Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 48
Filter
2.
Bladder (San Franc) ; 11(1): e21200003, 2024.
Article in English | MEDLINE | ID: mdl-39308962

ABSTRACT

Urothelial carcinoma (UC) refers to the malignancies originating from transitional epithelium located on the upper and lower urinary tract. Precise diagnosis of UC is crucial since it dictates the treatment efficacy and prognosis of UC patients. Conventional diagnostic approaches of UC mainly fall into four types, including liquid biopsy, imaging examination, endoscopic examination, and histopathological assessment, among others, each of them has contributed to a more accurate diagnosis of the condition. Therapeutically, UC is primarily managed through surgical intervention. In recent years, minimally invasive surgery (MIS) has been incrementally used and is showing superiority in terms of lowered perioperative morbidity and quicker recovery with similar oncological outcomes achieved. For advanced UC (aUC), medical therapy is dominant. While platinum-based chemotherapies are the standard first-line option for aUC, some novel treatment alternatives have recently been introduced, such as immune checkpoint inhibitors (ICIs), targeted therapies, and antibody-drug conjugates (ADCs). ADCs, a group of sophisticated biopharmaceutical agents consisting of monoclonal antibodies, cytotoxic payload, and linker, have been increasingly drawing the attention of clinicians. In this review, we synthesize the recent developments in the precise diagnosis of UC and provide an overview of the treatment options available, including MIS for UC and emerging medications, especially ADCs of aUC.

4.
Nat Commun ; 15(1): 6215, 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39043664

ABSTRACT

Integrating genomics and histology for cancer prognosis demonstrates promise. Here, we develop a multi-classifier system integrating a lncRNA-based classifier, a deep learning whole-slide-image-based classifier, and a clinicopathological classifier to accurately predict post-surgery localized (stage I-III) papillary renal cell carcinoma (pRCC) recurrence. The multi-classifier system demonstrates significantly higher predictive accuracy for recurrence-free survival (RFS) compared to the three single classifiers alone in the training set and in both validation sets (C-index 0.831-0.858 vs. 0.642-0.777, p < 0.05). The RFS in our multi-classifier-defined high-risk stage I/II and grade 1/2 groups is significantly worse than in the low-risk stage III and grade 3/4 groups (p < 0.05). Our multi-classifier system is a practical and reliable predictor for recurrence of localized pRCC after surgery that can be used with the current staging system to more accurately predict disease course and inform strategies for individualized adjuvant therapy.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Neoplasm Recurrence, Local , Humans , Carcinoma, Renal Cell/genetics , Carcinoma, Renal Cell/pathology , Kidney Neoplasms/genetics , Kidney Neoplasms/pathology , Kidney Neoplasms/surgery , Male , Female , Neoplasm Recurrence, Local/genetics , Middle Aged , Aged , Prognosis , Genomics/methods , Adult , Neoplasm Staging , Deep Learning , Disease-Free Survival
5.
J Biol Chem ; 300(6): 107317, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38677514

ABSTRACT

It has become increasingly evident that the structures RNAs adopt are conformationally dynamic; the various structured states that RNAs sample govern their interactions with other nucleic acids, proteins, and ligands to regulate a myriad of biological processes. Although several biophysical approaches have been developed and used to study the dynamic landscape of structured RNAs, technical limitations have limited their application to all classes of RNA due to variable size and flexibility. Recent advances combining chemical probing experiments with next-generation- and direct sequencing have emerged as an alternative approach to exploring the conformational dynamics of RNA. In this review, we provide a methodological overview of the sequencing-based techniques used to study RNA conformational dynamics. We discuss how different techniques have enabled us to better understand the propensity of RNAs from a variety of different classes to sample multiple conformational states. Finally, we present examples of the ways these techniques have reshaped how we think about RNA structure.


Subject(s)
High-Throughput Nucleotide Sequencing , Nucleic Acid Conformation , RNA , RNA/chemistry , RNA/metabolism , High-Throughput Nucleotide Sequencing/methods , Nanopores , Humans , Sequence Analysis, RNA/methods
7.
Ther Adv Urol ; 15: 17562872231217842, 2023.
Article in English | MEDLINE | ID: mdl-38152349

ABSTRACT

Background: Pelvic lipomatosis (PL) is a rare condition that is characterized by excessive growth of fat in the pelvic cavity. Studies have yet to systematically review surgical treatments for PL. Objectives: To provide a reference for selecting reasonable surgical treatments for PL patients according to previous literature on the surgical treatment of PL. Design and methods: We conducted this systematic review in accordance with the Preferred Reporting Items for a Systematic Review and Meta-Analysis (PRISMA) of Individual Participant Data guidelines. Literature on PL published from 1968 to 2022 was retrieved from the PubMed and EMBASE databases. Data were collected and analyzed independently by two independent investigators. Results: A total of 42 studies, involving 231 patients with PL, were included in the analysis. The surgical treatments included transurethral resection (TUR) (48.5%), ureteral stent placement (11.7%), percutaneous nephrostomy (1.3%), ureterocutaneostomy (1.3%), ureteral reimplantation (10.4%), ileal conduit (13%), and allograft kidney transplantation (0.4%). After excluding patients with unclear prognoses, 42.9% of patients showed improvement in lower urinary tract symptoms (LUTS) after TUR. Ureteral stent placement provided relief of hydronephrosis in 62.5% of PL patients. Percutaneous nephrostomy resulted in stable renal function in 33.3% of PL patients, while ureterocutaneostomy led to remission of postoperative hydronephrosis in 33.3% of PL patients. After ureteral reimplantation, 70.8% of patients experienced relief of hydronephrosis or had stable renal function. Ileal conduit led to remission of hydronephrosis, alleviation of symptoms, or maintenance of stable renal function in 83.3% of PL patients. One patient with PL had stable renal function after allograft renal transplantation. Conclusion: The surgical treatments for PL include TUR, ureteral stent placement, urinary diversion, and allograft renal transplantation. However, the choice of surgical method should be determined after comprehensive consideration of the patient's condition.


Surgical treatment of pelvic lipomatosis: a systematic review of 231 cases Pelvic lipomatosis (PL) is a rare condition that is characterized by excessive growth of fat in the pelvic cavity. Studies have yet to systematically review surgical treatments for PL. To provide a reference for selecting reasonable surgical treatments for PL patients according to previous literature on the surgical treatment of PL, we conducted this systematic review in accordance with the Preferred Reporting Items for a Systematic Review and Meta-Analysis of Individual Participant Data (PRISMA) guidelines. A total of 42 studies, involving 231 patients with PL, were included in the final analysis. Among 231 patients with PL, the surgical treatments included transurethral resection (TUR) (48.5%), ureteral stent placement (11.7%), percutaneous nephrostomy (1.3%), ureterocutaneostomy (1.3%), ureteral reimplantation (10.4%), ileal conduit (13%), and allograft kidney transplantation (0.4%). After excluding patients with unclear prognoses, 42.9% of patients showed improvement in lower urinary tract symptoms (LUTS) after TUR. Ureteral stent placement provided relief of hydronephrosis in 62.5% of PL patients. Percutaneous nephrostomy resulted in stable renal function in 33.3% of PL patients, while ureterocutaneostomy led to remission of postoperative hydronephrosis in 33.3% of PL patients. After ureteral reimplantation, 70.8% of patients experienced relief of hydronephrosis or had stable renal function. Ileal conduit led to remission of hydronephrosis, alleviation of symptoms, or maintenance of stable renal function in 83.3% of PL patients. One patient with PL had stable renal function after allograft renal transplantation. The surgical treatments for PL include TUR, ureteral stent placement, urinary diversion, and allograft renal transplantation. However, the choice of surgical method should be determined after comprehensive consideration of the patient's condition.

8.
Chin Med J (Engl) ; 136(24): 2960-2966, 2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38013503

ABSTRACT

BACKGROUND: The KangDuo-Surgical Robot-01 (KD-SR-01) system is a new surgical robot recently developed in China. The aim of this study was to present our single-center experience and mid-term outcomes of urological procedures using the KD-SR-01 system. METHODS: From August 2020 to April 2023, consecutive urologic procedures were performed at Peking University First Hospital using the KD-SR-01 system. The clinical features, perioperative data, and follow-up outcomes were prospectively collected and analyzed. RESULTS: A total of 110 consecutive patients were recruited. Among these patients, 28 underwent partial nephrectomy (PN), 41 underwent urinary tract reconstruction (26 underwent pyeloplasty, 3 underwent ureteral reconstruction and 12 underwent ureterovesical reimplantation [UR]), and 41 underwent radical prostatectomy (RP). The median operative time for PN was 112.5 min, 157.0 min for pyeloplasty, 151.0 min for ureteral reconstruction, 142.5 min for UR, and 138.0 min for RP. The median intraoperative blood loss was 10 mL for PN, 10 mL for pyeloplasty, 30 mL for ureteral reconstruction, 20 mL for UR, and 50 mL for RP. All procedures were successfully completed without conversion, and there were no major complications in any patient. The median warm ischemia time of PN was 17.3 min, and positive surgical margin was not noted in any patient. The overall positive surgical margin rate of RP was 39% (16/41), and no biochemical recurrence was observed in any RP patient during the median follow-up of 11.0 months. The surgical success rates of pyeloplasty and UR were 96% (25/26) and 92% (11/12) during the median follow-up of 29.5 months and 11.5 months, respectively. CONCLUSION: The KD-SR-01 system appears feasible, safe, and effective for most urological procedures, based on our single-center experience.


Subject(s)
Laparoscopy , Robotic Surgical Procedures , Robotics , Ureter , Male , Humans , Robotic Surgical Procedures/methods , Treatment Outcome , Retrospective Studies , Ureter/surgery , Urologic Surgical Procedures/methods , Laparoscopy/methods
9.
Asian J Urol ; 10(4): 482-487, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38024439

ABSTRACT

Objective: To assess the feasibility of internal suspension technique in retroperitoneal robot-assisted laparoscopic partial nephrectomy (rRAPN) with a new robotic platform called KangDuo Surgical Robot-01 (KD-SR-01) system (Suzhou KangDuo Robot Co., Ltd., Suzhou, China) and discuss its surgical technique. Methods: A 44-year-old male patient was admitted with a 2.5 cm tumor on dorsolateral upper pole of the left kidney. The R.E.N.A.L. nephrometry score of this patient was 4x. This patient underwent rRAPN with KD-SR-01. The perinephric fat between the tumor and Gerota's fascia was preserved, which was used for internal suspension traction during tumor resection. Postoperative follow-up data were collected. Results: The surgery was successfully carried out with a duration of 127 min, in which the docking time was 6 min 25 s and console time was 60 min. The warm ischemia time was 19 min 53 s, and the estimated blood loss was 0 mL. The pathological histology showed a pathological tumor stage 1a clear cell renal cell carcinoma, with a negative surgical margin. The World Health Organization/International Society of Urological Pathology (WHO/ISUP) grade of this patient was Grade 2. No recurrence was observed during the 6-month follow-up. Conclusion: Internal suspension in rRAPN is feasible and effective with use of the new robotic system KD-SR-01.

10.
Lancet Digit Health ; 5(8): e515-e524, 2023 08.
Article in English | MEDLINE | ID: mdl-37393162

ABSTRACT

BACKGROUND: Improved markers for predicting recurrence are needed to stratify patients with localised (stage I-III) renal cell carcinoma after surgery for selection of adjuvant therapy. We developed a novel assay integrating three modalities-clinical, genomic, and histopathological-to improve the predictive accuracy for localised renal cell carcinoma recurrence. METHODS: In this retrospective analysis and validation study, we developed a histopathological whole-slide image (WSI)-based score using deep learning allied to digital scanning of conventional haematoxylin and eosin-stained tumour tissue sections, to predict tumour recurrence in a development dataset of 651 patients with distinctly good or poor disease outcome. The six single nucleotide polymorphism-based score, which was detected in paraffin-embedded tumour tissue samples, and the Leibovich score, which was established using clinicopathological risk factors, were combined with the WSI-based score to construct a multimodal recurrence score in the training dataset of 1125 patients. The multimodal recurrence score was validated in 1625 patients from the independent validation dataset and 418 patients from The Cancer Genome Atlas set. The primary outcome measured was the recurrence-free interval (RFI). FINDINGS: The multimodal recurrence score had significantly higher predictive accuracy than the three single-modal scores and clinicopathological risk factors, and it precisely predicted the RFI of patients in the training and two validation datasets (areas under the curve at 5 years: 0·825-0·876 vs 0·608-0·793; p<0·05). The RFI of patients with low stage or grade is usually better than that of patients with high stage or grade; however, the RFI in the multimodal recurrence score-defined high-risk stage I and II group was shorter than in the low-risk stage III group (hazard ratio [HR] 4·57, 95% CI 2·49-8·40; p<0·0001), and the RFI of the high-risk grade 1 and 2 group was shorter than in the low-risk grade 3 and 4 group (HR 4·58, 3·19-6·59; p<0·0001). INTERPRETATION: Our multimodal recurrence score is a practical and reliable predictor that can add value to the current staging system for predicting localised renal cell carcinoma recurrence after surgery, and this combined approach more precisely informs treatment decisions about adjuvant therapy. FUNDING: National Natural Science Foundation of China, and National Key Research and Development Program of China.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Humans , Carcinoma, Renal Cell/diagnosis , Carcinoma, Renal Cell/genetics , Carcinoma, Renal Cell/pathology , Prognosis , Retrospective Studies , Biomarkers, Tumor , Neoplasm Recurrence, Local/diagnosis , Neoplasm Recurrence, Local/genetics , Neoplasm Recurrence, Local/pathology , Kidney Neoplasms/diagnosis , Kidney Neoplasms/genetics , Kidney Neoplasms/pathology
12.
Int. braz. j. urol ; 49(3): 388-390, may-June 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1440250

ABSTRACT

ABSTRACT Purpose Horseshoe kidney (HSK) is the most common renal fusion anomaly, occurring in 0.25% of the population (1). It presents technical obstacles to pyeloplasty for ureteropelvic junction obstruction (UPJO) despite robotic assistance (2, 3). KangDuo-Surgical-Robot-01 (KD-SR-01), an emerging robotic platform in China, has yielded satisfactory outcomes in pyeloplasty (4, 5). We first describe our modified technique of robotic bilateral pyeloplasty for UPJO in HSK using KD-SR-01 system in the Lithotomy Trendelenburg position. Materials and Methods A 36-year-old man with HSK and bilateral UPJO suffered right flank pain due to renal calculi (Figure-1). Repeated double-J stent insertion and ureteroscopy lithotripsy did not relieve his symptoms. A robot-assisted modified bilateral dismembered V-shaped flap pyeloplasty was performed using KD-SR-01 system in the Lithotomy Trendelenburg position. Results Total operative time was 298 minutes with 50 ml estimated blood loss. There was no conversion to laparoscopic or open surgery. A follow-up of 14 months showed relieving symptoms and stable renal function. Cine magnetic resonance urography and computed tomography urography revealed improved hydronephrosis and good drainage. No intraoperative or postoperative complications occurred. Conclusions It is technically feasible to perform a KD-SR-01-assisted modified bilateral dismembered V-shaped flap pyeloplasty in the Lithotomy Trendelenburg position for HSK. This procedure achieves managing UPJO on both sides without redocking the system and provides a wider operative field. In addition, it may be associated with better ergonomics, better cosmetic outcomes, and less possibility of postoperative bowel adhesion. However, further investigation is still warranted to confirm its safety, efficacy, and advantages over traditional procedures.

13.
J Endourol ; 37(5): 568-574, 2023 05.
Article in English | MEDLINE | ID: mdl-36924278

ABSTRACT

Objective: To compare the efficacy and safety of robot-assisted laparoscopic radical prostatectomy (RARP) performed using the KangDuo surgical robot system to the da Vinci Si robotic system in clinically localized prostate cancer (KD-RARP vs DV-RARP). Methods: A total of 16 patients underwent extraperitoneal KD-RARP performed by a single experienced surgeon using the KangDuo surgical robot system between May 2021 and August 2021. The data were prospectively collected. The most recent 16 cases of extraperitoneal DV-RARP performed in 2021 by the same surgeon were selected from a prospectively maintained database for comparison to prevent operator variability. Preoperative, perioperative, and postoperative data were collected and compared between the two groups. Results: No significant difference was noted between the two groups in terms of basic clinical characteristics. All operations were performed successfully without open or traditional laparoscopic conversion. KD-RARP had a significantly longer operation time compared with DV-RARP (127 [107-159] vs 70.5 [54-90] minutes, p < 0.001). No significant differences between the two groups were observed in neurovascular bundle sparing, estimated blood loss, postoperative hospital stay duration, complications, positive surgical margins, biochemical recurrence, and continence recovery 3 months after catheter removal. Conclusions: RARP using the KangDuo surgical robot system achieved similar short-term oncological and functional outcomes with a disadvantage in operation time compared with the da Vinci Si robotic system. A multicenter randomized clinical trial with a larger sample size is needed for more experience.


Subject(s)
Laparoscopy , Prostatic Neoplasms , Robotic Surgical Procedures , Robotics , Male , Humans , Prostate/surgery , Prostatectomy , Prostatic Neoplasms/surgery , Treatment Outcome
14.
Int Braz J Urol ; 49(3): 388-390, 2023.
Article in English | MEDLINE | ID: mdl-36515621

ABSTRACT

PURPOSE: Horseshoe kidney (HSK) is the most common renal fusion anomaly, occurring in 0.25% of the population (1). It presents technical obstacles to pyeloplasty for ureteropelvic junction obstruction (UPJO) despite robotic assistance (2, 3). KangDuo-Surgical-Robot-01 (KD-SR-01), an emerging robotic platform in China, has yielded satisfactory outcomes in pyeloplasty (4, 5). We first describe our modified technique of robotic bilateral pyeloplasty for UPJO in HSK using KD-SR-01 system in the Lithotomy Trendelenburg position. MATERIALS AND METHODS: A 36-year-old man with HSK and bilateral UPJO suffered right flank pain due to renal calculi (Figure-1). Repeated double-J stent insertion and ureteroscopy lithotripsy did not relieve his symptoms. A robot-assisted modified bilateral dismembered V-shaped flap pyeloplasty was performed using KD-SR-01 system in the Lithotomy Trendelenburg position. RESULTS: Total operative time was 298 minutes with 50 ml estimated blood loss. There was no conversion to laparoscopic or open surgery. A follow-up of 14 months showed relieving symptoms and stable renal function. Cine magnetic resonance urography and computed tomography urography revealed improved hydronephrosis and good drainage. No intraoperative or postoperative complications occurred. CONCLUSIONS: It is technically feasible to perform a KD-SR-01-assisted modified bilateral dismembered V-shaped flap pyeloplasty in the Lithotomy Trendelenburg position for HSK. This procedure achieves managing UPJO on both sides without redocking the system and provides a wider operative field. In addition, it may be associated with better ergonomics, better cosmetic outcomes, and less possibility of postoperative bowel adhesion. However, further investigation is still warranted to confirm its safety, efficacy, and advantages over traditional procedures.


Subject(s)
Fused Kidney , Laparoscopy , Robotics , Ureteral Obstruction , Male , Humans , Adult , Fused Kidney/complications , Fused Kidney/surgery , Kidney Pelvis/surgery , Kidney Pelvis/pathology , Urologic Surgical Procedures/methods , Ureteral Obstruction/surgery , Ureteral Obstruction/pathology , Kidney/surgery , Kidney/physiology , Laparoscopy/methods , Retrospective Studies , Treatment Outcome
15.
Int Urol Nephrol ; 55(3): 597-604, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36327006

ABSTRACT

PURPOSE: Ureteroplasty with a lingual mucosa graft (LMG) for complex ureteral stricture was reported promising. We aimed to compare outcomes of robotic versus laparoscopic ureteroplasty using a LMG (RU-LMG vs. LU-LMG, respectively). METHODS: From October 2018 to January 2021, 32 ureteroplasties using LMGs were performed by one experienced surgeon, including 16 robotic and laparoscopic procedures each. Patient demographics and peri-operative, post-operative, and follow-up data were prospectively collected and compared. RESULTS: The robotic group had a higher rate of previous reconstruction than the laparoscopic group (62.50% vs. 18.75%; p = 0.012). The stricture length was significantly longer in the robotic group (4.8 ± 1.2 cm) than the laparoscopic group (3.7 ± 1.2 cm; p = 0.013). All procedures were completed successfully without open conversion. The operative time was shorter in the robotic group (192 ± 54 min) than the laparoscopic group (254 ± 46 min; p = 0.001). The robotic group had a shorter length of post-operative stay (6.1 ± 2.4 d vs. 8.9 ± 4.3 d; p = 0.033) but a higher hospital cost (76,801 ± 17,974 vs. 42,214 ± 15,757 RMB; p < 0.001) than the laparoscopic group. The mean follow-up time was 21 ± 7 months for the robotic group and 29 ± 9 months for the laparoscopic group respectively (p = 0.014). No difference was detected in the success rate (93.75% and 100%, respectively; p = 0.309) and complication rate (18.75% and 31.25%, respectively; p = 0.414) between the robotic and laparoscopic groups. CONCLUSION: Both RU-LMG and LU-LMG are feasible, effective, and safe for repair of complex ureteral strictures. RU-LMG had a shorter operative time and a shorter length of post-operative stay but a higher hospital cost.


Subject(s)
Laparoscopy , Robotic Surgical Procedures , Ureter , Ureteral Obstruction , Humans , Constriction, Pathologic/surgery , Robotic Surgical Procedures/methods , Ureter/surgery , Ureteral Obstruction/surgery , Laparoscopy/methods , Mouth Mucosa/transplantation , Retrospective Studies , Treatment Outcome
16.
Eur Urol Focus ; 9(1): 133-140, 2023 01.
Article in English | MEDLINE | ID: mdl-36446724

ABSTRACT

BACKGROUND: The KangDuo surgical robot (KD-SR) was recently developed in China. OBJECTIVE: To compare the safety and efficacy of the KD-SR versus the da Vinci Si Surgical System (DV-SS-Si) for robot-assisted partial nephrectomy (RAPN). DESIGN, SETTING, AND PARTICIPANTS: A double-center prospective randomized controlled noninferiority trial of patients aged 18-75 yr with a suspicion of T1a N0M0 renal cancer (RENAL nephrometry score ≤9) was conducted. INTERVENTION: RAPN with the KD-SR versus the DV-SS-Si. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The primary endpoint was the success rate of operation. The operation was successful if (1) there was no open or laparoscopic conversion, (2) the warm ischemia time was <30 min for RENAL nephrometry scores of 4-6 or 40 min for RENAL nephrometry scores of 7-9, and (3) the pathological margin was negative. The secondary endpoint was the estimated glomerular filtration rate (eGFR). A threshold of 10% was set to demonstrate noninferiority. RESULTS AND LIMITATIONS: From September 2020 to March 2021, 100 participants were enrolled, of whom 99 (49 in the KD-SR group and 50 in the DV-SS-Si group) were finally included in the full analysis set and 98 (49 in the KD-SR group and -49 in the DV-SS-Si group) in the per-protocol set. Baseline demographic and clinical characteristics were similar between the two groups. All surgeries were completed successfully. The eGFR at postoperative weeks 4-12 and adverse events were similar between the two groups. The docking time and suture time per stitch were longer in the KD-SR group. The main limitation was that a negative margin was considered as the primary outcome rather than survival. CONCLUSIONS: The KD-SR achieved noninferior outcomes as compared with the DV-SS-Si regarding safety and efficacy for T1a tumors. PATIENT SUMMARY: The first trial comparing the KangDuo surgical robot (KD-SR) versus the da Vinci Si Surgical System for robot-assisted partial nephrectomy showed that the KD-SR is a viable option for minimally invasive treatment of T1a renal tumors.


Subject(s)
Kidney Neoplasms , Laparoscopy , Robotics , Humans , Prospective Studies , Treatment Outcome , Nephrectomy/methods , Kidney Neoplasms/surgery , Kidney Neoplasms/pathology , Laparoscopy/methods
17.
Luminescence ; 38(2): 109-115, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36544245

ABSTRACT

Reactive oxygen species (ROS) are usually produced in rice under aerobic environmental conditions, resulting in peroxidative changes in polyunsaturated fatty acids, and affecting the deterioration of rice during storage. In addition, as an important enzyme that participates in removing ROS, peroxidase is also present in rice, and takes part in protecting rice from attack by ROS. Moreover, loss of peroxidase activity may give rise to rice deterioration during storage. Therefore, measuring peroxidase activity makes it possible to ascertain the freshness of rice. In addition, peroxidase can also catalyze the luminol-hydrogen peroxide system. Based on this, in this work we established a new chemiluminescence (CL) method that was used to detect the freshness of stored rice. Under optimal experimental conditions, we showed that the freshness of rice can be measured using this CL method. This study is the first to detect the freshness of rice using a CL method, opening up a novel direction for the application of CL.


Subject(s)
Oryza , Reactive Oxygen Species , Luminescence , Luminescent Measurements/methods , Luminol , Peroxidase , Hydrogen Peroxide
18.
Medicina (Kaunas) ; 58(12)2022 Nov 30.
Article in English | MEDLINE | ID: mdl-36556969

ABSTRACT

Background and Objectives: To clinically validate the computed tomography (CT)-based three-dimension (3D) model for treatment planning and intraoperative navigation of ureteropelvic junction obstruction (UPJO) complicated with renal calculi. Materials and Methods: We retrospectively collected the data of 26 patients with UPJO and renal calculi who were surgically treated in our institution from January 2019 to December 2021. Before surgery, 3D models based on preoperative CT scans were constructed in all patients. Additionally, the patients were divided into three groups according to the results of 3D models, distinguished by different treatment of renal calculi, that is, left untreated (1), pyelolithotomy (2), and endoscopic lithotomy (3). The quantitative analysis of renal calculi parameters, and perioperative and follow-up data were compared. Results: The mean number of involved renal calyces (p = 0.041), and the mean maximum cross-sectional area (p = 0.036) of renal stones were statistically different among the three groups. There were no significant differences among the three groups in the mean operative time, mean estimated blood loss, mean pararenal draining time, and mean hospital stay. The intraoperative stone clearance rates were 100% (11/11) and 77.8% (7/9) in group 2 and group 3, respectively. The trends of increased estimated glomerular filtration rate and decreased creatinine on the average levels after surgery were observed, although these changes were not statistically significant. At a mean follow-up of 19.4 ± 6.4 months, the overall surgical success rate of the UPJO was 96.2% (25/26), and the overall success rate of renal calculi removal was 80.8% (21/26). Renal stones in 66.7% (4/6) of patients in group 1 spontaneously passed out. Conclusions: Preoperative 3D CT models have exact clinical value in the surgical planning and intraoperative navigation of UPJO patients complicated with renal calculi.


Subject(s)
Kidney Calculi , Laparoscopy , Ureteral Obstruction , Humans , Retrospective Studies , Laparoscopy/methods , Kidney Calculi/complications , Kidney Calculi/diagnostic imaging , Kidney Calculi/surgery , Ureteral Obstruction/complications , Ureteral Obstruction/diagnostic imaging , Ureteral Obstruction/surgery , Tomography , Treatment Outcome
19.
BMC Surg ; 22(1): 435, 2022 Dec 21.
Article in English | MEDLINE | ID: mdl-36544120

ABSTRACT

BACKGROUND: Complete intracorporal robotic ileal ureteric replacement is challenging. We aimed to present the surgical technique of robotic ileal ureter replacement with extracorporeal ileal segment preparation for long ureteral strictures. METHODS: From March 2019 to March 2021, 18 patients underwent robotic ileal ureter replacement with extracorporeal ileal segment preparation by one experienced surgeon. The demographic, perioperative, and follow-up data were recorded. Success was defined as the resolution of the presenting symptom, a stable estimated glomerular filtration rate and unobstructive drainage on imaging examination. RESULTS: All 18 surgeries were successfully completed without conversion. The median length of the intestinal tube used was 20 (12-30) cm. The median operative time was 248 (170-450) min, the median estimated blood loss was 50 (10-200) ml, and the median postoperative hospital stay was 7 (5-27) days. At a median follow-up of 16 (13-28) months, all patients were symptom-free. No or mild hydronephrosis was confirmed in 17 patients; 1 patient had moderate hydronephrosis without peristalsis of the ileal ureter. The renal function was stable in all patients. The overall success rate was 100%. Postoperative complications, including 4 cases of urinary infections (Grade I), 1 case of an incision hernia (Grade I), 4 cases of kidney stone formation (Grade I), 6 cases of metabolic acidosis (Grade I), 4 cases of incomplete ileus (Grade II), and 1 case of an incision infection (Grade IIIb). CONCLUSIONS: Robot-assisted laparoscopic ileal ureter replacement with extracorporeal ileal segment preparation is safe, feasible, and effective for the treatment of long ureteral strictures, especially in high-volume tertiary referral centers with extensive robotic surgery experience capable of managing severe peri-operative complications.


Subject(s)
Hydronephrosis , Laparoscopy , Robotic Surgical Procedures , Robotics , Ureter , Ureteral Obstruction , Humans , Ureter/surgery , Constriction, Pathologic/surgery , Ureteral Obstruction/surgery , Hydronephrosis/surgery , Laparoscopy/methods , Retrospective Studies
20.
Molecules ; 27(16)2022 Aug 18.
Article in English | MEDLINE | ID: mdl-36014594

ABSTRACT

The authors would like to correct an error in the original publication [...].

SELECTION OF CITATIONS
SEARCH DETAIL