Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 395
Filter
1.
Transl Oncol ; 45: 101993, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38743988

ABSTRACT

BACKGROUND: To construct and validate the CT-based radiomics model for predicting the tyrosine kinase inhibitors (TKIs) effects in osteosarcoma (OS) patients with pulmonary metastasis. METHODS: OS patients with pulmonary metastasis treated with TKIs were randomly separated into training and testing cohorts (2:1 ratio). Radiomic features were extracted from the baseline unenhanced chest CT images. The random survival forest (RSF) and Kaplan-Meier survival analyses were performed to construct and evaluate radiomics signatures (R-model-derived). The univariant and multivariant Cox regression analyses were conducted to establish clinical (C-model) and combined models (RC-model). The discrimination abilities, goodness of fit and clinical benefits of the three models were assessed and validated in both training and testing cohorts. RESULTS: A total of 90 patients, 57 men and 33 women, with a mean age of 18 years and median progression-free survival (PFS) of 7.2 months, were enrolled. The R-model was developed with nine radiomic features and demonstrated significant predictive and prognostic values. In both training and testing cohorts, the time-dependent area under the receiver operating characteristic curves (AUC) of the R-model and RC-model exhibited obvious superiority over C-model. The calibration and decision curve analysis (DCA) curves indicated that the accuracy of the R-model was comparable to RC-model, which exhibited significantly better performance than C-model. CONCLUSIONS: The R-model showed promising potential as a predictor for TKI responses in OS patients with pulmonary metastasis. It can potentially identify pulmonary metastatic OS patients most likely to benefit from TKIs treatment and help guide optimized clinical decisions.

2.
Int J Oral Sci ; 16(1): 38, 2024 May 11.
Article in English | MEDLINE | ID: mdl-38734708

ABSTRACT

Periodontitis is a chronic inflammatory and immune reactive disease induced by the subgingival biofilm. The therapeutic effect for susceptible patients is often unsatisfactory due to excessive inflammatory response and oxidative stress. Sinensetin (Sin) is a nature polymethoxylated flavonoid with anti-inflammatory and antioxidant activities. Our study aimed to explore the beneficial effect of Sin on periodontitis and the specific molecular mechanisms. We found that Sin attenuated oxidative stress and inflammatory levels of periodontal ligament cells (PDLCs) under inflammatory conditions. Administered Sin to rats with ligation-induced periodontitis models exhibited a protective effect against periodontitis in vivo. By molecular docking, we identified Bach1 as a strong binding target of Sin, and this binding was further verified by cellular thermal displacement assay and immunofluorescence assays. Chromatin immunoprecipitation-quantitative polymerase chain reaction results also revealed that Sin obstructed the binding of Bach1 to the HMOX1 promoter, subsequently upregulating the expression of the key antioxidant factor HO-1. Further functional experiments with Bach1 knocked down and overexpressed verified Bach1 as a key target for Sin to exert its antioxidant effects. Additionally, we demonstrated that Sin prompted the reduction of Bach1 by potentiating the ubiquitination degradation of Bach1, thereby inducing HO-1 expression and inhibiting oxidative stress. Overall, Sin could be a promising drug candidate for the treatment of periodontitis by targeting binding to Bach1.


Subject(s)
Basic-Leucine Zipper Transcription Factors , Oxidative Stress , Periodontitis , Ubiquitination , Oxidative Stress/drug effects , Periodontitis/drug therapy , Periodontitis/prevention & control , Periodontitis/metabolism , Animals , Basic-Leucine Zipper Transcription Factors/metabolism , Ubiquitination/drug effects , Rats , Male , Disease Models, Animal , Antioxidants/pharmacology , Rats, Sprague-Dawley , Humans , Chromatin Immunoprecipitation , Blotting, Western , Real-Time Polymerase Chain Reaction , Molecular Docking Simulation , Periodontal Ligament/drug effects , Periodontal Ligament/metabolism , Periodontal Ligament/cytology
3.
J Clin Periodontol ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38736143

ABSTRACT

AIM: To investigate the association between periodontal macrophage polarization states and the alveolar bone levels, and to assess whether glycosylated nano-hydroxyapatites (GHANPs) could improve bone regeneration in periodontitis by inducing macrophage M2 polarization. MATERIALS AND METHODS: The change of macrophage polarization state in inflammatory periodontal tissues (with bone loss) was examined using clinical gingival samples. The relationship between macrophage phenotype and bone level in periodontal bone loss and repair was evaluated using a mouse periodontitis model. The effect of GHANPs on macrophage polarization was assessed by the in vitro model of lipopolysaccharide (LPS)-stimulated inflammation. The polarization-related markers were detected by immunofluorescence staining, real-time polymerase chain reaction and enzyme-linked immunosorbent assay analysis. The therapeutic effect of GHANPs on alveolar bone loss was explored in experimental periodontitis by histological staining and micro-CT analysis. RESULTS: A lower macrophage M2/M1 ratio was observed in periodontitis-affected human gingival tissues. The results of animal experiments demonstrated a positive correlation between a lower Arg-1/iNOS ratio and accelerated alveolar bone loss; also, the proportion of Arg-1-positive macrophages increased during bone repair and regeneration. The administration of GHANPs partially restored M2 macrophage polarization after LPS stimulation. GHANPs increased alveolar bone repair and regeneration in experimental periodontitis induced by ligation, potentially related to their macrophage M2 transition regulation. CONCLUSIONS: The findings of this study indicate that the induction of macrophage M2 polarization can be considered a viable approach for enhancing inflammatory bone repair. Additionally, GHANPs show potential in the clinical treatment of periodontitis.

4.
J Cardiothorac Surg ; 19(1): 205, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38615019

ABSTRACT

BACKGROUND: To date, the extended Morrow procedure is considered the gold standard treatment for patients with obstructive hypertrophic cardiomyopathy who experience severe symptoms and are unresponsive to medication treatment. We therefore aimed to perform transapical intramyocardial septal microwave ablation to reduce the thickness of the interventricular septum myocardium in a minimally invasive method. METHODS: Fourteen swine were divided to form either a microwave ablation group (n = 7) or a sham group (n = 7). In the microwave ablation group, a transapical microwave antenna was inserted into the septum to ablate each myocardial segment at 40 W for 1 min, while in the sham group, the same operation was performed but without power output. We used echocardiography, electrocardiogram, during the operation. And added computerized tomography, cardiac nuclear magnetic resonance during follow-up. RESULTS: Segment hypokinesis was observed in all swine immediately following ablation. Compared with the sham group, the thickness of ablated segments in the ablation group decreased significantly 1 month post-operation (ablation group, 5.53 ± 1.00 mm vs. 8.03 ± 1.15 mm, respectively, P < 0.01; sham group, 8.40 ± 0.94 mm vs. 8.21 ± 1.09 mm, respectively, P = 0.081), and the outcome was still observed 1 year post-operation (ablation group, 3.36 ± 0.85 mm vs. 8.03 ± 1.15 mm, respectively, P < 0.01). No perforation of the septum was observed during the procedure or follow-up, and no heart failure or sudden cardiac death occurred during postoperative feeding. CONCLUSIONS: Transapical intramyocardial septal microwave ablation can effectively and safely produce a large region of necrosis. This technique can potentially mimic surgical myectomy while avoiding cardiopulmonary bypass and median sternotomy in high-risk hypertrophic obstructive cardiomyopathy patients.


Subject(s)
Cardiomyopathy, Hypertrophic , Catheter Ablation , Humans , Animals , Swine , Microwaves/therapeutic use , Cardiomyopathy, Hypertrophic/surgery , Heart , Myocardium
5.
Eur Radiol ; 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38676731

ABSTRACT

OBJECTIVES: This study aimed to compare the image quality and diagnostic performance of standard-resolution (SR) and ultra-high-resolution (UHR) coronary CT angiography (CCTA) based on photon-counting detector CT (PCD-CT) of coronary stents and explore the best reconstruction kernel for stent imaging. METHODS: From July 2023 to September 2023, patients were enrolled to undergo CCTA using a dual-source PCD-CT system after coronary angioplasty with stent placement. SR images with a slice thickness/increment of 0.6/0.4 mm were reconstructed using a vascular kernel (Bv48), while UHR images with a slice thickness/increment of 0.2/0.2 mm were reconstructed using vascular kernels of six sharpness levels (Bv48, Bv56, Bv60, Bv64, Bv72, and Bv76). The in-stent lumen diameters were evaluated. Subjective image quality was also evaluated by a 5-point Likert scale. Invasive coronary angiography was conducted in 12 patients (25 stents). RESULTS: Sixty-nine patients (68.0 [61.0, 73.0] years, 46 males) with 131 stents were included. All UHR images had significantly larger in-stent lumen diameter than SR images (p < 0.001). Specifically, UHR-Bv72 and UHR-Bv76 for in-stent lumen diameter (2.17 [1.93, 2.63] mm versus 2.20 [1.93, 2.59] mm) ranked the two best kernels. The subjective analysis demonstrated that UHR-Bv72 images had the most pronounced effect on reducing blooming artifacts, showcasing in-stent lumen and stent demonstration, and diagnostic confidence (p < 0.001). Furthermore, SR and UHR-Bv72 images showed a diagnostic accuracy of 78.3% (95% confidence interval [CI]: 56.3%-92.5%) and 88.0% (95%CI: 68.8%-97.5%), respectively. CONCLUSION: UHR CCTA by PCD-CT leads to significantly improved visualization and diagnostic performance of coronary stents, and Bv72 is the optimal reconstruction kernel showing the stent struts and in-stent lumen. CLINICAL RELEVANCE STATEMENT: The significantly improved visualization of coronary stents using ultra-high resolution CCTA could increase the diagnostic accuracy for in-stent restenosis and avoid unnecessary invasive quantitative coronary angiography, thus changing the clinical management for patients after percutaneous coronary intervention. KEY POINTS: Coronary stent imaging is challenging with energy-integrating detector CT due to "blooming artifacts." UHR images using a PCD-CT enhanced coronary stent visualization. UHR coronary stent imaging demonstrated improved diagnostic accuracy in clinical settings.

6.
Med Image Anal ; 95: 103173, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38657424

ABSTRACT

Quantitative susceptibility mapping (QSM) is an MRI-based technique that estimates the underlying tissue magnetic susceptibility based on phase signal. Deep learning (DL)-based methods have shown promise in handling the challenging ill-posed inverse problem for QSM reconstruction. However, they require extensive paired training data that are typically unavailable and suffer from generalization problems. Recent model-incorporated DL approaches also overlook the non-local effect of the tissue phase in applying the source-to-field forward model due to patch-based training constraint, resulting in a discrepancy between the prediction and measurement and subsequently suboptimal QSM reconstruction. This study proposes an unsupervised and subject-specific DL method for QSM reconstruction based on implicit neural representation (INR), referred to as INR-QSM. INR has emerged as a powerful framework for learning a high-quality continuous representation of the signal (image) by exploiting its internal information without training labels. In INR-QSM, the desired susceptibility map is represented as a continuous function of the spatial coordinates, parameterized by a fully-connected neural network. The weights are learned by minimizing a loss function that includes a data fidelity term incorporated by the physical model and regularization terms. Additionally, a novel phase compensation strategy is proposed for the first time to account for the non-local effect of tissue phase in data consistency calculation to make the physical model more accurate. Our experiments show that INR-QSM outperforms traditional established QSM reconstruction methods and the compared unsupervised DL method both qualitatively and quantitatively, and is competitive against supervised DL methods under data perturbations.

7.
Article in English | MEDLINE | ID: mdl-38587689

ABSTRACT

PURPOSE: We aimed to evaluate the reproducibility of computed tomography (CT) radiomic features (RFs) about Epicardial Adipose Tissue (EAT). The features derived from coronary photon-counting computed tomography (PCCT) angiography datasets using the PureCalcium (VNCPC) and conventional virtual non-contrast (VNCConv) algorithm were compared with true non-contrast (TNC) series. METHODS: RFs of EAT from 52 patients who underwent PCCT were quantified using VNCPC, VNCConv, and TNC series. The agreement of EAT volume (EATV) and EAT density (EATD) was evaluated using Pearson's correlation coefficient and Bland-Altman analysis. A total of 1530 RFs were included. They are divided into 17 feature categories, each containing 90 RFs. The intraclass correlation coefficients (ICCs) and concordance correlation coefficients (CCCs) were calculated to assess the reproducibility of RFs. The cutoff value considered indicative of reproducible features was > 0.75. RESULTS: the VNCPC and VNCConv tended to underestimate EATVs and overestimate EATDs. Both EATV and EATD of VNCPC series showed higher correlation and agreement with TNC than VNCConv series. All types of RFs from VNCPC series showed greater reproducibility than VNCConv series. Across all image filters, the Square filter exhibited the highest level of reproducibility (ICC = 67/90, 74.4%; CCC = 67/90, 74.4%). GLDM_GrayLevelNonUniformity feature had the highest reproducibility in the original image (ICC = 0.957, CCC = 0.958), exhibiting a high degree of reproducibility across all image filters. CONCLUSION: The accuracy evaluation of EATV and EATD and the reproducibility of RFs from VNCPC series make it an excellent substitute for TNC series exceeding VNCConv series.

8.
IEEE Trans Biomed Eng ; PP2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38530718

ABSTRACT

Magnetic resonance elastography (MRE) of brain relies on inducing and measuring shear waves in the brain. However, studies have shown vibration could induce changes in cerebral blood flow (CBF), which has a modulation effect and can affect the biomechanical properties measured. OBJECTIVE: This work demonstrates the initial prototype of the indirect excitation method, which can generate shear waves in the brain with minimal changes in CBF. METHODS: A simple system was designed to produce stable vibrations underneath the neck. Instead of directly stimulating the skull, shear waves were indirectly transmitted to the brain through the spine and brainstem. RESULTS: Phantom results showed that the proposed actuator did not interfere with the routine imaging sequence and successfully generated multifrequency shear waves. When compared with the conventional direct head stimulation method, brain MRE results from the proposed actuator showed no significant differences in terms of intraclass correlation coefficients (ICC) and coefficients of variation (CV). Moreover, the octahedral shear strain (OSS) generated by the indirect excitation in the frontal and parietal lobes decreased by 25.96% and 16.73% respectively. Evaluation of CBF in healthy volunteers revealed no significant changes for the indirect excitation method, whereas significant decreases in CBF were observed in four subregions when employing direct excitation. CONCLUSION: The proposed actuator offers a more accurate and comfortable approach to MRE measurements while causing minimal CBF alterations. SIGNIFICANCE: This work presents the first demonstration of an indirect excitation brain MRE system that minimizes CBF changes, thus holding potential for future applications of brain MRE.

9.
Insights Imaging ; 15(1): 91, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38530543

ABSTRACT

OBJECTIVES: The capability of MR elastography (MRE) to differentiate fibrosis and inflammation, and to provide precise diagnoses is crucial, whereas the coexistence of fibrosis and inflammation may obscure the diagnostic accuracy. METHODS: In this retrospective study, from June 2020 to December 2022, chronic viral hepatitis patients who underwent multifrequency MRE (mMRE) were included in, and further divided into, training and validation cohorts. The hepatic viscoelastic parameters [shear wave speed (c) and loss angle (φ) of the complex shear modulus] were obtained from mMRE. The logistic regression and receiver operating characteristic (ROC) curves were generated to evaluate performance of viscoelastic parameters for fibrosis and inflammation. RESULTS: A total of 233 patients were assigned to training cohort and validation cohorts (mean age, 52 years ± 13 (SD); 51 women; training cohort, n = 170 (73%), and validation cohort, n = 63 (27%)). Liver c exhibited superior performance in detecting fibrosis with ROC (95% confidence interval) of ≥ S1 (0.96 (0.92-0.99)), ≥ S2 (0.86 (0.78-0.92)), ≥ S3 (0.89 (0.84-0.95)), and S4 (0.88 (0.83-0.93)). Similarly, φ was effective in diagnosing inflammation with ROC values of ≥ G2 (0.72 (0.63-0.81)), ≥ G3 (0.88 (0.83-0.94)), and G4 (0.92 (0.87-0.98)). And great predictive discrimination for fibrosis and inflammation were shown in validation cohort (all AUCs > 0.75). CONCLUSION: The viscoelastic parameters derived from multifrequency MRE could realize simultaneous detection of hepatic fibrosis and inflammation. CRITICAL RELEVANCE STATEMENT: Fibrosis and inflammation coexist in chronic liver disease which obscures the diagnostic performance of MR elastography, whereas the viscoelastic parameters derived from multifrequency MR elastography could realize simultaneous detection of hepatic fibrosis and inflammation. KEY POINTS: • Hepatic biomechanical parameters derived from multifrequency MR elastography could effectively detect fibrosis and inflammation. • Liver stiffness is useful for detecting fibrosis independent of inflammatory activity. • Fibrosis could affect the diagnostic efficacy of liver viscosity in inflammation, especially in early-grade of inflammation.

10.
Chem Soc Rev ; 53(8): 3656-3686, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38502089

ABSTRACT

Advancements in nanochemistry have led to the development of engineered gold nanostructures (GNSs) with remarkable potential for a variety of dental healthcare applications. These innovative nanomaterials offer unique properties and functionalities that can significantly improve dental diagnostics, treatment, and overall oral healthcare applications. This review provides an overview of the latest advancements in the design, synthesis, and application of GNSs for dental healthcare applications. Engineered GNSs have emerged as versatile tools, demonstrating immense potential across different aspects of dentistry, including enhanced imaging and diagnosis, prevention, bioactive coatings, and targeted treatment of oral diseases. Key highlights encompass the precise control over GNSs' size, crystal structure, shape, and surface functionalization, enabling their integration into sensing, imaging diagnostics, drug delivery systems, and regenerative therapies. GNSs, with their exceptional biocompatibility and antimicrobial properties, have demonstrated efficacy in combating dental caries, periodontitis, peri-implantitis, and oral mucosal diseases. Additionally, they show great promise in the development of advanced sensing techniques for early diagnosis, such as nanobiosensor technology, while their role in targeted drug delivery, photothermal therapy, and immunomodulatory approaches has opened new avenues for oral cancer therapy. Challenges including long-term toxicity, biosafety, immune recognition, and personalized treatment are under rigorous investigation. As research at the intersection of nanotechnology and dentistry continues to thrive, this review highlights the transformative potential of engineered GNSs in revolutionizing dental healthcare, offering accurate, personalized, and minimally invasive solutions to address the oral health challenges of the modern era.


Subject(s)
Gold , Gold/chemistry , Humans , Surface Properties , Metal Nanoparticles/chemistry , Dentistry , Drug Delivery Systems , Nanotechnology/methods
11.
Neuroimage ; 291: 120588, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38537765

ABSTRACT

BACKGROUND: Parkinson's disease (PD) is associated with the loss of neuromelanin (NM) and increased iron in the substantia nigra (SN). Magnetization transfer contrast (MTC) is widely used for NM visualization but has limitations in brain coverage and scan time. This study aimed to develop a new approach called Proton-density Enhanced Neuromelanin Contrast in Low flip angle gradient echo (PENCIL) imaging to visualize NM in the SN. METHODS: This study included 30 PD subjects and 50 healthy controls (HCs) scanned at 3T. PENCIL and MTC images were acquired. NM volume in the SN pars compacta (SNpc), normalized image contrast (Cnorm), and contrast-to-noise ratio (CNR) were calculated. The change of NM volume in the SNpc with age was analyzed using the HC data. A group analysis compared differences between PD subjects and HCs. Receiver operating characteristic (ROC) analysis and area under the curve (AUC) calculations were used to evaluate the diagnostic performance of NM volume and CNR in the SNpc. RESULTS: PENCIL provided similar visualization and structural information of NM compared to MTC. In HCs, PENCIL showed higher NM volume in the SNpc than MTC, but this difference was not observed in PD subjects. PENCIL had higher CNR, while MTC had higher Cnorm. Both methods revealed a similar pattern of NM volume in SNpc changes with age. There were no significant differences in AUCs between NM volume in SNpc measured by PENCIL and MTC. Both methods exhibited comparable diagnostic performance in this regard. CONCLUSIONS: PENCIL imaging provided improved CNR compared to MTC and showed similar diagnostic performance for differentiating PD subjects from HCs. The major advantage is PENCIL has rapid whole-brain coverage and, when using STAGE imaging, offers a one-stop quantitative assessment of tissue properties.


Subject(s)
Parkinson Disease , Humans , Parkinson Disease/diagnostic imaging , Substantia Nigra/diagnostic imaging , Pars Compacta , Magnetic Resonance Imaging/methods , Melanins
12.
Parkinsonism Relat Disord ; 123: 106558, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38518543

ABSTRACT

INTRODUCTION: Although locus coeruleus (LC) has been demonstrated to play a critical role in the cognitive function of Parkinson's disease (PD), the underlying mechanism has not been elucidated. The objective was to investigate the relationship among LC degeneration, cognitive performance, and the glymphatic function in PD. METHODS: In this retrospective study, 71 PD subjects (21 with normal cognition; 29 with cognitive impairment (PD-MCI); 21 with dementia (PDD)) and 26 healthy controls were included. All participants underwent neuromelanin-sensitive magnetic resonance imaging (NM-MRI) and diffusion tensor image scanning on a 3.0 T scanner. The brain glymphatic function was measured using diffusion along the perivascular space (ALPS) index, while LC degeneration was estimated using the NM contrast-to-noise ratio of LC (CNRLC). RESULTS: The ALPS index was significantly lower in both the whole PD group (P = 0.04) and the PDD subgroup (P = 0.02) when compared to the controls. Similarly, the CNRLC was lower in the whole PD group (P < 0.001) compared to the controls. In the PD group, a positive correlation was found between the ALPS index and both the Montreal Cognitive Assessment (MoCA) score (r = 0.36; P = 0.002) and CNRLC (r = 0.26; P = 0.03). Mediation analysis demonstrated that the ALPS index acted as a significant mediator between CNRLC and the MoCA score in PD subjects. CONCLUSION: The ALPS index, a neuroimaging marker of glymphatic function, serves as a mediator between LC degeneration and cognitive function in PD.

13.
Cancer Imaging ; 24(1): 35, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38462607

ABSTRACT

OBJECTIVES: This review aimed to assess the predictive value of background parenchymal enhancement (BPE) on breast magnetic resonance imaging (MRI) as an imaging biomarker for pathologic complete response (pCR) after neoadjuvant chemotherapy (NACT). METHODS: Two reviewers independently performed a systemic literature search using the PubMed, MEDLINE, and Embase databases for studies published up to 11 June 2022. Data from relevant articles were extracted to assess the relationship between BPE and pCR. RESULTS: This systematic review included 13 studies with extensive heterogeneity in population characteristics, MRI follow-up points, MRI protocol, NACT protocol, pCR definition, and BPE assessment. Baseline BPE levels were not associated with pCR, except in 1 study that reported higher baseline BPE of the younger participants (< 55 years) in the pCR group than the non-pCR group. A total of 5 studies qualitatively assessed BPE levels and indicated a correlation between reduced BPE after NACT and pCR; however, among the studies that quantitatively measured BPE, the same association was observed only in the subgroup analysis of 2 articles that assessed the status of hormone receptor and human epidermal growth factor receptor 2. In addition, the predictive ability of early BPE changes for pCR was reported in several articles and remains controversial. CONCLUSIONS: Changes in BPE may be a promising imaging biomarker for predicting pCR in breast cancer. Because current studies remain insufficient, particularly those that quantitatively measure BPE, prospective and multicenter large-sample studies are needed to confirm this relationship.


Subject(s)
Breast Neoplasms , Neoadjuvant Therapy , Humans , Female , Prospective Studies , Breast/diagnostic imaging , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Magnetic Resonance Imaging/methods , Retrospective Studies , Multicenter Studies as Topic
14.
J Magn Reson Imaging ; 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38449389

ABSTRACT

BACKGROUND: Different MR elastography (MRE) systems may produce different stiffness measurements, making direct comparison difficult in multi-center investigations. PURPOSE: To assess the repeatability and reproducibility of liver stiffness measured by three typical MRE systems. STUDY TYPE: Prospective. POPULATION/PHANTOMS: Thirty volunteers without liver disease history (20 males, aged 21-28)/5 gel phantoms. FIELD STRENGTH/SEQUENCE: 3.0 T United Imaging Healthcare (UIH), 1.5 T Siemens Healthcare, 3.0 T General Electric Healthcare (GE)/Echo planar imaging-based MRE sequence. ASSESSMENT: Wave images of volunteers and phantoms were acquired by three MRE systems. Tissue stiffness was evaluated by two observers, while phantom stiffness was assessed automatically by code. The reproducibility across three MRE systems was quantified based on the mean stiffness of each volunteer and phantom. STATISTICAL TESTS: Intraclass correlation coefficients (ICC), coefficients of variation (CV), and Bland-Altman analyses were used to assess the interobserver reproducibility, the interscan repeatability, and the intersystem reproducibility. Paired t-tests were performed to assess the interobserver and interscan variation. Friedman tests with Dunn's multiple comparison correction were performed to assess the intersystem variation. P values less than 0.05 indicated significant difference. RESULTS: The reproducibility of stiffness measured by the two observers demonstrated consistency with ICC > 0.92, CV < 4.32%, Mean bias < 2.23%, and P > 0.06. The repeatability of measurements obtained using the electromagnetic system for the liver revealed ICC > 0.96, CV < 3.86%, Mean bias < 0.19%, P > 0.90. When considering the range of reproducibility across the three systems for liver evaluations, results ranged with ICCs from 0.70 to 0.87, CVs from 6.46% to 10.99%, and Mean biases between 1.89% and 6.30%. Phantom studies showed similar results. The values of measured stiffness differed across all three systems significantly. DATA CONCLUSION: Liver stiffness values measured from different MRE systems can be different, but the measurements across the three MRE systems produced consistent results with excellent reproducibility. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

15.
J Magn Reson Imaging ; 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38344910

ABSTRACT

BACKGROUND: Pretreatment identification of microvascular invasion (MVI) in hepatocellular carcinoma (HCC) is important when selecting treatment strategies. PURPOSE: To improve models for predicting MVI and recurrence-free survival (RFS) by developing nomograms containing three-dimensional (3D) MR elastography (MRE). STUDY TYPE: Prospective. POPULATION: 188 patients with HCC, divided into a training cohort (n = 150) and a validation cohort (n = 38). In the training cohort, 106/150 patients completed a 2-year follow-up. FIELD STRENGTH/SEQUENCE: 1.5T 3D multifrequency MRE with a single-shot spin-echo echo planar imaging sequence, and 3.0T multiparametric MRI (mp-MRI), consisting of diffusion-weighted echo planar imaging, T2-weighted fast spin echo, in-phase out-of-phase T1-weighted fast spoiled gradient-recalled dual-echo and dynamic contrast-enhanced gradient echo sequences. ASSESSMENT: Multivariable analysis was used to identify the independent predictors for MVI and RFS. Nomograms were constructed for visualization. Models for predicting MVI and RFS were built using mp-MRI parameters and a combination of mp-MRI and 3D MRE predictors. STATISTICAL TESTS: Student's t-test, Mann-Whitney U test, chi-squared or Fisher's exact tests, multivariable analysis, area under the receiver operating characteristic curve (AUC), DeLong test, Kaplan-Meier analysis and log rank tests. P < 0.05 was considered significant. RESULTS: Tumor c and liver c were independent predictors of MVI and RFS, respectively. Adding tumor c significantly improved the diagnostic performance of mp-MRI (AUC increased from 0.70 to 0.87) for MVI detection. Of the 106 patients in the training cohort who completed the 2-year follow up, 34 experienced recurrence. RFS was shorter for patients with MVI-positive histology than MVI-negative histology (27.1 months vs. >40 months). The MVI predicted by the 3D MRE model yielded similar results (26.9 months vs. >40 months). The MVI and RFS nomograms of the histologic-MVI and model-predicted MVI-positive showed good predictive performance. DATA CONCLUSION: Biomechanical properties of 3D MRE were biomarkers for MVI and RFS. MVI and RFS nomograms were established. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY: Stage 2.

16.
AJR Am J Roentgenol ; : 1-7, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38323783

ABSTRACT

BACKGROUND. Use of virtual monoenergetic images (VMIs) from multienergy CT scans can mitigate inconsistencies in traditional attenuation measurements that result from variation in scan-related factors. Photon-counting detector (PCD) CT systems produce VMIs as standard image output under flexible scanning conditions. OBJECTIVE. The purpose of this article was to evaluate the consistency of monoenergetic attenuation measurements obtained from a clinical PCD CT scanner across a spectrum of scanning paradigms. METHODS. A phantom with 10 tissue-simulating inserts was imaged using a clinical dual-source PCD CT scanner. Nine scanning paradigms were obtained across combinations of tube voltages (90, 120, and 140 kVp) and image quality (IQ) levels (80, 145, and 180). Images were reconstructed at VMI levels of 50, 60, 70, and 80 keV. Consistency of attenuation measurements was assessed, using the 120 kVp with IQ level of 145 scanning paradigm as the reference scan. RESULTS. For all scanning paradigms, attenuation measurements showed intra-class correlation of 0.999 and higher with respect to the reference scan. Across inserts, mean bias relative to the reference scan ranged from -14.9 to 13.6 HU, -2.7 to 1.7 HU, and -3.9 to 3.8 HU at tube voltages of 90, 120, and 140 kVp, respectively; and from -14.9 to 13.6 HU, -6.4 to 3.8 HU, -3.7 to 1.4 HU, and -7.2 to 4.3 HU at VMI levels of 50, 60, 70, and 80 keV, respectively. Thus, mean bias did not exceed 5 HU for any insert at tube potentials of 120 kVp and 140 kVp, nor for any insert at a VMI level of 70 keV. At a VMI level of 50 keV and tube potential of 90 kVp, mean bias exceeded 5 HU for 14 of 30 possible combinations of inserts and scanning paradigms and exceeded 10 HU for four of 30 such combinations. At VMI levels of both 60 and 80 keV, mean bias exceeded 5 HU for only two combinations of inserts and scanning paradigms, all at a tube potential of 90 kVp. CONCLUSION. PCD CT generally provided consistent attenuation measurements across combinations of scanning paradigms and VMI levels. CLINICAL IMPACT. PCD CT may facilitate quantitative applications of CT data in clinical practice.

17.
J Magn Reson Imaging ; 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38376448

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI)-based virtual MR elastography (DWI-vMRE) in the assessment of breast lesions is still in the research stage. PURPOSE: To investigate the usefulness of elasticity values on DWI-vMRE in the evaluation of breast lesions, and the correlation with the values calculated from shear-wave elastography (SWE). STUDY TYPE: Prospective. POPULATION/SUBJECTS: 153 patients (mean age ± standard deviation: 55 ± 12 years) with 153 pathological confirmed breast lesions (24 benign and 129 malignant lesions). FIELD STRENGTH/SEQUENCE: 1.5-T MRI, multi-b readout segmented echo planar imaging (b-values of 0, 200, 800, and 1000 sec/mm2 ). ASSESSMENT: For DWI-vMRE assessment, lesions were manually segmented using apparent diffusion coefficient (ADC0-1000 ) map, then the region of interests were copied to the map of shifted-ADC (sADC200-800 , sADC 200-1500 ). For SWE assessment, the shear modulus of the lesions was measured by US elastic modulus (µUSE ). Intraclass/interclass kappa coefficients were calculated to measure the consistency. STATISTICAL TESTS: Pearson's correlation was used to assess the relationship between sADC and µUSE . A receiver operating characteristic analysis with the area under the curve (AUC) was performed to compare the diagnostic accuracy between benign and malignant breast lesions of sADC and µUSE . A P value <0.05 was considered statistically significant. RESULTS: There were significant differences between benign and malignant breast lesions of µUSE (24.17 ± 10.64 vs. 37.20 ± 12.61), sADC200-800 (1.38 ± 0.31 vs. 0.97 ± 0.18 × 10-3 mm2 /sec), and sADC200-1500 (1.14 ± 0.30 vs. 0.78 ± 0.13 × 10-3 mm2 /sec). In all breast lesions, a moderate but significant correlation was observed between µUSE and sADC200-800 /sADC200-1500 (r = -0.49/-0.44). AUC values to differentiate benign from malignant lesions were as follows: µUSE , 0.78; sADC200-800 , 0.89; sADC200-1500 , 0.89. DATA CONCLUSIONS: Both SWE and DWI-vMRE could be used for the differentiation of benign versus malignant breast lesions. Furthermore, DWI-vMRE with the use of sADC show relatively higher AUC values than SWE. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 2.

18.
BMC Oral Health ; 24(1): 243, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38360594

ABSTRACT

OBJECTIVES: To investigate the association between serum per- and polyfluoroalkyl substances (PFAS) and periodontitis, and further explore the possible mediating role of sex hormones in this association. METHODS: We extracted data from National Health and Nutrition Examination Survey (NHANES) 2009-2014. Univariable and multivariable logistic regression models were performed to investigate the association between serum levels of seven PFASs and periodontitis. Bayesian kernel machine regression (BKMR) was conducted to assess the joint effect of PFASs in mixtures. Mediation analyses were used to explore the potential mediating role of sex hormones. RESULTS: Participants with periodontitis had higher concentrations of serum perfluorooctane sulfonate (PFOS) and perfluorononanoic acid (PFNA) than those without periodontitis (both P < 0.05). In fully adjusted models, high serum concentrations of PFOS and PFNA were positively associated with periodontitis (tertile 3 vs. tertile 1: prevalence ratio (PR) = 1.19 for PFOS, 95% CI: 1.01-1.39; PR = 1.17 for PFNA, 95% CI: 1.02-1.34). The results from the BKMR models consistently showed a positive association between PFAS mixtures and periodontitis. Of note, testosterone and the ratio of testosterone to estradiol significantly mediated the relationship between high level of PFOS and periodontitis, accounting for 16.5% and 31.7% of the total effect, respectively. Sensitivity analyses yielded similar results when using periodontal clinical indices (mean loss of attachment, mean periodontal probing depth, and the number of teeth) as dependent variables. CONCLUSIONS: These findings provide evidence to support a positive association between certain PFASs and periodontitis, which might be partially mediated by sex hormones.


Subject(s)
Alkanesulfonic Acids , Environmental Pollutants , Fatty Acids , Fluorocarbons , Periodontitis , Humans , Nutrition Surveys , Bayes Theorem , Gonadal Steroid Hormones , Testosterone
19.
ACS Appl Mater Interfaces ; 16(7): 8442-8458, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38335323

ABSTRACT

The disruption of host-microbe homeostasis and uncontrolled inflammatory response have been considered as vital causes for developing periodontitis, subsequently leading to an imbalance between the bone and immune system and the collapse of bone homeostasis. Consequently, strategies to modulate the immune response and bone metabolization have become a promising approach to prevent and treat periodontitis. In this study, we investigated the cooperative effects of Nel-like molecule type 1 (Nell-1) and gold nanoparticles (AuNPs) on macrophage polarization, osteoclast differentiation, and the corresponding functions in an experimental model of periodontitis in rats. Nell-1-combined AuNPs in in vitro studies were found to reduce the production of inflammatory factors (TNF-α, p < 0.0001; IL-6, p = 0.0012), modulate the ratio of M2/M1 macrophages by inducing macrophage polarization into the M2 phenotype, and inhibit cell fusion, maturation, and activity of osteoclasts. Furthermore, the local application of Nell-1-combined AuNPs in in vivo studies resulted in alleviation of damages to the periodontal and bone tissues, modulation of macrophage polarization and the activity of osteoclasts, and alteration of the periodontal microbiota, in which the relative abundance of the probiotic Bifidobacterium increased (p < 0.05). These findings reveal that Nell-1-combined AuNPs could be a promising drug candidate for the prevention and treatment of periodontitis. However, Nell-1-combined AuNPs did not show organ toxicity or impair the integrity of intestinal epithelium but alter the gut microbiota, leading to the dysbiosis of gut microbiota. The adverse impact of changes in gut microbiota needs to be further investigated. Nonetheless, this study provides a novel perspective and direction for the biological safety assessment of biomaterials in oral clinical applications.


Subject(s)
Gastrointestinal Microbiome , Metal Nanoparticles , Periodontitis , Rats , Animals , Gold/pharmacology , Osteogenesis/genetics , Metal Nanoparticles/therapeutic use , Periodontitis/drug therapy , Macrophages
20.
Int Dent J ; 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38388241

ABSTRACT

AIMS: Arsenic exposure is a significant global public health concern and has been implicated in endocrine disruption and increased oxidative stress, both of which are crucial pathogenic mechanisms of periodontitis. This study aimed to investigate the association of urinary total arsenic and arsenic species with periodontitis and to further explore the potential mediating roles of sex hormones and oxidative stress indicators. METHODS: Data used in this study were derived from the 2013-2014 National Health and Nutrition Examination Survey (NHANES) in the US population. In all, 1063 participants with complete data were included in this study. Weighted logistic regression analyses were used to evaluate the relationship between urinary arsenic and periodontitis. Mediation analyses were used to explore the effects of potential mediators on these associations. RESULTS: High concentrations of urinary dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), 2 types of toxic urinary arsenic (TUA2), and 4 types of toxic urinary arsenic (TUA4) were positively related to periodontitis (P < .05). After adjusting for potential confounders, the positive association remained significant (odds ratio, 1.32; 95% confidence interval, 1.01-1.71). Testosterone may partially mediate the relationship between MMA and periodontitis, with mediating effects of 21.78% and 39.73% of the total effect. No significant mediation effect of oxidative stress indicators was found for this relationship. CONCLUSIONS: This study reports a positive association between urinary MMA and periodontitis, and testosterone may mediate this relationship. Our findings serve as a call for action to avoid the deployment of arsenic-containing therapeutic agents as treatment modalities for oral afflictions.

SELECTION OF CITATIONS
SEARCH DETAIL
...