0.639, p < 0.05). None of the patients experienced Grade 3 severe bleeding. Pneumothorax occurred in 1 patient in the 4 s, 5 s, and 6 s groups, respectively. The diagnostic yield of MDD in the 3 s, 4 s, 5 s, and 6 s groups were 64%, 88%, 88%, and 96%, respectively (p < 0.05), but showing no significant differences among 4 s, 5 s, and 6 s groups. CONCLUSIONS: The specimen size and diagnostic efficiency of TBCB in ILD increased with a longer freezing time. When the freezing gas pressure is 60-65 bar, we recommended 4 s as the initial freezing time of TBCB, and this time is associated with high diagnostic efficiency and low incidence of complications.


Subject(s)
Bronchoscopy , Lung Diseases, Interstitial , Biopsy , Freezing , Humans , Lung/pathology , Lung Diseases, Interstitial/diagnosis , Lung Diseases, Interstitial/pathology , Prospective Studies
2.
J Thorac Dis ; 13(4): 2099-2105, 2021 Apr.
Article in English | MEDLINE | ID: mdl-34012560

ABSTRACT

BACKGROUND: Transbronchial cryobiopsy (TBCB) is an option to surgical biopsy for the diagnosis in interstitial lung diseases. Several impact factors have received wide attention, including the freezing time, cryoprobe size, and contact pressure. However, the effect of the applied gas pressure on the specimen size has not been well elucidated. The purpose of this study is to investigate the effect of the applied gas pressure on the TBCB specimen size. METHODS: Cryoprobes with a diameter of 1.9 mm were used to perform TBCB on 4 beagle canines under general anesthesia. TBCB was performed with a total of 16 time-pressure combinations that were randomly combined with 4 freezing times (3, 4, 5, and 6 s) and 4 gas pressures (40, 50, 55, and 60 bar). For each combination, 8 biopsies were performed. The size and quality of specimens, as well as complications, were evaluated. RESULTS: A total of 128 TBCB specimens were obtained. With the same freezing time, the specimen sizes obtained by different applied gas pressures were significantly different (P<0.05) and positively correlated with the gas pressures (r: 0.797-0.867). With the same gas pressure, the size of the TBCB specimens was positively correlated with the freezing time (r: 0.503-0.752). In the 40-bar group, no tissues were obtained when the freezing times were 3-5 s. In the 50-bar and 55-bar groups, qualified specimens were obtained when the freezing times were 5 and 6 s. In the 60-bar group, qualified specimens were obtained when the freezing times were 3-6 s. CONCLUSIONS: The TBCB specimen size was positively correlated with the applied gas pressure. The applied gas pressure contributed to the sample size and quality. To obtain qualified specimens with a 1.9-mm cryoprobe during TBCB, the lowest limit of the normal working gas pressure range should be increased to greater than 50 bar.

SELECTION OF CITATIONS
SEARCH DETAIL