Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 411
Filter
1.
Chin Med J (Engl) ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38958034

ABSTRACT

BACKGROUND: Carotid intima-media thickness (IMT) and diameter, stiffness, and wave reflections, are independent and important clinical biomarkers and risk predictors for cardiovascular diseases. The purpose of the present study was to establish nationwide reference values of carotid properties for healthy Chinese adults and to explore potential clinical determinants. METHODS: A total of 3053 healthy Han Chinese adults (1922 women) aged 18-79 years were enrolled at 28 collaborating tertiary centers throughout China between April 2021 and July 2022. The real-time tracking of common carotid artery walls was achieved by the radio frequency (RF) ultrasound system. The IMT, diameter, compliance coefficient, ß stiffness, local pulse wave velocity (PWV), local systolic blood pressure, augmented pressure (AP), and augmentation index (AIx) were then automatically measured and reported. Data were stratified by age groups and sex. The relationships between age and carotid property parameters were analyzed by Jonckheere-Terpstra test and simple linear regressions. The major clinical determinants of carotid properties were identified by Pearson's correlation, multiple linear regression, and analyses of covariance. RESULTS: All the parameters of carotid properties demonstrated significantly age-related trajectories. Women showed thinner IMT, smaller carotid diameter, larger AP, and AIx than men. The ß stiffness and PWV were significantly higher in men than women before forties, but the differences reversed after that. The increase rate of carotid IMT (5.5 µm/year in women and 5.8 µm/year in men) and diameter (0.03 mm/year in both men and women) were similar between men and women. For the stiffness and wave reflections, women showed significantly larger age-related variations than men as demonstrated by steeper regression slopes (all P for age by sex interaction <0.05). The blood pressures, body mass index (BMI), and triglyceride levels were identified as major clinical determinants of carotid properties with adjustment of age and sex. CONCLUSIONS: The age- and sex-specific reference values of carotid properties measured by RF ultrasound for healthy Chinese adults were established. The blood pressures, BMI, and triglyceride levels should be considered for clinical application of corresponding reference values.

4.
Digit Health ; 10: 20552076241260557, 2024.
Article in English | MEDLINE | ID: mdl-38882253

ABSTRACT

Background: Left ventricular opacification (LVO) improves the accuracy of left ventricular ejection fraction (LVEF) by enhancing the visualization of the endocardium. Manual delineation of the endocardium by sonographers has observer variability. Artificial intelligence (AI) has the potential to improve the reproducibility of LVO to assess LVEF. Objectives: The aim was to develop an AI model and evaluate the feasibility and reproducibility of LVO in the assessment of LVEF. Methods: This retrospective study included 1305 echocardiography of 797 patients who had LVO at the Department of Ultrasound Medicine, Union Hospital, Huazhong University of Science and Technology from 2013 to 2021. The AI model was developed by 5-fold cross validation. The validation datasets included 50 patients prospectively collected in our center and 42 patients retrospectively collected in the external institution. To evaluate the differences between LV function determined by AI and sonographers, the median absolute error (MAE), spearman correlation coefficient, and intraclass correlation coefficient (ICC) were calculated. Results: In LVO, the MAE of LVEF between AI and manual measurements was 2.6% in the development cohort, 2.5% in the internal validation cohort, and 2.7% in the external validation cohort. Compared with two-dimensional echocardiography (2DE), the left ventricular (LV) volumes and LVEF of LVO measured by AI correlated significantly with manual measurements. AI model provided excellent reliability for the LV parameters of LVO (ICC > 0.95). Conclusions: AI-assisted LVO enables more accurate identification of the LV endocardium and reduces observer variability, providing a more reliable way for assessing LV function.

5.
J Thorac Dis ; 16(5): 3117-3128, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38883679

ABSTRACT

Background: Left atrioventricular valvular regurgitation (LAVVR) recurrence after partial and transitional atrioventricular septal defect (AVSD) repair is the main risk factor associated with reoperation or mortality. The purpose of this study was to identify risk factors associated with the recurrence of LAVVR after surgical repair of transitional and partial AVSD at a single institution. Methods: A hundred and fifty-seven patients who underwent anatomical repair for partial and transitional AVSD from January 2013 to December 2021 were included in our institutional database. Demographic characteristics, operative information, comorbidities, complications, and outcomes were retrieved from electronic medical records. Echocardiographic evaluations included cardiac dimensions, the degree of LAVVR, and the anatomy of the atrioventricular valve. Results: After a median follow-up period of 5.8 years, 40 patients had recurrent moderate or even more severe LAVVR. Compared with patients without recurrent LAVVR, those experiencing LAVVR recurrence were more likely to have larger preoperative left atrial (LA) size and larger left ventricular (LV) size after standardization, larger left atrioventricular valve (LAVV) cleft width, higher proportions of preoperative moderate or even more severe LAVVR, and immediately postoperative mild to moderate or even more severe LAVVR. Univariate Cox regression analysis showed that age at first repair, height, LA size after standardization, LV size after standardization, the severity of preoperative LAVVR, immediately postoperative LAVVR, and the LAVV cleft width more than 1cm were risk factors for recurrent LAVVR (P<0.05 for all). Multivariable Cox regression analysis showed that mild to moderate or even more severe LAVVR postoperatively [hazard ratio (HR) 9.53, 95% confidence interval (CI): 3.78-24.01; P<0.001], the width of LAVV cleft more than 1 cm (HR: 3.90, 95% CI: 1.80-8.48; P<0.001) and age at first repair (HR: 0.45, 95% CI: 0.31-0.66; P<0.001) were independently associated with the recurrence of LAVVR. Conclusions: The width of LAVV cleft, mild to moderate or even more severe LAVVR immediately after surgery, and age at initial surgery are risk factors for recurrent LAVVR. The presence of recurrent LAVVR necessitates proactive surveillance to facilitate timely reintervention.

7.
Diagnostics (Basel) ; 14(12)2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38928685

ABSTRACT

As an integral part of the mitral valve apparatus, the left ventricle papillary muscle (PM) controls mitral valve closure during systole and participates in the ejection process during left ventricular systole. Mitral regurgitation (MR) is the most immediate and predominant result when the PM is structurally or functionally abnormal. However, dysfunction of the PM is easily underestimated or overlooked in clinical interventions for MR-related diseases. Therefore, adequate recognition of PM dysfunction and PM-derived MR is critical. In this review, we systematically describe the normal anatomical variations in the PM and the pathophysiology of PM dysfunction-related diseases and summarize the commonly used parameters and the advantages and disadvantages of various noninvasive imaging modalities for the structural and functional assessment of the PM.

8.
Diagnostics (Basel) ; 14(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38928720

ABSTRACT

Heart transplantation (HT) is the mainstream therapy for end-stage heart disease. However, the cardiac graft function can be affected by several factors. It is important to monitor HT patients for signs of graft dysfunction. Transthoracic echocardiography is a simple, first-line, and non-invasive method for the assessment of cardiac function. The emerging speckle-tracking echocardiography (STE) could quickly and easily provide additive information over traditional echocardiography. STE longitudinal deformation parameters are markers of early impairment of ventricular function. Although once called the "forgotten ventricle", right ventricular (RV) assessment has gained attention in recent years. This review highlights the potentially favorable role of STE in assessing RV systolic function in clinically well HT patients.

10.
World J Urol ; 42(1): 302, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38720010

ABSTRACT

PURPOSE: To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ-CEUS) by comparing with contrast-enhanced computed tomography (CE-CT) and contrast-enhanced magnetic resonance imaging (CE-MRI) for differentiating benign and malignant renal masses. MATERIALS AND METHODS: 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ-CEUS, CE-CT or CE-MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar's test. RESULTS: In the head-to-head comparison, SNZ-CEUS and CE-MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ-CEUS and CE-CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ-CEUS had relatively lower than specificity than CE-CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE-MRI demonstrated higher specificity than SNZ-CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. CONCLUSIONS: SNZ-CEUS, CE-CT, and CE-MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ-CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.


Subject(s)
Contrast Media , Ferric Compounds , Iron , Kidney Neoplasms , Magnetic Resonance Imaging , Oxides , Tomography, X-Ray Computed , Ultrasonography , Humans , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Male , Female , Middle Aged , Prospective Studies , Ultrasonography/methods , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Aged , Diagnosis, Differential , Adult , Aged, 80 and over
11.
Adv Sci (Weinh) ; : e2309907, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696589

ABSTRACT

Myocardial ischemia/reperfusion injury (MIRI) is the leading cause of irreversible myocardial damage. A pivotal pathogenic factor is ischemia/reperfusion (I/R)-induced cardiomyocyte ferroptosis, marked by iron overload and lipid peroxidation. However, the impact of lipid droplet (LD) changes on I/R-induced cardiomyocyte ferroptosis is unclear. In this study, an aggregation-induced emission probe, TPABTBP is developed that is used for imaging dynamic changes in LD during myocardial I/R-induced ferroptosis. TPABTBP exhibits excellent LD-specificity, superior capability for monitoring lipophagy, and remarkable photostability. Molecular dynamics (MD) simulation and super-resolution fluorescence imaging demonstrate that the TPABTBP is specifically localized to the phospholipid monolayer membrane of LDs. Imaging LDs in cardiomyocytes and myocardial tissue in model mice with MIRI reveals that the LD accumulation level increase in the early reperfusion stage (0-9 h) but decrease in the late reperfusion stage (>24 h) via lipophagy. The inhibition of LD breakdown significantly reduces the lipid peroxidation level in cardiomyocytes. Furthermore, it is demonstrated that chloroquine (CQ), an FDA-approved autophagy modulator, can inhibit ferroptosis, thereby attenuating MIRI in mice. This study describes the dynamic changes in LD during myocardial ischemia injury and suggests a potential therapeutic target for early MIRI intervention.

12.
Echocardiography ; 41(5): e15835, 2024 May.
Article in English | MEDLINE | ID: mdl-38784978

ABSTRACT

PURPOSE: There is currently limited information on the utility of transthoracic echocardiography (TTE)-derived Doppler parameters for assessing bioprosthetic tricuspid valve (BTV) dysfunction. Our study aimed to establish the precision and appropriate reference ranges for routinely collected transthoracic Doppler parameters in the assessment of BTV dysfunction. METHODS: We retrospectively evaluated 100 BTV patients who underwent TTE. Based on redo surgical confirmation or more than 2 repeat TTE or transesophageal echocardiography (TEE) examinations, patients were allocated to normal (n = 61), regurgitant (n = 24), or stenotic (n = 15) BTV group. Univariate and multivariate binary logistic regression were performed to identify TTE Doppler parameters that detected BTV dysfunction. RESULTS: The VTI ratio (VTITV/VTILVOT) was the most accurate Doppler parameter for detecting BTV dysfunction, with a ratio of >2.8 showing 84.6% sensitivity and 90.2% specificity. VTI ratio > 3.2, mean gradient (MGTV) > 6.2 mmHg and pressure half-time > 218 ms detected significant BTV stenosis, with sensitivities of 100%, 93.3% and 93.3% and specificities of 82.4%, 75.3% and 87.1%, respectively. After multivariate analysis, the VTI ratio > 2.8 (OR = 9.00, 95% CI = 2.13-41.61, p = .003) and MGTV > 5.1 mmHg (OR = 6.50, 95% CI = 1.69-27.78, p = .008) were the independent associations of BTV dysfunction. With these cutoff values, 75.0%-92.2% of normal and 62.5%-96.0% of dysfunctional BTV were identified. CONCLUSIONS: Doppler parameters from TTE can accurately identify BTV dysfunction, particularly with VTI ratio > 2.8 and MGTV > 5.1 mmHg, to assess the need for additional testing with TEE.


Subject(s)
Bioprosthesis , Echocardiography, Doppler , Heart Valve Prosthesis , Sensitivity and Specificity , Tricuspid Valve , Humans , Female , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/physiopathology , Middle Aged , Echocardiography, Doppler/methods , Retrospective Studies , Reproducibility of Results , Aged , Tricuspid Valve Insufficiency/physiopathology , Tricuspid Valve Insufficiency/diagnostic imaging
13.
Asian J Surg ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38729876
14.
Echocardiography ; 41(4): e15809, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38581298

ABSTRACT

BACKGROUND: Tissue motion of mitral annular displacement (TMAD) assessment has proved to be an effective method for several cardiovascular diseases including hypertrophic cardiomyopathy, heart failure, non-ST-elevation myocardial infarction, etc. However, there are no studies exploring the feasibility of TMAD in heart transplantation (HT) recipients, and the predictive value of this parameter for adverse outcomes in these patients remains unknown. Consequently, this study aimed to evaluate the feasibility of TMAD in the evaluation of left ventricular (LV) systolic function in clinically well adult HT patients, and further investigate the prognostic value of TMAD. METHODS: Echocardiography was performed in 155 adult HT patients and 49 healthy subjects. All the subjects were examined by conventional transthoracic two-dimensional echocardiography and two-dimensional speckle tracking echocardiography (2D-STE) with evaluation of the LV end-diastolic diameter, LV end-diastolic volume index, LV end-systolic volume index, interventricular septal thickness, left atrial diameter, mitral annular plane systolic excursion (MAPSE), LV ejection fraction (LVEF), TMAD and LV global longitudinal strain (LVGLS). The end point was defined as all-causes mortality or posttransplant related hospitalization during follow up. Cox proportional hazards regression was performed to evaluate the prognostic value of the parameters for predicting poor outcomes in HT patients. RESULTS: A significant positive correlation was found between the measurements of TMAD and LVGLS (r = .714, p < .001). TMAD obtained by 2D-STE had good reproducibility. The LVGLS and TMAD were significantly lower in HT group than in control group (both p < .001). In HT patients, compared with event free group, adverse outcome group displayed reduced TMAD and LVGLS, and elevated age (p < .001, < .001, = .017, respectively). Patients with higher TMAD (> 9.1 mm) had comparatively better survival when stratified by cutoff value (log-rank p < .001). LVGLS and TMAD were independently associated with adverse outcomes in multivariable analysis (both p < .001). CONCLUSION: Assessment of TMAD is effective for evaluating LV longitudinal systolic function and predicting adverse outcomes in clinically well adult HT patients.


Subject(s)
Cardiomyopathy, Hypertrophic , Heart Transplantation , Ventricular Dysfunction, Left , Adult , Humans , Prognosis , Reproducibility of Results , Feasibility Studies , Ventricular Function, Left
15.
Int J Pharm ; 656: 124074, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38565406

ABSTRACT

Tacrolimus (FK506) is an effective therapeutic for transplant rejection in clinical practice, primarily inhibiting rejection by suppressing the activation and proliferation of allogeneic T cells in the lymph nodes (LNs). However, conventional administration methods face challenges in directly delivering free FK506 to the LNs. In this study, we introduce a novel LN-targeted delivery system based on mesoporous silica nanoparticles (MSNs-FK506-MECA79). These particles were designed to selectively target high endothelial venules in LNs; this was achieved through surface modification with MECA79 antibodies. Their mean size and zeta potential were 201.18 ± 5.98 nm and - 16.12 ± 0.36 mV, respectively. Our findings showed that MSNs-FK506-MECA79 could accumulate in LNs and increase the local concentration of FK506 from 28.02 ± 7.71 ng/g to 123.81 ± 76.76 ng/g compared with the free FK506 treatment group. Subsequently, the therapeutic efficacy of MSNs-FK506-MECA79 was evaluated in a skin transplantation model. The treatment with MSNs-FK506-MECA79 could lead to a decrease in the infiltration of T cells in the grafts, a reduction in the grade of rejection, and a significant prolongation of survival. Consequently, this study presents a promising strategy for the active LN-targeted delivery of FK506 and improving the immunotherapeutic effects on transplant rejection.


Subject(s)
Graft Rejection , Immunosuppressive Agents , Lymph Nodes , Nanoparticles , Silicon Dioxide , Tacrolimus , Tacrolimus/administration & dosage , Tacrolimus/chemistry , Silicon Dioxide/chemistry , Graft Rejection/prevention & control , Graft Rejection/immunology , Animals , Lymph Nodes/drug effects , Lymph Nodes/immunology , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/chemistry , Immunosuppressive Agents/pharmacology , Porosity , Mice, Inbred BALB C , Skin Transplantation/methods , Male , Mice , Mice, Inbred C57BL , Drug Delivery Systems/methods , Drug Carriers/chemistry
20.
J Am Heart Assoc ; 13(6): e032402, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38456455

ABSTRACT

BACKGROUND: Right ventricular longitudinal shortening fraction (RVLSF) is a 2-dimensional speckle tracking echocardiography parameter based on tricuspid annular displacement analysis that could be used to assess right ventricular (RV) systolic function. The value of RVLSF in the assessment of RV systolic function in recipients of heart transplantation (HT) and whether RVLSF can replace strain parameters remains unknown. METHODS AND RESULTS: A total of 153 adult patients who underwent HT were consecutively enrolled in this prospective longitudinal study. All subjects were examined by conventional transthoracic 2-dimensional echocardiography and 2-dimensional speckle tracking echocardiography to evaluate the RV end-diastolic basal diameter, RV end-diastolic area, fractional area change, peak systolic velocity of tricuspid annulus, tricuspid annular plane systolic excursion, RV free wall strain, and RVLSF. Cox proportional hazards regression was used to test if the parameters of interest had independent prognostic value for adverse outcome prediction in patients who underwent HT. A significant positive correlation was found between the measurements of RVLSF and RV free wall strain (r=0.927, P<0.001). Compared with the event-free group, the adverse outcome group displayed reduced RVLSF and RV free wall strain and higher age (P<0.001, <0.001, =0.016, respectively) in patients who underwent HT. RVLSF and RV free wall strain were independently associated with poor prognosis in multivariable analysis (both P<0.001). CONCLUSIONS: RVLSF assessment provides an effective evaluation of RV longitudinal systolic function in the transplanted hearts and has prognostic value for adverse outcomes in patients undergoing HT.


Subject(s)
Heart Transplantation , Ventricular Dysfunction, Right , Adult , Humans , Prospective Studies , Prognosis , Feasibility Studies , Longitudinal Studies , Ventricular Function, Right , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...