Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Adv Healthc Mater ; : e2402321, 2024 Aug 09.
Article in English | MEDLINE | ID: mdl-39126126

ABSTRACT

Angiogenesis is a key player in drug resistance to targeted therapies for breast cancer. The average expression of angiogenesis-related cytokines is widely associated with the treatments of target therapies for a population of cells or spheroids, overlooking the distinct responses for individuals. In this work, a highly integrated microfluidic platform is developed for the generation of monodisperse multicellular tumor spheroids (MTSs), drug treatments, and the measurement of cytokines for individual MTSs in a single chip. The platform allows the correlation evaluation between cytokine secretion and drug treatment at the level of individual spheroids. For validation, quantities of six representative proangiogenic cytokines are tested against treatments with four model drugs at varying times and concentrations. By applying a linear regression model, significant correlations are established between cytokine secretion and the treated drug concentration for individual spheroids. The proposed platform provides a high-throughput method for the investigation of the molecular mechanism of the cytokine response to targeted therapies and paves the way for future drug screening using predictive regression models at the single-spheroid level.

2.
Talanta ; 277: 126413, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38876035

ABSTRACT

Infectious diseases have always been a seriously endanger for human life and health. A rapid, accurate and ultra-sensitive virus nucleic acid detection is still a challenge to deal with infectious diseases. Here, a RNA extraction-free reduced graphene oxide-based reverse transcription-loop-mediated isothermal amplification (EF-G-RT-LAMP) fluorescence assay was developed to achieve high-throughput, rapid and ultra-sensitive SARS-CoV-2 RNA detection. The whole detection process only took ∼36 min. The EF-G-RT-LAMP assay achieves a detection limit of 0.6 copies µL-1 with a wide dynamic range of aM-pM. A large number (up to 384) of samples can be detected simultaneously. Simulated detection of the COVID-19 pseudovirus and clinical samples in nasopharyngeal swabs demonstrated a high-throughput, rapid and ultra-sensitive practical detection capability of the EF-G-RT-LAMP assay. The results proved that the assay would be used as a rapid, easy-to-implement approach for epidemiologic diagnosis and could be extended to other nucleic acid detections.


Subject(s)
COVID-19 , Graphite , Limit of Detection , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Graphite/chemistry , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nucleic Acid Amplification Techniques/methods , Humans , COVID-19/diagnosis , COVID-19/virology , RNA, Viral/analysis , RNA, Viral/genetics , Molecular Diagnostic Techniques/methods , Fluorescence
SELECTION OF CITATIONS
SEARCH DETAIL