Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
Med Phys ; 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39225581

ABSTRACT

BACKGROUND: The skin is the largest organ of the human body and serves distinct functions in protecting the body. The viscoelastic properties of the skin play a key role in supporting the skin-healing process, also it may be changed due to some skin diseases. PROPOSE: In this study, high-frequency ultrasound (HFUS) elastography based on a Lamb wave model was used to noninvasively assess the viscoelastic anisotropy of human skin. METHOD: Elastic waves were generated through an external vibrator, and the wave propagation velocity was measured through 40 MHz ultrafast HFUS imaging. Through the use of a thin-layer gelatin phantom, HFUS elastography was verified to produce highly accurate estimates of elasticity and viscosity. In a human study involving five volunteers, viscoelastic anisotropy was assessed by rotating an ultrasound transducer 360°. RESULTS: An oval-shaped pattern in the elasticity of human forearm skin was identified, indicating the high elastic anisotropy of skin; the average elastic moduli were 24.90 ± 6.63 and 13.64 ± 2.67 kPa along and across the collagen fiber orientation, respectively. The average viscosity of all the recruited volunteers was 3.23 ± 0.93 Pa·s. CONCLUSIONS: Although the examined skin exhibited elastic anisotropy, no evident viscosity anisotropy was observed.

2.
Article in English | MEDLINE | ID: mdl-38163298

ABSTRACT

The shoulder is the most mobile joint in the human body, thus requiring intricate coordination of adjacent muscles. Patients suffered from rotator cuff muscle injuries have several typical symptoms including shoulder pain and difficulty raising the arm, thus reducing work efficiency and compromising the quality of life. Ultrasound has been used widely for shoulder soft tissue imaging as well as ultrasound elastography was introduced in shoulder examination for the dilemma of treating degenerative rotator cuff tears. However, most of the ultrasound examination was performed under a static condition. Providing dynamic information from shoulder muscle is important in clinical applications because the pains sometimes come from various positions of the shoulder during moving. In this study, a customized wearable T-shaped ultrasound transducer (128 + 128 elements) was proposed for shoulder dual-direction shear wave elastography (DDSWE), which provides the SWE for both longitudinal (SW along the muscle fiber) and transverse (SW cross the muscle fiber) directions dynamically. An optical tracking system was synchronized with an ultrasound imaging system to capture shoulder movements in 3-D space with their corresponding ultrasound images. The performance of DDSWE and the accuracy of optical tracking were verified by phantom experiments. Human studies were carried out by volunteers as they are moving their arms. The experimental results show that the bias and precision for the proposed DDSWE in elastic phantom were about 6% and 1.2% for both directions, respectively. A high accuracy of optical tracking was observed using a 3-D motor stage experimental setup. Human experiments show that the shear wave velocities (SWVs) were increased with the angles of shoulder abduction, and the average transverse and longitudinal SWVs were increased from 2.24 to 3.35 m/s and 2.95 to 5.95 m/s with abduction angle from 0° to 60°, respectively, which they are anisotropic-dependent. All the experimental results indicate that the proposed wearable ultrasound DDSWE can quantify the mechanical properties of shoulder muscles dynamically, thereby helping surgeons and physical therapists determine whether the intensity of rehabilitation shoulder be tuned down or escalated in the future.


Subject(s)
Elasticity Imaging Techniques , Equipment Design , Phantoms, Imaging , Shoulder , Wearable Electronic Devices , Elasticity Imaging Techniques/methods , Elasticity Imaging Techniques/instrumentation , Humans , Shoulder/diagnostic imaging , Shoulder/physiology , Adult , Male , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Rotator Cuff/diagnostic imaging , Rotator Cuff/physiology , Transducers
3.
Adv Sci (Weinh) ; 10(35): e2302345, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37964413

ABSTRACT

Although the relationships of cerebrovascular hemodynamic dysfunction with neurodegenerative diseases remain unclear, many studies have indicated that poor cerebral perfusion accelerates the progression of neurodegenerative diseases, such as Alzheimer's disease (AD). Small animal models are widely used in AD research. However, providing an imaging modality with a high spatiotemporal resolution and sufficiently large field of view to assess cerebrovascular hemodynamics in vivo remains a challenge. The present study proposes a novel technique for high-spatiotemporal-resolution vector micro-Doppler imaging (HVµDI) based on contrast-free ultrafast high frequency ultrasound imaging to visualize the cerebrovascular hemodynamics of the mouse, with a data acquisition time of 0.4 s, a minimal detectable vessel size of 38 µm, and a temporal resolution of 500 Hz. In vivo experiments are conducted on wild-type and AD mice. Cerebrovascular hemodynamics are quantified using the cerebral vascular density, diameter, velocity, tortuosity, cortical flow pulsatility, and instant flow direction variations. Results reveal that AD significantly change the cerebrovascular hemodynamics. HVµDI offers new opportunities for in vivo analysis of cerebrovascular hemodynamics in neurodegenerative pathologies in preclinical animal research.


Subject(s)
Alzheimer Disease , Mice , Animals , Alzheimer Disease/diagnostic imaging , Hemodynamics , Disease Models, Animal , Ultrasonography
4.
Article in English | MEDLINE | ID: mdl-37669211

ABSTRACT

High-resolution ultrasound shear wave elastography has been used to determine the mechanical properties of hand tendons. However, because of fiber orientation, tendons have anisotropic properties; this results in differences in shear wave velocity (SWV) between ultrasound scanning cross sections. Rotating transducers can be used to achieve full-angle scanning. However, this technique is inconvenient to implement in clinical settings. Therefore, in this study, high-frequency ultrasound (HFUS) dual-direction shear wave imaging (DDSWI) based on two external vibrators was used to create both transverse and longitudinal shear waves in the human flexor carpi radialis tendon. SWV maps from two directions were obtained using 40-MHz ultrafast imaging at the same scanning cross section. The anisotropic map was calculated pixel by pixel, and 3-D information was obtained using mechanical scanning. A standard phantom experiment was then conducted to verify the performance of the proposed HFUS DDSWI technique. Human studies were also conducted where volunteers assumed three hand postures: relaxed (Rel), full fist (FF), and tabletop (TT). The experimental results indicated that both the transverse and longitudinal SWVs increased due to tendon flexion. The transverse SWV surpassed the longitudinal SWV in all cases. The average anisotropic ratios for the Rel, FF, and TT hand postures were 1.78, 2.01, and 2.21, respectively. Both the transverse and the longitudinal SWVs were higher at the central region of the tendon than at the surrounding region. In conclusion, the proposed HFUS DDSWI technique is a high-resolution imaging technique capable of characterizing the anisotropic properties of tendons in clinical applications.


Subject(s)
Elasticity Imaging Techniques , Tendons , Humans , Anisotropy , Tendons/diagnostic imaging , Ultrasonography/methods , Elasticity Imaging Techniques/methods , Phantoms, Imaging
5.
Biosensors (Basel) ; 13(1)2023 Jan 13.
Article in English | MEDLINE | ID: mdl-36671969

ABSTRACT

Robotic prostheses and powered exoskeletons are novel assistive robotic devices for modern medicine. Muscle activity sensing plays an important role in controlling assistive robotics devices. Most devices measure the surface electromyography (sEMG) signal for myoelectric control. However, sEMG is an integrated signal from muscle activities. It is difficult to sense muscle movements in specific small regions, particularly at different depths. Alternatively, traditional ultrasound imaging has recently been proposed to monitor muscle activity due to its ability to directly visualize superficial and at-depth muscles. Despite their advantages, traditional ultrasound probes lack wearability. In this paper, a wearable ultrasound (US) transducer, based on lead zirconate titanate (PZT) and a polyimide substrate, was developed for a muscle activity sensing demonstration. The fabricated PZT-5A elements were arranged into a 4 × 4 array and then packaged in polydimethylsiloxane (PDMS). In vitro porcine tissue experiments were carried out by generating the muscle activities artificially, and the muscle movements were detected by the proposed wearable US transducer via muscle movement imaging. Experimental results showed that all 16 elements had very similar acoustic behaviors: the averaged central frequency, -6 dB bandwidth, and electrical impedance in water were 10.59 MHz, 37.69%, and 78.41 Ω, respectively. The in vitro study successfully demonstrated the capability of monitoring local muscle activity using the prototyped wearable transducer. The findings indicate that ultrasonic sensing may be an alternative to standardize myoelectric control for assistive robotics applications.


Subject(s)
Robotics , Wearable Electronic Devices , Animals , Swine , Ultrasonography , Muscles , Transducers
6.
IEEE Trans Biomed Eng ; 69(9): 2745-2754, 2022 09.
Article in English | MEDLINE | ID: mdl-35192460

ABSTRACT

OBJECTIVE: Ultrasound (US) shear wave elasticity imaging (SWEI) is a mature technique for diagnosing the elasticity of isotropic tissues. However, the elasticity of anisotropic tissues, such as muscle and tendon, cannot be diagnosed correctly using SWEI because the shear wave velocity (SWV) varies with tissue fiber orientations. Recently, SWEI has been studied for measuring the anisotropic properties of muscles by rotating the transducer; however, this is difficult for clinical practice. METHODS: In this study, a novel dual-direction shear wave imaging (DDSWI) technique was proposed for visualizing the mechanical anisotropy of muscles without rotation. Longitudinal and transverse shear waves were created by a specially designed external vibrator and supersonic pushing beam, respectively; the SWVs were then tracked using ultrafast US imaging. Subsequently, the SWV maps of two directions were obtained at the same scanning cross section, and the mechanical anisotropy was represented as the ratio between them at each pixel. RESULTS: The performance of DDSWI was verified using a standard phantom, and human experiments were performed on the gastrocnemius and biceps brachii. Experimental results of phantom revealed DDSWI exhibited a high precision of <0.81% and a low bias of <3.88% in SWV measurements. The distribution of anisotropic properties in muscle was visualized with the anisotropic ratios of 1.54 and 2.27 for the gastrocnemius and biceps brachii, respectively. CONCLUSION: The results highlight the potential of this novel anisotropic imaging in clinical applications because the conditions of musculoskeletal fiber orientation can be easily and accurately evaluated in real time by DDSWI.


Subject(s)
Elasticity Imaging Techniques , Anisotropy , Elasticity , Elasticity Imaging Techniques/methods , Humans , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Phantoms, Imaging
SELECTION OF CITATIONS
SEARCH DETAIL