1.
J Arrhythm ; 40(3): 536-551, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939786

ABSTRACT

Background: We explore an optimized approach for increasing lesion size using a novel ablation catheter with a surface thermocouple and efficient irrigation in a temperature-control setting. Methods: We conducted radiofrequency applications at various power levels (35 W, 40 W, and 45 W), contact forces (CFs, 10 g/20 g), and durations (60 s/120 s/180 s) in perpendicular/parallel catheter orientations, with normal saline irrigation (NS-irrigation) and Half NS-irrigation (HNS-irrigation) in an ex-vivo model (Step 1). In addition, we performed applications (35 W/40 W/45 W for 60 s/120 s/180 s in NS-irrigation and 35 W/40 W for 60 s/120 s/180 s in HNS-irrigation) in four swine (Step 2), evaluating lesion characteristics and the occurrence of steam pops. Results: In Step 1, out of 288 lesions, we observed 47 (16.3%) steam pops, with 13 in NS-irrigation and 34 in HNS-irrigation (p = .001). Although steam pops were mostly observed with the most aggressive setting (45 W/180 s, 54%) with NS-irrigation, they happened in less aggressive settings with HNS irrigation. Lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. The optimal %impedance-drop cutoff to predict steam pops was 20% with a negative-predictive-value (NPV) = 95.1% including NS- and HNS-irrigation groups, and 22% with an NPV = 96.1% in NS-irrigation group. In Step 2, similar to the ex-vivo model, lesion size significantly increased with longer-duration ablation but not with HNS-irrigation. Steam pops were absent with NS-irrigation (0/35) even with the largest %impedance-drop reaching 31% at 45 W/180 s. All steam pops were observed with HNS-irrigation (6/21, 29%). The optimal %impedance-drop cutoff predicting steam pops was 24% with an NPV = 96.3% including both NS- and HNS-irrigation groups. Conclusions: Rather than using HNS-irrigation, very long-duration of radiofrequency applications up to 45 W/180 s may be recommended to safely and effectively increase lesion dimensions using this catheter with NS-irrigation.

2.
Article in English | MEDLINE | ID: mdl-38880852

ABSTRACT

BACKGROUND: The innovative peak frequency mapping facilitates the quantification of electrogram sharpness. However, reference values for normal atrial tissue are currently undefined. In this study, we explored the distribution of peak frequency and omnipolar peak-to-peak voltage (V-max) in a normal heart. METHODS: Twenty-two patients with structurally normal heart were included. Either the right atrium (RA) and superior vena cava (SVC) or the left atrium (LA) and pulmonary veins (PVs) were mapped during sinus rhythm. RESULTS: In total, 13,654 points in the RA and 4143 points in the SVC from 15 patients and 4662 points in the LA and 2761 points in PVs from 7 patients were analyzed. The correlation between peak frequency and V-max was weak (R = 0.223). The median peak frequency was larger in the SVC than in the RA (441 [358-524] Hz vs. 358 [291-441] Hz, P < 0.0001) and in PVs than in the LA (346 [253-441] Hz vs. 323 [262-397] Hz, P < 0.0001). Conversely, the median V-max was smaller in the SVC than in the RA (1.96 [0.77-3.75] mV vs. 4.11 [2.10-6.83] mV, P < 0.0001) and in PVs than in the LA (1.16 [0.33-3.17] mV vs. 4.42 [2.63-6.84] mV, P < 0.0001). More than 95% of peak frequencies were > 174 Hz in the RA and > 185 Hz in the LA, and > 95% of V-maxes were > 0.52 and > 1.07 mV in the RA and LA, respectively. CONCLUSION: Given the limited correlation between peak frequency and V-max, and recognizing their potential to provide distinct information, they can be used complementarily. Employing these parameters to extract varied insights can provide comprehensive understandings of tissue characteristics.

3.
Int J Chron Obstruct Pulmon Dis ; 19: 1123-1130, 2024.
Article in English | MEDLINE | ID: mdl-38803411

ABSTRACT

Background: Reports from Europe and North America suggest that female chronic obstructive pulmonary disease (COPD) patients have a higher symptom burden and mortality than male patients. However, little is known about the management reality of female patients with COPD in Japan. Patients and Methods: We compared the clinical characteristics of female COPD patients with those of male using the cohort of the COPD Assessment in Practice study, which is a cross-sectional multicenter observational study. Results: Of the 1168 patients, 133 (11.4%) were female. A history of never smoking was higher in females than males (p<0.01). Although there was no difference in age or forced expiratory volume in one second (FEV1) % predicted between the groups, modified medical research council dyspnea scale (mMRC) and number of frequent exacerbators were higher in females (mMRC≥2: p<0.01; number of exacerbations≥2: p=0.011). The mean forced vital capacity and FEV1 values in females were lower than those in males (p<0.0001 and p<0.0001, respectively). Females were more likely to use long-term oxygen therapy and inhaled corticosteroids than males (p=0.016 and p<0.01, respectively). The prevalence of the Global Initiative for Chronic Obstructive Lung Disease (GOLD) groups B, C, D (ABCD GOLD 2017 classification), and E (ABE GOLD 2023 classification) was higher in females than in males. Conclusion: The disease burden of female patients with COPD is higher than that of male patients in Japan, suggesting the importance of interventions considering female-dominant features such as lower absolute FVC and FEV1, respiratory failure, and asthma-like conditions.


Subject(s)
Lung , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/epidemiology , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/physiopathology , Pulmonary Disease, Chronic Obstructive/therapy , Female , Cross-Sectional Studies , Japan/epidemiology , Male , Aged , Forced Expiratory Volume , Middle Aged , Sex Factors , Lung/physiopathology , Lung/drug effects , Vital Capacity , Prevalence , Healthcare Disparities , Risk Factors , Oxygen Inhalation Therapy , Disease Progression , Adrenal Cortex Hormones/therapeutic use , Adrenal Cortex Hormones/administration & dosage , Treatment Outcome , Smoking/epidemiology , Smoking/adverse effects , Health Status Disparities , Aged, 80 and over , Bronchodilator Agents/therapeutic use
4.
J Arrhythm ; 40(2): 247-255, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38586837

ABSTRACT

Background: Lesion size is reported to become larger as contact force (CF) increases. However, this has not been systematically evaluated in temperature-guided very high-power short-duration (vHPSD) ablation, which was therefore the purpose of this study. Methods: Radiofrequency applications (90 W/4 s, temperature-control mode) were performed in excised porcine myocardium with four different CFs of 5, 15, 25, and 35 g using QDOT-MICRO™ catheter. Ten lesions for each combination of settings were created, and lesion metrics and steam-pops were compared. Results: A total of 320 lesions were analyzed. Lesion depth, surface area, and volume were smallest for CF of 5 g than for 15, 25, and 35 g (depth: 2.7 mm vs. 2.9 mm, 3.0 mm, 3.15 mm, p < .01; surface area: 38.4 mm2 vs. 41.8 mm2, 43.3 mm2, 41.5 mm2, p < .05; volume: 98.2 mm3 vs. 133.3 mm3, 129.4 mm3, 126.8 mm3, p < .01 for all pairs of groups compared to CF = 5 g). However, no significant differences were observed between CFs of 15-35 g. Average power was highest for CF of 5 g, followed by 15, 25, and 35 g (83.2 W vs. 82.1 W vs. 77.1 W vs. 66.1 W, p < .01 for all pairs), reflecting the higher incidence of temperature-guided power titration with greater CFs (5 g:8.8% vs. 15 g:52.5% vs. 25 g:77.5% vs. 35 g:91.2%, p < .01 for all pairs except for 25 g vs. 35 g). The incidence of steam-pops did not significantly differ between four groups (5 g:3.8% vs. 15 g:10% vs. 25 g:6.2% vs. 35 g:2.5%, not significant for all pairs). Conclusions: For vHPSD ablation, lesion size does not become large once the CF reaches 15 g, and the risk of steam-pops may be mitigated through power titration even in high CFs.

5.
Heart Rhythm ; 2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38460753

ABSTRACT

BACKGROUND: Unipolar electrograms (uni-EGMs) are an essential part of intracardiac mapping. Although Wilson central terminal (WCT) is conventionally used as a reference for signals, avoidance of contamination by far-field and nonphysiologic signals is challenging. OBJECTIVE: The aim of the study was to explore the impact of an intracardiac indifferent reference electrode close to the recording electrodes, in lieu of WCT, on electrograms. METHODS: Sinus node activation was mapped in patients undergoing catheter ablation by a multielectrode array with a close indifferent electrode (CIE) embedded in the distal end of the catheter shaft. An equal number of points was sequentially acquired at each site with use of CIE as a reference first and subsequently with WCT. Uni-EGMs, bipolar EGMs, and the earliest activation area (defined as the area activated in the first 10 ms of the beat) were compared between CIE- and WCT-based activation maps. RESULTS: Seventeen patients (61 ± 18 years; 76% male) were studied. Uni-EGM voltages acquired with CIE were significantly larger than (n = 11) or comparable to (n = 4) those acquired with WCT. When points from the entire cohort were analyzed altogether, unipolar voltages and their maximum negative dV/dT and bipolar voltages recorded with CIE were significantly larger than those recorded with WCT (2.36 [1.42-3.79] mV vs 1.96 [1.25-3.03] mV, P < .0001; 0.40 [0.18-0.77] mV/s vs 0.35 [0.15-0.71] mV/s, P < .0001; and 1.46 [0.66-2.81] mV vs 1.33 [0.54-2.64] mV, P < .0001, respectively). The earliest activation area was significantly smaller in CIE-based activation maps than in WCT-based ones (0.3 [0.7-1.4] cm2 vs 0.6 [1.0-1.8] cm2, P = .01). CONCLUSION: CIE-based maps were associated with an approximately 20% increase in unipolar voltage and may highlight the origin of a focal activation more clearly than WCT-based ones.

6.
Clin Cardiol ; 47(1): e24164, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37822107

ABSTRACT

BACKGROUND: A left atrial posterior wall isolation (LAPWI) is one of the atrial fibrillation (AF) ablation strategies. HYPOTHESIS: We hypothesized that an additional empirical LAPWI would increase the freedom from recurrent atrial arrhythmias as compared to standard AF ablation in persistent AF patients. METHODS: The CORNERSTONE AF study is a prospective, randomized, multicenter study investigating patients with AF persisting for >7 days and <3 years undergoing first-time AF ablation. They will be randomized to pulmonary vein isolation (PVI) or PVI + LAPWI in a 1:1 manner. Although PVI can be performed with either radiofrequency catheters or cryoballoons, only radiofrequency catheters will be permitted to achieve LAPWIs. Additional focal ablation targeting non-pulmonary vein triggers will be allowed. A total of 516 patients will be enrolled in 17 centers between August 2022 and February 2024 based on the calculation with 80% power, considering the assumption that 65% and 75% of the PVI and PVI + LAPWI group patients will be free from atrial arrhythmia recurrence 18-months postprocedure (10% of dropout). The primary endpoint is freedom from documented atrial arrhythmias 18 months postsingle procedures. Clinical follow-up will include 7-day ambulatory electrocardiograms and routine outpatient consultations by electrophysiologists at 1, 3, 6, 9, 12, and 18 months postprocedure. RESULTS: As of August 2023, a total of 331 patients (68 ± 9 years, 270 men, 43 longstanding persistent AF) have been enrolled. CONCLUSIONS: The CORNERSTONE AF study is a prospective, randomized, multicenter trial designed to evaluate the efficacy and safety of an adjunctive empirical LAPWI following standard AF ablation in persistent AF patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria , Multicenter Studies as Topic , Prospective Studies , Pulmonary Veins/surgery , Randomized Controlled Trials as Topic , Recurrence , Treatment Outcome
7.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38096246

ABSTRACT

AIMS: The usefulness of coronary venous system mapping has been reported for assessing intramural and epicardial substrates in patients with scar-related ventricular tachycardia (VT). However, there has been little data on mapping from coronary arteries. We investigated the safety and utility of mapping from coronary arteries with a novel over-the-wire multielectrode catheter in scar-related VT patients. METHODS AND RESULTS: Ten consecutive scar-related VT patients with non-ischaemic cardiomyopathy who underwent mapping from a coronary artery were analysed. Six patients underwent simultaneous coronary venous mapping. High-density maps were created by combining the left ventricular endocardium and coronary vessels. Substrate maps were created during the baseline rhythm with 2438 points (IQR 2136-3490 points), including 329 (IQR 59-508 points) in coronary arteries. Abnormal bipolar electrograms were successfully recorded within coronary arteries close to the endocardial substrate in seven patients. During VT, isthmus components were recorded within the coronary vessels in three patients with no discernible isthmus components on endocardial mapping. The ablation terminated the VT from an endocardial site opposite the earliest site in the coronary arteries in five patients. CONCLUSION: The transcoronary mapping with an over-the-wire multielectrode catheter can safely record abnormal bipolar electrograms within coronary arteries. Additional mapping data from the coronary vessels have the potential to assess three-dimensional ventricular substrates and circuit structures in scar-related VT patients.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Cicatrix/complications , Cicatrix/diagnostic imaging , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/surgery , Arrhythmias, Cardiac , Heart Ventricles , Endocardium , Catheter Ablation/adverse effects , Catheter Ablation/methods
8.
Pacing Clin Electrophysiol ; 46(12): 1536-1545, 2023 12.
Article in English | MEDLINE | ID: mdl-37957924

ABSTRACT

BACKGROUND AND AIMS: The safety evaluation of TactiFlex, a novel contact-force sensing catheter with a flexible 4-mm tip irrigated through laser-cut kerfs, has been ongoing. This study aimed to verify the safety of this type of catheter. METHODS: Study 1: Radiofrequency (RF) applications at a range of powers (30-50 W), contact forces (10-20 g), and durations (10-60 s) using perpendicular/parallel catheter orientation with half-normal (HNS) or normal saline irrigation were compared between TactiFlex (4-mm tip) and TactiCath (3.5-mm tip) with temperature-controlled mode in excised porcine hearts. Study 2: The relation between RF applications using TactiFlex and the incidence of steam-pops in the real clinical cases were examined. RESULTS: Study-1: 576 RF lesions were examined. TactiFlex demonstrated a significantly lower risk of steam-pops (5[1.7%] vs. 59[20.5%], p < .0001). Compared to 3.5-mm-tip catheter (TactiCath), 4-mm-tip catheter (TactiFlex) produced smaller lesion volume at perpendicular (193[98-554]mm3 vs. 263[139-436]mm3 , p < .0001), but relatively similar lesion volume at parallel contact (243[105-443]mm3 vs. 278[180-440]mm3 , p = .06). HNS-irrigation tended to increase the lesion volume in both catheters and to increase the incidence of steam-pops with TactiCath, but not with TactiFlex. The cut-off value of %impedance-drop ( = absolute impedance-drop/initial impedance) of 20% predicted steam-pops with a sensitivity = 100% and specificity = 89.6% in TactiFlex. Study-2: 5496 RF applications in 84 patients (51AFs/8ATs/3AVNRTs/4AVRTs/17PVCs/4VTs) using TactiFlex were analyzed. Four steam-pops (0.07%) in three patients with pericardial effusion were observed (%impedance-drop = 24%/26%/29%/35%, respectively). The cut-off value of %impedance-drop = 20%, derived from ex-vivo study, showed sensitivity = 100% and specificity = 90.1% in detecting steam-pops. CONCLUSION: TactiFlex reduced the risk of steam-pops than TactiCath. %impedance-drop ≤ 20% may be reasonable for safely use with a sufficient safety margin. For 4-mm-tip catheter, parallel-contact may be recommended for larger lesion creation.


Subject(s)
Catheter Ablation , Steam , Humans , Animals , Swine , Therapeutic Irrigation , Equipment Design , Catheters
9.
Article in English | MEDLINE | ID: mdl-37946002

ABSTRACT

PURPOSE: Radiofrequency (RF) ablation with half-normal saline (HNS) irrigation is reported to potentially enlarge local lesion compared to normal saline (NS) in power-controlled ablation (PC-Abl). However, the effect of HNS-irrigation in temperature-flow-controlled ablation (TFC-Abl) on lesion characteristics is unknown. We compared this between TFC-Abl with QDOT-Micro™ catheter and PC-Abl with Thermocool SmartTouch SF™ catheter (STSF). METHODS: RF-application with NS (n = 480) and HNS (n = 480) irrigation were performed on swine myocardium placed in a circulating saline bath. Lesion characteristics without steam-pops under various conditions (target AI, 400/550; ablation power, 30/50 W; contact force, 10/20/30 g; catheter orientation, perpendicular/parallel) were assessed and compared between two irrigants. RESULTS: After matching, 343 lesions without steam-pops in each group were evaluated. In PC-Abl, lesion size did not differ between two groups (NS, 188 ± 97 vs. HNS, 200 ± 95 mm3, p = 0.28 in volume; 33.9 ± 7.3 vs. 34.8 ± 9.5 mm2, p = 0.34 in surface area; and 4.0 ± 1.0 vs. 4.0 ± 1.0 mm, p = 0.81 in depth), but steam-pops were more frequently observed with HNS-irrigation (23.8% vs. 37.9%, p = 0.001). Contrary, in TFC-Abl, HNS-irrigation produced significantly larger (214 ± 106 vs. 243 ± 128 mm3, p = 0.017) and deeper (4.0 ± 1.0 vs. 4.3 ± 1.1 mm, p = 0.002) lesions without increasing the risk of steam-pops (15.0% vs 15.0%, p = 0.99). Automatic temperature-guided titration was more frequently observed in HNS-irrigation (54.8% vs. 78.5%, p < 0.001). CONCLUSIONS: TFC-Abl with QDOT-Micro™ catheter utilizing HNS-irrigation might increase volume and depth of local lesion without increasing the risk of stem-pops compared to NS-irrigation. Power-controlled ablation with HNS-irrigation showed similar focal lesion with higher incidence of steam-pops (SPs) compared to normal saline (NS) irrigation. Contrary, temperature-flow-controlled ablation with HNS-irrigation provided larger and deeper lesion than NS-irrigation with similar incidence of SPs. ns, p > 0.05; *, 0.01 < p ≤ 0.05; **, 0.005 < p ≤ 0.01. HNS, half-normal saline; NS, normal saline.

10.
Circ J ; 87(12): 1757-1764, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37899173

ABSTRACT

BACKGROUND: For lesion size prediction, each input parameter, including ablation energy (AE), and output parameter, such as impedance, is individually used. We hypothesize that using both parameters simultaneously may be more optimal.Methods and Results: Radiofrequency applications at a range of power (30-50 W), contact force (10 g and 20 g), duration (10-60 s), and catheter orientation with normal saline (NS)- or half-normal saline (HNS)-irrigation were performed in excised porcine hearts. The correlations, with lesion size of AE, absolute impedance drop (∆Imp-drop), relative impedance drop (%Imp-drop), and AE*%Imp-drop were examined. Lesion size was analyzed in 283 of 288 lesions (NS-irrigation, n=142; HNS-irrigation, n=141) without steam pops. AE*%Imp-drop consistently showed the strongest correlations with lesion maximum depth (NS-irrigation, ρ=0.91; HNS-irrigation, ρ=0.94), surface area (NS-irrigation, ρ=0.87; HNS-irrigation, ρ=0.86), and volume (NS-irrigation, ρ=0.94; HNS-irrigation, ρ=0.94) compared with the other parameters. Moreover, compared with AE alone, AE*%Imp-drop significantly improved the strength of correlation with lesion maximum depth (AE vs. AE*%Imp-drop, ρ=0.83 vs. 0.91, P<0.01), surface area (ρ=0.73 vs. 0.87, P<0.01), and volume (ρ=0.84 vs. 0.94, P<0.01) with NS-irrigation. This tendency was also observed with HNS-irrigation. Parallel catheter orientation showed a better correlation with lesion depth and volume using ∆Imp-drop, %Imp-drop, and AE*%Imp-drop than perpendicular orientation. CONCLUSIONS: The combination of input and output parameters is more optimal than each single parameter for lesion prediction.


Subject(s)
Catheter Ablation , Saline Solution , Animals , Swine , Heart Ventricles/pathology , Heart , Catheters , Catheter Ablation/methods , Equipment Design , Electric Impedance
11.
J Cardiovasc Electrophysiol ; 34(8): 1708-1717, 2023 08.
Article in English | MEDLINE | ID: mdl-37431258

ABSTRACT

BACKGROUND: The impact of filtering on bipolar electrograms (EGMs) has not been systematically examined. We tried to clarify the optimal filter configuration for ventricular tachycardia (VT) ablation. METHODS: Fifteen patients with VT were included. Eight different filter configurations were prospectively created for the distal bipoles of the ablation catheter: 1.0-250, 10-250, 100-250, 30-50, 30-100, 30-250, 30-500, and 30-1000 Hz. Pre-ablation stable EGMs with good contact (contact force > 10 g) were analyzed. Baseline fluctuation, baseline noise, bipolar peak-to-peak voltage, and presence of local abnormal ventricular activity (LAVA) were compared between different filter configurations. RESULTS: In total, 2276 EGMs with multiple bipolar configurations in 246 sites in scar and border areas were analyzed. Baseline fluctuation was only observed in the high-pass filter of (HPF) ≤ 10 Hz (p < .001). Noise level was lowest at 30-50 Hz (0.018 [0.012-0.029] mV), increased as the low-pass filter (LPF) extended, and was highest at 30-1000 Hz (0.047 [0.041-0.061] mV) (p < .001). Conversely, the HPF did not affect the noise level at ≤30 Hz. As the HPF extended to 100 Hz, bipolar voltages significantly decreased (p < .001), but were not affected when the LPF was extended to ≥100 Hz. LAVAs were most frequently detected at 30-250 Hz (207/246; 84.2%) and 30-500 Hz (208/246; 84.6%), followed by 30-1000 Hz (205/246; 83.3%), but frequently missed at LPF ≤ 100 Hz or HPF ≤ 10 Hz (p < .001). A 50-Hz notch-filter reduced the bipolar voltage by 43.9% and LAVA-detection by 34.5% (p < .0001). CONCLUSION: Bipolar EGMs are strongly affected by filter settings in scar/border areas. In all, 30-250 or 30-500 Hz may be the best configuration, minimizing the baseline fluctuation, baseline noise, and detecting LAVAs. Not applying the 50-Hz notch filter may be beneficial to avoid missing VT substrate.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Cicatrix , Catheter Ablation/adverse effects
12.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37428890

ABSTRACT

AIMS: Although the mechanism of an atrial tachycardia (AT) can usually be elucidated using modern high-resolution mapping systems, it would be helpful if the AT mechanism and circuit could be predicted before initiating mapping. OBJECTIVE: We examined if the information gathered from the cycle length (CL) of the tachycardia can help predict the AT-mechanism and its localization. METHODS: One hundred and thirty-eight activation maps of ATs including eight focal-ATs, 94 macroreentrant-ATs, and 36 localized-ATs in 95 patients were retrospectively reviewed. Maximal CL (MCL) and minimal CL (mCL) over a minute period were measured via a decapolar catheter in the coronary sinus. CL-variation and beat-by-beat CL-alternation were examined. Additionally, the CL-respiration correlation was analysed by the RhythmiaTM system. : Both MCL and mCL were significantly shorter in macroreentrant-ATs [MCL = 288 (253-348) ms, P = 0.0001; mCL = 283 (243-341) ms, P = 0.0012], and also shorter in localized-ATs [MCL = 314 (261-349) ms, P = 0.0016; mCL = 295 (248-340) ms, P = 0.0047] compared to focal-ATs [MCL = 506 (421-555) ms, mCL = 427 (347-508) ms]. An absolute CL-variation (MCL-mCL) < 24 ms significantly differentiated re-entrant ATs from focal-ATs with a sensitivity = 96.9%, specificity = 100%, positive predictive value (PPV) = 100%, and negative predictive value (NPV) = 66.7%. The beat-by-beat CL-alternation was observed in 10/138 (7.2%), all of which showed the re-entrant mechanism, meaning that beat-by-beat CL-alternation was the strong sign of re-entrant mechanism (PPV = 100%). Although the CL-respiration correlation was observed in 28/138 (20.3%) of ATs, this was predominantly in right-atrium (RA)-ATs (24/41, 85.7%), rather than left atrium (LA)-ATs (4/97, 4.1%). A positive CL-respiration correlation highly predicted RA-ATs (PPV = 85.7%), and negative CL-respiration correlation probably suggested LA-ATs (NPV = 84.5%). CONCLUSION: Detailed analysis of the tachycardia CL helps predict the AT-mechanism and the active AT chamber before an initial mapping.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Humans , Retrospective Studies , Electrophysiologic Techniques, Cardiac , Tachycardia , Heart Atria , Treatment Outcome
13.
J Cardiovasc Electrophysiol ; 34(8): 1671-1680, 2023 08.
Article in English | MEDLINE | ID: mdl-37337433

ABSTRACT

INTRODUCTION: Little is known about the impact of blood-pool local impedance (LI) on lesion characteristics and the incidence of steam pops. METHODS: Radiofrequency applications at a range of powers (30, 40, and 50 W), contact forces (CF) (5, 15, and 25 g), and durations (15, 30, 45, and 120 s) using perpendicular/parallel catheter orientation were performed in 40 excised porcine preparations, using a catheter capable of monitoring LI (StablePoint©, Boston Scientific). To simulate the variability in blood-pool impedance, the saline-pool LI was modulated by calibrating saline concentrations. Lesion characteristics were compared under three values of saline-pool LI: 120, 160, and 200 Ω. RESULTS: Of 648 lesions created, steam pops occurred in 175 (27.0%). When power, CF, time, and catheter orientation were adjusted, ablation at a saline-pool impedance of 160 or 200 Ω more than doubled the risk of steam pops compared with a saline-pool impedance of 120 Ω (Odds ratio = 2.31; p = .0002). Lesions in a saline-pool impedance of 120 Ω were significantly larger in surface area (50 [38-62], 45 [34-56], and 41 [34-60] mm2 for 120, 160, and 200 Ω, p < .05), but shallower in depth (4.0 [3-5], 4.4 [3.2-5.3], and 4.5 [3.8-5.5] mmfor 120, 160, and 200 Ω, respectively, p < .05) compared with the other two settings. The correlation between the absolute LI-drop and lesion size weakened as the saline-pool LI became higher (e.g., 120 Ω group (r2 = .30, r2 = .18, and r2 = .16, respectively for 120, 160, and 200 Ω), but the usage of %LI-drop (= absolute LI-drop/initial LI) instead of absolute LI-drop may minimize this effect. CONCLUSIONS: In an experimental model, baseline saline-pool impedance significantly affects the lesion metrics and the risk of steam pops.


Subject(s)
Catheter Ablation , Steam , Swine , Animals , Electric Impedance , Benchmarking , Catheter Ablation/adverse effects , Saline Solution
14.
Clin Case Rep ; 11(5): e7392, 2023 May.
Article in English | MEDLINE | ID: mdl-37220508

ABSTRACT

Accelerated idioventricular rhythm (AIVR) originating from the right bundle branch (RBB) (RBB-AIVR) is a rare ventricular arrhythmia. We delineated RBB and myocardial activation separately during RBB-AIVR, which revealed the spatial relationship of the AIVR origin, preferential pathway, and breakout site. Radiofrequency ablation to the preferential pathway successfully eliminated this arrhythmia.

15.
Respir Med Case Rep ; 44: 101862, 2023.
Article in English | MEDLINE | ID: mdl-37251358

ABSTRACT

Herein, we report the case of a 73-year-old woman with an occupational history of plaster grinding who developed autoimmune pulmonary alveolar proteinosis (PAP) during the treatment of fibrotic hypersensitivity pneumonitis with steroids and immunosuppressive drugs. Based on the changes in computed tomography imaging findings, poor response to steroid therapy, and markedly elevated KL-6 levels, PAP was suspected and diagnosed by bronchoscopy. Repeated segmental bronchoalveolar lavage under high-flow nasal cannula oxygen therapy resulted in slight improvement. Steroids and immunosuppressive treatments for other interstitial lung diseases may cause PAP or exacerbate latent PAP.

16.
J Cardiovasc Electrophysiol ; 34(4): 908-917, 2023 04.
Article in English | MEDLINE | ID: mdl-36906814

ABSTRACT

INTRODUCTION: The QDOT-MicroTM catheter is a novel irrigated contact force (CF) sensing catheter which benefits from thermocouples for temperature monitoring, allowing temperature-flow-controlled (TFC) ablation. We compared lesion metrics at fixed ablation index (AI) value during TFC-ablation and conventional power-controlled (PC)-ablation. METHODS: A total of 480 RF-applications were performed on ex-vivo swine myocardium with predefined AI targets (400/550) or until steam-pop occurred, using the QDOT-MicroTM (TFC-ablation) and Thermocool SmartTouch SFTM (PC-ablation). RESULTS: Both TFC-ablation and PC-ablation produced similar lesions in volume (218 ± 116 vs. 212 ± 107 mm3 , p = .65); however, lesions using TFC-ablation were larger in surface area (41.3 ± 8.8 vs. 34.8 ± 8.0 mm2 , p < .001) and shallower in depth (4.0 ± 1.0 vs. 4.2 ± 1.1 mm, p = .044). Average power tended to be lower in TFC-alation (34.2 ± 8.6 vs. 36.9 ± 9.2, p = .005) compared to PC-ablation due to automatic regulation of temperature and irrigation-flow. Although steam-pops were less frequent in TFC-ablation (24% vs. 15%, p = .021), they were particularly observed in low-CF (10 g) and high-power ablation (50 W) in both PC-ablation (n = 24/240, 10.0%) and TFC-ablation (n = 23/240, 9.6%). Multivariate analysis revealed that high-power, low-CF, long application time, perpendicular catheter orientation, and PC-ablation were risk factors for steam-pops. Furthermore, activation of automatic regulation of temperature and irrigation-flow was independently associated with high-CF and long application time while ablation power had no significant relationship. CONCLUSIONS: With a fixed target AI, TFC-ablation reduced the risk of steam-pops, producing similar lesions in volume, but with different metrics in this ex-vivo study. However, lower CF and higher power in fixed-AI ablation may increase the risk of steam-pops.


Subject(s)
Catheter Ablation , Steam , Swine , Animals , Temperature , Catheter Ablation/adverse effects , Therapeutic Irrigation/adverse effects , Equipment Design
17.
Europace ; 25(4): 1400-1407, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36892146

ABSTRACT

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Kidney Failure, Chronic , Thromboembolism , Humans , Female , Male , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Anticoagulants/adverse effects , Hemorrhage/chemically induced , Thromboembolism/etiology , Thromboembolism/prevention & control , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/therapy , Catheter Ablation/adverse effects , Registries
18.
Respir Investig ; 61(2): 186-189, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36724582

ABSTRACT

BACKGROUND: Although pulmonary function tests (PFTs) are important in patients with interstitial lung disease (ILD), they cannot be easily performed in a primary healthcare setting. This study aimed to examine the usefulness of the difference between pulse oxygen saturation (SpO2) at rest and the lowest SpO2 during the 1-min sit-to-stand test (delta SpO2-1STST) for predicting pulmonary function impairment. METHODS: We retrospectively reviewed 116 patients with ILD who underwent 1STST and PFTs. RESULTS: The delta SpO2-1STST and diffusing capacity for carbon monoxide (DLco) strongly correlated (ρ = 0.70). The delta SpO2-1STST was effective in predicting impaired gas exchange (cut-off value, -4%; AUC, 0.86; sensitivity, 74%; specificity, 87%). CONCLUSIONS: The Delta SpO2-1STST may be a reasonable tool for predicting abnormalities in PFTs.


Subject(s)
Lung Diseases, Interstitial , Pulmonary Diffusing Capacity , Humans , Retrospective Studies , Lung Diseases, Interstitial/diagnosis , Lung , Respiratory Function Tests
19.
Biomolecules ; 13(2)2023 01 22.
Article in English | MEDLINE | ID: mdl-36830583

ABSTRACT

The use of inhaled corticosteroids (ICS) for the maintenance of bronchodilator treatment in patients with chronic obstructive pulmonary disease (COPD) is controversial. While some patients achieve clinical benefits, such as fewer exacerbations and improved symptoms, others do not, and some experience undesired side effects, such as pneumonia. Thus, we reviewed the evidence related to predictors of ICS therapy treatment response in patients with COPD. The first priority clinical markers when considering the efficacy of ICS are type 2 inflammatory biomarkers, followed by a history of suspected asthma and recurrent exacerbations. It is also necessary to consider any potential infection risk associated with ICS, and several risk factors for pneumonia when using ICS have been clarified in recent years. In this article, based on the evidence supporting the selection of ICS for COPD, we propose an ICS composite that can be added to the COPD (ICO) chart for use in clinical practice. The chart divided the type 2 biomarkers into three ranges and provided recommendations (recommend, consider, and against) by combining the history of suspected asthma, history of exacerbations, and risk of infection.


Subject(s)
Asthma , Pneumonia , Pulmonary Disease, Chronic Obstructive , Humans , Adrenal Cortex Hormones/therapeutic use , Pulmonary Disease, Chronic Obstructive/drug therapy , Pneumonia/drug therapy , Biomarkers , Asthma/drug therapy
20.
J Cardiovasc Electrophysiol ; 34(4): 888-897, 2023 04.
Article in English | MEDLINE | ID: mdl-36852902

ABSTRACT

BACKGROUND/OBJECTIVES: The QDOT-MICRO™ catheter allows very high-power and short-duration (vHPSD) ablation. This study aimed to investigate lesion characteristics using different ablation settings. METHODS: Radiofrequency applications (90 W/4 s, temperature-control mode with 55°C or 60°C target) were performed in excised porcine myocardium using three different approaches: single (SA), double nonrepetitive (DNRA), and double repetitive applications (DRA). Applications were performed with an interval of 1 min for DNRA, and without interval for DRA. RESULTS: A total of 480 lesions were analyzed. Lesion depth and volume were largest for DRA followed by DNRA and SA regardless of catheter direction (depth: 3.8 vs. 3.3 vs. 2.6 mm, p < .001 for all comparisons; volume: 176.6 vs. 145.1 vs. 97.0 mm3 , p < .001 for all comparisons). Surface area was significantly larger for DRA than for SA (45.1 vs. 38.3 mm2 , p < .001) and larger for DNRA than for SA (44.5 vs. 38.3 mm2 , p < .001), but was similar between DRA and DNRA (45.1 vs. 44.5 mm2 , p = .54). Steam-pops more frequently occurred for DRA than for SA (15.6% vs. 4.4%, p = .004) and DNRA (15.6% vs. 6.9%, p = .061), but the incidence was similar between SA and DNRA (4.4% vs. 6.9%, p = 1). Although surface area and lesion volume were larger in lesions with steam-pops than without steam-pops (46.5 vs. 38.1 mm2 , p = .018 and 128.3 vs. 96.8 mm3 , p = .068, respectively), lesions were not deeper (pop(+): 2.5 mm vs. pop(-): 2.6 mm, p = .75). CONCLUSIONS: DNRA produces larger lesions than SA without increasing the risk of steam-pops. DRA produces the largest lesions among the three groups, but with an increased risk of steam-pops. Even with steam-pops, lesions do not become deeper in vHPSD ablation.