Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Publication year range
1.
Article in Chinese | MEDLINE | ID: mdl-38686480

ABSTRACT

The difficulty of cochlear implantation in patients with congenital microtia is usually increased due to the vague anatomical marks and facial nerve malformation. The common types of facial nerve malformation include facial nerve bony cover loss, aberrant position, and bifurcation malformation. Bifurcation malformation may obscure the oval window, press against stapes, and bifurcate in the vestibular window while obscuring the round window. It is important to correctly identify the facial nerve and choose a reasonable surgical approach to avoid postoperative complications. This article describes a case of profound sensorineural hearing loss due to facial nerve malformation in our institution. The patient underwent cochlear implantation through the retro-facial approach. There was no facial nerve injury or dysfunction symptoms such as facial paralysis and hemifacial spasm 2 years after the operation, and the cochlear implant works well. The score of the categories of the auditory performance(CAP) questionnaire was 7, and the score of the speech intelligibility rating(SIR) questionnaire was 4. When the round window cannot be exposed through the facial recess approach during surgery, the retro-facial approach is a feasible method. To avoid facial nerve injury, a thin-section CT of the temporal bone should be performed before the middle and inner ear surgery for patients with facial nerve malformation, and the intraoperative facial nerve monitor should be used to clarify the course of the facial nerve to avoid injury.


Subject(s)
Cochlear Implantation , Congenital Microtia , Facial Nerve , Humans , Cochlear Implantation/methods , Congenital Microtia/surgery , Facial Nerve/abnormalities , Facial Nerve/surgery , Hearing Loss, Sensorineural/surgery , Temporal Bone/abnormalities , Temporal Bone/surgery
2.
Article in English | MEDLINE | ID: mdl-38353769

ABSTRACT

OBJECTIVE: The objectives of this study are twofold: first, to visualize the structure of malformed cochleae through image reconstruction; and second, to develop a predictive model for postoperative outcomes of cochlear implantation (CI) in patients diagnosed with cochlear hypoplasia (CH) and incomplete partition (IP) malformation. METHODS: The clinical data from patients diagnosed with cochlear hypoplasia (CH) and incomplete partition (IP) malformation who underwent cochlear implantation (CI) at Beijing Tongren Hospital between January 2016 and August 2020 were collected. Radiological features were analyzed through 3D segmentation of the cochlea. Postoperative auditory speech rehabilitation outcomes were evaluated using the Categories of Auditory Performance (CAP) and the Speech Intelligibility Rating (SIR). This study aimed to investigate the relationship between cochlear parameters and postoperative outcomes. Additionally, a predictive model for postoperative outcomes was developed using the K-nearest neighbors (KNN) algorithm. RESULTS: In our study, we conducted feature selection by using patients' imaging and audiological attributes. This process involved methods such as the removal of missing values, correlation analysis, and chi-square tests. The findings indicated that two specific features, cochlear volume (V) and cochlear canal length (CDL), significantly contributed to predicting the outcomes of hearing and speech rehabilitation for patients with inner ear malformations. In terms of hearing rehabilitation, the KNN classification achieved an accuracy of 93.3%. Likewise, for speech rehabilitation, the KNN classification demonstrated an accuracy of 86.7%. CONCLUSION: The measurements obtained from the 3D reconstruction model hold significant clinical relevance. Despite the considerable variability in cochlear morphology across individuals, radiological features remain effective in predicting cochlear implantation (CI) prognosis for patients with inner ear malformations. The utilization of 3D segmentation techniques and the developed predictive model can assist surgeons in conducting preoperative cochlear structural measurements for patients with inner ear malformations. This, in turn, can offer a more informed perspective on the anticipated outcomes of cochlear implantation.

3.
Int J Pediatr Otorhinolaryngol ; 176: 111781, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38006708

ABSTRACT

BACKGROUND: With the increasing clinical focus on the safety of bilateral cochlear implantation (CI) and the potential risk of bilateral vestibular dysfunction, evaluating vestibular end-organ function in patients with vestibular malformations with accompanying abnormalities has been strongly recommended. OBJECTIVES: To identify the vestibular-evoked myogenic potential (VEMP) values among children with sensorineural hearing loss (SNHL) with vestibular malformation and assess the effectiveness of VEMP testing for inner ear malformations (IEM) diagnosis. METHODS: This study included 96 children (192 ears), including those with vestibular malformations (48 ears), large vestibular aqueduct syndrome (LVAS) (50 ears), and SNHL without IEM (94 ears; control group). All groups underwent ocular and cervical VEMP (oVEMP and cVEMP, respectively) testing. The response rates, VEMP parameters, and wave characteristics were compared. RESULTS: The cVEMP response rates were 37.5 %, 64 %, and 58.51 % and the oVEMP response rates were 42.86 %, 78.95 %, and 77.27 % in the vestibular malformation, LVAS, and control groups, respectively, and significantly differed between groups (cVEMP: X2 = 18.228, P<0.001) (oVEMP: X2 = 7.528, P = 0.023). Significant inter-group differences were observed for the cVEMP and oVEMP latency and amplitude (P < 0.05). The LVAS group's waveform exhibited a prolonged latency and increased amplitude compared with that of the other groups. CONCLUSION: Patients with SNHL were highly susceptible to otolith dysfunction, regardless of comorbid vestibular malformation presence. Measuring VEMPs is an effective and rapid evaluation technique for vestibular function and could provide a basis for vestibular rehabilitation training.


Subject(s)
Cochlear Implantation , Hearing Loss, Sensorineural , Vestibular Diseases , Vestibular Evoked Myogenic Potentials , Vestibule, Labyrinth , Child , Humans , Vestibular Evoked Myogenic Potentials/physiology , Hearing Loss, Sensorineural/diagnosis , Vestibular Diseases/complications , Vestibular Diseases/diagnosis , Syndrome
4.
Otol Neurotol ; 44(1): 26-33, 2023 01 01.
Article in English | MEDLINE | ID: mdl-36384874

ABSTRACT

OBJECTIVE: Cochlear nerve deficiency (CND) is often combined with modiolar deficiency-type inner ear malformations, which cause variable cochlear implantation (CI) outcomes. We aimed to assess the postoperative development of auditory and speech perception in CND patients with modiolar deficiency-type malformations after 3 years of follow-up to determine the factors correlated with CI outcomes. METHODS: Sixty-seven CND patients with modiolar deficiency-type malformations who underwent CI surgery were retrospectively reviewed. Modiolar deficiency-type malformations included common cavity (CC), cochlear hypoplasia (CH) (including CH-I and CH-II) and incomplete partition-I (IP-I). Categorical auditory performance (CAP) and the infant-toddler meaningful auditory integration scale (MAIS) were used to assess auditory ability. The speech intelligibility rating (SIR) and meaningful use of speech scale (MUSS) were used to assess the speech intelligibility of these CI patients. The CI outcomes were evaluated at 0, 12, 24 and 36 months after implant activation. RESULTS: All patients demonstrated improvements in auditory ability and speech intelligibility after CI. There were no significant differences in CI outcomes at any time point according to the malformation type. The number of nerve bundles within the internal auditory canal (IAC) showed significant differences at 12, 24 and 36 months after CI ( p < 0.05). Patients with one nerve bundle had relatively poor CI outcomes. CONCLUSIONS: CND patients with modiolar deficiency-type malformations showed continuous improvement in auditory and speech abilities after CI. Compared with malformations, the number of nerve bundles should be given more attention when selecting the side for CI.


Subject(s)
Cochlear Implantation , Cochlear Implants , Speech Perception , Infant , Humans , Retrospective Studies , Speech Intelligibility , Cochlear Nerve/diagnostic imaging , Cochlear Nerve/abnormalities , Treatment Outcome
5.
Front Neurosci ; 16: 895560, 2022.
Article in English | MEDLINE | ID: mdl-35812216

ABSTRACT

Cochlear nerve deficiency (CND) is often associated with variable outcomes of cochlear implantation (CI). We assessed previous investigations aiming to identify the main factors that determine CI outcomes, which would enable us to develop predictive models. Seventy patients with CND and normal cochlea who underwent CI surgery were retrospectively examined. First, using a data-driven approach, we collected demographic information, radiographic measurements, audiological findings, and audition and speech assessments. Next, CI outcomes were evaluated based on the scores obtained after 2 years of CI from the Categories of Auditory Performance index, Speech Intelligibility Rating, Infant/Toddler Meaningful Auditory Integration Scale or Meaningful Auditory Integration Scale, and Meaningful Use of Speech Scale. Then, we measured and averaged the audiological and radiographic characteristics of the patients to form feature vectors, adopting a multivariate feature selection method, called stability selection, to select the features that were consistent within a certain range of model parameters. Stability selection analysis identified two out of six characteristics, namely the vestibulocochlear nerve (VCN) area and the number of nerve bundles, which played an important role in predicting the hearing and speech rehabilitation results of CND patients. Finally, we used a parameter-optimized support vector machine (SVM) as a classifier to study the postoperative hearing and speech rehabilitation of the patients. For hearing rehabilitation, the accuracy rate was 71% for both the SVM classification and the area under the curve (AUC), whereas for speech rehabilitation, the accuracy rate for SVM classification and AUC was 93% and 94%, respectively. Our results identified that a greater number of nerve bundles and a larger VCN area were associated with better CI outcomes. The number of nerve bundles and VCN area can predict CI outcomes in patients with CND. These findings can help surgeons in selecting the side for CI and provide reasonable expectations for the outcomes of CI surgery.

6.
Foods ; 8(9)2019 Sep 16.
Article in English | MEDLINE | ID: mdl-31527534

ABSTRACT

In view of understanding the stability of sterilized 'Cara Cara' juice during storage, the changes of specific quality parameters (flavonoid, carotenoid, vitamin C, soluble sugar and antioxidant activities) of 'Cara Cara' juice were systematically investigated over the course of 16 weeks in storage at 4, 20, 30 and 40 °C. Total flavonoid and carotenoid indexes showed slight degradation at each temperature, while vitamin C and soluble sugar degraded intensively, especially at 40 °C storage with a great amount of HMF (5-hydroxymethylfurfural) accumulated. There were 29 carotenoids detected during storage, including carotenes and carotenoid esters. Carotenes were kept stable, while the degradations of carotenoid esters were fitted by biexponential function. Carotenoid ester group 2 contained epoxy structures that quickly decreased in the first four weeks at all storage temperatures, while the ester group 1 (belonged to ß-cryptoxanthin ester) was degraded gradually. The 13- or 15-cis-lycopene, isomerized from all-(trans)-lycopene, increased with storage time at each temperature. Total flavonoid and carotenoid indexes in stored 'Cara Cara' juice were positively correlated with hydrophilic and lipophilic antioxidant abilities.

SELECTION OF CITATIONS
SEARCH DETAIL
...