Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Qual Life Res ; 33(3): 745-752, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38064016

ABSTRACT

OBJECTIVE: This study aimed to translate and culturally adapt the standardized outcomes in nephrology-hemodialysis fatigue (SONG-HD fatigue) scale and to assess the psychometric properties of the Chinese version of the SONG-HD fatigue (C-SONG-HD fatigue) scale. METHODS: Forward and back translations were used to translate the SONG-HD fatigue scale into Chinese. We used the C-SONG-HD fatigue scale to survey Chinese patients undergoing hemodialysis (HD) in China. We examined the distribution of responses and floor and ceiling effects. Cronbach's alpha and McDonald's omega coefficient, intraclass coefficients, and Spearman correlations were used to assess internal consistency reliability, test-retest reliability, and convergent validity, respectively. Responsiveness was also evaluated. RESULTS: In total, 489 participants across southeast China, northwest China, and central China completed the study. The C-SONG-HD fatigue scale had good internal consistency (Cronbach's alpha coefficient 0.861, omega coefficient 0.916), test-retest reliability (intraclass correlation coefficient 0.695), and convergent validity (Spearman correlation 0.691). The analysis of all first-time HD patients did not show notable responsiveness, and only patients with temporary vascular access had good responsiveness with an effect size (ES) of 0.54, a standardized response mean (SRM) of 0.85, and a standard error of measurement (SEM) of 0.77. CONCLUSION: The Chinese version of the SONG-HD fatigue scale showed satisfactory reliability and validity in patients undergoing hemodialysis (HD) in China. It could be used as a tool to measure the fatigue of Chinese HD patients.


Subject(s)
Nephrology , Humans , Reproducibility of Results , Quality of Life/psychology , Surveys and Questionnaires , Renal Dialysis , Fatigue/therapy , China , Psychometrics , Translations
2.
Biomed Environ Sci ; 22(1): 62-9, 2009 Feb.
Article in English | MEDLINE | ID: mdl-19462690

ABSTRACT

OBJECTIVE: To establish a reliable platform for screening glucokinase activators (GKAs) in vitro. METHODS: Pancreatic glucokinase (PGK) protein expressed in a prokaryotic expression system as a histidine-tagged fusion protein from Homo sapiens was produced. Then, response surface methodology (RSM) was used to optimize the microplate-based GKA screening platform. In the first step of optimization with Plackett-Burman design (PBD), initial pH, reaction time and MgCl2 were found to be important factors affecting the activity ratio of GKA (RO-28-1675) significantly. In the second step, a 2(3) full factorial central composite design (CCD) and RSM were applied to the optimal condition determination of each significant variable. A second-order polynomial was determined by a multiple regression analysis of the experimental data. RESULTS: The following optimal values for the critical factors were obtained: initial pH 0 (7.0), reaction time-0.63 (13.7 min) and MgCl2 0.11 (2.11 mmol/L) with a predicted value of the maximum activity ratio of 34.1%. CONCLUSION: Under the optimal conditions, the practical activity ratio is 34.8%. The determination coefficient (R2) is 0.9442, ensuring adequate credibility of the model. LLAE3, extracted from Folium nelumbinis in our laboratory, has prominently activated effects on PGK.


Subject(s)
Drug Discovery/methods , Enzyme Activators/analysis , Glucokinase/metabolism , Hypoglycemic Agents/analysis , Analysis of Variance , Escherichia coli/genetics , Genetic Vectors , Humans , Hydrogen-Ion Concentration , Kinetics , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL