1.
J Shoulder Elbow Surg ; 33(5): e248-e260, 2024 May.
Article in English | MEDLINE | ID: mdl-38182026

ABSTRACT

BACKGROUND: Traumatic coronoid deficiency with persistent elbow instability is a challenging condition. Autologous bone graft reconstruction is often associated with a range of additional clinical problems and the outcome is often unpredictable. The purpose of this study was to design a prosthetic device that can reconstruct coronoid deficiency of any height and to evaluate its mechanical properties using finite element analysis. MATERIALS AND METHODS: A customized coronoid prosthesis was designed based on image registration, automatic measurement, and computer-aided design. After pilot study and sample size calculation, image data collected from 6 patients who underwent bilateral complete upper extremity CT scans were reconstructed. The test was divided into 3 groups: coronoid intact, prosthesis and autograft. Regan-Morrey type II and autologous olecranon osteotomy models were established. The prosthesis and autogenous olecranon were assembled to the coronoid base. Stress was applied axially along the proximal humeral diaphysis and implant micromotion and contact mechanics of the humeroulnar joint were measured at 30°, 45°, 60° and 90° of joint flexion respectively. RESULTS: At all flexion angles, the maximum stress on the coronoid articular surface was significantly reduced in the prosthesis and autograft groups, with the reduction being more significant in the latter (P < .001). With increasing flexion, the maximum stress at the coronoid articular surface increased significantly after autograft reconstruction (7.2 to 68 MPa, P < .001), whereas the humeroulnar joint obtained a similar contact mechanics pattern to that of the control group after prosthetic reconstruction. As the flexion angle increased, the relative micromotion of both the prosthesis and autograft increased significantly (0.5-1.6 vs. 0.2-1.2, Pmeasure time < 0.001, Pgroups < 0.001). Contact pressure and center-of-force paths of the humeroulnar joint experience abrupt stress changes at approximately 60° of flexion. CONCLUSION: The contact stress pattern in the humeroulnar joint is similar in prosthesis and intact coronoid groups. Autograft reconstruction increases contact stresses at the articular surface and alters the joint center-of-force path. The "stress surge phenomenon" in the humeroulnar joint surface before and after 60° of flexion may be one of the mechanisms of traumatic elbow degeneration.


Subject(s)
Elbow Joint , Joint Instability , Humans , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Joint Instability/diagnostic imaging , Joint Instability/etiology , Joint Instability/surgery , Finite Element Analysis , Pilot Projects , Prostheses and Implants , Range of Motion, Articular
2.
Front Bioeng Biotechnol ; 11: 1141790, 2023.
Article in English | MEDLINE | ID: mdl-36923459

ABSTRACT

Purpose: This study aimed to investigate the biomechanical performance of three Ti6Al4V volar plates with the latest designs using a finite element model. Methods: An AO type 23-A3 distal radius fracture and the models of T plate (2.4 mm LCP Volar Distal Radius Plate), V plate (2.4 mm LCP Two-Column Volar Distal Radius Plate) and π Plate (2.4 mm Volar Rim Distal Radius Plate) (all from Depuy Synthes, West Chester, PA, USA, Ti6Al4V) were built in 3D-matic software. After assembling the internal fixation and fractures, we imported these models into the finite element analysis software (ABAQUS). An axial loading of 100 N was added to the distal end of each model. The displacements of total models and implants, the principal strains and the von Mises stresses in the plates were calculated and compared to capture the biomechanical features of the three plates. Results: The T plate, V plate and π plate represented a model displacement of 0.8414 mm, 1.134 mm and 1.936 mm, respectively. The T plate was with the implant displacement of 0.7576 mm, followed by the V plate (0.8802 mm) and the π plate (1.545 mm). The T plate had the smallest principal strain of 0.23%, the V plate showed an intermediate level of 0.28%, and the π plate had a value of 0.72%. The least peak von Mises stress was observed in the V plate with 263.6MPa, and this value was 435.6 MPa and 1050 MPa in the T plate and π plate, respectively. Conclusion: The biomechanical features of three Ti6Al4V volar locking plates in an AO type 23-A3 fracture were described in our analysis. The T plate and the V plate showed similar biomechanical performance while the π plate represented worse performance than the other two plates.

3.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-991381

ABSTRACT

Military vocational education has become one of the strategies to strengthen the military in the new era. The army urgently needs to build a number of featured online courses of military vocational education. Therefore, taking the course "Knowledge and Skills of Health Education for the Army" as an example, this paper discusses the overall construction objectives, construction ideas, teaching content, curriculum and test question bank construction of the course. In addition, this paper analyzes and summarizes the problems existing in the teaching organization, implementation, and preliminary application, so as to provide ideas and construction strategies for the construction of online open courses in other military vocational education.

4.
Orthop Surg ; 14(11): 3047-3060, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36177864

ABSTRACT

OBJECTIVE: The mechanical high modulus structure of the proximal femur could guide clinical surgical treatment and instrument design of proximal femoral fractures. The purpose of this study is to analyze and verify the mechanical structure of the proximal femur. METHODS: A total of 375 patients with intertrochanteric fractures were imaged using computed tomography (CT) scans. Patients were grouped according to age and sex. Cortical and medullary cavity parameters (cortical thickness [CTh], cortical mean density [CM], upper-lower diameter length [ULL], and medial-lateral diameter length [MLL]) were measured at eight planes. Six proximal femoral finite element models of different sexes and ages were constructed. To verify the measurement results, Abaqus was used to implement the force load to describe the von Mises stress distribution, and the maximum von Mises stress values of each wall of the proximal femur were compared. RESULTS: The CTh values of the lower and upper walls were higher than those of the anterior and posterior walls of the femoral neck (p < 0.05). The CM values of the lower and upper walls were higher than those of the anterior and posterior walls of the subcephalic and middle femoral neck (p < 0.05). The ULL value gradually increased from the subcephalic region to the bottom (p < 0.05). The CTh and CM values of the medial and lateral walls were higher than those of the anterior and posterior walls in the femoral trochanteric region (p < 0.05). The MLL value decreased gradually from the plane 20 mm above the upper edge to that 20 mm below the vertex of the femoral lesser trochanter (p < 0.05). The von Mises stress was concentrated on the upper and lower walls of the femoral neck and on the medial and lateral walls of the femoral trochanteric region. The maximum von Mises stress values of the upper and lower walls were higher than those of the anterior and posterior walls of the femoral neck. The maximum von Mises stress values of the medial and lateral walls were higher than those of the anterior and posterior walls in the femoral trochanteric region, except for the plane 20 mm above the upper edge of the femoral lesser trochanter. CONCLUSION: The bone mass of the proximal femur presented a triangular high-modulus distribution, which bore the main stress of the proximal femur. The triangular mechanical structure provides a guideline for the surgical strategy and instrument design of the proximal femur.


Subject(s)
Femoral Fractures , Hip Fractures , Humans , Femur/surgery , Femur Neck , Lower Extremity