Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Curr Med Imaging ; 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-38310552

ABSTRACT

BACKGROUND: To compare the integrity, clarity, conciseness, etc., of the structured report (SR) versus free-text report (FTR) for computed tomography enterography of Crohn's disease (CD). METHODS: FTRs and SRs were generated for 30 patients with CD. The integrity, clarity, conciseness etc., of SRs versus FTRs, were compared. In this study, an evidence-based medicine practice model was utilized on 92 CD patients based on SR in order to evaluate its clinical value. Then, the life quality of the patients in two groups was evaluated before and after three months of intervention using an Inflammatory Bowel Disease Questionnaire (IBDQ). RESULTS: SRs received higher ratings for satisfaction with integrity (median rating 4.27 vs. 3.75, P=0.008), clarity (median rating 4.20 vs. 3.43, P=0.003), conciseness (median rating 4.23 vs. 3.20, P=0.003), the possibility of contacting a radiologist to interpret (median rating 4.17 vs. 3.20, P<0.001), and overall clinical impact (median rating 4.23 vs. 3.27, P<0.001) than FTRs. Besides, research group had higher score of IBDQ intestinal symptom dimension (median score 61.13 vs. 58.02, P=0.003), IBDQ systemic symptom dimension (median score 24.48 vs. 20.67, P<0.001), IBDQ emotional capacity dimension (median score 65.65 vs. 61.74, P<0.001), IBDQ social ability dimension (median score 26.80 vs. 22.37, P<0.001), and total IBDQ score (median score 178.07 vs. 162.80, P<0.001) than control group. CONCLUSION: The SR of CTE in CD patients was conducive to improving the quality and readability of the report, and CD patients' life quality could significantly improve after the intervention of an evidence-based medicine model based on SR.

2.
J Coll Physicians Surg Pak ; 33(2): 205-211, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36797632

ABSTRACT

The aim of this review was to compare the performance of contrast-enhanced versus non-contrast-enhanced helical computed tomography (CT) for acute appendicitis as reported. A systematic search of PubMed and Embase was conducted. The sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the summary receiver operating characteristic curves (AUC) were evaluated using Meta-DiSc. Quality was assessed using QUADAS 2. Eight articles with 1602 patients were included. For contrast-enhanced CT, the pooled sensitivity was 0.95 (95% CI: 0.93-0.96) with a specificity of 0.94 (95%CI: 0.93-0.96). The PLR, NLR, and DOR were 14.74 (95%CI: 9.06-23.97), 0.06 (95%CI: 0.03-0.11), and 305.31 (95%CI: 107.14-870.08), respectively. For non-contrast-enhanced CT, the pooled sensitivity was 0.85 (95% CI: 0.82-0.87) with a specificity of 0.93 (95%CI: 0.92-0.95). The PLR, NLR, and DOR were 12.22 (95% CI: 9.52-15.69), 0.15 (95%CI: 0.09-0.25), 80.98 (95%CI: 41.65-157.45), respectively. The AUC was not statistically different (Z=0.737, p=0.461). This data suggest that the contrast-enhanced CT has better diagnostic performance for acute appendicitis than non-contrast CT. Key Words: Acute appendicitis, Contrast-enhanced computed tomography' scan, Non-contrast-enhanced computed tomography' scan, Meta-analysis.


Subject(s)
Appendicitis , Humans , Appendicitis/diagnostic imaging , Tomography, X-Ray Computed/methods , ROC Curve , Acute Disease , Tomography, Spiral Computed , Sensitivity and Specificity
3.
World J Surg Oncol ; 20(1): 292, 2022 Sep 12.
Article in English | MEDLINE | ID: mdl-36089588

ABSTRACT

OBJECTIVES: An investigation of the effects of different types of the inferior mesenteric artery (IMA) on laparoscopic left colic artery (LCA) radical resection of rectal cancer was conducted. METHODS: Clinical data were collected from 92 patients who underwent laparoscopic radical resection of rectal cancer with preservation of the LCA at Nantong University's Second Affiliated Hospital. All patients underwent full-abdominal dual-energy CT enhancement examination before surgery and 3D post-processing reconstruction of the IMA. Two radiologists with >3 years of experience in abdominal radiology jointly conducted the examination. A total of three types of IMA were identified among the patients: IMA type I (the LCA arising independently from the IMA), type II (LCA and sigmoid colon artery [SA] branching from a common trunk from IMA), and type III (LCA, SA, and superior rectal artery [SRA] branching from the IMA at the same point). The baseline data, pathological results, and intra-operative and post-operative indicators of the groups were analyzed. RESULTS: The proportions of type I, type II, and type III IMA were 58.70% (54/92), 18.48% (17/92), and 22.82% (21/92), respectively. IMA typing was consistent with the preoperative CT evaluation results. The intra-operative blood loss of type III IMA patients [median (interquartile spacing), M (P25, P75): 52.00 (39.50, 68.50) ml] was higher than that of type I and II IMA patients [35.00 (24.00, 42.00) and 32.00 (25.50, 39.50) ml, respectively] (P<0.05). The incidence of anastomotic fistula in type III IMA patients (4 cases, 19.05%) was higher than that in non-type III IMA patients (1 case, 1.41%) (X2=6.679, P=0.010). The incidence of postoperative complications among the three types of IMA was not significantly different (P>0.05). CONCLUSIONS: Among rectal cancer patients undergoing laparoscopic LCA preservation, type III IMA patients had more intraoperative bleeding and a higher incidence of postoperative anastomotic fistula. However, this did not increase the risk of overall postoperative complications.


Subject(s)
Laparoscopy , Rectal Neoplasms , Arteries/pathology , Humans , Laparoscopy/adverse effects , Laparoscopy/methods , Mesenteric Artery, Inferior/surgery , Postoperative Complications/etiology , Postoperative Complications/surgery , Rectal Neoplasms/pathology , Rectal Neoplasms/surgery
4.
World J Clin Cases ; 10(13): 4020-4032, 2022 May 06.
Article in English | MEDLINE | ID: mdl-35665105

ABSTRACT

BACKGROUND: Superior mesenteric artery embolism (SMAE) has acute onset and fast progression, which seriously threatens the life of patients. Multidetector computed tomography (MDCT) is one of the most important diagnostic methods for SMAE, which plays an important role in the diagnosis and prognosis of SMAE. AIM: To evaluate the value of combined clinical data and MDCT findings in the diagnosis of acute SMAE and predict the risk factors for SMAE-related death. METHODS: Data from 53 SMAE patients who received abdominal MDCT multi-phase enhancement and superior mesenteric artery digital subtraction angiography examinations were collected. Univariate cox regression and multivariate cox model were used to analyze the correlation between death risk and clinical and computed tomography features in SMAE patients. RESULTS: Univariate Cox regression model showed that intestinal wall thinning, intestinal wall pneumatosis, blood lactate > 2.1 mmol/L and blood pH < 7.35 increased the risk of death in patients with SMAE. After adjusting for age, sex, embolic involvement length and embolic distribution region, multivariate Cox regression model I showed that blood lactate > 2.1 mmol/L (HR = 5.26, 95%CI: 1.04-26.69, P = 0.045) and intestinal wall thinning (HR = 9.40, 95%CI: 1.05-83.46, P = 0.044) were significantly increases the risk of death in patients with SMAE. CONCLUSION: For patients with SAME, increased blood lactate and intestinal wall thinning are the risk factors for death; hence, close monitoring may reduce the mortality rate. Clinical observation combined with MDCT signs can significantly improve SMAE diagnosis.

5.
BMC Med Imaging ; 22(1): 38, 2022 03 08.
Article in English | MEDLINE | ID: mdl-35260088

ABSTRACT

BACKGROUND: This study was aimed to explore the clinical application of dual-energy computed tomography (DECT) monoenergetic plus (mono+) imaging to evaluate anatomical variations in the inferior mesenteric artery (IMA). METHODS: The clinical and imaging data of 212 patients who had undergone total abdominal DECT were retrospectively analyzed. The post-processing mono+ technique was used to obtain 40-keV single-level images in the arterial phase. Three-dimensional reconstruction was performed to evaluate the relationship between the IMA root position and the spinal level, IMA length, and IMA branch type, as well as the position of the left colic artery (LCA) and inferior mesenteric vein (IMV) at the IMA root level. RESULTS: The IMA root was located at the L3 level in 78.3% of cases and at the L2/L3 level in 3.3%. The highest vertebral level of IMA origin was L2 (4.2%), and the lowest was L4 (7.1%). The distance from the IMA root to the level of the sacral promontory was 99.58 ± 13.07 mm, which increased with the elevation of the IMA root at the spinal level. Of the patients, 53.8% demonstrated Type I IMA, 23.1% Type II, 20.7% Type III, and 2.4% Type IV. The length of the IMA varied from 13.6 to 66.0 mm. 77.3% of the IMAs belonged to Type A, the adjacent type, and 22.7% to Type B, the distant type. CONCLUSION: DECT mono+ can preoperatively evaluate the anatomical characteristics of the IMA and the positional relationship between the LCA and IMV at the IMA root level, which would help clinicians plan individualized surgery for patients.


Subject(s)
Mesenteric Artery, Inferior , Mesenteric Veins , Abdomen , Arteries , Humans , Mesenteric Artery, Inferior/diagnostic imaging , Mesenteric Artery, Inferior/surgery , Mesenteric Veins/diagnostic imaging , Retrospective Studies
6.
BMC Med Imaging ; 21(1): 185, 2021 12 03.
Article in English | MEDLINE | ID: mdl-34861843

ABSTRACT

BACKGROUND: This retrospective study aimed to investigate the usefulness of the optimized kiloelectron volt (keV) for virtual monoenergetic imaging (VMI) combined with iodine map in dual-energy computed tomography enterography (DECTE) in the diagnosis of Crohn's disease (CD). METHODS: Seventy-two patients (mean age: 41.89 ± 17.28 years) with negative computed tomography enterography (CTE) were enrolled for investigating the optimized VMI keV in DECTE by comparing subjective and objective parameters of VMIs that were reconstructed from 40 to 90 keV. Moreover, 68 patients (38.27 ± 15.10 years; 35 normal and 33 CD) were included for evaluating the diagnostic efficacy of DECTE iodine map at the optimized VMI energy level and routine CTE for CD and active CD. Statistical analysis for all data was conducted. RESULTS: Objective and subjective imaging evaluations showed the best results at 60 keV for VMIs. The CT values of the normal group, active subgroup, and CD group during the small intestinal phase at routine 120 kVp or 60 keV VMI had significant differences. The diagnostic efficacy of an iodine map was the best when NIC = 4% or fat value = 45.8% for CD, whereas NIC < 0.35 or the fat value < 0.38 for active CD. The combined routine CTE and optimized VMI improved the diagnostic efficacy (P < 0.001). CONCLUSIONS: VMI at 60 keV provided the best imaging quality on DECTE. NIC and fat value provided important basis for active CD evaluation. Routine CTE combined with VMI at 60 keV improved the diagnostic efficiency for CD.


Subject(s)
Crohn Disease/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies
7.
Biomed Pharmacother ; 138: 111477, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33765582

ABSTRACT

Protein O-GlcNAcylation is a dynamic post-translational protein modification that regulates fundamental cellular functions in both normal physiology and diseases. The levels of protein O-GlcNAcylation are determined by flux of the hexosamine biosynthetic pathway (HBP), which is a branch of glycolysis, and are directly controlled by a pair of enzymes: O-GlcNAc transferase (OGT) and O-GlcNAcase (OGA). An increase in protein O-GlcNAcylation has been shown to have protective effects on ischemia-related insults in the heart and brain. To determine whether O-GlcNAcylation plays a beneficial role in ischemia-reperfusion (IR)-induced intestinal injury, we used pharmacological manipulation of O-GlcNAc to induce loss- and gain-of-function conditions and evaluated the viability and apoptosis of intestinal epithelioid cells in an in vitro oxygen-glucose deprivation (OGD) model and tissue injury grade in a small intestinal ischemia-reperfusion (SIIR) mouse model. We found that 1) Upregulation of O-GlcNAcylation induced by glucosamine (GlcN, increase in HBP flux) or thiamet G (an OGA inhibitor) enhanced intestinal cell survival in the OGD model. In contrast, downregulation of O-GlcNAcylation induced by DON (due to a reduction in HBP flux) or OMSI-1 (an OGT inhibitor) made the cells more susceptible to hypoxia injury. 2) Reducing the increase in O-GlcNAcylation levels with a combination of either GlcN with DON or thiamet G with OMSI-1 partly canceled its protective effect on OGD-induced cell injury. 3) In the in vivo SIIR mouse model, GlcN augmented intestinal protein O-GlcNAcylation and significantly alleviated intestinal injury by inhibiting cell apoptosis. These results indicate that acute increases in protein O-GlcNAcylation confer protection against intestinal ischemia insults, suggesting that O-GlcNAcylation, as an endogenous stress sensor, could be a universal protective mechanism and could be a potential therapeutic target for intestinal ischemic disease.


Subject(s)
Glucose/deficiency , Hypoxia/metabolism , Intestine, Small/metabolism , N-Acetylglucosaminyltransferases/metabolism , Oxygen/metabolism , Reperfusion Injury/metabolism , Animals , Cell Line , Hypoxia/pathology , Hypoxia/prevention & control , Intestine, Small/pathology , Male , Mice , Mice, Inbred ICR , Reperfusion Injury/pathology , Reperfusion Injury/prevention & control
8.
Urol J ; 18(1): 51-57, 2020 Jul 21.
Article in English | MEDLINE | ID: mdl-32715453

ABSTRACT

PURPOSE: In order to comprehensively determine the diagnostic accuracy of the Prostate Imaging Reporting and Data System version 1 (PI-RADS V1) and PI-RADS version 2 (PI-RADS V2) in prostate cancer (PCa) diagnosis. MATERIALS AND METHODS: The literatures were screened from the databases, including the Pubmed, Embase, Web of science and Cochrane Library up to January 20th, 2020. The meta-analysis was conducted by Meta-DiSc and quality assessment was performed by using the QUADAS. Furthermore, the sensitivity, specificity, likelihood ratio (LR), diagnostic odds ratio (DOR), as well as receiver operating curve (ROC) related to diagnostic accuracy were pooled. RESULTS: A total of 6 articles containing 814 participants (379 patients) were included in the study. For PI-RADS V1, the combined sensitivity, specificity, PLR, NLR and DOR were 0.82 (95% CI: 0.77-0.85), 0.81 (95% CI: 0.77- 0.85), 4.58 (95% CI: 2.55-8.22), 0.24 (95% CI: 0.18-0.34) and 24.00 (95% CI: 10.38-55.51). With regard to PIRADS V2, the combined sensitivity, specificity, PLR, NLR and DOR were 0.88 (95% CI: 0.84-0.91), 0.81 (95% CI: 0.77-0.84), 4.34 (95% CI: 1.98-9.49), 0.16 (95% CI: 0.08-0.32) and 33.39 (95% CI: 15.05-74.05), respectively. Furthermore, except that the sensitivity of PI-RADS V2 was significantly greater than that of PI-RADS V1 (P = 0.027), there was no remarkably difference in other indicators for the diagnosis of PCa between the two versions. CONCLUSION: Both PI-RADS V1 and PI-RADS V2 showed good diagnostic performance for PCa diagnosis; moreover, there was no difference in the diagnostic effect between them.


Subject(s)
Multiparametric Magnetic Resonance Imaging , Prostatic Neoplasms/diagnostic imaging , Data Systems , Humans , Male
9.
Jpn J Radiol ; 38(5): 458-462, 2020 May.
Article in English | MEDLINE | ID: mdl-32189176

ABSTRACT

PURPOSE: To assess the diagnostic value of multidetector computed tomography (MDCT) in small bowel obstruction (SBO) patients. METHODS: Relevant literature was searched from the Cochrane Library, Pubmed and Embase. The extracted effective data was calculated using the Meta-Disc 1.4 software; statistical heterogeneity was evaluated using Cochran's Q test and I2. RESULTS: A total of five articles were selected for the meta-analysis. In addition, the pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), as well as the diagnostic odds ratio (DOR) were 0.878 (95% CI 0.822-0.921), 0.807 (95% CI 0.753-0.854), 8.137 (95% CI 2.268-29.192), 0.127 (95% CI 0.040-0.4078) and 72.384 (95% CI 10.841-483.31), respectively. Furthermore, the AUC was 0.9648 with the Q of 0.9116. CONCLUSIONS: The data suggest that MDCT is an effective method for diagnosis of SBO.


Subject(s)
Intestinal Obstruction/diagnostic imaging , Intestine, Small/diagnostic imaging , Multidetector Computed Tomography/methods , Humans , Sensitivity and Specificity
10.
J Comput Biol ; 27(8): 1303-1312, 2020 08.
Article in English | MEDLINE | ID: mdl-31855448

ABSTRACT

This study was designed to identify several key genes and their functions in preventing or ameliorating intestinal ischemia-reperfusion (IR) injury, which could provide rationale for further exploring the regulatory mechanisms or clinical treatment for intestinal IR injury. The microarray GSE37013 of human intestinal IR injury was downloaded from Gene Expression Omnibus database. The differentially expressed genes (DEGs) with changes of reperfusion time were screened using Short Time-series Expression Miner, followed by function enrichment analysis, protein-protein interaction (PPI) network, and module construction. Subsequently, the key DEGs were identified with VEEN analysis based on the significant results of function enrichment analysis and PPI module. Finally, the gene-drug interactions were predicted using DGIdb 2.0. The DEGs of intestinal IR injury were significantly divided into three clusters with changes of reperfusion time. The genes in the three clusters were mainly enriched in transmembrane transport, defense responses, and cellular component assembly related pathways, respectively. There were 121 nodes and 281 interactions in PPI network, including one significant submodule. Protein tyrosine phosphatase, receptor type C (PTPRC) was a hub code both in PPI network and in submodule. A total of eight key DEGs were identified but only PTPRC was predicted to be interacted with eight drugs, such as infliximab. Totally, eight key genes associated with intestinal IR were identified; PTPRC especially was the most prominent potential drug target. These findings provided several potential therapeutic targets or potential breakthrough area in the study of intestinal IR injury.


Subject(s)
Computational Biology , Intestines/injuries , Leukocyte Common Antigens/genetics , Reperfusion Injury/genetics , Carrier Proteins/genetics , Gene Expression Profiling/methods , Gene Regulatory Networks/genetics , Humans , Intestines/pathology , MicroRNAs/genetics , Microarray Analysis , Protein Interaction Maps/genetics , Protein Tyrosine Phosphatases/genetics , Reperfusion Injury/pathology
11.
J Appl Clin Med Phys ; 20(1): 293-307, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30508275

ABSTRACT

OBJECTIVE: Multislice computed tomography (MSCT) has been used for diagnosis of small intestinal diseases. However, the radiation dose is a big problem. This study was to investigate whether CARE Dose 4D combined with sinogram-affirmed iterative reconstruction (SAFIRE) can provide better image quality at a lower dose for imaging small intestinal diseases compared to MSCT. METHODS: The noise reduction ability of SAFIRE was assessed by scanning the plain water mold using SOMATOM Definition Flash double-source spiral CT. CT images at each stage of radiography for 239 patients were obtained. The patients were divided into groups A and B were based on different tube voltage and current or the image recombination methods. The images were restructured using with filtered back projection (FBP) and SAFIRE (S1-S5). The contrast noise ratio (CNR), CT Dose index (CTDI), subjective scoring, and objective scoring were compared to obtain the best image and reformation parameters at different stages of CT. RESULTS: Twenty-six restructuring patterns of tube voltage and current were obtained by FBP and SAFIRE. The average radiation dose using CARE Dose 4D combined with SAFIRE (S4-S5) reduced approximately 74.85% compared to conditions where the tube voltage of 100 kV and tube current of 131 mAs for patients with MSCT small intestinal CT enterography at plain CT scan, arterial stage, small intestine, and portal venous phase. The objective and subjective scoring were all significantly different among groups A and B at each stage. CONCLUSIONS: Combination of CARE Dose 4D and SAFIRE is shown to decrease the radiation dose while maintaining image quality.


Subject(s)
Algorithms , Four-Dimensional Computed Tomography/methods , Image Processing, Computer-Assisted/methods , Intestinal Diseases/diagnostic imaging , Intestine, Small/diagnostic imaging , Multidetector Computed Tomography/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Female , Humans , Intestinal Diseases/pathology , Intestinal Diseases/radiotherapy , Intestine, Small/pathology , Intestine, Small/radiation effects , Male , Middle Aged , Radiotherapy Dosage
12.
Acad Radiol ; 25(2): 196-201, 2018 02.
Article in English | MEDLINE | ID: mdl-29122470

ABSTRACT

RATIONALE AND OBJECTIVES: Obscure gastrointestinal bleeding (OGIB) is the bleeding from the gastrointestinal tract without definite source that persists and recurs after a negative endoscopic evaluation. The study aimed to systematically evaluate the diagnostic accuracy of computed tomography enterography on OGIB detection by meta-analysis. MATERIALS AND METHODS: Studies were searched in relevant databases. With predefined inclusion criteria, eligible studies were included, followed by quality assessment using the Quality Assessment of Diagnostic Accuracy Studies scoring system. The Meta-DiSc software was used to implement the meta-analysis, and sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio with their 95% confidence intervals (CIs) were used as the effect size. Publication bias was determined by Egger test. RESULTS: A set of nine studies was included in this meta-analysis, having a relatively high quality. Under the random effects model, the pooled sensitivity and specificity were 0.724 (95% CI: 0.651-0.789) and 0.752 (95% CI: 0.691-0.807), respectively. Under the fixed effects model, the pooled positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 2.949 (95% CI: 2.259-3.850), 0.393 (95% CI: 0.310-0.497), and 9.452 (95% CI: 5.693-15.692), respectively. The area under curve of the summary receiver operating characteristic curve was 0.7916 (95% CI: 0.723-0.860). No obvious publication bias was detected (t = 1.62, P = .181). CONCLUSIONS: Computed tomography enterography might be used as a complementary to video capsule endoscopy instead of an alternative for the detection of OGIB.


Subject(s)
Gastrointestinal Hemorrhage/diagnostic imaging , Tomography, X-Ray Computed/methods , Humans , Likelihood Functions , Odds Ratio , ROC Curve
13.
Eur J Radiol ; 93: 40-45, 2017 Aug.
Article in English | MEDLINE | ID: mdl-28668429

ABSTRACT

PURPOSE: To estimate the diagnostic value of multi-slice spiral CT angiography (CTA) in lower gastrointestinal bleeding by a meta-analysis. METHODS: The relevant clinical studies on the diagnostic value of CTA were searched on PubMed, Embase and other electronic documents databases with the deadline of 2016 September. Language was limited to English. A diagnostic meta-analysis was performed by using Meta-DiSc software. The effect sizes included sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) and 95% confidence interval (CI). The Cochran-Q test and I2 statistic based on χ2 test were used for estimation of the heterogeneity. Meta-regression was performed to explore the source of heterogeneity. SROC curve was established. RESULTS: A total of 14 articles including 549 patients with lower gastrointestinal bleeding were enrolled in the meta-analysis. The combined PLR, NLR and DOR were respectively 8.149, 0.158 and 56.213. There were significant heterogeneities in all estimations but we could not find the sources by meta-regression based on study design, study location, CT slices and sample size. The AUC and Q index under the fixed effect model was respectively 0.9463 and 0.8856. CONCLUSIONS: The multi-slice CTA has high diagnostic value for lower gastrointestinal bleeding.


Subject(s)
Computed Tomography Angiography/methods , Gastrointestinal Hemorrhage/diagnostic imaging , Lower Gastrointestinal Tract/diagnostic imaging , Humans , Sensitivity and Specificity
14.
Clin Imaging ; 40(5): 892-6, 2016.
Article in English | MEDLINE | ID: mdl-27183136

ABSTRACT

OBJECTIVE: To prospectively evaluate the inter- and intraobserver agreement of apparent diffusion coefficient (ADC) measurements in free breathing, breath-hold, and respiratory triggered diffusion-weighted imaging (DWI) of lung cancer. METHODS: Twenty-two patients with lung cancer (tumor size >2cm) underwent DWIs (3.0T) in three imaging methods. Lesion ADCs were measured twice by both of the two independent observers and compared. RESULTS: No statistical significance was found among methods, though respiratory-triggered DWI tended to have higher ADCs than breath-hold DWI. Great inter- and intraobserver agreement was shown. CONCLUSION: ADCs had good inter- and intraobserver agreement in all three DWI methods.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Lung Neoplasms/diagnosis , Aged , Breath Holding , Female , Humans , Male , Middle Aged , Observer Variation , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...