Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1026288

ABSTRACT

Objective To observe the value of ultrasound-guided intra-articular injection of hypertonic glucose(HG)for treating knee osteoarthritis in plateau area.Methods Ninety-one patients with knee osteoarthritis in plateau area(124 affected knee joints)were enrolled.The knee joints were divided into 20%HG group(n=67),25%HG group(n=42)or sodium hyaluronate group(n=15)based on the medication.Clinical and ultrasound scores were compared before and after treatment,and the efficacy of injection of HG was evaluated.Results At the 12th and 48th weeks after treatment,visual analog scale(VAS)scores decreased in all 3 groups(all P<0.05),and Lysholm scores of 20%HG group and 25%HG group increased compared to those before treatment(all P<0.05).The difference of Lysholm score before and in the 12th week after treatment,and of VAS score before and in the 48th week after treatment of 25%HG group were higher than those of 20%HG group(both P<0.05).The joint exudation score of 20%HG group decreased in the 48th week after treatment compared to that before treatment(P<0.05),and the synovial blood flow score decreased in the 12th and 48th weeks after treatment compared to those before treatment(both P<0.05).The joint exudation score of 25%HG group decreased in the 48th week after treatment compared to that before treatment(P<0.05),and the synovial hyperplasia and synovial blood flow score decreased in the 12th and 48th weeks after treatment compared to before treatment(all P<0.05).The joint exudation score of sodium hyaluronate group decreased in the 48th week after treatment compared to that before treatment(P<0.05),and the synovial hyperplasia score decreased in the 12th and 48th weeks after treatment compared to that before treatment(both P<0.05).Conclusion Ultrasound-guided intra-articular injection of HG,esp.25%HG,had certain value for treating knee osteoarthritis in plateau area.

2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-664760

ABSTRACT

Objective To investigate the value of ultrasonic direct signs and indirect signs in diagnosis of rotator cuff tears (RCTs).Methods Fifty-two patients underwent ultrasonography before arthroscopy were enrolled.The efficacy of ultrasonic direct and indirect signs in diagnosis of RCTs was calculated,and the accuracy of ultrasonic direct signs in diagnosis of subtypes for RCTs was compared with arthroscopic results.Results The accuracy of ultrasonic direct signs in diagnosis of the presence of tears,full-thickness tears and partial-thickness tears was 90.38% (47/52),96.15% (50/52)and 86.54% (45/52),respectively.Additionally,the consistency of ultrasonic direct signs in diagnosis of subtypes for RCTs with arthroscopic results was good.With regard to ultrasonic indirect signs,the specificity of effusions including all subacromial/subdeltoid bursa effusions,intra-articular fluid and biceps tendon sheath effusions,subdeltoid bursa hernia and cartilage demarcation sign was 80.95%(17/21),90.48% (19/21) and 95.24% (20/21),respectively.Conclusion Ultrasonic direct signs combined with indirect signs have high clinical value in diagnosis of subtypes for RCTs.

SELECTION OF CITATIONS
SEARCH DETAIL